Affix Model Number Label Here

Similar documents
Zip Chilltap Extra. Affix Model Number Label Here UK. Installation and Operating Instructions

Zip Domestic Chill Tap

Zenith Chill Tap. Affix Model Number Label Here 89520NZ. Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Zip Chilltap Extra. Affix Model Number Label Here Installation and Operating Instructions. Filtered Ambient and Chilled drinking water

Zip Chillmaster Floor Mounted Chiller

Zip Domestic ChillTap

Installation and Operating Instructions. Budget priced instant boiling water heater for beverages.

Electronic Instantaneous Water Heaters Models: ES3, ES4 & ES6

Zip Econoboil. Installation and Operating Instructions. Budget priced instant boiling water for canteens and kitchens.

ZIP InLine. Models: ES3, ES4 & ES6. Electronic Instantaneous Water Heaters. ES3, ES4 & ES6 Instructions. V1.09 Page 1 November / 2015

Zip Hydroboil. Installation and Operating Instructions. Filtered instant boiling water

Zip InLine. Models CEX-O & CEX-U Issued August Installation, Maintenance and User Instructions

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

Zenith ChillTap Sparkling

ZIP Varipoint III. Installation, Maintenance and User Instructions. Models VP303, VP503 VP803, VP953 direct unvented water heaters. Issued August 2008

Zip Hydroboil. Instant boiling water. Installation and Operating Instructions

ZIP VARIPOINT II Direct unvented water heaters.

Electronically Controlled Instantaneous Water Heaters Models: CEX-O & CEX-U

Zip Chilled Water Systems

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Zip HydroTap Miniboil

ZIP Aquapoint III. Direct unvented water heaters Models: AP3/05, AP3/05/OB, AP3/10, AP3/10/OB, AP3/15, AP3/15/OB.

Electronically controlled instantaneous water heater. MCX: 27300, and models. Installation instructions

Installation instructions. Zip HydroTap. Affix model number label here UK

Installation Instructions. Filtered Chilled drinking water for commercial kitchens and tea rooms.

ZIP HYDROCHILL High capacity chiller systems

Installation & Operating Instructions

Miniboil Boiling Only

Installation instructions. Zip HydroTap. Filtered boiling and chilled drinking water for commercial kitchens and tea rooms.

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

Electronically controlled instantaneous water heater. MCX: 27300, and models. Instructions for the user

DRINKING WATERCOOLER MANUAL. Website:

Model pictured: ST6001

Zip Tudor. Affix Model Number Label Here Installation Section & Operating Heading Instructions. Single point open outlet (vented) water heaters

Double Door - Dual Zone Wine Cooler

Installation and Operating Instructions. ZIP UK Domestic - DOMBC2 - Filtered boiling and chilled drinking water for kitchens.

INSTALLATION MANUAL LITTLE BUTLER HOT WATER AND DRINKING WATER FILTRATION FAUCETS LB13250 LB13150 DW13050

Pear Kitchen Sink Tap

Zip HydroTap. Installation instructions. Filtered boiling and chilled drinking water for commercial kitchens and tea rooms.

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Autofill Wall Mount Boilers

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Unvented Electric Water Heater 10/15 litre Undersink

The Professional s Choice

Installation & Operating Instructions

Zen Boiling Tap Range

STEAM WALLPAPER STRIPPER MODEL HTW5

airooncentre.co.uk irconcentre.co.uk Xpelair Low Energy Wall/Window Fan Range GX6 EC2 GXC6 EC2 Quick Order Hotline or

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Electronically controlled instantaneous water heater. CEX 9-U: C models. Installation instructions

The Professional s Choice

Blueberry Kitchen Sink Tap

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Cinnamon Kitchen Sink Tap

Electronically controlled instantaneous water heater. DEX: C models. Instructions for the user

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

Monza Easyfit Kitchen Sink Mixer

INSTALLATION MANUAL CT-200

Electronically controlled instantaneous water heater CEX 9. CEX9: C models. Instructions for the user

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

CUBE ICEMAKER MODELS SCU25, SCU35, SCU45, SCU75, SCU95, SCU120 INSTALLATION AND SERVICE MANUAL VERSION 2

Operating and installation instructions

Target Monobloc Kitchen Mixer Chrome

identity installation & maintenance instructions customer/technical services guarantee

Installation Instructions Zip HydroTap G4 CS Residential Affix Model Number Label Here

CHILLER DADDY MODEL: CHL-501 Intended Use For: Residential & Office Water Chiller

REMOTE COOLER AIR COOLED & WATER COOLED

BRITA. Water Filter & Chiller II. Chilled water filter. Instruction Booklet WF6100

Installation and Operating Instructions. Commercial HydroTap. Filtered boiling and chilled drinking water for Commercial kitchens and tea rooms.

