Zip Chilltap Extra. Affix Model Number Label Here UK. Installation and Operating Instructions

Similar documents
Zenith Chill Tap. Affix Model Number Label Here 89520NZ. Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Zip Domestic Chill Tap

Affix Model Number Label Here

Zip Chilltap Extra. Affix Model Number Label Here Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Zip Domestic ChillTap

Zip Chillmaster Floor Mounted Chiller

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Zenith ChillTap Sparkling

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Zip HydroTap Miniboil

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

ZIP VARIPOINT II Direct unvented water heaters.

Installation and Operating Instructions. ZIP UK Domestic - DOMBC2 - Filtered boiling and chilled drinking water for kitchens.

ZIP HYDROCHILL High capacity chiller systems

Zip Chilled Water Systems

Model pictured: ST6001

Miniboil Boiling Only

Installation instructions. Zip HydroTap. Affix model number label here UK

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

ZIP Aquapoint III. Direct unvented water heaters Models: AP3/05, AP3/05/OB, AP3/10, AP3/10/OB, AP3/15, AP3/15/OB.

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Installation & Operating Instructions

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Installation and Operating Instructions. Commercial HydroTap. Filtered boiling and chilled drinking water for Commercial kitchens and tea rooms.

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

DRINKING WATERCOOLER MANUAL. Website:

Installation guide Sahara & Sahara Plus

Zip filtered water systems. Chilled or unchilled filtered water always on tap. Sparkling, too!

Zip HydroTap. Installation instructions. Filtered boiling and chilled drinking water for commercial kitchens and tea rooms.

Installation instructions. Zip HydroTap. Filtered boiling and chilled drinking water for commercial kitchens and tea rooms.

Zen Boiling Tap Range

Model pictured: ST7001SLIM/ST7001SLIMA

Pear Kitchen Sink Tap

SCHWAN INSTALLATION GUIDE

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Installation & Operating Instructions

Zenith HydroTap. Filtered Chilled drinking water for residential kitchens and tea rooms. Affix Model Number Label Here NZ

OWNE R S MA N UA L. Made in USA. September 2015

INSTALLATION MANUAL CT-200

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

Installation Instructions. Filtered Boiling and Boiling Ambient drinking water for commercial kitchens and tea rooms.

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

aquamanta the experts in aquatic technology

Parasitic Cysts - Cryptosporidium and Giardia, Chemicals, Heavy Metals, Dissolved Salts, Offensive Tastes and Odours, Sediment, Dirt,

Installation Instructions Zip HydroTap G4 CS Residential Affix Model Number Label Here

HydroTap Taps Installation

Target Monobloc Kitchen Mixer Chrome

INSTALLATION MANUAL Wolfen Hob Mounted Sensor Tap with Internal Solenoid. Installation Details Warranty

CHILLER DADDY MODEL: CHL-501 Intended Use For: Residential & Office Water Chiller

Operating and installation instructions

Install Guide Billi Quadra & Quadra Plus (Gooseneck)

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Model pictured: ST90001W/ST9001WA

Model pictured: ST3701

RSA2CL6SS model pictured

STEAM WALLPAPER STRIPPER MODEL HTW5

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

Mobile Air Conditioner Instruction Manual Model TC-N9KM

Steam Mop User Manual

YEAR 2WARRANTY. Windsor Kettle MODEL RHK3 INSTRUCTIONS & WARRANTY RHK3_IB3_281011

Zenith HydroTap. CS Residential. Filtered Boiling, Chilled and Sparkling drinking water for Residential kitchens and tea rooms.

Double Door - Dual Zone Wine Cooler

Sip Vacuum Cleaner 1400/35 Wet & Dry

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

MiniSkim. Inspiring Excellence in Fish Keeping! Instruction version: 17/08/2012.

