North American Flame Detector Adapters 8832 through 8839 and Series R

Similar documents
FLAME DETECTOR ADAPTERS 8832 through 8839 and Series R Bulletin 8832

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

NMG NOZZLE MIX GAS BURNERS

Eclipse 90 UV Scanner Model A Version 1

Eclipse Self-Check UV Scanner

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

Fireye FLAME SCANNERS

DESCRIPTION, CAPACITIES, SPECIFICATIONS, APPLICATIONS

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

Distributed By: M&M Control Service, INC

1500 SERIES SMALL CAPACITY ULTRA 2 LOW NO X TM BURNER

ECLIPSE INFORMATION GUIDE

MBCE-110/230UV Flame Sensor Module

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

Specifications of V-Line burners

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

FIREYE FLAME SCANNERS

UV - flame detector dual fuel burners for intermittent burner operations

FIREYE C9707A ALL FUEL SCANNER

Each burner shall be equipped with a Micro-Processor Based Burner Management Flame Safeguard and Parallel Positioning Control System.

FIREYE FLAME SCANNERS

C7004B Flame Rod Holder

PBG PACKAGED GAS BURNER

FIREYE M4RT1 FLAME SAFEGUARD CONTROLS DESCRIPTION

INDITHERM. Low temperature gas burners

Indirect gas-fired air heater

FIREYE FLAME SCANNERS

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

Section 1 Overview. Introduction 1-1

ABB. Measure IT Uvisor System Flame scanner for fuel oil and coal flame. UR600 IR Mod flame scanner Product Data Sheet (rev.

DESCRIPTION AND INSTALLATION

NMC Nozzle Mix Gas/Oil Combination Burners

FIREYE FLAME SCANNERS

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

STR-Series Indirect-Fired Air Turnover Units

Figure 10 or Figure 6

SIL3. C7961E,F Dynamic Self-Check Ultraviolet Flame Detector. Capable APPLICATION FEATURES PRODUCT DATA. Contents

Table of Contents. Part Number Index SANDYS INDUSTRIAL GLASS WHEELER A

INDITHERM. Low temperature gas burners

DESCRIPTION AND INSTALLATION

7800 SERIES RM7888A Relay Module

OPERATING AND MAINTENANCE MANUAL

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

Distributed By: M&M Control Service, INC

C7061A,F Dynamic Self-Check Ultraviolet Flame Detector

DESCRIPTION AND INSTALLATION

INSTALLATION INSTRUCTIONS

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

LFL Series Burner Flame Safeguard Control

FIREYE NXF4000 ADVANCED BURNER MANAGEMENT SYSTEM with INTERNAL FLAME SAFEGUARD

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

PRODUCT: SEL-SV-MCQ-O5- K6 VERSION TECHNICAL SHEET 1/5 SAC

INSTALLATION INSTRUCTIONS

Installation Instructions

INFRARED RADIANT HEATER RSCA SERIES CERAMIC HEATERS NATURAL GAS PROPANE GAS DATE: PROJECT: ARCHITECT/ENGINEER: CONTRACTOR: SUBMITTED BY:

UV Flame Supervision System

SOLID STATE Burner Management Controls SERIES D40-41

CABS/BLADES/ SPREADERS/ACCESSORIES

SUBMITTAL SCHEDULE & DATA

SECTION GAS-FIRED RADIANT HEATERS

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

INSTALLATION INSTRUCTIONS

UV - flame detector KLC 10 for oil -, gas- and dual fuel burners for intermittent burner operations

C7915A Infrared Flame Detector

PART 0 A/E INSTRUCTIONS 0.01 DESIGN REQUIREMENTS

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

MBCE-110/230FR Flame Sensor Module

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Flame detector. The QRA4.U is for use with the following types of burner control:

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

SERVICE TECHNICIAN ONLY read and follow completely.

CG Section and Base Assembly Series 1 through 12

Flame detector. The QRA4.U is for use with the following types of burner control:

Fireye Flame Safeguard Controls

7800 SERIES EC7885A/RM7885A Relay Module

ECLIPSE AH-MA BURNERS. Air Make-Up Burners. Designed for trouble-free make-up or process air heating. Ready for the world

FIREYE FLAME SAFEGUARD CONTROLS DESCRIPTION

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

ED510 DISPLAY MODULE. FOR USE WITH FIREYE FLAME-MONITOR AND MicroM BURNER MANAGEMENT CONTROLS DESCRIPTION INSTALLATION APPROVED

LMV51 Control. Specifications. Document No. LV February 7, Product Description. Sample Specification

12a. Replacement parts. GOLD CGs Gas-Fired Water Boiler Boiler Manual. Section assembly Base Jacket Trim Controls...