INSTALLATION GUIDE Little Butler Hot Water Dispensing Faucets and Drinking Water Dispensing Faucets

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

HINTS AND TIPS Cleaning and maintenance HELPLINE

Installation instructions Zip HydroTap. Filtered boiling, chilled and sparkling drinking water for residential kitchens.

INSTALLATION INSTRUCTIONS OWNERS GUIDE & WARRANTY STATEMENT

MHG201 Gas Hob Manual for Installation, Use and Maintenance

SCHWAN INSTALLATION GUIDE

HVG620 & HVG720 Gas Hob Manual for Installation, Use and Maintenance

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

The Classeq pass Through range

OWNER S MANUAL. Convair Tower Heater CTH09. (English) (CTH09)

INSTALLATION GUIDE NZ AU

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

DC Heat Recovery Unit MVHR Wholehouse heat recovery unit

Brita. Water Filter & Chiller. Instruction Booklet WF6000. Please read these instructions carefully and retain for future reference.

Zenith HydroTap. CS Residential. Filtered Boiling, Chilled and Sparkling drinking water for Residential kitchens and tea rooms.

Model pictured: ST7001SLIM/ST7001SLIMA

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

TH100 Three in One Instant Hot Water Tap

aquamanta the experts in aquatic technology

Zenith HydroTap. Filtered Chilled drinking water for residential kitchens and tea rooms. Affix Model Number Label Here NZ

Instruction Manual JLHDA cm Cooker hood

Tabletop Cooler. Installation and User Guide. Swan Service Helpline For model: SR12010 (all colours) SR12010_IM.indd 1 17/02/ :56

T550i power shower pump Installation and operating instructions

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

Model 1174 Electric Heater User instructions for LED effect 2kw Inset Heater

Installation guide Sahara & Sahara Plus

User Instruction Manual

ascent Installation & maintenance instructions Customer/technical services Guarantee Mono basin filler with infrared sensor GUARANTEE REGISTRATION

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Transcription:

Installation and Operating Instructions Zip ChillTap Extra Filtered Ambient and Chilled drinking water Affix Model Number Label Here Page 1 of 8 ChillTap Extra - Installation & Operating Instructions - DOMCT1 - September 2012 v1.04

Contents Safety Information...Page 2 Technical Data / Installation Requirements...Page 3 Spare Parts & Accessories...Page 3 Installation Instructions... Page 3-5 Commissioning...Page 5 Operating Procedure...Page 6 Maintenance...Page 6 Cleaning...Page 7 Service...Page 7 End of Life Disposal...Page 7 Warranty Information...Page 8 Contact Details...Page 8 Safety \ Information Please read all installation requirements, installation procedures and precautions before installing any Zip ChillTap. Never attempt to install any Zip ChillTap without reading all of the applicable instructions. Installation, commissioning and maintenance of this appliance must only be carried out by a competent installer who will then be responsible for adhering to all relevant standards and regulations. Appliance to be wired to a double pole switched fused spur with a minimum breaking capacity of 13A. Installation must comply with current IEE regulations and any Local Authority requirements. This appliance must be earthed. Check that the power supply is switched off prior to electrical connection. The appliance, its wiring and piping must not be modified in any way. In case of malfunction isolate the power supply immediately. In case of leaks also isolate the water supply. Repairs must only be carried out by Zip Heaters (UK) Ltd or an authorised Zip service engineer. If the power supply cable is damaged it must be replaced by a Zip Service Engineer or a qualified electrician. The power supply cable must be adequately secured and power outlet must be in a safe and accessible position after installation. Check that the power supply is switched off prior to electrical connection. Do not remove the appliance cover under any circumstances without first isolating the appliance from the power supply. This unit is designed for indoor use and must not be installed outdoors or exposed to the elements. This appliance must not be used by any person (including children) with limited physical, sensorial or mental abilities or failing experience and / or knowledge unless they are supervised by a person responsible for their safety or received instructions about how to use the appliance. Children should be supervised in order to make sure that they do not play with the appliance. The appliance must only be used when correctly installed and in perfect working order. This product is approved to the LVD and EMC directives and CE endorsed. Zip Heaters (UK) Ltd cannot be held liable for any damages caused by failure to observe these instructions. Please leave these instructions with the end user after installation. Caution! Refrigerant The ChillTap contains R134a refrigerant under pressure. No part of the unit should be exposed to a naked flame. Maintenance of the refrigeration unit must be carried out by an accredited service provider or qualified refrigeration mechanic. ChillTap Extra - Installation & Operating Instructions - DOMCT1 - September 2012 v1.04 Page 2 of 8

