CD35 / CD35P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Similar documents
CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

K100P DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E DEHUMIDIFIER (FULL PRODUCT RANGE) OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

EBAC MODEL PD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

RM95 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Superdryer Dehumidifiers

GL-DEH Series Portable Dehumidifier Operating Instructions

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

Portable Dehumidifier

Portable Dehumidifier with Internal Pump

Operation manual. Dehumidifier CFO-20N

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Air Cleaning Equipment, Inc. 303 N. Main St. Broadway, NC iers.com

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

OWN ER'SGUIDE READ AND SAVE THESE INSTRUCTIONS

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

5) Do not start or stop the unit by inserting or pulling out the power plug.

WatchDog NXT60. Installation and Operations Manual. Seaira Global, LLC NC Highway 50 Surf City, NC (910)

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

EBAC MODEL GENESIS AVENGER APOLLO AIR MOVER OWNER S MANUAL

Owner s Manual Refrigerated Compressed Air Dryer Model F-50

Operating Instructions

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER DEUMIDIFICATORE DESHUMIDIFICADOR DESUMIDIFICADOR

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160

Instruction Manual Item No.: V~, 60Hz

OWNER S GUIDE READ AND SAVE THESE INSTRUCTIONS

Quest Dry 105, 155, and 205 Dual

XD-125 OWNER S MANUAL COMMERCIAL DEHUMIDIFIER

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

3000 Series. UK Manual Accessories Warranty Registration

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Refrigerator Freezer Installation and Operation Manual

LUMBER DRYER LD3000 OWNER S MANUAL

Rev. A AUGUST 2012 RNP SERIES REFRIGERATED COMPRESSED AIR DRYERS OPERATOR MANUAL RNP25 RNP35 RNP50

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

DEHUMIDIFIER DESHUMIDIFICATEUR DESHUMIDIFICADOR

Table of Contents. Specifications... page 2. Installation... page 3. Customizing... page 4. Reversing door swing... page 5

All about the Use &Care

DEHUMIDIFIERS FDK54 USE AND MAINTENACE MANUAL

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

14,000 BTU Portable Air Conditioner 14,200 BTU Heat Pump Model Number: LX-140 Operating Instructions. Model No. LX Soleus Air International

Model 1870F Dehumidifier Installation and Operating Manual

Model 1850F Dehumidifier Installation and Operating Manual

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

Power Pack Service Manual

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Portable Air Conditioner with Evaporative Technology PE6-10R-03 Operating Instructions. Model No. PE6-10R Soleus Air International

Power Pack Service Manual

All about the Use &Care

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

Utopian Portable Dehumidifier

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Portable Air Conditioner with Heat Pump Technology PH4-10R-01, PH4-12R-01, & PH4-14R-01 Operating Instructions

POWER PACK SERVICE MANUAL

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

CWR265SZ 26 Bottle Built-in Wine Cooler Owner s Manual

OUTDOOR ICE MAKER Model BIM24OS

ER MANUAL FOR YOUR BAUMATIC

DRIZAIR 110 REFRIGERANT DEHUMIDIFIER

ROTARY CONTROL AIR CONDITIONER

AIR CONDITIONER ELECTRONIC CONTROL

Transcription:

CD35 / CD35P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www.eipl.co.uk Page 1 of 12 Service Questions: Contact Ebac USA at 1-757 873 6800 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com

INTRODUCTION Designed for a wide range of applications, the CD35 is a rugged, compact unit which incorporates its own tank for collected moisture with an automatic shutoff once the tank is fully. Offices, shops, houses, restaurants and storerooms can be protected by this simple answer to humidity control. The CD35 has a number of special features: Adjustable humidistat Hot Gas defrost system with solid state controller Whisper-quiet fan Water tank with full indicator lamp All galvanized interior Exterior epoxy powder-coated finish Four independent heavy-duty castors Fully enclosed coils The fan draws the moist air through the cold evaporator coil, which cools the air below its dew point. Moisture forms on the evaporator coil and is collected in the condensate tray, which is equipped with a permanent drain. The cooled air then passes through the hot condenser coil where it is reheated using the same energy removed during the cooling phase, plus the additional heat generated by the compressor. The air is, therefore, discharged from the dehumidifier at a slightly higher temperature with a lower absolute humidity than that which entered. Continuous circulation of air through the dehumidifier gradually reduces the relative humidity within the area. The CD35 dehumidifier is a rugged, reliable drying unit designed to operate effectively over a broad range of temperature and humidity conditions. An active hot gas defrost system, controlled by an electronic timer, guarantees positive de-icing, thereby optimizing operation at low temperatures. The unit incorporates a welded and galvanized steel chassis and is finished in an epoxy coating for resilience to damage caused by rough handling. The CD35 dehumidifier is fitted with an adjustable humidistat to enable you to select the level of dryness that you desire. Page 2 of 12