Power Flame Incorporated

FIREYE E210/211 FLAME-MONITOR

CSD-1 COMMERCIAL BOILER CONTROLS

EUROBOX SERIES TYPES CM... SM... MM...

U n i t H e at e r s

7800 SERIES RM7888A Relay Module

ABB. Measure IT Uvisor System Flame scanner for gas and oil burners. UR450 Mod UV flame scanner Product Data Sheet (Rev. B)

Refer to Bulletin E-1101 for detailed information on the FLAME-MONITOR System.

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

BURNER MANAGEMENT CONTROLS

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

W-FLAME IR/UV FLAME DETECTOR

Model gffoz Process Ozone Sensor (In-Line)

Transcription:

Combustion North American Flame Detector s 8832 through 8839 and Series R s simplify installation of flame detectors on North American burners. They also facilitate access to detectors for servicing. Most adapters include a purge air connection. All adapters and flame detector combinations come with a means of removing the flame detector without twisting or disconnecting wires. Review the flame detector manufacturer's installation and operation literature to insure all limitations and regular maintenance are addressed when using flame detector equipment. Selection: Refer to Table A for a list of flame detectors commonly used with North American burners. Determine the adapter series number based on your specific flame detector model. If your specific model is not listed or you are using another brand of flame detector, refer to the manufacturer s literature to determine the flame detector s connection type and specific thread size. Table B determines the adapter suffix based on the specific burner being used. Examples: When using a Honeywell C7027A on a 6514-4 burner, specify an 8836-D adapter. 8835-R with C7061A U. V. Scanner When using a Honeywell C7007A on a 4422-4 burner, specify an 8832-B adapter. See Page 4 for Series R s for smaller size Flame Detectors. Table A. Numbers for Various Honeywell and Fireye Devices Manufacturer Mfgr's P/N Device Connection Device No. Honeywell C7007A ½ " male NPT Flame rod holder 8832 Honeywell C7004B 1¼ " female NPT Flame rod holder 8833 Honeywell C7061A&F ¾" female NPT Ultraviolet 8835 Honeywell C7027A ½ " female NPSM Ultraviolet 8836 Honeywell C7035A 1" 1 /female NPSM Ultraviolet 8837 Fireye 65UV5 1" female NPT Ultraviolet 8837 Fireye 95UVS2 1" female NPT Ultraviolet 8837 NOTE: Some Honeywell flame detectors that do not fit or are not recommended with North American burners are: C7004B1002, 1010, and 1028, C7004B5, C7007A2, C7008A, C7009. s do not include detectors--order separately. See Sheet 8832-1 Device is also compatable with 8833-R adapter

Table B. ADAPTER SUFFIX LETTERS for North American Burners Page 2 4343... 4422-2 thru -6...B 4422-7-A thru -8-A...A 4423, 4424...B 4425-2 thru -6...B 4425-7-A thru -8-A...A 4431-8-A...B 4441, 4442, 4442A...A 4514... D 4545-6 thru -8... D 4545-9 FR only... L 4558/4558- -V...B 4630 w/4630-p...j 4630 w/4021-15 or -16...M 4659...B 4682...H 4723... 8838-E 4724... 8838-E 4725... 8838-E 4726...C 4762...B 4777...H 4795... D 4796...B 4808...B 4818......G 4819......G 4825....F 4828...B 4831...B 4832, 4833, 4836...B 4841...B 5422-2 thru -6...B 5514... D 5795... D 5796...B 5819... G 6421...B 6422-2 thru -6...B 6422-7-A thru -8-A...A 6423...B 6425-2 thru -6...B 6425-7-A thru -8-A...A 6427-8-A...B 6435...B 6514... D 6520... D 6521... D 6526...B 6527-7...A 6562 (Obsolete)...H 6570 Pilot...B 6570 Main Flame... D 6575...B 5422-7-A thru -8-A...A s do not include detectors--order separately. Use C7035A UV only with 8837-F or -G because of ambient temperature considerations. includes Honeywell Heat Block. Or Series R. Also, R can be used in place of any A or B. When flame supervision is mounted, Sensitrol TM Oil Valve cannot be close-coupled because of interference with handle. See Sheet 4343-3 for TwinBed II flame detector assemblies. Requires modified version of adapter shown in Fig 1, page 3. Use adapter 4-6153-1 6736...B 6758...B 6795... D 6819... G 6820... G 6825... F 6832...B 6833...B 6836...B 6841...B 6843...B 6855...B RADIANT TUBE BURNERS Flame supervision can be used with 4723 and 4725 Radiant Tube Burners. The 8838-E-UV -Detector assembly includes a modified C7035A-1080 Detector and 8790-0 Observation Port. The 8838-E-UV assembly is threaded into the back of a standard 4723 or 4725 Burner in place of its observation port. An integral observation port is mounted in the upper leg of the "Y", while the lower leg holds the C7035A Detector. The "Y" fitting can be removed without disturbing the quartz sealing lens in the front of the adapter. The quartz sealing lens must reamin in-place to prevent fuel leakage. Since no burner modification is involved, an 8838-E-UV - Detector can be added to many existing burners. A radiant tube burner flame supervision concept must take into account the fact the UV detector will not pick up the pilot flame. Sequence begins trial for ignition simultaneously with both pilot and main flame. During operation, direct spark ignition or gas pilot must be interrupted after normal ignition interval. Pilot air can be left on under all normal operating conditions. When replacing a UV detector in the field, modify the C7035A-1080 by removing the tubular shield from the UV tube to allow adequate signal strength. Position the detector tube for maximum grid exposure with upright plates at sides. The 8838-E is rated for up to 10 psig backpressure. 8838-E-UV ADAPTER 8790-0 Observation Port To order, specify: 8838-E-UV Flame -Detector including C7035A-1080 UV Detector, or 8838-E Flame Detector only. Remove tubular shield and install gasket supplied with C7035A when installing adapter and flame detector. Flame Detector Honeywell C7035A-1080 (R130-5845) 2 req'd 4-7417-1 (one each side) 4-7416-1 Quartz Lens

