Ceiling Concealed Fan-Coil Unit

Similar documents
LOW STATIC HYDRONIC DUCTED UNIT

technical data Fan coil unit FWB small duct unit

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

SeasonMaker Hi-Line Fan-coil Units Model HSS S10 & S12

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Installation & Maintenance Data IM Contents

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

Installation and Maintenance Manual IM

VERTICAL HIGH OUTPUT VHC-IOM INSTALLATION AND MAINTENANCE INSTRUCTIONS VHC INSTALLER MUST BE A TRAINED, EXPERIENCED SERVICE TECHNICIAN

Installation, Operating & Maintenance Instructions. Air Handler Models: AH & AV

1-WAY CEILING CASSETTE FAN COIL UNIT

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Vertical Concealed Fan Coil. FCVC Series MANUAL INSTALLATION, OPERATION, & MAINTENANCE

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

USER S MANUAL AND INSTALLATION INSTRUCTIONS IMPORTANT

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Installation, Operating & Maintenance Instructions. Horizontal Models: LH & HL

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

T-Series Air Conditioner T53 Model

installation, operation & Maintenance manual Floor-mounted Induction units

SYSTEM 2000 CHILLED WATER (CAC) EC SERIES -INSTALLATION OPERATIONS AND MAINTENANCE MANUAL-

Drop-In Refrigeration System

ATKINSON DYNAMICS SPEAKERS

T-Series Air Conditioner T15 Model

T-Series Air Conditioner T20 Model

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

Installation Operation Maintenance. Ductable water unit FWD FWD-SVX01D-E4

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

INSTALLATION & OPERATING MANUAL CWA2 Chilled Water Air Handler with Electric Heat 18,000 60,000 BTUH

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Copyright 2003 and 2005 by The American Institute of Architects (AIA) Modified by MSU Physical Plant / Engineering and Architectural Services

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

installation, operation & Maintenance manual Floor-mounted Induction units acb 30/35

BOTTOM MOUNT REFRIGERATORS & FREEZERS Installation, Operation and Maintenance Instructions

DEHUMIDIFIER DT 850 DIRECTIONS FOR INSTALLATION AND USE

Installation Instructions

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

SPX SERIES PACKAGED AIR CONDITIONING/HEAT PUMP UNITS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Operation & Maintenance Manual

Installation Operation Maintenance

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

KR Series Air Defrost Unit Coolers Operating and Installation Manual

PL Series Premier Indoor Plenum Coils

Installation, Operation, and Maintenance Information

PARALLEL RACK SYSTEM INSTALLATION & OPERATIONS MANUAL With Master Rack Compressor Sequencer

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

ThinLine 3G Vertical Unit Heaters

WMHP Series R410a Heat Pump INSTALLATION INSTRUCTIONS

Verde GSE PCA Bridge and Ground Mount Units 30/45/60/90/120 Tons. Installation and Maintenance Manual

Installation Operation Maintenance

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

Installation Instructions

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Installation Instructions for the LatitudeTM Solaris Stick Light Models SL8C-xxx

Installation Instructions

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

OPERATION AND MAINTENANCE MANUAL. Vertical Fan Coil

FUN I / FUN U FUN I MCP / FUN U MCP FUN V / FUN V MCP

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

TEMSPEC INC. VERTICAL FAN COIL UNIT MODELS TVA, TVE, TVS

Induction Unit. Installation, Operation and Maintenance. Cooling Fresh Air Clean Air

AllStyle Coil Company, LP 7037 Brittmore Houston, TX Phone Fax

SeasonMaker ThinLine Fan-coil Units

RSIF Power Venter USA CAN. Product Information. ... Chapters Mechanical Installation. ... Chapter 3. Electrical Installation. ...

Vertical Stack Fan Coil Units Models: TVA, TVE, TVS

Installation Instructions

Daikin Water Cooling, Heating, and High Capacity Booster Coils

THE BARCLAY HUGGER CEILING FAN INSTALLATION INSTRUCTIONS

SWP. (Models SWP08 through SWP20) IMPORTANT! Read before proceeding! OPERATION & MAINTENANCE MANUAL

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Your safety and the safety of others are very important.