Autofill counter top water boiler

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Zip HydroTap G4 Celsius

The new Zip HydroTap G4 for a healthier lifestyle

Blueberry Kitchen Sink Tap

Installation & Operating Guide

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

So instant. Boiling and chilled filtered water instantly with Zip HydroTap

Cinnamon Kitchen Sink Tap

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

RHK52_IB_FA_ Part No. T HERITAGE VOGUE KETTLE 2 YEAR WARRANTY RHK52 SERIES

Affix Model Number Label Here 89944

Monza Easyfit Kitchen Sink Mixer

ART cm Island Curved Glass

YEAR 2WARRANTY. Steamglide Iron RHC909 INSTRUCTIONS & WARRANTY RHC909_IB_100112

RHK112_IB_FA_ Part No. T INSPIRE KETTLE 2 YEAR WARRANTY RHK112 SERIES

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

INSTALLATION INSTRUCTIONS USER GUIDE

YORK KETTLE INSTRUCTIONS & WARRANTY 2 YEAR WARRANTY 20431AU 20431AU_IB_FA_190314

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

Installation & Operating Guide

identity installation & maintenance instructions customer/technical services guarantee

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

2-Stage Under Counter Filtration System Model: WP-2 LCV

Transcription:

Installation and Operating Instructions Zip Chilltap Extra Filtered Chilled and Ambient drinking water for the home Affix Model Number Label Here 800043UK Chill Tap - Installation & Operating Instructions - 800043UK - August 2011 v1.03 Page 1 of 8

# Read Section These Heading Warnings First Please read all installation requirements, installation procedures and precautions before installing any Zip Chilltap. Never attempt to install any Zip Chilltap without reading all of the applicable instructions. All electrical connections must comply with UK Electrical Regulations. This appliance is not designed for use by young children or infirm people without supervision. Young children should be prevented from having access to ensure they are not able to use or play with the chiller. This appliance must be earthed. If the power supply cable is damaged it must be replaced by a Zip Service Provider or a qualified electrician. The Power cable and power outlet must be in a safe and accessible position after installation. Do not remove the cover of the appliance under any circumstances without first isolating the appliance from the power supply. This unit is designed for indoor use and must not be installed outdoors or exposed to the elements of nature. This unit must not be positioned in an area that may be cleaned by a water jet. This unit must not be cleaned by a water jet. Precautions The plumbing installation must be done in accordance with UK Water Regulations and these Installation Instructions. As the installer, it is your responsibility to supply (if necessary) and install all valves as required by current regulations and relevant standards. Installation requirements Power supply 220-240V AC 50Hz for connection via a 13A plug or fused spur. Operating temperatures 5º C - 35º C. Water pressure 70 kpa - 700 kpa (0.7 bar to 7 bar) NOTE: For best results we recommend a minimum static pressure of 200 kpa (2 bar) End of life disposal The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste. Within each of the European Union member countries, provisions have been made for the collection and recycling of unwanted electrical and electronic equipment. In order to help preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer service for advice on 0845 602 4533. Page 2 of 8 Chill Tap - Installation & Operating Instructions - 800043UK - August 2011 v1.03

