DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

Similar documents
DIVISION 08 OPENINGS HARDWARE AND KEYING PART 1 - GENERAL 1.01 SUMMARY

DOOR HARDWARE SECTION DESIGN REQUIREMENTS GENERAL INFORMATION

SECTION DOOR HARDWARE

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

UBC Technical Guidelines Section Edition Door Hardware Page 1 of 7

SECTION HARDWARE

SECTION DOOR HARDWARE

2. Interior doors shall be not less than 18 gauge steel.

APPENDIX F: LOCKSETS AND ACCESS CONTROL

Architect s Specification Guideline:

University of Rochester October 17, 2008 Brooks Landing Business Center

ONONDAGA COMMUNITY COLLEGE FERRANTE HALL RENOVATIONS - PHASE

Title Page Table of Contents Instruction to Bidders Form of Proposal Equal Opportunity Statement Form of Guarantee Supplemental General Conditions

B. Shop Drawings: Details of electrified door hardware, including wiring diagrams.

C. Thresholds, weatherstripping, seals and door gaskets. A. ANSI/ICC A117.1 Standard for Accessibility and Usable Buildings and Facilities; 1998

SECTION DOOR HARDWARE

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011

BuildingName The Description of the Project P DOCUMENTS

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

SEQUOYAH SCHOOLS FI&R 06 G01 Cherokee Nation Tahlequah, Oklahoma

About the Instructor & Presenter:

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project]

Securing your school. Door hardware solutions for primary education

Security & Life-Safety For Schools

ABLOY EFEND. New name for security

HALIFAX HUMANE SOCIETY ADDITIONS AND ALTERATIONS. B. See Division 08 door sections for astragals and door silencers.

FINISH HARDWARE FOR ADDITIONS, RENOVATIONS, AND REMODELINGS. A. Provide finish hardware including necessary accessories.

SECTION FINISH HARDWARE

ADDENDUM - 01 REGAN YOUNG ENGLAND BUTERA

Security & Life-Safety For Schools

Lake County / Multi-Department Storage Facility / Project / December 05, 2016 SECTION DOOR HARDWARE

Table of Contents Auxiliary Locks

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

B. After installation, the Owner shall be able to perform hardware configuration changes as desired without the services of the Integrator.

v.3.1: December 19, 2014

SECTION DOOR HARDWARE

EPlex 5000 Series MONACO LOCK COMPANY, INC. TEL (800) FAX (800)

SECTION DOOR HARDWARE HSC Guide Specification for Capital Construction. [Adjust to Suit Project and Confirm with University Lock Shop]

DOOR HARDWARE

1800 Series Flatbar Exit Devices

USD 380 Centralia, Frankfort & Vermillion

Job No. EGOS

New Bedford, Massachusetts Tel: (617) CBI Job No.: Fax: (617)

SECTION &.40 DOOR HARDWARE

TAB C-6 KEYLESS ACCESS AND SECURITY SYSTEM GUIDELINE

WVU DESIGN GUIDELINES & CONSTRUCTION STANDARDS DIVISION 28 ELECTRONIC SAFETY AND SECURITY

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

Feb H: FINISH HARDWARE

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

CONSULTANT PROCEDURES & DESIGN GUIDELINES ACCESS CONTROL SYSTEM

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Cylindrical Lever Lock

SECTION DOOR HARDWARE

DIVISION 8 - DOORS AND WINDOWS. A. This division contains the following elements:

Product Catalog. 8X Line Cylindrical Knob Locks

CL3800 Series. Standard-Duty Key-in-Lever Locksets

SECTION DOOR HARDWARE

6 Line Knob. Table of Contents. Specifications. MicroShield Coating. Certification Compliance. On the Cover

Developing a Healthcare Facility Fire Door Inspection Program

PROJECT NO. CWA SEPTEMBER 24, 2014 ADDENDUM NO. 6 BESSEMER RECREATION & WELLNESS CENTER

SECTION INTEGRATED DOOR ASSEMBLIES

106. LOCK AND CARD ACCESS GENERAL DESIGN INFORMATION

Card Access Control Specifications

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

Doorway Solutions for Multi-Resident Facilities. Apartments, Condominiums, Mixed Use & Assisted/Senior Living

SECTION DOOR HARDWARE

1-300 Fire and/or Smoke Dampers to Inspect $ Fire and/or Smoke Dampers to Inspect $34.30

Behavioral Health Series

Fire Rated Door Assemblies: Compliant Designs

YALE LOCKSETS. Yale Locksets offer protection and convenience for your business, home and your family.

