ULTIMA X5000. MSAX5000.com

Similar documents
S5000 Gas Monitor. GMS5000.com

PrimaX IR Gas Transmitter Designed for Reliable Performance in Extreme Conditions

ALTAIR 5X Multigas Detector Product Specification

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8310 IR Detection of flammable gases and vapour

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Model D12-IR. Digital Gas Transmitter...

OLC(T) 100 FIXED GAS DETECTOR

ALTAIR 5X Multigas Detector

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Certificate of Compliance

Dräger Polytron 5720 IR Toxic Gas Detection

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

3M Oldham OLCT 100. Description. Fixed Gas Detector

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dependable Solutions for Gas Detection

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 8310 Stationary gas detector (DSIR)

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Dräger Polytron 8000 Stationary gas detector (EC)

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Detection of carbon dioxide

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Flame 2100 Flame Detection

VENTIS PRO SERIES. Product Guide

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Zareba Sensepoint Pro

Dräger Flame 2500 Flame Detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

MSA Portable Gas Detection

ALTAIR 5X Multigas Detector

IT S WHAT S INSIDE THAT

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

GasAlertMicroClip X3 Specifications

Dräger Polytron 5100 EC Detection of toxic gases and vapors

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Dräger Flame 2500 (IR3) Flame Detection

SAFETY MANUAL. IR5000 Open Path Hydrocarbon Gas Monitoring System

FUNCTIONAL SAFETY MANUAL

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Sieger Apex. Flexibility that meets your requirements

Dräger X-am 7000 Multi-Gas Detection

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

MSA Customer Service MSA-INST

Dräger PIR 7000 Flammable Gas Detection

Certificate of Compliance

Chillgard Refrigerant Monitor

FUNCTIONAL SAFETY MANUAL. Gassonic Observer-H and Observer-i Ultrasonic Gas Leak Detector

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2350 (UV&IR) Flame Detection

Two-Channel Gas Controller

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Dräger Flame 2100 (UV) Flame Detection

Dräger PIR 7200 Detection of toxic gases and oxygen

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Xgard. Fixed detectors For flammable, toxic or oxygen gases

IT S WHAT S INSIDE THAT COUNTS

Dräger Flame 2370 (UV&IR) Flame Detection

IT S WHAT S INSIDE THAT COUNTS

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Dräger Polytron 7000 Fixed gas detector

Dräger X-am 2500 Multi-Gas Detection

SenSmart Universal Gas Detector Series

Model D12. Digital Gas Transmitter

GAS PLUS ALARM SYSTEM

Oxygen (O2) Single-Point Gas Detection System

Dräger Polytron 8100 EC Detection of toxic gases and vapors

IT S WHAT S INSIDE THAT COUNTS

Dräger PIR 7200 Toxic Gas Detection Transmitter

SAFETY MANUAL. Intelligent Sensors for H 2 S Gas Applications

Dräger PIR 3000 Detection of flammable gases and vapours

Net Safety ST3 XChem Toxic Gas Sensor

SUPREMATouch Modular Fire & Gas Detection System

Dräger Polytron 8000 Stationary gas detector (EC)

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Dräger X-am Dräger X-am 7000: Modular, rugged and waterproof.

EXAMPLES OF HOW TO ORDER

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

EXAMPLES OF HOW TO ORDER

Safe Operation Manual. Honeywell IQ Force Gas Detector

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

YOUR PARTNER IN FIRE & GAS DETECTION

Transcription:

ULTIMA X5000 MSAX5000.com

WE KNOW YOU RE TIRED OF... NEEDING TO DISCONNECT POWER BEFORE CHANGING A SENSOR REMEMBERING HOW TO CALIBRATE THIS THING HAVING TO PULL SO MUCH WIRE AT EVERY GAS DETECTOR INSTALLATION... WONDERING IF THE GAS DETECTOR IS WORKING YOU HAVEN T BEEN ABLE TO DO ANYTHING ABOUT IT... UNTIL NOW LOSING MY MAGNET... I HAVE BIGGER THINGS TO WORRY ABOUT

BLUETOOTH CONNECTION STATUS ALL NEW DESIGN GAS READING GAUGE AND PROGRESS BAR ACTIVE OPERATION INDICATOR BRIGHT STATUS LED INSTRUMENT STATUS INDICATORS Power Fault Alarm STAY CONNECTED. WORK SMARTER. Bluetooth wireless technology Check status and get alerts up to 23 m away Modify settings/setpoints/alarms Initiate calibration and view progress Reduce setup time by at least 50% MSAsafety.com/detection

2 INTEGRAL PIPE MOUNT BRACKET 3/4 NPT OR M25 THREADS DUAL SENSORS AND ANALOG OUTPUTS DO MORE WITH LESS 1 Transmitter = 2X Sensing Power SIMPLE RETROFITS Identical footprint and wiring to the ULTIMA X Series

TOUCH INTERFACE FOR TOOL FREE OPERATION Combustible, Toxic or Oxygen Digital Sensors POWERED BY WITH (ACTUAL SIZE) TAG ATTACHMENT MULTI LINGUAL TEXT MENU OPTIONS SafeSwap Safely and quickly replace sensors without turning off the instrument MATERIAL: Stainless Steel Ultra Corrosion Resistant 4 kg (XIR Plus Sensor shown) Dual sensing capability for any combination of sensors MSAsafety.com/detection