SPECIFICATIONS MODEL: Ebac CD35 / CD35P HEIGHT: 22 WIDTH: 13.5 DEPTH: 14 WEIGHT: CD35 57 lbs CD35P 63 lbs AIRFLOW: 170 CFM POWER SUPPLY: 110V/ 60Hz/ 1 ph CURRENT (MAX): FAN MOTOR: COMPRESSOR: CD35 4 A CD35P 5 A 1/50 HP MagneTek Totally Enclosed ¼ HP Heavy Duty Fully Hermetic Tecumseh CONTROL: Adjustable Humidistat REFRIGERANT: R-134a REF. CHARGE: 0.17Kg CONSTRUCTION: FEATURES: 18 AWG Epoxy Power Coated galvanized steel Hot Gas Defrost down to 33 Deg. F "This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. The refrigeration system is hermetically sealed. The Global Warming Potential (GWP) of refrigerants used in products manufactured by Ebac Industrial Products Ltd is as follows R134a 1300 R407c 1610 For type and weight of refrigerant contained in this unit, please refer to the product data label" Page 3 of 12

FEATURES The Adjustable Humidistat: The adjustable humidistat enables you to maintain the required level of dryness within a room. The humidistat switches off the CD35 when the relative humidity falls to the level predetermined by the position of the humidistat control. The Water Tank: When the water tank has reached its capacity, a float mechanism will activate a microswitch lever and switch off the machine. The container-full indicator will also illuminate. Before emptying the water container, disconnect the power supply and allow the dryer to stand for five minutes. Remove the container from the rear of the unit and when emptied, replace, taking care to ensure that the float mechanism is correctly positioned. Restart unit as instructed in the following Operation section of this manual. UNPACKING & INSTALLATION After removing the CD35 from its shipping container, visually check for signs of damage. If there is evidence of damage, do not operate. Call your supplier for advice. Do not discard the packing as it will be useful when transporting the machine in the future. Wiring: Connect the power cord to a grounded single phase, 15 Amp fused, standard household wall socket. POSITIONING Single Room: Position the CD35 in the center of the room to be dried. However, if a damp patch is particularly apparent, the outlet grille should be directed towards it. If the CD35 cannot be positioned centrally, a minimum space of 6 should be allowed around the dryer. Several Rooms: To dry a number of rooms simultaneously with the most efficiency, the dryer as to be positioned between the rooms. Ensure that all doors are left ajar allowing a patch for the air to circulate to the unit. An auxiliary circulation fan would be helpful. Page 4 of 12

CONDENSATE PUMP: SPECIAL FEATURES (where fitted) The CD-35 dehumidifier unit can be fitted, either in the factory, or as retro-fit, with a condensate pump. This condensate pump will allow the unit to run unattended, with the condensate run off to a permanent drain and can be used up to 150 feet (50 meters), below the level of a permanent condensate drainage point. HUMIDISTAT CONTROL: The CD-35 dehumidifier unit is fitted with a control humidistat which measures the relative humidity of the air within the room. The humidistat incorporates a pointer and scale, which can be adjusted, and set to a relative humidity level that is acceptable to maintain the required conditions within the room. The humidistat controls the on/off function of the dehumidifier. When the relative humidity of the air in the room falls below the set point of the humidistat the dehumidifier will switch off, but when the relative humidity of the air starts to rise again and passes the set point the unit will switch on. The humidistat is used for the on/off function as it is a cost effective method which ensures power is only used when needed. TEMPERATURE CONTROLLED DEVICE: The CD-35 dehumidifier unit is fitted with a temperature sensitive device which operates in conjunction with the defrost control. In normal operation the defrost control will come into operation every 45 minutes. This is to ensure that there will be no build up of ice at lower temperatures. At very low temperatures it is still possible for the defrost device not to clear the ice completely from the evaporator coil. To ensure that even at these very low temperatures all the ice is cleared from the coil, the temperature control device will stop the fan (preventing air movement). This will increase the temperature of the evaporator coil even higher, causing all the ice to melt from the coil during the defrost mode. Where year round conditions need to be maintained, the dehumidifier unit will have to operate across a wider range of temperatures. To ensure that the dehumidifier unit operates at its most efficient, the temperature control device will restrict the defrost operation to the times when the ambient temperature falls below 25 C. Page 5 of 12

