Stratomaster Smart Single

Similar documents
Stratomaster Smart Single

Stratomaster Maxi Single

The EGT-1 is a single channel fully programmable digital EGT (Exhaust Gas Temperature) gauge.

Temperatures can be displayed in degrees Celsius or degrees Fahrenheit from -100ºC to 1200ºC (-148ºF to 2192ºF).

The TC-2 also records maximum temperatures reached for each channel in permanent memory.

The TC-1 also records maximum temperatures reached for each channel in permanent memory.

Stratomaster Ultra. Owner's Manual. Installation guide. Stratomaster Ultra L Owner s manual. Model L MKII with RDAC V EIS.

Blaze INFO-2. Information Display

PPG meter instrument for power paragliding

ND4000 Manual Marine Hydraulics

User and Installation Manual. Your journey, Our technology

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

DIGITAL METERS Large Display Temperature Meters Instruction Manual

Digital Marine Exhaust Temperature Alarm

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Introduction. OM-THA2

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

D-TEK -MS Vehicle Loop Detector. Operating Instructions

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Temperature Data Logging

DE20 INSTRUCTION MANUAL

Module Features are-configurable, no module jumpers to set

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

NOVALYNX CORPORATION MODEL 200-WS-21-A DUAL SET POINT WIND ALARM INSTRUCTION MANUAL

OVERVIEW ANNUCIATOR POINTS

Operating Instructions

OPTIONAL SLIT TUBING RECOMMENDED (AVAILABLE AT MOST HARDWARE STORES) Violet Grey. +12v Dash Lighting (See Lighting Mode)

Line Voltage Non- Programmable Thermostat Installation Instructions & User Guide

Corporate Profile. needs and product demands. CON 08X /03 Rev 0

ABB Instrumentation. Specifications. COMMANDER 150 Universal Process Indicator. the 1 /8 DIN indicator to match all your display requirements

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

EST User Manual. (Please read this manual carefully before using)

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

CA5000 Liquid CO 2 Freezer Backup System

Instruction Manual PCS-400-XY. Pump Controller. Y=2: 4-20 ma Y=6: 0-10 VDC X=5: 1-5 VDC. 4 Pump Control Relays 1 Alarm Relay 1 Signal Fail

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Exercise 2-4. Heat Exchangers (Optional Exercise) EXERCISE OBJECTIVE DISCUSSION OUTLINE. Description of a brazed plate heat exchanger DISCUSSION

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

User manual and installation guide

Pump-Down Controller MODEL 4052

Operating Instructions

ETO 2 - Controller for ice and snow melting

ENGINEERED PARKING SYSTEMS MODEL 3416D

Oxygen & Carbon Dioxide Analyser

EasyLog Data Logger Series

Software Version 2.01 LEVEL MONITOR MODEL 220

Oxygen & Carbon Dioxide Analyser

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

TMC. Installation and Operation Manual TMC. Temperature and Pressure Monitoring for Heating and Cooling Applications. Temperature Monitoring Control

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

User Guide

GG-2 2-CHANNEL GAS DETECTION CONTROL PANEL. Installation and Operation Manual

Dryer Master DM510 Commissioning Guide

Isolated Thermocouple Module

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

EEM 451 Industrial Control Systems Sensors and Actuators-II. Dept. of Electrical-Electronics Eng. Anadolu University, Turkey

RTD TEMPERATURE SENSING SYSTEM

JENCO ELECTRONICS, LTD.

Operator: Save these instructions for future use!

Pump-Up Controller MODEL 4062

Analog Room Pressure Monitor RPC Series

ACL TC 200 TEMPERATURE CONTROLLER

User manual and installation guide

ANALOX 3000 Carbon Monoxide Monitor

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

Dryer Controller M720

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Installation Instructions / User s Manual TSTAT0406 and TSTAT0408

Operating Instructions

INSTRUCTION MANUAL T119 1MN0110 REV. 0. operates with ISO9001 certified quality system

EXPERT TRI-STAR. Temperature controller. User s Manual

VT4810 SINGLE / DUAL ZONE CONTROLLER INSTALLATION MANUAL

DCU 305 R2/R3. Troubleshooting Manual

DFM. flow pressure temperature MULTI PARAMETER DIGITAL MASS FLOW METERS. Totalizer. Interface

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

QD6310. Fixed Gas Detector Operation Manual

Lynx Smart Satellite Sensor Kit

R E N HI ITI CUSTOM AN LO +12v ADJUSTMENT

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Mark 25 Ultrapure Water Conductivity Analyzer

LC2610 Level Controller Installation and Maintenance Instructions

Operation Manual. Winding Turns Tester MODEL: TH-201/TH-201R. Changzhou Tonghui Electronic Co., Ltd.