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

Bored Lock. SARGENT Manufacturing Company 2003, 2004, 2007 All rights reserved

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

THE LEDGE AT CABOT DRIVE. NASHVILLE, TN

1. Commercial door hardware for the following: a. Swinging doors. b. Other doors to the extent indicated.

SARGENT Beacon TM. A Technical and Informational Newsletter From Dugmore & Duncan. Summer 2009 Vol. VIII - Issue II L

An ASSA ABLOY Group brand Series. Grade 2 Cylindrical Knob Locks

An ASSA ABLOY Group brand. 4800LN Series. Interconnected Locks

WHAT TO EXPECT DURING A FIRE DOOR INSPECTION

Laura Frye, AHC, CSI, CCS, FDAI Technical Director, DSSF Director of Certification, DHI

Alarmed Exit Hardware

Ironmongery Schedule. Prepared for: ABC Architects Project Title: Transport Vertcial Market Our Ref: ABC123

Glass Solutions Sweets Brochure

Pilfergard Door Alarms

Hardware Selection Process

ED3000 Series. Crossbar Exit Devices

CK4300 Series. Cylindrical Knob Locksets

System Design and Overview Document

Series 98/99. All Series 98/99 are available with antimicrobial coating. (Page 38 for more detail) OPTIONS AND ACCESSORIES. Touchbar Exit Devices

ARCHITECTURAL IRONMONGERY. company overview

TABLE OF CONTENTS GENERAL... 2 A. DEFINITIONS DIGITAL, ADDRESSABLE FIRE ALARM SYSTEM... 2

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

Vanilla Box Design Criteria

NFPA 80 Overview January 21, 2016

Security Professional Mobile Showroom. Product Training

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR

DIVISION 28 ELECTRONIC SAFETY AND SECURITY

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

Transcription:

08 70 00 PART 1 - GENERAL 1.01 SUMMARY A. Section includes the design and coordination for all necessary hardware and coordination for all doors. Hardware shall include but not necessarily be limited to the following: 1. Hinges 2. Lock Cylinders and Keys 3. Lock and Latch sets 4. Bolts 5. Exit Devices 6. Push/Pull Units 7. Closers 8. Holders 9. Dust Proof Strikes 10. Protection Plates 11. Weatherstripping 12. Thresholds 13. Cylinders 14. Electric Strikes 15. Silencers B. Consultant shall specify which hardware is not included under this section, and shall ensure that hardware not specified under this section is clearly specified in the pertinent section.

08 70 00 C. IMPORTANT: Locks, cylinders, exit devices, door closers/auto operators, and key systems outside of those specified in this section are not allowed in any WSU project without authorizing signatures of both a WSU Key Shop Representative and the WSU Facilities Services Maintenance Director. 1.02 DEFINITIONS A. Finish Hardware is defined to include all items known commercially as Builder's Hardware as generally required for, but not limited to, swing doors and pocket doors. The consultant shall also include all necessary hardware definition specific to project. These may include but not limited to cylinders for elevators, overhead coiling doors and grilles, electrical panels, fire alarm panels, control panels, and fire extinguisher cabinets. 1.03 DESIGN REQUIREMENTS A. Coordinate height of panic bar devices with location of lower edge of vision panels to minimize use of spacing shims and minimize occlusion of glass surface by panic bar. (Glass lights are difficult to clean and replace when blocked by the panic device.) 1.04 WARRANTY A. Specify the following warranty requirements: 1. Locks and Latches: 5 years 2. Closers: 5 years 3. Automatic Door Openers: 5 years 1.05 MAINTENANCE A. Extra Material: 1. Include one gross of extra key blanks for Major Capital Projects. Deliver directly to the WSU Key Shop (coordinate through the WSU Construction Manager). 2. Provide two percent additional spare locksets or five of each type, whichever is more. B. Tools and Manuals: 1. With the delivery of permanent keys, Contractor shall deliver to the WSU Key Shop two complete sets of adjustment tools and one set of

