Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

Similar documents
ITALIAN STANDARD UNI 11565

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

ARGE Guideline - Part 1 "Fire detection in rolling stock"

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

FIRE CONTAINMENT AND CONTROL SYSTEMS

WATER MIST FIRE PROTECTION SYSTEMS FOR INDUSTRIAL CABLE TUNNELS AND TURBINE HALLS

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Experts in Fire Protection

International Water Mist Conference, Istanbul October 22-23, 2014 The background and development of the guidelines in IMO Resolution A.

ARGE Guideline - Part 3 "System functionality fire detection and fire fighting systems in rolling stock"

designed for rail 5000 Series

Aspirating Gas Detection CFD Modelling Predicts Application Performance

and Sprinkler System in Resalat Tunnel of Tehran

DETERMINATION OF SMOKE QUANTITIES TO BE USED FOR SMOKE DETECTION PERFORMANCE GROUND AND FLIGHT TESTS

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

Recent European and national German regulations for. measures

BUS ENGINE COMPARTMENT FIRE PROTECTION SYSTEM FIREPRO TEST REPORT PEER REVIEW

An experimental study of the impact of tunnel suppression on tunnel ventilation

REVISED GUIDELINES FOR THE DESIGN AND APPROVAL OF FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR RO-RO SPACES AND SPECIAL CATEGORY SPACES

ON-TRACK FOR TAILORED FIRE PROTECTION. Future-proof fire protection solutions for rail vehicles

Large-scale fire test for interior materials of the Korean high speed train

Fire Protection for Printing Machines with High Pressure Water Mist

AUTOMATIC FIRE EXTINGUISHING and VISUAL GUIDE SYSTEMS for TUNNEL PROTECTION

The Protection of Machinery Spaces by means of the Local Application of Water Mist. Dr. Tim R. Nichols CPhys FIFireE

AUTOMATIC FIRE EXTINGUISHING SYSTEM for TUNNEL PROTECTION with SPREAD REMOTE CONTROLLED MONITORS (TUDEM-LEGIO)

The development of seat fire testing for EN Richard Nowell

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

SIGNALISATION AND VISUAL GUIDE INTERACTIVE SYSTEM for EVACUATION ROUTES in TUNNELS and CONFINED AREAS

Directories. B.1 Keyword Directory B.2 Tables B.3 Figures B.4 End Notes Fire Safety Guide / Siemens Switzerland Ltd

Underground fires in metro systems failures, accidents and terrorism

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection. designed for rail 1

Hot Issues in Fire Engineering 28 February 2012

Moving Target: A Case Study in Providing Fire Protection Below a Reconfigurable Concert Hall Seating System. Part 1: Concept Design

TUNPROTEC. Active Tunnel Fire Protection

26 June 2001 *** I:\CIRC\MSC\1007.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

Fire Detection and Alarm System (FDAS) & Fire Detection and Suppression Systems (FDSS) for Buses - Requirements

UL268 7 th challenge with single infrared smoke detector

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Experts in Fire Protection

Interaction of Water Extinguishing Systems and Smoke and Heat Exhaust Ventilation Systems (SHEVS)

Detection of Fires in Heavy Duty (HD) Vehicles

GUIDELINES FOR THE APPROVAL OF EQUIVALENT FIXED GAS FIRE-EXTINGUISHING SYSTEMS, AS REFERRED TO IN SOLAS 74, FOR MACHINERY SPACES AND CARGO PUMP-ROOMS

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

Fire protection for rolling stock. Innovative solutions from Siemens Building Technologies. Answers for infrastructure and cities.