Flame Detector Dimensions in inches For a For a Cooling burner detector Overall Radius Air designation having having length max. connection 8832-A ¾" NPT ½ " male 67 8" 21 8" ¼ " NPT 8832-B ¾" NPT pipe thread 5" 21 8" 8832-C ½ " NPT 4¾" 2" 1 / 8 8832-D 1" NPT 5½ " 21 8" 8832-H 3 8-16 ANT 37 8" See Fig. 1 None 8832-J ¼ -20 UNC See Fig. 3 See Fig. 3 ¼ " NPT 8832-M ¼ -20 UNC See Fig. 2 See Fig. 2 8832-P 1" NPT 613 16" 25 8" 8833-A ¾" NPT 1¼ " female 9" 23 8" 8833-B ¾" NPT pipe thread 73 8" 23 8" 8833-D 1" NPT 73 8" 25 8" 8833-H 3 8-16 ANT 51 8" See Fig. 1 None 8833-J ¼ -20 UNC 17 8" See Fig. 3 ¼ " NPT 8833-L 1" NPT 11" 2¼ " 8833-M ¼ -20 UNC 17 8" See Fig. 2 8835-A ¾" NPT ¾" female 715 16" 2½" 8835-B ¾" NPT pipe thread 65 16" 2½ " 8835-C ½ " NPT 6¼ " 2½ " 8835-D 1" NPT 7" 2½ " 8835-H 3 8-16 ANT 71 8" See Fig. 1 8835-J ¼ -20 UNC 5½ " See Fig. 3 8835-L 1" NPT 103 8" 2¼ " 8835-M ¼ -20 UNC 5" See Fig. 2 8836-A ¾" NPT ½ " female 61 16" 2¼ " 8836-B ¾" NPT pipe thread 4 9 /16" 2¼ " 8836-C ½ " NPT 37 8" 2" 1 / 2 8836-D 1" NPT 413 16" 2¼ " 8836-F ¾" NPT 511 16" 2¼ " 8836-H 3 8-16 ANT 61 8" See Fig. 1 8836-J ¼ -20 UNC 51 16" See Fig. 3 8836-M ¼ -20 UNC 4¾" See Fig. 2 8837-A ¾" NPT 1" female 515 16" 25 8" 8837-B ¾" NPT pipe thread 415 16" 25 8" 8837-D 1" NPT 47 8" 25 8" 8837-F ¾" NPT 8¾" 25 8" 8837-G 1" NPT 8¾" 25 8" Page 3 Fig. 1. "H" adapter mounted on 4682 burner Fig. 2. "M" adapter for 4021-15 or 4021-16 Pilot Tip on 4630 Main Burner Sections. Fig. 3. "J" adapter mounted on 4630-P pilot section To order, specify: number with appropriate letter suffix. Example: 8836-B A throttling valve in the cooling air line is suggested for limiting air flow to minimum amount required. "Radius max." applies to adapters not dimensioned above: It is the radius of a cylinder in space the adapter would occupy while being screwed into mounting. 8832 and 8833 adapters for flame rods only. See Sheet 8832-1, page2 Includes a non-conducting adapter (Honeywell Heat Block). 1 8 pipe plug 3 8 8838-E-UV -Detector assembly including C7035A UV Detector and 8790-0 Observation Port 21 8 hex 1¼ 7 8 8790-0 Obs. Port 9 64 513 16 35 8 ¾ NPT 3 40 Weight: 25 8 lb Allow 2½ for tube removal 6½