Domestic Models Covered by these instructions These installation instructions are for the Zip UK Domestic DOMCT1 Chilled Water Capacity: 60 glasses per hour Total Rating: 245W Chilled Chamber: 1.8L Chilled Water Temperature: 7º C - 12º C Note: the Glass measurement = 200mls. When correctly installed, operated and maintained in accordance with these instructions, the Zip Chilltap is intended to deliver filtered chilled water for domestic consumption. Model Height mm (inch) Depth mm (inch) Width mm (inch) Weight empty kg s lbs Weight full kg s lbs DOMCT1 377 (14.8) 253 (10.0) 353 (13.9) 17.8 19.8 # Installation Instructions Installing the Chiller Sit the chiller unit into the cupboard as close to the proposed outlet tap position as is possible, to minimise the length of tubing exposed between the chiller unit and the tap. Allow at least 50 mm around the chiller unit to permit free airflow. Both the top and the front of the chiller must remain accessible for servicing purposes. Installing the Tap Position and install the tap at the back of the sink or on the Font, where there is a minimum 52 mm wide flat area within the draining area of the sink. NOTE: The diameter of the base of the tap is 50mm. Make sure the selected position allows the tap spout to overhang the sink bowl. Use a 35 mm sheet metal punch to create a neat hole without burrs. Remove the large nut with the brass and rubber washers from the base of the tap, leaving the rubber-sealing ring (o-ring) in place. Fit the tap and seal to the sink, oriented so both the operating levers are easily accessible. Slide first, the rubber washer and then the brass washer, followed by the nut, over the plastic tubes from under the sink, and tighten the nut to secure the tap firmly into place. Chill Tap - Installation & Operating Instructions - 800043UK - August 2011 v1.03 Page 3 of 8

# Installation Instructions continued Connecting: NOTE: You must separately supply and install an isolating valve in the supply line before the connection to the product. Minimum supply pressure must be 70kPa (0.7 bar). For best results we recommend a minimum static pressure of 200 kpa (2 bar). If the pressure exceeds 700 kpa (7 bar), you must also supply and install a 350 kpa (3.5 bar) pressure-limiting valve. Ambient Connection (with chiller inlet branch line): With 1/4 white tubing, Connect the JG Nut + Straight Connector Assembly to the inlet of the filter. From the outlet of the filter, connect the 1/4 white tubing from the tap, via the Tee piece supplied. The branch line from this Tee piece must connect to the JG fitting marked INLET on the top right rear of the chiller. Cut excess off to ensure a neat job. Make sure all connections to John Guest fittings are pushed in past the O ring to full depth, at least 15-16mm. Chiller connection: Similarly, use the Blue tube, to connect to the JG fitting marked OUTLET on the top left rear of the chiller unit. Insulate the 1/4 BLUE tube with the loose length of the pipe insulation, cut both pieces to correct length. Locate the 1/4 Clear (vent) tube from the tap and connect this to the John Guest connector. Ensure JG Plug is also fitted to connector. Make sure all connections to John Guest fittings are pushed in past the O ring to full depth, at least 15-16mm. The Tap connection is now complete. Take care, when bending rigid plastic tubing, to prevent it from kinking or crushing around a bend. As it is plastic tubing containing water under mains pressure, be careful not to nick, scratch or damage it during installation. Cut the tube squarely with a sharp knife or tube cutter. Shake out and remove any swarf and debris. Ensure there is adequate ventilation available through the cupboard. If there is inadequate ventilation, and the cupboard temperature rises to above 40 C, the chiller may become damaged and malfunction which will void the product warranty. There must be a minimum 168cm2 of cupboard cross-flow ventilation. Suitable holes or vents will need to be cut into the cupboard and door. For safe operation, thoroughly flush the water through after non-use periods longer than 12 hours. John Guest connections Page 4 of 8 Chill Tap - Installation & Operating Instructions - 800043UK - August 2011 v1.03

# Installation Section Heading Instructions continued Filter cartridges should be replaced at least every 6-12 months, or sooner if you notice: A. A persistent reduction in water pressure from the product, or; B. An unpleasant taste or odour in the water. Not changing the cartridges when required may cause the water to become biologically unsafe. Commissioning Clip the tubing in the cupboard. After the appliance is installed and connected, turn ON the water supply. Check all connections for leaks. Repair any leaks found. The filter, chiller and tubing will be full of air until purged. Rotate the operating lever on the appliance outlet tap for a minimum of five minutes until all of the air has been purged from the system. Connect the unit to the electrical supply. Do NOT turn ON until after the unit is purged. Wipe clean and dry the area. Dispose of packaging wisely. JG Connector Blue White Outlet Inlet Incoming water supply JG Nut+Straight Connector Assembly Filter Blue Under Bench Chiller Chill Tap - Installation & Operating Instructions - 800043UK - August 2011 v1.03 Page 5 of 8