Method for testing the suppression performance of fire suppression systems installed in engine compartments of buses and coaches

Experimental Room Fire Studies with Perforated Suspended Ceiling

Report on Public Input June 2014 NFPA 101

FIRE PROTECTION OF ROLLING STOCK Christoffer Nylander

Availability, Reliability, False Alarm Resistance Best Practice in Fire Alarm Systems. FIRE PROTECTION OF ROLLING STOCK 2 rd March 2017

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

THE REPUBLIC OF LIBERIA LIBERIA MARITIME AUTHORITY

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

First Revision No. 6-NFPA [ Section No. 2.2 ]

Certificate No: EWS534

Finalized Draft AUTOMOTIVE INDUSTRY STANDARD

Finalized Draft AUTOMOTIVE INDUSTRY STANDARD ARAI

J. R. Qualey III, L. Desmarais, J. Pratt Simplex Time Recorder Co., 100 Simplex Drive, Westminster, MA 01441

Laboratory fire experiments with a 1/3 train carriage mockup

Water Mist and Heritage Buildings Case - St. Mark s Dome, Venice

BUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST

Revision process of EN 45545

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

Proven Fire Fighting Efficiency for Large Transformers with High Pressure Water Mist

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Economic and Social Council

The first tunnel fire. Benefits of fire

Sprinklers Modeling for Tunnel Road Fire Fighting

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Fire resistance testing of technical cabinets in accordance with EN

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

Innovative Solutions for Active Fire Protection in Road/Rail Tunnels and Underground Facilities

Fire protection solutions for ships and offshore facilities

2012 International Symposium on Safety Science and Technology Investigation on compressed air foams fire-extinguishing model for oil pan fire

Heat pump supplemental heating system for motor vehicles

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

ASSEMBLY 37TH SESSION

Research on fire protection methods and a case study "Futurum"

RETOS Y TENDENCIAS DESARROLLO DE INFRAESTRUCTURA EN AUSTRIA. Leonardo Rosas Sánchez Bogotá Agosto 9 de 2018

RESEARCH TECHNICAL REPORT. SMART Sprinkler Protection for Highly Challenging Fires - Phase 2: Full-Scale Fire Tests in Rack Storage

High-pressure water mist systems and fire testing. Max Lakkonen IFAB Institute for Applied Fire Safety Research

This document is a preview generated by EVS

Developing a Fire Test Strategy for Storage Protection Under Sloped Ceilings

Wet Chemical Fire Extinguishing System for Extreme Low-Temperature Vehicle Applications

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

Power Generation. ASD 535 Application Report

Can we use knowledge and experience from other sectors to prove Water mist s suitability for land applications? UK Water Mist Seminar 8th March 2016

CERTIFICATE OF FIRE APPROVAL

Comment on Hawker Stall Fires

CFD Simulation of the Water Mist Effect on Fire

Fire Protection Scover

The Train Now Arriving At... Harmonised Fire Safety For European Rolling Stock


DRY CHEMICAL POWDER SYSTEM REQUIREMENTS TO COMPLY WITH THE LATEST IMO IGC CODE AND EUROPEAN COUNCIL CLARIFICATIONS

Requirements for ships carrying hydrogen and compressed natural gas vehicles

ClassNK Technical Information No. TEC-0453 Attachment (1) to ClassNK Technical Information No. TEC-0453 Guidance on SOLAS Chapter II-2 as amended in 2

Transcription:

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles Peter Stahl Wagner Schweiz AG, Wallisellen, Switzerland Abstract Fire detection system and firefighting solutions are getting a common safety measure on newly designed and built trains in Europe and other parts of the world. While international and national regulations as laws or the European TSI often prescribe the minimum requirements on vehicle safety, these regulations do not give any guideline to evaluate the performance of such systems. Thus these regulations describe the necessity of installing a system, but do not introduce a test scheme to measure the system performance. Installation guidelines as known from the building practice do not exist for this field of application. To compensate for this lack of guidelines and standards the European manufacturers of fire safety system for rolling stock together with the attestation and certification bodies have developed a series of guidelines (so-called ARGE guidelines) to determine the system performance and give success criteria for fire detection, aerosol and gas fire extinguishing and water mist firefighting on railway vehicles. The paper will present the three ARGE Guidelines [1-3] which were developed since 2009 and focus on the experience gained in using these guidelines. The testing methods will be described and the choice of these methods justified. Keywords: Fire detection, fire suppression, railway vehicles, ARGE guidelines Introduction The European Technical Specifications for Interoperability for Railway Traffic (TSI) [1], and the European standard EN 45545-6: 2013 include requirements for the installation of fire detection and firefighting systems. These requirements are depending on the type of vehicle and its class of operation.