"R" ADAPTERS for FLAME DETECTORS Flame detector adapters are available for specific flame detectors. s have a sealing window and a ¼ tube (1/8 NPT) connector for cooling or purging air. The most common configuration is to use purge air, where approximately 2 to 3 cfm of air is used to keep the fire side of the quartz sealing lens clean as well as to provide cooling to the UV scanner and adapter assembly. In the purge air configuration, the flame detector is isolated from the purging air and burner environment/combustion chamber by the quartz sealing lens. When using the purging configuration on a burner developing backpressure and/or firing into a positive combustion chamber, use sufficient air pressure to assure positive purge air flow through the adapter. Purge air flow can influence the lighting characteristics of certain burners and/or limit their performance range at reduced firing rate. Care must be taken to adjust the purge air flow for adequate purge and cooling without introducing an undesirable limitation in burner ignition reliability or performance. Page 4 The alternate configuration is to use cooling air, where approximately 1 cfm of air (at 8 osig pressure) is used to cool the adapter as it passes through the space between the quartz sealing lens and the flame detector. This configuration is only used when no purge air flow can be tolerated by the burner. R s are shipped with a setscrew plugging the hole that vents cooling air. Leave the setscrew in place for purging air. Remove the setscrew if cooling air is employed and mount the detector on the tube side of the adapter, opposite of the sealing window. s have a ¾ NPT thread to fit the ¾ NPT flame detector mounting provision of most North American burners. The basic 8835-R unit is common to all R adapters. It has a ¾ NPT on both ends. Other adapters are made from the 8835-R by adding the appropriate fitting to one end. The 8835-R adapter is also available with 1 NPT connection as 8833-R. All "R" adapters are rated for up to 10 psig backpressure. ADAPTERS and DETECTORS Detector Connection Size Burner Connection Size 8831-R 3/8" MNPT 3/4" MNPT 8833-R 1" MNPT 1" MNPT 8834-R 3/4" FNPT 3/4" MNPT 8835-R 3/4" MNPT 3/4" MNPT 8836-R 1/2" MNPSM 3/4" MNPT 8837-R 1" MNPSM 3/4" MNPT 8839-R 1" MNPT 3/4" MNPT All Series R adapters have the following parts in common: Cooling Air Connector R916-2211 4-7628-1 Gasket (2 req'd) 4-7629-1 Body 4-9770-2 ¾" Mtg. 4-7932-1 #8-32 R776-1431-N 4-8035-2 8835-R 3½ " long Shown with PC11 UV Scanner 8837-R 6¼ " long Shown with C7035A-1080 UV Scanner

ADAPTERS and DETECTORS continued Page 5 4-8035-3 8839-R Shown with 45UV5 UV Scanner 4-7933-2 8836-R Shown with C7027A UV Scanner 4-8316-2 R590-1250-S Coupling 8831-R 8834-R Shown with UV-2 UV Scanner 5" long Shown with 8790-0 Observation Port DIMENSIONS SHOWN ARE SUBJECT TO CHANGE. PLEASE OBTAIN CERTIFIED PRINTS FROM FIVES NORTH AMERICAN COMBUSTION, INC. IF SPACE LIMITATIONS OR OTHER CONSIDERATIONS MAKE EXACT DIMENSION(S) CRITICAL. WARNING: Situations dangerous to personnel and property may exist with the operation and maintenance of any combustion equipment. The presence of fuels, oxidants, hot and cold combustion products, hot surfaces, electrical power in control and ignition circuits, etc., are inherent with any combustion application. Parts of this product may exceed 160F in operation and present a contact hazard. Fives North American Combustion, Inc. urges compliance with National Safety Standards and Insurance Underwriters' recommendations, and care in operation. CONTACT US: Fives North American Combustion, Inc. 4455 East 71st Street - Cleveland, OH 44105 - USA Tel: +1 216 271 6000 - Fax: +1 216 373 4237 Email: fna.sales@fivesgroup.com www.fivesgroup.com Copyright 5-15 - Fives - All rights reserved. Bul 8832