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

MODEL 5100 VOTING LOGIC MODULE

NT DUAL CHANNEL DISPLAY. User Guide

Important Supplementary Manual to the main Ezeio manual. 5. Section 2a: Introducing the 2400 input and output expansion field stations.

LC2200 Level Controller Installation and Maintenance Instructions

ET10 Series Stand-alone LCD Fan Coil Thermostat

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

Wireless Color Weather Station

METAL SHARK COMBI Flat metal detector for textile and non-woven products. Metal sensitivity from Fe 0,3 mm

VENSTAR T1070 FAN COIL THERMOSTAT PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

TEMPERATURE CONTROLLER (STANDARD MODEL)

Transcription:

Stratomaster Smart Single EMS-503 Fully integrated Engine Monitoring System for the Rotax 503 DCDI and similar two-stroke engines such as available from Hirth, 2SI and others. The EMS-503 unit is a 2.25 instrument incorporating all that is needed to accurately monitor the performance of a Rotax 503 DCDI engine. Included functions are: 2 channel EGT gauge (Exhaust gas temperature) 2 channel CHT gauge (Cylinder head temperature) Digital engine RPM display Engine hobbs meter (can be set to current engine time) Engine running timer (can be used as flight timer), resettable to zero at any time. External alarm output to switch a lamp in case of exceeded temperature(s). Flashing on screen alarms.

Setting up the EMS-503 Press the Menu key to enter the menu. You can move forward and backwards in the menu by using the + and keys. To change or select a menu item, move the highlight to the desired item and then press the Menu key. To end an edit or function, press the Menu key again. To exit the menu and continue normal operation, select the ***Done*** function and press the Menu key. Note, all changes you have initiated during your session will only be remembered by the instrument if you exit the menu using the ***Done*** function. Zero FT This function allows you to set the flight timer to zero. The flight timer counts hours and minutes while the engine is running. Set Hobbs This function allows you to set the hobbs meter to your current engine running time. Use the plus and minus buttons to change the indicated part of the hobbs reading. Use the Menu button to change from hour hundreds to hours to minutes. Moving the update cursor below the numbers past the minutes field on the right ends the edit of the hobbs meter reading and stores any changes. Temp in Choose your temperature units. You can select Degrees Celsius or Degrees Fahrenheit.

Contrast This function allows you to change the display contrast to your liking. You can select values from about 20 to 45. Values may vary with display types. Calib... Enter the number of pulses per revolution. You can enter fractions of a pulse in case of engines that generate a non-integer number of pulses per revolution. Typical settings: Rotax 503 DCDI 6.0 Rotax 503 Single ignition 1.0 or 2.0 depending on wiring BL This function allows you to switch the display backlight on or off. ADC This function is for technical personal. It is not used for ordinary operation of the unit.