08 70 00 PART 2 - PRODUCTS maintenance manuals for locksets, closers and panic devices in accordance with project close-out requirements. Coordinate turnover of materials to the Key Shop through the WSU Construction Manager. 2.01 MANUFACTURERS A. Specify each similar item from a single manufacturer, unless deviation is specifically approved by the WSU Project Manager and WSU Key Shop. WSU maintains a standardized key and locking system, and minimizing the number and variety of stocked repair parts is a priority. B. Locksets: Acceptable manufacturers: Location Item/Manufacturer Substitute Classrooms & Teaching Labs (see Note 1 below) Cylindrical: Schlage ND73 F90 Mortise: Schlage N9456 F13 Exit Device: Von Duprin 99-2 Classrooms & Labs (Card Access) (see Note 1 below) Offices Entrance Doors Dormitory Rooms Mechanical Spaces Utility Tunnel to Building (see Note 2 below) Roof Access Access Doors & Panels Electrical Panels Fire Alarm Panels Cylindrical: Schlage AD400-CY Mortise: Schlage AD400-MS Exit Device: Schlage AD400-993 Cylindrical: Schlage ND73 F90 Mortise: Schlage N9456 F13 Cylindrical: Schlage ND53 F109 Mortise: Schlage N9453 F20 Schlage functions determined by Housing and Dining Services Key Shop Cylindrical: Schlage ND80 F86 Mortise: Schlage L9080 F07 Cylindrical: Schlage ND80 F86 Mortise: Schlage L9080 F07 Cylindrical: Schlage ND80 F86 Mortise: Schlage L9080 F07 Schlage Large Format Interchangeable Core 1347 Keyway Corbin Cabinet lock with TEU-1 number Corbin Cabinet lock with "B" Key

08 70 00 C. Other Hardware: Acceptable Manufacturers: Item Manufacturer Substitute Butts/Hinges Ives (Non-Removable Hinge Pins) Stanley (Non- Removable Hinge Pins) Continuous Hinges PEMKO Heavy Duty Roton Heavy Duty Lock Cylinders Schlage Everest D145 Key System Schlage Everest D145 Surface-mount Door Closers Floor-mount or Overhead Door Closers Automatic Door Openers (Exterior) Automatic Door Openers (Interior) LCN 4040XP Norton 6060 Norton 6060 Panic Devices Von Duprin 99/33 Motion Access Condor No vertical rod exit devices Dummy Panic Devices Von Duprin 350 Electric Strikes HES 9400/9600 Securitron MUNL/UNL Mullions (Locking) Stanley Von Duprin Thresholds / Weatherstrip PEMKO Silencers PEMKO Auto Flushbolts Glyn Johnson Coordinators Glyn Johnson Kick Plates and Pulls Special Locks Ives Match existing

08 70 00 Magnetic Hold Opens Wall Stops Push Plates Key Storage Cabinet Padlocks Fire Extinguisher Cabinet Locks See 28 31 00 Fire Detection and Alarm Ives Ives Key Shop approval Schlage KS23 with 1347 Keyway See 10 44 00 Fire Extinguishers and Cabinets Telecommunications Closets Schlage 1347 Keyway Restrooms Lockable deadbolt Schlage Everest D145 Keyway Keyboxes Knox Box Note 1: All classrooms and teaching labs shall be equipped to secure the room from the inside. See specifications in 2.02 below. Note 2: All Utility Tunnel to Building door hardware shall include a door closer and the hardware identified above. 2.02 MATERIALS A. General 1. Mortise-type locks are only acceptable as like substitutions during renovations of existing facilities. They are not acceptable in new construction. 2. Non-removable hinge pins are preferred, and are mandatory on all exterior doors. 3. Lever type hardware shall be installed everywhere public access is required. The use of door knob hardware is prohibited. 4. Furnish silencers for door frames, except at weather stripped doors and doors with light seals, sound seals, or smoke gaskets. Furnish snap-in type silencers, 3 per single door, 4 per pair of doors.