NEW ADVANCED SENSOR TECHNOLOGY Up to 1.5 YEARS between calibrations! TECHNOLOGY only CO & H 2 S XCell Sensors MSA Industry Avg MSA Industry Avg O 2 Toxic (CO/H 2 S) Longer Sensor Life 1 yr 2-3 yrs 5 yrs 5 yrs Sensor Stability % Original Output) Better Stability (Lower Drift) MSA Industry Avg 50% Months 24 Longer Warranties 2 yrs 3 yrs Longer Calibration Cycles 4,5 months 18 months Higher Temperature +50 C +60 C Worry-Free Operation 10 Better Resolution for H 2 S Automatically self-checks 4x/day 0.1ppm 1ppm Data may vary for diff erent gases and configurations

IT MAKES SENSE NO EXCEPTIONS 3 5 12 + years years EXPECTED LIFE WARRANTY PATENTS We re going to help you save Installation 30 % ~ 6,000 Annual Maintenance 50 % ~ 1,300 Over the life of the product 75 % ~ 13K Based on 10 sensors and 2 sensors/transmitter Questions about sensor placement? MSA s new gas and flame mapping service combines 150 years of gas detection experience with 3D technology to help you maximize the effectiveness of every sensor. Check out the link for more information: https://gb.msasafety.com/gas-mapping MSAsafety.com/detection

ULTIMA X5000 Gas Monitor Specifications ComBustIBle Gas sensor type toxic Gas & oxygen sensor type sensor measuring RaNGes typical sensor life sensor performance* product specifications Catalytic Bead (XCell Comb) Infrared (XIR PLUS) Carbon Dioxide CO₂ (XIR PLUS) Carbon Monoxide CO (XCell Toxic) Carbon Monoxide CO H₂-Resistant (XCell Toxic) Hydrogen Sulfide H₂S (XCell Toxic) Oxygen O₂ (XCell O₂) Combustible: 0 100% LEL H₂S: 0 10, 0 50, 0 100 ppm CO₂: 0 2%, 0 5% Vol CO: 0 100, 0 500, 0 1000 ppm CO-H₂ Resist: 0 100 ppm O₂: 0 25% 5 years XCell Sensors 10 years infrared t₉₀ (typical) RepeataBIlIty ZeRo drift (per year) XIR plus < 2 sec. +/ 1% LEL/Vol <2% full scale XCell ComB <30 sec. +/ 1% LEL <5% LEL XCell H₂s <23 sec. +/ 3% <1% full scale XCell o₂ <11 sec. +/ 0.1% Vol 0.2% Vol XCell Co <11 sec. +/ 3% <1% full scale approvals ClassIFICatIoN WaRRaNty approvals operating temperature RaNGe storage temperature RaNGe RelatIve HumIdIty (NoN-CoNdeNsING) *At ambient conditions US Divisions Class I Div 1 Groups A-D, T5, Type 4X, IP66 Class II Div 1 Groups E-G, T6; Class III US Zones Class I Zone 1 AEx db IIC T5 Gb Class II Zone 21 AEx tb IIIC T85 C Db Global Zones Ex db IIC T5 Gb Ex tb IIIC T85 C Db X5000 Transmitter: 2 years XIR PLUS: 10 years source, 5 years electronics XCell Sensors: 3 years CSA, ATEX, IECEx, CE Marking. Complies with C22.2 No. 152, FM 6320, RED, FCC Suitable for SIL 2 environmental specifications XCell: 40 C to +60 C XIR PLUS: 40 C to +60 C (may differ by gas, see manual) 40 C to +60 C 10 95% (XCell Toxics & O₂ ) 0 95% (XCell Comb) 0 95% (XIR PLUS) 257.78 mechanical specifications INput power 10 to 30 VDC, 3 wire, <5W nominal signal output Dual 4-20 ma current source, HART BluetootH Bluetooth Low Energy (BLE) v4.3 or higher (optional) Relay RatINGs 5A @ 30VDC; 5A @220 VAC (3X) SPDT fault, warn, alarm Relay modes Common, discrete, horn NomINal max XIR PLUS 6.7 W power XCell Comb 5.5 W (W/ Relays) XCell Toxic & O₂ 2.8 W XIR PLUS and XCell Comb 9.6 W XIR PLUS and XCell Toxic & O₂ 7.0 W Dual XIR PLUS 11.6 W Dual XCell Toxic & O₂ 3.6 W Dual XCell Comb 10.6 W Dual XCell Comb and XCell Toxic & O₂ 5.5 W emc directive Complies with EN 50270 type 2, EN 61000-6-4, EN 61000-6-3 display Organic LED (multi-lingual) with Contrast Ratio of 2000:1 and View Angle of 160 HaRt HART 7, HART device description language available Faults monitored Low supply voltage, RAM checksum error, flash checksum error, EEPROM error, internal circuit error, relay, invalid sensor configuration, sensor faults, calibration faults, general system 114.3 WIRING RequIRemeNts 149.4 68.58 3-wire (single sensor) or 4-wire (dual sensor) shielded cable. Refer to manual for mounting distances and wire gauge. dimensions and WeIGHt Single XCell Sensor 340.97 144.93 Weight: 4 kg - 316 SS Deep Lid (relay board) 123.44 98.04 Dual Sensor (XCell and XIR PLUS) Short Lid (no relays) Subject to change without notice ID 07-720.2 GB/03 MSA (Britain) Limited, Devizes Tel. +44 (0)800 066 2222 info.gb@msasafety.com MSAsafety.com/detection