However, an assessment of these fire safety systems is not defined in these standards. The ARGE Guidelines Parts 1 to 3 [2, 3, 4] define a practical assessment method based on the objective of personal safety. The same targets have the Italian standard UNI 11565:2015 and the future European standard on Fire Containment and Control Systems for railway vehicles in preparation by CEN/TC 256. ARGE Requirements on fire detection The ARGE Guideline Part 1 Fire Detection in Rolling Stock [1] gives guideline to the choice of detector type and defines functional testing of installed fire detection systems on railway vehicles with the target to measure detection response on optimize the detector positioning in the vehicle. It addresses both occupied areas as well as technical areas. The defined target values on thresholds are chosen in order to establish personal safety in the railway vehicle. Testing (here type testing) shall always done on a real vehicle. Detection principle The ARGE Guideline generally considers both smoke and heat detection. It defines the following choice: Potentially occupied areas smoke detection Technical areas smoke or heat detection Potentially occupied areas are considered areas in which passengers or train personal can stay, examples are passenger areas, compartments, staff compartments, restrooms, driver s cabins, restaurants etc. Here usually point-type smoke detectors (EN 54-7) or aspiration smoke detectors (EN 54-20) are in use. Technical areas are electric cabinets in the passenger area, technical compartments on the roof or under the vehicle, engine compartments etc. The use of fire detectors tested according to EN 54 is stipulated. Thresholds The following thresholds for the maximum detection times are defined. Potentially occupied areas Technical areas (not combustion engines) Combustion engines 1 minute 2 minutes 1 minute These times are bases on the test assessment described below and include the time of alarm transmission. That means that the time between start of the test and the alarm signal is assessed. Testing equipment and assessment Testing of smoke detectors is done using a smoke generator with thermal lift. Figure 1 shows the potential test set-up.

Fig. 1. Test set-up with methanol pan or gas burner [1]. The thermal lift is generated using chimney of 50 cm height and - Either a methanol pan with: 22 cm x 22 cm surface max. - Or a gas burner with 2.9 W power The gas burner method was added later to the standard as the methanol creates a risk especially in case of moving vehicles. In case a compartment or technical cabinet is tested in which the chimney does not fit, the smoke generator will be placed outside the cabinet and the smoke lead through a tube with a tubular smoke heater for creating thermal lift (see Fig. 2). Fig. 2. Test set-up or small technical areas [1]. The smoke generator has to be calibrated before the test and following types of fluid are recommended by tests: - Regular Fog (Look Solutions) - Base XL (HazeBase)

The quantity of fluid to be used in the test is defined as: Smoke quantity Occupied areas/ combustion engines (Threshold max. 1 minute): Test duration: 60 seconds with totally 10 ml (+/- 1ml) Of which 30 seconds with totally 4 ml +/- 0.5 ml 30 seconds with totally 6 ml +/- 0.5 ml Technical areas (Threshold time max. 2 minutes): Test duration: 120 seconds with totally 15 ml +/- 1 ml The positioning of the test equipment and the realization of the test smoke's thermal lift should be focused at areas which a) are most unfavorable for quick detection of the fire, b) permit hidden ignition, c) can be used for storage of larger items of travel luggage. The tests have to be performed with all possible air circulation situations in service (e.g. ventilation ON, OFF, heating, cooling). Thereby individual tests can be omitted if the related situations are covered by other similar air circulation situations. Tests in technical areas have to be carried out at maximum ventilation and without ventilation. For vehicles with windows that can be opened, this means that tests have to be carried out during a test ride as well. As heat release tests cannot be carried out without damaging a prototype, it is prescribed that heat detectors in technical areas have either to be installed in a distance of maximum 0.5 m to any ignition source or a CFD simulation has to prove the position. For heat detection often linear heat detectors are used. Justification The smoke release rates above where experimentally determined based on the test fires: - Burning travelling bag ignited by an UIC paper cushion (for passenger areas) - Cables with thermal overload (for technical areas) The traveling bag is in alignment with the ignition model No. 5 of Appendix 1 of EN 45545-1:2013. Its size is in line with the Swedish study "Carried Fire Load in Mass Transport Systems" [5] and has been tested experimentally at the Material Research Centre Leipzig (MFPA) [6]. Details regarding these models see [3]. The maximum threshold times were defined in order to allow passenger and personal at any time to escape to a save area. A safe area is defined as follows by the German vfdb [7].