Technical Data / Installation requirements Chilled Water Weight Weight Chilled Ambient Initial Draw Recovery Total rating Under-Sink Model glasses* per hour Empty Full Water Water Glasses* Glasses* Watts W x H x D @ 7-12 C Kg Kg DOMCT1 ü ü 60 8 60 245 17.8 19.8 353 x 253 x 377 *Standard Glass = 200ml Power supply: 220-240V AC 50Hz for connection via a double pole switched fused spur with a minimum breaking capacity of 13A. Operating temperatures: 5ºC - 35ºC. Installation Requirements: A potable water supply with a minimum supply pressure of 0.07 MPa - 0.7 MPa (0.7 bar to 7 bar). For best results we recommend minimum static pressure of 0.2 MPa (2 bar). NOTE: You must separately supply and install an isolating valve in the supply line before the connection to the product. Site the chiller unit into the cupboard as close to the proposed outlet tap position as is possible, to minimise the length of tubing exposed between the chiller unit and the tap. Allow at least 50mm around the chiller unit to permit free airflow. Both the top and the front of the chiller must remain accessible for servicing purposes. Spare Parts & Accessories Font Kit...ZT004 Sub Micron Filter...ZT002 Pressure Reducer set at 0.35 MPa (3.5 bar)...aq3 *Water Block (Water Shut Down System)...HE45004 HE45004 *The recommended optional Water Block is ideal for limiting potential leakage and resulting water damage from water chillers and their supply pipe work which are subject to mains water pressure. It is easily installed via standard 3/4 BSP water connection and can be pre-set from 5 to 50 litres. The Water Block also incorporates a non-return valve. Installation Instructions Installing the Chiller Site the chiller unit in the cupboard as close to the proposed outlet tap position as is possible to minimise the length of tubing exposed between the chiller unit and the outlet tap. Allow at least 50mm around the chiller unit to permit free airflow. Both the top and the front of the chiller must remain accessible for servicing purposes. Installing the Tap Position and install the tap at the back of the sink or on the Font where there is a minimum 52mm wide flat area within the draining area of the sink. NOTE: The diameter of the base of the tap is 50mm. Make sure the selected position allows the carafe filler spout to overhang the sink bowl. Use a 35mm sheet metal punch to create a neat hole without burrs. Remove the large nut with the brass and rubber washers from the base of the tap, leaving the rubber-sealing ring (o-ring) in place. Page 3 of 8 ChillTap Extra - Installation & Operating Instructions - DOMCT1 - September 2012 v1.04