Technical specifications: Display temperature range (operational): -20 to +80 degrees C Supply voltage: +8 to +18V. +24/28V with optional pre regulator. Supply current: 25mA/45mA (backlight off/on) Thermocouples: K-type Measurement range EGT: 0 to 700 degrees C (digital to 1200 degrees C) Measurement range CHT: 0 to 300 degrees C (digital to 1200 degrees C) Alarm level EGT: 650 degrees C Alarm level CHT: 250 degrees C Technology: Fully cold junction compensated using precision internal temperature reference. Measurement accuracy: +/- 5 degrees typical over full temperature range if used with Stratomaster EGT and CHT probes. Measurement interval: 2 seconds per channel. Inputs: Differential, can use grounded and isolated probes. Common mode voltage range: -2V to +3V Alarm contact: Maximum permissible current through alarm contacts: 500mA. Maximum permissible voltage over alarm contacts: 50V. Typical load for alarm contacts: 12V/1W lamp. Be aware of low resistance of higher wattage lamps. A cold filament resistance of 20 ohms or less will damage the internal alarm relay contact. Rev counter: Crystal based accuracy, resolution 20 RPM typical, dependent on number of pulses per revolution from engine and "Calib" setup. Range 0-9999 revs. Minimum signal for stable display: 2Vpp. Fully A/C coupled, maximum voltage +/- 40V. RF noise filter plus Schmidt trigger based input. Note: It is essential that a single wire be connected from the reference terminal of the instrument to the engine block (brown wire on Rotax 503 DCDI engines). This wire must not be used to share currents with other electrical users as this will affect accuracy of indicated temperatures. Warranty: MGL avionics warrants their products for a period of one year from date of purchase against faulty workmanship. Warranty is limited to the replacement of faulty components and includes the cost of labor. Shipping costs are for the account of the purchaser. Note for operation on supplies with inductive loads: Any operation of electronic instrumentation on power supplies that are subject to high voltages caused by operation of inductive loads (starter motors, solenoids, relays) are required to be fitted with suitable protection. All Smart Singles are guaranteed to withstand temporary over voltage up to 40V without additional protection. We recommend that measures are taken to prevent voltage transients in excess of this limit. MGL Avionics recommends the fitment of a fuse in line with a 33V transorb (available from MGL Avionics at low cost) to protect electronic instruments, radios and intercom systems. Only one such arrangement is required for a cluster of instruments. Please note that product warranty excludes damages caused by unprotected, unsuitable or incorrectly wired electrical supplies.

Installing the EMS-503 The two CHT probes and two EGT probes are wired as shown above. Connect probes according to the colors of the wires. These are red and yellow for MGL probes. Shown is typical wiring used to connect a 12V lamp as external alarm indicator. Note that the two terminals used for the alarm are the contacts of a switch. The switch is closed when the alarm is active. If you have more than one instrument with alarm contacts, you can wire all contacts in parallel so you can use a single lamp if so desired. A 12V/0.5W or 1W lamp is the usual choice. Power supply here assumes a 12V DC source. It is recommended to install suitable protection against over voltage such as can be generated by solenoids and starter motors. The above suggestion uses a fuse and a transorb. The transorb is available from MGL Avionics at very low cost. This device ensures that the voltage across it cannot rise above 33V, the transorb will cause the fuse to blow if prolonged over voltage is present. Note that you only need a single fuse and transorb to protect a cluster of several instruments. Please install the transorb as close as possible from a wiring point of view to the instruments. You can use the protected power for your radio, intercom or other low current users. Keep this power rail separated from high current rails for lamps etc. Be sure to install a reference connection between the minus terminal of the instrument and the engine block. On the Rotax 503, this is available on the connector block as the Brown wire. Finally, connect the Grey REV counter wire as shown above. Should you find unstable RPM readings, you may have a burned magneto coil. This can happen if you have used low impedance rev counters before. In this case you can try fitting a 220 ohm resistor from the grey wire to the brown wire. Alternatively, you can connect the REV counter terminal to one of the yellow lighting coil wires if you have a rectifier/regulator fitted.

Extending leads of probes and senders Thermocouple leads as used with the EGT and CHT probes can be extended either with ordinary copper cable or with special K-Type extension cable. The choice of either depends on your desired accuracy. If it is possible in your installation to ensure that both ends of a copper extension cable will be at the same temperature (or very close), then it is quite possible to use the copper cable. In most open-air installations this will be the case. Should this not be possible or you require best possible accuracy at all times, you can obtain a special K-type extension cable. This cable is made from the same metals as your probes cable but uses ordinary plastic sleeving to save costs. In either case, ensure that the cable is not routed close to sources of electromagnetic interference of any kind. The voltages present in this cable are very small and are subject to changes applied by external fields. This can lead to false temperature indications. You can check your installation by using a hand-held transmitter, such as an airband radio. If you transmit a signal, no change in temperature reading should occur.