08 70 00 5. Surface-mounted door bottoms are required, due to ease of maintenance and replacement. Recessed door bottoms are prohibited. Verify height and thickness. Fasten with flush screws. 6. Provide kickplates at both sides of wood doors at heavily traveled corridor areas, laboratories, equipment rooms, stairs, kitchen doors, gymnasiums, toilet rooms, classrooms and where required by ADA codes. Wood doors are of particular concern, but consider these at metal doors as well. Stainless steel is the preferred material. 7. Floor stops are not permissible. They are difficult to clean around and constitute a tripping hazard. Where a stop is desired at exterior doors in series, provide a 4 inches x 3 feet-0 inches high concrete filled metal bollard to accept the door stops (structural steel tubing may be considered for architectural purposes). These are preferable to stop arms provided as part of the closer assembly. 8. All wall-mounted hardware shall have solid backing. 9. Knox Boxes are required by the Fire Marshall. These shall be recessed into the wall adjacent to the main front entrance doors. In renovation projects where conditions prevent recessing the box, it may be through bolted to the front face of the main entrance doors. In either case, verify location and mounting elevation with the Fire Marshall. 10. Provide one coat hook on the back of each office door. 11. Provide pulls and push plates on all doors having push-pull operations. Standard push and pulls are recommended over high-maintenance custom designs. 12. Closure arms shall not extend into corridors where they can be vandalized or broken. 13. Use Phillips type flat - head screws to match hardware finish. 14. Do not use "through bolts" where the head is not exposed. Use machine screws or concealed fasteners. 15. Provide fasteners that are compatible with doors and hardware which will not cause corrosion of door or hardware. 16. Provide threshold with positive anchoring device. Set thresholds in a caulking compound. 17. Coordinate key requirements with WSU Key Shop for all telecommunication room locks, all mechanical room locks and roof access

08 70 00 door locks. These locks have a WSU standard separate keying requirement which must be verified with Key Shop prior to final hardware design. These locations may require different a lock manufacturer. B. Classroom / Lab Door Lock Requirements 1. To increase security in the event of an active threat, so that rooms can be secured from the inside, classroom and lab doors shall be equipped with the Schlage ND73 F90 Corridor lock, Schlage L9456 F13 Mortise Corridor lock (renovations only), the Schlage AD400 card swipe, or the Von Duprin -2 Double Cylinder Exit Device. 2. Standard Schlage Corridor lock specifications: i. Lock or unlock by key from outside. ii. Push-button locking from inside. iii. Turn inside lever or close door to release button. iv. When outside lever is locked by key, it can only be unlocked by key. v. Inside lever is always unlocked. 3. Schlage AD400 card swipe lock specifications: i. See electrical and installation specifications in section 28 13 00 Access Control. ii. Push-button locking from inside. iii. Turn inside lever or close door to release button. iv. Inside lever is always unlocked. 4. Von Duprin -2 Double Cylinder Exit Device specifications: i. Thumb turn (not keyed cylinder). C. Electrical Items 1. Electric door strikes are preferable over electrically operated hardware. This allows for better coordination with security systems. Consult with the Project Officer and the WSU Key Shop prior to specifying. 2. Provide magnetic hold opens at area separation doors. See technical requirements in section 28 31 00 Fire Detection and Alarm. 3. Provide automatic door openers at all main building entries. i. Other locations (e.g., assembly areas) shall be reviewed on a site-bysite basis. ii. Coordinate door openers with security system.