Table 1. Requirements for a safe area [7]. ARGE Requirements on fire fighting The ARGE Guideline - Part 2 "Fire fighting in Rolling Stock" [3] focuses on the assessment of fire-fighting and fire extinguishing systems on railway vehicles by setting minimum requirements. It supports the selection of the extinguishing agent. The guideline requires a detection according to ARGE Part 1 [2], which automatically triggers the firefighting system after detection. For the requirement of the vehicle's continued ability to run in case of fire, the assessment must achieve: - "Areas of relative safety" for affected persons in the passenger areas, at least by a fire fighting system which controls a fire, or - "Areas of absolute safety" in equipment areas, by a fire extinguishing system. Extinguishing agent and equipment Extinguishing systems shall be systems that fully extinguish a fire in technical areas. These can be either gas extinguishing systems, water mist systems or aerosol systems. In passenger and staff areas generally water mist fire-fighting systems are used and recommended. Those systems do not necessarily fully extinguish a fire, but control it at a size in which it does not pose a life danger any more. It I not allowed to release substances of concern for health. The assessment shall be done for gas and aerosol systems at a prototype vehicle or the first vehicle of a series, for water mist systems at mock-ups. For the passenger area a mock-up is defined which is considered conservative and allows the transfer of the result on any real vehicle with open passenger areas. Where applicable, the hardware shall be approved according to EN 12094. Assessment and thresholds for occupied areas The assessment of water mist fire-fighting systems should be done in a mock-up conservatively representing all passenger areas. Tests done in a real first series vehicle will be only valid for this vehicle class. Figure 3 shows the mock-up. It is conservative as the materials for seats and walls are formed of PUR foam blocks (400 mm x 400 mm x 100 mm) and wood, which is conservative compared to real materials on rail vehicles, which are barely ignitable following current regulations and standards as EN 45545-2:2013.

Fig. 3. Test mock-up and test positon as well as fire sources acc. to [3]

The following four tests have to be performed for each testing position - Travel bag test (see [3], [6]) two times - Test with two PUR foam blocks (also called IMO cushion [8]), two times The fire is always ignited using a paper cushion according to UIC 564-2 [9]. The pre-burning for each test is minimum 60 s. After the pre-burning team, the fire-fighting system is released manually. The four tests as above have to carried out using different positions and interior arrangements - Fire load on and under the seats - Seat arrangements (wall mounted, bus-like or seats facing each other For each test a fire positions has to be chosen, which is most unfavorable to the position of the nozzle of the fire-fighting system. The fire-fighting system should be operational for 10 minutes. During the whole test and until 30 minutes after the start of the test outside an area of maximum 2 meters around the fire location, the presence of persons must be possible. The target values of Table 1 shall not be exceeded within this period. This is monitored and measured according to figure 4. Fig. 4. Measuring positions [3] Assessment and thresholds for technical areas In technical areas - differently form the passenger and staff areas - a full extinguishing of a fire is required. Possible extinguishing agents are gas, aerosol or water mist. Before the activation of the fire extinguishing system, the technical equipment in the affected area must be switched off. In areas with electric components, this concerns the complete electrical shutdown. In areas with combustion engines, this means to shut off the fuel supply and the engine. Air flows due to ventilation or train movement have to be taken into account. For gas extinguishing agents only agents are allowed listed in EN 15004. The design concentration of this standard has to be proven by a concentration measurement. For water mist or aerosol extinguishing system a 1:1 extinguishing test is needed.