CS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A

SECTION AIR HANDLING UNIT

Fig. 1 - Unit PGD4, PGS4, WPG4

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

M Series Fan Filter Units

SeasonMaker ThinLine Fan-coil Units

OWNER S MANUAL MODEL BW4B SLICER WARMER

SERIES B VERTICAL FLOOR FAN COIL UNIT

ADVANTAGE SERIES KXRP28 AIR-TO-AIR HEAT EXCHANGER

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

Transcription:

Installation & Maintenance Manual IM 745 Group: Fan-coil Part Number: 106333001 Date: November 2009 Ceiling Concealed Fan-Coil Unit Models: THC02, THC03, THC04, THC06, THC08, THC10, THC12

Table of Contents Installation... 3 Receiving... 3 Air duct connection... 4 Drain pipe connection... 4 Pipe connection... 4 Wiring... 4 Maintenance... 4 General... 4 Monthly intervals... 4 Wiring Diagrams... 5-6 Motor... 5 Control... 6 Warranty Return Material Procedure... 7 Replacement Parts... 7 Limited Warranty Consult your local McQuay Representative for warranty details. Refer to Form 933-43285Y. To find your local McQuay Representative, go to www.mcquay.com.! CAUTION! WARNING Sharp edges and coil surfaces are injury hazards. Avoid contact with them. Moving machinery and electrical power hazards may cause severe personal injury or death. Disconnect and lock off power before servicing equipment. NOTICE Installation and maintenance are to be performed only by qualified personnel who are familiar with and in compliance with state, local and national codes and regulations, and experienced with this type of equipment. IM 745 / Page 2 of 8

Installation Receiving All units leaving the McQuay plant are inspected for quality prior to shipment. Carefully inspect all shipments immediately upon delivery. Note visible damage on the carrier s freight bill and request that the carrier send a representative to inspect the damage. This may be completed by telephone or in person, but should always be confirmed in writing. The shipment should be unpacked in the presence of the agent so that the extent of the damage or loss can be determined. The carrier s agent will make an inspection report and a copy will be given to the consignee for forwarding to the carrier with a formal claim. Unit Installation The unit is designed to be concealed in the ceiling. Installation and maintenance should be performed by qualified personnel who are familiar with local codes and regulations, and experienced with this type of equipment. There are holes on the top of the unit for hanging the unit above the ceiling. Please refer to Figure 1., Figure 2., and Figure 3. NOTICE Make sure the top of the unit is level after installation. The drain pan is designed with a little gradient to facilitate drainage. Do Not Level Drain Pan! NOTICE Before installation and running the unit, please check the following: Figure 1. Obstacle Obstacle 1. There must be enough space for the unit installation and maintenance. Please refer to the unit outline and dimensions in Figure 1 for the minimum distance between the unit and obstacles. B A C 2. Mount with the lowest moving parts at least 8 feet above the floor or grade level. 3. Ensure enough space for piping connection and electrical wiring. Ceiling A = 8 in. B = 16 in. C = 16 in. 4. Leave a means for disconnection from the electrical supply according to NEC or local codes. Figure 2. 5. Check whether the hanging rods can support the weight of the unit. 6. The unit must be installed horizontally for proper operation and condensate draining. A Terminal Block 7. The exter nal static pressure must be within the allowable static pressure range. 8. The installing contractor must supply service valves and insulation for water piping in accordance with local codes and regulations. Discharge Air Ceiling Ceiling Access Panel with Air Return Return Air 9. To prevent strain on the wire connections, use either conduit or approved strain relief device. Expansion Screw 10. Confirm that the power has been switched OFF before installing or servicing the unit. Nut Vibration Isolator Hanging Rod Fan Coil Unit Flat Washer Detail A IM 745 / Page 3 of 8