08 70 00 D. Keying 1. Key schedule will be provided by the WSU Project Manager or designated Facilities Services representative. All cylinders shall be keyed by the WSU Key Shop. 2. Requirements for change keys, master keys and grand master key locks and cylinders shall be determined by the WSU Key Shop. 3. All new cylinder items shall be keyed according to the WSU Key Shop s direction. In addition, the hardware supplier shall furnish new "Schlage Everest D145" cylinders for all existing locks, unless otherwise directed. The hardware consultant shall perform a field survey, in conjunction with the WSU Key Shop, to verify type and quantity required for a complete and operational system. 4. All cylinders for new construction will be Schlage Everest D145, unless otherwise directed. 5. The Contractor shall supply temporary cylinders for the exterior doors in new construction and a minimum of six (6) each temporary cylinders for the interior doors for contractor security during construction. These temporary cylinders shall be the same type specified for the completed work but keyed separately from any key system on campus. The WSU Key Shop will return these cylinders to the Contractor at the completion of the project. The cylinders may be repinned and used at a later date. 6. All grand masters, master and key alikes are to be delivered to the WSU Key Shop. of these keys should be delivered to the project site. 7. At the conclusion of the project, Contractor shall deliver all individual keys on a clearly marked key board to the WSU Key Shop (coordinate through the WSU Construction Manager). Alternatively, keys may be sent directly to the Key Shop if each key envelope is marked with the door number it operates. E. Construction Keying 1. Contractor shall furnish a construction master key system for locks and cylinders. 2. The contractor will be allowed to use only the construction keys during construction. 3. The WSU Key Shop will install the permanent cylinders and turn over construction cylinders to the Contractor at the close of the project, unless

08 70 00 otherwise directed by the WSU PM or CM. 4. When the General Contractor is allowed to install the permanent cylinders, the Contractor shall sign out copies of the permanent keys from the WSU Key Shop during installation. However, if a permanent master key is lost or stolen during construction, the Contractor shall rekey all cylinders and provide new keys at his own expense. All keys shall be returned to the WSU Key Shop upon request or at the completion of the project. 5. Upon substantial completion of the work, the contractor shall void the construction key system and demonstrate that the specified key system is operating properly. 6. For renovation or remodel work, the General Contractor will establish a Key Coordinator System. All keys required by subcontractors will be obtained through the General Contractor's Key Coordinator. Project retainage will not be released until the General Contractor returns all keys to the WSU Key Shop. F. Closers 1. All exterior doors shall have adequate closers to protect against strong winds (suction) and slamming. 2. All closers shall be attached with sex-bolts. 3. Do not use floor/overhead concealed closers. 4. Provide closers with a maximum pull force required per the ADA. G. Panic Devices 1. Panic Devices are to be provided for exit doors only where required by code. 2. On single doors and on one door in multiple openings, provide cylinder operated by key from outside unless otherwise directed. Door is to be permanently locked from the outside. During the time when the building is to be open to the public the panic device is to be "dogged down" from the inside. 3. Provide single and double door entries with heavy duty "rim type" panic devices. Double door entries should be provided with removable mullions. H. Butts 1. Use heavy duty, ball bearing butts on all exterior doors and on interior

08 70 00 doors which receive moderate to heavy use. 2. Number as recommended by the manufacturer. Minimum of 1-1/2 pairs of 4-1/2 inch x 4-1/2 inch on all doors. I. Weatherstripping 1. Weatherstripping is required on all exterior doors. 2. Do not specify or use interlocking thresholds. J. Identification and Delivery 1. Permanent keys shall be factory stamped "Do Not Duplicate." 2. Permanent keys shall be identified with tags, and sent directly to the WSU Key Shop from the factory, by registered mail or receipt personal delivery. 3. Require a fully labeled and lockable metal key storage cabinet for each project. Coordinate cabinet type, size and location with the WSU Project Manager. PART 3 - EXECUTION 3.01 ADJUSTING A. Require the Contractor to adjust the operation of all doors to meet ADA requirements for opening force. B. The operation of the ventilation system shall not cause doors to slam shut or fail to close completely. END OF SECTION