For combustion engines, there are three tests - A spray fire with 0.0033 l/s fuel (15 s pre-burning) - 1 m 2 diesel fire below engine (fire pan with 1800 kw; 60 s per-burning) - 0.25 m 2 diesel fire below engine (fire pan with 380 kw; 60 s per-burning) For other technical areas, - Cable fire tests acc. To CEN/TS 14972:2008 ignites with 50 ml n-heptane (15 x 15 cm pan). Pre-burning ends when half of cable are on fire. - A pool fire of the size 15 cm x 15 cm with 18 ml n-heptane and 2 ml toluene. In addition the following requirements are to be met Liquified gas extinguishant (e.g. Novec 1230) Non-liquified gas extinguishant (e.g. nitrogen) Water Mist First extinguishing agent at nozzle after Design concentr. achieved after Holding time after reaching design concentration 10 s 20 s 30 s 10 s 120 s 180 s 10 s Min 120 s discharge duration Justification The use of the travel bag as representative fire source was justified above. The use of the IMO cushions (PUR blocks) was introduced to achieve better reproducibility in the testing of water mist fire-fighting systems for occupied areas. Even though the size and the packing an content of the travel bag is standardized (see [3]), fire-fighting results with travel bags have naturally a certain variety, Based on comparative tests (see figure 5) the test based on the PUR blocks has been developed. ARGE Part 3 is on the assessment of the system functionality and the integration on the train information system and not considered in this paper. Experience in ARGE Testing Since the first publication in 2008, the ARGE guidelines have been used in various projects by various manufacturers. Therefore experience in testing and assessment has been gained. Experience in Fire Detection Testing One main result of the experience gained, was that the use of methanol as means of smoke heating can lead to dangerous situation, especially in case of moving vehicles. Therefore - as mentioned above - the gas burner has been introduced as alternative means. Figure 6 shows an

example of the testing of fire detection systems in passenger compartments. Fig. 5. Comparison of travel bag design fire with PUR block fires. Fig. 6. Examples of ARGE fire detection testing in passenger areas [Wagner internal]. For smoke point-type detectors approved according to EN 54-7 this testing method allows a maximum distance of about 5 to 6 m. However this value is influenced and can be decreased due to air flow e.g. by heating or HVAC.

No clear prediction is possible on the effect of HVAC. In some cases even in the same car with the same HVAC system the presence of HVAC can decrease detection ti9mes, while in other position it can increase detection times. See figure 7 for an example. Fig. 7. Influence of HVAC on detection times [Wagner internal] Generally it shows that ASD systems are less influenced by air movement s due to HVAC or other reasons. This is due to the facts that the sampling points can be positioned so that they are monitoring smoke at the smoke extraction points into the HVAC systems (often above the line of windows). Furthermore the active air sampling makes them generally less influenced by air movements. In case of moving vehicles with openable windows during test rides at 80 km/h it was observed that while ASD systems can still locate smoke in the correct fire detection zone, point-type detectors gave first alarm in a wrong zone due to smoke carryover. Experience on small compartments like electrical cabinets, show that the smoke generator test generally can be passed easily (example Fig. 8). The fog heater according to Fig. 2 is normally not needed. Fig. 8. Smoke test in an electrical cabinet Experience in fire fighting Fire-fighting experiments with water mist in passenger areas have confirmed that testing in prototype vehicles is much easier to pass with positive results than testing on the mock-up built according to Fig. 3. This is understandable as in real newly constructed trains seats are

made of non-combustible materials according EN 44545-2, while the mock-up uses PUR blocks to simulate the seats. So the initial fire spread during pre-burning time is much bigger and the fire load much higher. Figure 9 shows picture of fire-fighting testing in a mock-up experiment. Figure 10 shows the example of travel bag fire-fighting test. Fig. 9a Before Test. Fig. 9b. Pre-Burning Time. Fig. 9c. During Fire Fighting. Fig. 9d. After Test. Fig. 10a. Before Test. Fig. 10b. Pre-Burning Time. Fig. 10c. During Fire Fighting. Fig. 10d. After Test [Wagner internal].