WARNING: Due to the high pressures within the refrigeration circuit, under no circumstances must direct heat be applied to the evaporator coil in an attempt to remove the build up of ice. No attempt should be made to cut open any part of the refrigeration circuit due to high pressures and gas involved. If the unit is switched off at the mains power supply for any reason, the unit must be allowed to stand at rest for at least three minutes before restarting. Failure to do so may cause the unit to blow the fuses owing to the compressor due to there being a refrigerant imbalance. Page 6 of 12

ROUTINE MAINTENANCE WARNING: ENSURE THAT THE POWER CORD TO THE MACHINE HAS BEEN DISCONNECTED BEFORE CARRYING OUT ROUTINE MAINTENACE ON ITEMS 1, 2, 3, AND 4. To ensure continued full efficiency of the dehumidifier, maintenance procedures should be performed as follows: Removal of the cover is achieved by means of four screws at the sides of the unit at base level. With the cover removed all maintenance can be carried out. 1. Clean the surface of the evaporator and condenser coils by blowing the dirt out from behind the fins with compressed air. Hold the nozzle of the air hose away from the coil (approx 6 /150 mm) to avoid damaging the fins. Alternatively, vacuum clean the coils. WARNING: DO NOT STEAM CLEAN REFRIGERATION COILS 2. Check that the fan is firmly secured to the motor shaft and that the fan rotates freely. Using mobile DD heavy medium oil, lubricate the motor bearing with 10 drops every 6 months. 3. To check the refrigerant charge, run the unit for 15 minutes and briefly remove the cover. The evaporator coil should be evenly frost coated across its surface. At temperatures above 20 C, the coil may be covered with droplets of water rather than frost. Partial frosting accompanied by frosting of the thin capillary tubes, indicates loss of refrigerant gas or low charge. 4. Check all wiring connections. IF ANY OF THE PRECEDING PROBLEMS OCCUR, CONTACT THE EBAC SERVICE CENTER PRIOR TO CONTINUED OPERATION OF THE UNIT TO PREVENT PERMANENT DAMAGE. Page 7 of 12

REPAIRS 1. Should an electrical component fail, consult the Factory Service Center to obtain the proper replacement part. 2. If refrigerant gas is lost from the machine, it will be necessary to use a refrigeration technician to correct the fault. Contact the Factory Service Center prior to initiating this action. Any competent refrigeration technician will be able to service the equipment. The following procedure must be used: a. The source of the leak must be determined and corrected. b. The machine should be thoroughly evacuated before recharging. c. The unit must be recharged with refrigerant measured accurately by weight. d. For evacuation and recharging of the machine, use the crimped and brazed charging stub attached to the side of the refrigerant compressor. The charging stub should be crimped and rebrazed after servicing. NEVER allow permanent service valves to be fitted to any part of the circuit. Service valves may leak causing further loss of refrigerant gas. 3. The refrigerant compressor fitted to the dehumidifier is a durable unit that should give many years of service. Compressor failure can result from the machine losing its refrigerant gas. The compressor can be replaced by a competent refrigeration technician. Failure of the compressor can be confirmed by the following procedure: a. Establish that power is present at the compressor terminals using a voltmeter. b. With the power disconnected, check the continuity of the internal winding by using meter across the compressor terminals. An open circuit indicates that the compressor should be replaced. c. Check that the compressor is not grounded by establishing that a circuit does not exist between the compressor terminals and the shell of the compressor. Page 8 of 12