Installation Instructions cont. John Guest connections Cut tubing squarely with a sharp knife or tube cutter. Shake out and remove any swarf and debris. Fit the tap and seal to the sink, oriented so both the operating levers are easily accessible. Slide the rubber washer then the brass washer, followed by the nut, over the plastic tubes from under the sink, tighten the nut to secure the tap firmly into place. Install the Filtration Unit 1. The filtration unit should be mounted as close as possible to the front of the cupboard, to allow for ready and easy access during filter changes. Usually the side of the cupboard, near the door, is most suitable. 2. Using the two screws provided, screw the filter head to the inside of the cupboard, allowing 260mm miniumum between the underside of the filtration head and any obstructions like shelves, etc. 3. Write the installation date on the filter cartridge. Fit the cartridge into the housing. The model you have may appear slightly different to that illustrated, however, operation and function is identical. 4. Align the tabs of the cartridge with the filter housing and insert it into the socket. Turn the cartridge a quarter turn to the right until it stops and locks into position. Ensure Plug is Fitted Clear Blue 5. Check that the direction of flow on the filter head is correct. Connecting: NOTE: You must separately supply and install an isolating valve in the supply line before the connection to the product. Minimum supply pressure must be 0.07 MPa (0.7 bar). For best results we recommend a minimum static pressure of 0.02 MPa (2 bar). If the pressure exceeds 7 bar, you must also supply and install a 0.35 MPa (3.5 bar) pressure-limiting valve. (See Spare Parts & Accessories page 3) White OUTLET INLET Flow JG Nut+Straight Connector Filter Under Counter Chiller ChillTap Extra - Installation & Operating Instructions - DOMCT1 - September 2012 v1.04 Page 4 of 8

Installation Instructions continued Mains Supply Connection: Fit the JG Nut + Straight Connector Assembly to the isolating valve. With 1/4 white tubing, connect the Straight Connector Assembly to the inlet of the filter. From the outlet of the filter, connect the 1/4 white tubing from the tap, via the Tee piece supplied. The branch line from this Tee piece must connect to the JG fitting marked INLET on the top right rear of the chiller. Cut excess off to ensure a neat job. Make sure all connections to John Guest fittings are pushed in past the o-ring to full depth, at least 15-16mm. Chiller Connection: Use the blue tube from the tap, cut to length and connect to the JG fitting marked OUTLET on the top left rear of the chiller unit, Insulate the 1/4 blue tube with the supplied pipe insulation. Locate the 1/4 clear (vent) tube from the tap and connect this to the JG connector. Ensure the JG plug is fitted to the connector as shown in the diagram opposite. Make sure all the connections to the JG fittings are pushed in past the o-ring to the full depth, at least 15-16mm. The Tap connection is now complete. Take care, when bending rigid plastic tubing, to prevent it from kinking or crushing around a bend. As it is plastic tubing containing water under mains pressure, be careful not to nick, scratch or damage it during installation. Ensure there is adequate ventilation available through the cupboard. If there is inadequate ventilation, and the cupboard temperature rises to above 40 C, the chiller may become damaged and malfunction which will void the product warranty. The air temperature should be no more than 35 C. There must be a minimum 168cm 2 of cupboard cross-flow ventilation. Suitable holes or vents will need to be cut into the cupboard and door. For safe operation, thoroughly flush the water through after non-use periods longer than 12 hours. Filter cartridges should be replaced at least every 6-12 months, or sooner if you notice: A. A persistent reduction in water pressure from the product, or; B. An unpleasant taste or odour in the water. Not changing the cartridges when required may cause the water to become biologically unsafe. Dispose of packaging wisely. Commissioning Clip the tubing in the cupboard. After the appliance is installed and connected, turn ON the water supply. Check all connections for leaks. Repair any leaks found. The filter, chiller and tubing will be full of air until purged. Turn the chilled operating lever on the ChillTap for a minimum of five minutes until all of the air has been purged from the system and the filter has been primed. Every time the filter cartridge is replaced, repeat the procedure of a five minute flush to activate the new cartridge properly. Connect the unit to the electrical supply. DO NOT turn ON until after the unit is purged. Wipe clean and dry the area. Page 5 of 8 ChillTap Extra - Installation & Operating Instructions - DOMCT1 - September 2012 v1.04