# Operating Procedures ROTATE Operation: The lever on the right is used for Chilled filtered water and the other, on the left, is used for Ambient filtered water. Chilled water is obtained by rotating the lever on the right, to a horizontal position. The water is chilled by a refrigeration unit fitted within the cabinet, under the sink. With the tap, you can obtain chilled water within the rated capacity, for as long as you leave the lever in the open (horizontal) position. When finished, return the lever to the OFF (upright) position. Ambient water is obtained in the same way as the chilled water, by rotating the lever on the left hand side of the tap. Cleaning Never use strong, corrosive or abrasive cleaning materials on the Zip Chilltap. Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water. The louvres on the sides of the chiller unit need to be kept free of dust and lint to permit free flow of air through the vents. They should be checked regularly, at least monthly, and dusted or vacuumed. Filter Replacement The Zip Chilltap Under Counter Chiller has a separate filtration system connected to the incoming water supply line, and which may be located within the same cupboard as the chiller unit. For safe operation, the filter cartridge should be replaced every 6-12 months, or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water. WARNING Not changing filtration cartridges when required, may cause the water to become biologically unsafe. Make an entry in your diary to check the water quality of the Chilltap at least six months after installation and after every subsequent filter change. Use only genuine Zip replacement filter catridge ZT002. Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip. Replacement instructions come with the filter cartridges. Before attempting to disconnect or remove the filter cartridge from the housing, isolate (turn off) the water supply prior to the filter system, and then relieve the system pressure by operating the chilled water outlet tap until the water ceases to flow. Service There are no user serviceable parts but there are dangerous voltages present within the unit. All service work must only be carried out by a suitably qualified and experienced service person. Before calling for service, check that both the water and electricity supplies are turned ON and OK. For technical assistance and service support contact Zip on 0800 077 8302. Page 6 of 8 Chill Tap - Installation & Operating Instructions - 800043UK - August 2011 v1.03

# Installation Diagrams DOMCT1 model installation 113 Tap hole ø35mm Min 15 Sink Air gap 113 Buffer pad 4mm 295 30 213 Max 80 213.60 108 218.50 Mains cold water isolation valve Min 200 265 220 Min 65 UK 240V GPO 377 Min 50 353 Min 50 79 Min 50 253 Chill Tap - Installation & Operating Instructions - 800043UK - August 2011 v1.03 Page 7 of 8

Warranty Information Certain warranties may be implied by law into your contract with Zip. The warranty provided below is additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law. Zip Heaters (UK) Ltd warrants that, should any part fail within 12 calendar months of installation, that part will be repaired or replaced free of charge by Zip or its Distributor or Service Provider, except as set out below, provided the appliance is installed and used strictly in accordance with the instructions supplied, and that failure is not due to accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification or repair by any party not expressly nominated by Zip. No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zip Service Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor. This warranty does not cover damage resulting from non-operation of the appliance, the use of non authorised parts or consequential damage to any other goods, furnishings or property. No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption. Zip does not exclude, restrict or modify any liability that cannot be excluded, restricted or modified or which cannot, except to a limited extent, be excluded, restricted or modified as between the owner or user and Zip under the laws applicable. Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip s option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance. Registering Your Purchase Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary to service the appliance under terms of the Zip warranty. To register your installation go to www.zipheaters.co.uk and look under the heading Warranty. As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods. Zip Heaters (UK) Ltd. 14 Bertie Ward Way Dereham Norfolk NR19 1TE Customer Service/ Sales Tel: 0845 602 4533 Service/ Technical Support Tel: 0800 077 8302 E-mail: customerservice@zipheaters.co.uk Website: www.zipheaters.co.uk Chill Tap - Installation & Operating Instructions - 800043UK - August 2011 v1.03 Page 8 of 8