TROUBLESHOOTING SYMPTOM CAUSE REMEDY Unit inoperative Little or no airflow Little or no water extraction Little or no defrost when required Unit vibrates excessively Water flooding inside the machine Hissing noise from the machine 1. No power to unit 1. Loose fan on shaft 2. Fan motor burnt out 3. Dirty refrigeration coils 4. Loose electrical wiring 5. Fuse blown or circuit breaker tripped 1. Insufficient air flow 2. Compressor fault 3. Loss of refrigerant gas 4. Blocked filter dryer 1. Faulty timer 2. Faulty by-pass valve 1. Loose compressor 2. Damaged fan 1. Drain pipe blocked/frozen 2. Drain pipe too high 3. Crimped or blocked tubing 4. Defective Pump 1. Machine defrosting normal operation 1. Check the power from power supply panel 1. Tighten fan 2. Replace the fan motor 3. See Routine Maintenance Section 4. Check the wiring diagram to find fault and repair 5. Replace the fuse or reset the circuit breaker 1. Check all of the above 2. Contact the Factory Service Center 3. Contact the Factory Service Center 4. Contact the Factory Service Center 1. Contact the Factory Service Center 2. Contact the Factory Service Center 1. Tighten the nuts on the compressor mounts 2. Replace fan 1. Clear the obstruction 2. Ensure that no section of the drain hose is above the level of the water outlet 3. Straighten, clear, or replace tubing 4. Replace pump N/A Page 9 of 12

CD35 SPARE PARTS LIST Part Number Description 1018611 EVAP COIL ASSY 1137907 WATER CONTAINER 2013865 MICROSWITCH SUPPORT 2013866 MICROSWITCH LEVER 2017707 HUMIDEX 7 KNOB 2131107 HUMIDEX DRAIN TRAY 2131147 CONDENSER COIL 3014272 CAPILLIARY TUBE.031 Already Cut 3020811 BY-PASS VALVE 3020937 FILTER DRYER 3033033 MICROSWITCH 3035145 HUMIDISTAT 3035346 PANEL MOUNTED TERMINAL BLOCK 3036636 RED LAMP ASSY 3040181 FAN BLADE 3050216 CASTOR 1617990 PCB 2141095 MAINS POWER CABLE 3021518 COMPRESSOR BOX COVER 3021543 OHP 3021544 RELAY 3022147 COMPRESSOR 3030421 SOLENOID COIL 3035773 MOTOR 2018641 EVAPORATOR COIL 1600500 PCB (Pre-95 Model) 3030275 110V RELAY (Pre-95 Model) 2013837 DRAIN TRAY Spare parts available online www.eipldirect.com Page 10 of 12

LIMITED WARRANTY Our products carry a one-year unconditional warranty against any defects in workmanship or material. This warranty will cover all parts and labour required to repair your Ebac product. This warranty is invalid if the unit has been abused, damaged, whether intentional or accidental, or if any modifications have been made to the unit. THE FOREGOING WARRANTY IS EXCLUSIVE AND IS ISSUED IN LIEU OF ALL OTHER WARRANTIES (WHETHER WRITTEN, ORAL, OR IMPLIED) INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. EBAC INDUSTRIAL PRODUCTS, INC. DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL DAMAGES, LOST PROFITS, OR INCIDENTAL DAMAGES FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THE FOREGOING DESCRIBED MERCHANDISE. For Your Records: Model: S/N: Date Received: SAVE THIS SECTION FOR YOUR RECORDS CLIP AND RETURN THIS CARD PLEASE NOTE To ensure that your Ebac Dehumidifier is accorded the full coverage provided by this warranty, please complete and mail this card at your earliest convenience. Thank You WARRANTY REGISTRATION DATE MODEL S/N RECEIVED OWNER ADDRESS CITY STATE ZIP COMMENTS Ebac Industrial Products. 700 Thimble Shoals Boulevard, Suite 109, Newport News, Virginia. 23606-2575 Page 11 of 12

UK Head Office Ebac Industrial Products Ltd St Helens Trading Estate Bishop Auckland County Durham DL14 9AD Tel: +44 (0) 1388 664400 Fax: +44 (0) 1388 662590 www.eipl.co.uk sales@eipl.co.uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd. Suite 109, Newport News Virginia, 23606-2575 USA Tel: +01 757 873 6800 Fax: +01 757 873 3632 www.ebacusa.com sales@ebacusa.com German Sales Office Ebac Industrial Products Ltd Miraustra 64 66 13509 Berlin Germany Tel: +49 3043 557241 Fax: +49 3043 557240 www.eip-ltd.de sales@eip-ltd.de Page 12 of 12 Service Questions: Contact Ebac USA at 1-757 873 6800 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com