Operating Procedures ROTATE Operation: The lever on the right is used for chilled filtered water and the other, on the left, is used for ambient filtered water. Chilled water is obtained by rotating the lever on the right, to a horizontal position. The water is chilled by a refrigeration unit fitted within the cabinet, under the sink. With the tap, you can obtain chilled water within the rated capacity, for as long as you leave the lever in the open (horizontal) position. When finished, return the lever to the OFF (upright) position. Ambient water is obtained in the same way as the chilled water, by rotating the lever on the left hand side of the tap. Maintenance Filter Replacement The Zip ChillTap Under Counter Chiller has a separate filtration system connected to the incoming water supply line. For safe operation, the filter cartridge should be replaced every 6-12 months, or earlier if you notice a persistent reduction in water pressure from the appliance or an unpleasant taste or odour in the water. WARNING Not changing filtration cartridges when required, may cause the water to become biologically unsafe. Make an entry in your diary to check the water quality of the ChillTap at least six months after installation and after every subsequent filter change. Use only a Zip ZT002 Filter to match that used with this ChillTap. Replacement filter cartridges can be obtained through plumbing suppliers or directly from Zip. Replacement instructions come with the filter cartridges. Before attempting to disconnect or remove the filter cartridge from the housing, isolate (turn off) the water supply prior to the filter system, and then relieve the system pressure by operating the chilled water outlet tap until the water ceases to flow. ChillTap Extra - Installation & Operating Instructions - DOMCT1 - September 2012 v1.04 Page 6 of 8

Cleaning Never use strong, corrosive or abrasive cleaning materials on the Zip ChillTap. Wipe clean the outer surfaces with a sponge or a soft cloth using a mild soap and water. The louvres on the sides of the chiller unit need to be kept free of dust and lint to permit free flow of air through the vents. They should be checked regularly, at least monthly, and dusted or vacuumed. Service There are no user serviceable parts but there are dangerous voltages present within the unit. All service work must only be carried out by a suitably qualified and experienced service person. Before calling for service, check that both the water and electricity supplies are turned ON and OK. Call an electrician, a plumber, or Zip for assistance, service, spare parts, or enquiries. Zip customer service 0845 602 4533. End of Life Disposal In order to help preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer service for advice on 0845 602 4533. The use of this crossed out wheeled bin logo indicates that this product needs to be disposed of separately to any other household waste. Within each of the European Union member countries, provisions have been made for the collection and recycling of unwanted electrical and electronic equipment. In order to preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service for advice on 0845 602 4533. Page 7 of 8 ChillTap Extra - Installation & Operating Instructions - DOMCT1 - September 2012 v1.04

Warranty Certain warranties may be implied by law into your contract with Zip. The warranty provided below is additional to these implied warranties and nothing set out below shall limit your statutory rights or rights at law. Zip Heaters (UK) Ltd warrants that, should any part fail within 12 calendar months of installation, that part will be repaired or replaced free of charge by Zip or its Distributor or Service Provider, except as set out below, provided the appliance is installed and used strictly in accordance with the instructions supplied, and that failure is not due to accident, misuse, abuse, unsuitable water conditions, or to any alteration, modification or repair by any party not expressly nominated by Zip. No costs are payable by the customer other than any mileage or travelling-time charges incurred by a Zip Service Provider or the cost of removal, cartage and re-installation of any component of the appliance if it needs to be returned for repair to Zip or its Distributor. This warranty does not cover damage resulting from non-operation of the appliance, the use of non authorised parts or consequential damage to any other goods, furnishings or property. No warranty applies to the life of any filtration cartridge installed with the appliance as cartridge life may vary according to water quality and the rate of water consumption. Zip does not exclude, restrict or modify any liability that cannot be excluded, restricted or modified or which cannot, except to a limited extent, be excluded, restricted or modified as between the owner or user and Zip under the laws applicable. Furthermore, this warranty does not displace any statutory warranty, but, to the extent to which Zip is entitled to do so, the liability of Zip under any statutory warranty will be limited at Zip s option to the replacement of the appliance or supply of equivalent appliance, the payment of the cost of replacing the appliance or acquiring an equivalent appliance, or the payment of the cost of having the appliance repaired or the repair of the appliance. Registering Your Purchase Registering your Zip installation on the Zip website may help to establish date of installation should it become necessary to service the appliance under terms of the Zip warranty. To register your installation go to www.zipindustries.co.uk and look under the heading Warranty. As Zip policy is one of continuous product improvement, changes to specifications may be made without prior notice. Images in this booklet have been modified and may not be true representations of the finished goods. Contact Details Zip Heaters (UK) Ltd, 14 Bertie Ward Way, Dereham, Norfolk, NR19 1TE Telephone: 0845 602 4533 Fax: 01362 692 448 Web: www.zipindustries.co.uk e-mail: info@zipindustries.co.uk ChillTap Extra - Installation & Operating Instructions - DOMCT1 - September 2012 v1.04 Page 8 of 8