Figure 3. A Ceiling Return Air Plenum Pipe Connection Chilled Water Pipe Connection Connect chilled water pipes to the unit. The water inlet is on the bottom and water outlet is on top. Wiring Wiring connection must be completed according to the wiring diagram on the unit. Discharge Air Return Air Return Air Grille with Filter Nut Vibration Isolator Fan Coil Unit Detail A Expansion Screw Hanging Rod Flat Washer Air Duct Connection Air ducts should be made of galvanized steel and connected to the flange of the unit with a canvas connector. Refer to the unit dimensions. Insert the duct into the flange and fix with screws. Duct connections must be installed in accordance with national and local codes. Drain Pipe Connection - Per Local Codes The drain pipe can be PVC or steel. Connect the drain pipe to the unit. Pipe insulation is recommended to avoid condensation. The suggested slope of the drain pipe is at least 1/8" per foot, but local code will prevail. Refer to Figure 4 for typical piping installation. Figure 4. The unit must be GROUNDED. Installation of all field wiring must comply with NEC and local codes.! WARNING A means for disconnect from electrical supply shall be provided according to NEC or local codes. Confirm that the power has been switched OFF before installing or servicing the unit. Maintenance General A good general maintenance plan will avoid performance loss and unexpected shut-down of the equipment. A dirty filter reduces air flow as well as unit performance. Changing or cleaning the filter is very important. Check the filter monthly and replace or clean as required. Coils should be cleaned of dust, dirt and lint with compressed air or water. They can be vacuumed or brushed with a soft brush.! CAUTION Water coils exposed to freezing temperatures should be drained or anti-freeze should be added to the water circuit to avoid freezing. Return Ball Valve Control Valve Actuator Monthly intervals 1. Inspect and clean the condensate drain pan to avoiding clogging of drainage by dirt, dust, etc. Inspect drainage piping for proper condensate flow. 2. Check and clean the coil. Clean the coil with a low pressure water jet or low pressure air. 3. Clean and tighten all the wiring connections. Supply Gate Valve IM 745 / Page 4 of 8

Dimensional Data THC Horizontal Concealed, with Plenum Box Unit Size A B C D E Number Filters of Fans Size Qty S02 32.05" 17.64" 19.17" 19.96" 18.46" 1 18 1 /8" x 8" x 1" 1 S03 38.74" 24.33" 25.87" 26.65" 25.15" 1 24 7 /8" x 8" x 1" 1 S04 43.86" 29.45" 30.98" 31.77" 30.20" 2 29 7 /8" x 8" x 1" 1 S06 51.73" 37.32" 38.86" 39.65" 38.07" 2 18 7 /8" x 8" x 1" 2 S08 61.57" 47.17" 48.70" 49.49" 47.91" 3 23 3 /4" x 8" x 1" 2 S10 65.51" 51.10" 52.64" 53.43" 51.85" 3 25 3 /4" x 8" x 1" 2 S12 75.75" 61.34" 62.87" 63.66" 62.09" 4 30 7 /8" x 8" x 1" 2 E D FILTER 4 - MOUNTING HOLES 3/8" x 5/8" 2.32" 7.36" CONDENSATE DRAIN 3/4" MPT 1.5" B C A 5.75" 3.38" AIR VENT TOP VIEW Plenum Back with Filter 1.02" 5.63" 9.75" FRONT VIEW 1.40" CONDENSATE DRAIN 3/4" MPT FILTER RA 4-Pipe System 2-Pipe System IM 745 / Page 5 of 8

Wiring (115V/1P/60Hz)(208-230V/1P/60Hz)(265/277V/1P/60Hz) Wiring Diagrams For Models: THCH02, THCH03, THCH04, and THCH06 For Models: THCH08, THCH10, THCH12 For Models: THCH02, THCH03, THCH04, THCH06, THCH08, THCH10, THCH12 (WITH VOLTAGE TRANSFORMER) Wiring (115V/1P/60Hz) (208-230V/1P/60Hz)!!!! (265/277V/1P/60Hz)!! IM 745 / Page 6 of 8

Control Wiring Schematic - Heating/Cooling 2-Pipe With Automatic Changeover Control Wiring Schematic - Heating/Cooling 4-Pipe With Sequencing Thermostat IM 745 / Page 7 of 8

This document contains the most current product information as of this printing. For the most up-to-date product information, please go to www.mcquay.com. 4900 Technology Park Boulevard Auburn, New York 13021-9030 800-432-1342 www.mcquay.com IM 745 Pg 8 of 8