The fires are not always fully extinguished after the 10 minutes of water mist fire-fighting. However they are kept small and do not grow again, so that the conditions of Table 1 are met for 30 minutes. For meeting the requirements usually water quantities of less than 0.15 L/min/m 3 are needed with a fine mist. Figure 11 shows the water mist formation. Fig. 11. Water Mist formation [Wagner internal]. UNI 11565 and Future European Standard Parallel to ARGE Italy has developed a national standard for assessing fire detection and fire-fighting systems. The currently valid edition is UNI 11565: 2016. The fire detection requirements are very similar to ARGE. As means of fire source either a smoke generator as in ARGE can be used or PUR blocks of 300 x 300 x 40 mm (smaller than one IMO cushion) can be used. The detection times are as in the ARGE guidelines. Fire-fighting tests shall be done exclusively on mock-ups of the sizes: - 12 m x 2.9 m x 2.5 m for open passenger areas - 2.5 m x 2.5 m x 2.5 m for compartments Test fires differ here from the ARGE guideline Part 2 [3]. Also here are two test fires needed. For the first with IMO cushions the fire source is only one IMO cushion (instead of two as in ARGE). Seats are made by IMO cushions as in ARGE (see figure 12). Fig. 12. IMO cushion fire test for water mist fire-fighting in UNI 11565.

Additionally to ARGE a luggage rack with IMO cushions is introduced. These tests have to be carried out with different seat arrangements and different positions of the fire compared to the water mist nozzles (nozzle close to fire, fire in between two nozzles). The bag test is replaced by a metal tray put under the seat. This metal tray is shown in figure 13 and shall represent luggage. Fig. 13. Metal tray to be positioned under seat acc. To UNI 11565 with (1 = Cotton, 2 = Paper, 3 = Polyamide). Ignition source is ethanol (50 ml for IMO cushion test; 100 ml for luggage test). The pre-burning time is as in ARGE 60 seconds. The success criteria are: The values shall not be exceeded during the whole test. The observation time here is 20 minutes. Different from ARGE no minimum discharge duration is given. Figure 14 shows as an example results for a luggage test. The biggest difficulty is that during pre-burning an initial discharge the 65 C are not exceeded at the measuring point directly at ceiling above the fire source. ARGE only has the measuring point in 1,6 m distance. Fig. 14. Example of luggage fire-fighting test according to UNI 11565.

Comparison of our tests under both standards (ARGE guideline Part 2 and UNI 11565) show that it seems to be more effective for fire-fighting to discharge a given amount water in a shorter time than over a longer period of 10 minutes (as required by ARGE). An intensive knock down in the first 3 to 5 minutes may have a better fire reduction effect than a slower discharge over 10 minutes. Currently CEN/TC 256 is working on a European standard for the assessment of Fire Containment and Control Systems (FCCS) on railway vehicles. Key focus here is the potential replacement of fire doors between railway cars by an FCCS which may be consisting of fire detection and fire-fighting systems. Target is to achieve the same performance as a fire door would give. This may lead to nouveau concepts like fire-fighting not over a whole car, but only at the connection between two cars. However this standard is not evolved far enough to give details. However it will certainly influence the future technologies. References [1] TSI LOC&PAS Technical Specification for Interoperability for Locomotives and Passenger Cars, in force by Commission Regulation (EU) 1302/2014. [2] ARGE Guideline - Part 1, "Fire detection in rolling stock" (2012). [3] ARGE Guideline - Part 2, "Fire fighting in rolling Stock" (2012). [4] ARGE Guideline - Part 3 "System functionality of fire detection and fire-fighting systems in rolling stock" (2012). [5] Carried Fire Loads in Mass Transport Systems - A study of occurrence, allocation and fire behavior of bags and luggage in metro and commuter trains in Stockholm, [Mia Kumm, Mälardalen University] Studies in Sustainable Technology SiST 2010:04. [6] Test logs - travel bag test center BCL / MPA (November 2003). [7] VfdB Guideline: Engineering methods in fire safety by Referat 4 (11/2013). [8] IMO A.800 (19) "Revised Guidelines for approval of sprinkler systems equivalent to that referred to in SOLAS regulation II-2/12" (November 1995). Note: In chapter 6.4 of the standard, the requirements and characteristics for the fire object or reference fire load "IMO cushion" (polyether foam cushion) are defined. [9] UIC 564-2 (3rd Issue with 2nd amendment note July 1994), Regulations concerning fire prevention and fire-fighting measures in passenger-carrying railway vehicles or assimilated vehicles used on international services.