The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps

Similar documents
2012 International Symposium on Safety Science and Technology Advances in dust explosion protection techniques: flameless venting

Industrial Explosion Suppression Technology

A Global Leader in Explosion Protection

Before proceeding with the selection process, let s briefly look at the various explosion protection options:

Combustible Dust Issues

Dust Explosions. health & environmental sciences failure analysis & prevention

APPLICATION PROFILE EXPLOSIONS IN CEMENT PLANTS EXPLOSIONS IN CEMENT PLANTS CEMENT PLANT EQUIPMENT WITH HIGHEST EXPLOSION POTENTIAL. Form No.

1NFPA 68 has changed from a guideline to a

Industrial Dust Explosions Causes & Case Studies. Presented by Geof Brazier at Expocorma, Concepcion, Chile 10th November 2017

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

Understanding. Combustible Dust Hazards: Basic Measures to Ensure the Safety of Combustible Dust Handling Operations

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

2How does a vibratory fluid-bed dryer work?

Aluminum Dust Management in a Metallizing Facility

Explosion Venting and Suppression of Bucket Elevator Legs, G90-990

Fugitive dust accumulations in bulk solids plants have. Preventing explosions: How to safely clean up combustible dusts. Figure 1

HOW WELL DO YOU KNOW YOUR DUST?

Explosion Prevention & Suppression James Maness JEM Safety Consulting Rehoboth, DE.

Flameless Venting The New Technology for Safe Indoor Explosion Venting

Guide - Basic Information

EXPLOSION PROTECTION MAES SAFETY PRODUCTS & SERVICES

There are always options in the management of explosion risks!

PRIMATECH WHITE PAPER PROCEDURE FOR DUST HAZARD ANALYSIS (DHA)

Prevention of Fires and Explosions in Wood Pellet Facilities. Allen Wagoner, FLAMEX, Inc.

GEAPS Great Lakes Regional Conference 2017 Explosion Protection Overview & Market Drivers. April 6, 2017

OUTDOOR INSTALL NO RETURN AIR SINGLE MODULE COLLECTORS OUTDOOR INSTALL WITH RETURN AIR SINGLE MODULE COLLECTORS

DUST COLLECTION TRAINING. Revision 2013

venting method will work for all pressure conveying systems, analyzing your available equipment, your material s characteristics, and your conveying c

White Paper EXPLOSION PROTECTION EXPLOSION PROTECTION SOLUTIONS FOR SANITARY HYGIENIC APPLICATIONS IN THE FOOD & PHARMACEUTICAL INDUSTRY

THE PACESETTER IN EXPLOSION SAFETY INNOVATION EXPLOSION PROTECTION SOLUTIONS YOU CAN COUNT ON WORLDWIDE.

EXPLOSION PROTECTION INTEGRATED COMPONENTS EXPLOSION PROTECTION SOLUTIONS EXPLOSION PROTECTION INNOVATIVE, RELIABLE, PATENTED TECHNOLOGIES

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Combustible Dust Hazard Recognition and Control NFPA Standards for Combustible Dusts

1. Delete in its entirety as follows:

Protecting Critical Facilities Against Explosions

COMBUSTIBLE DUST HAZARD MITIGATION

With CV Technology products and care, you ll be better protected from dust explosions.

DuPont Formacel Z-2. Safety and Handling of DuPont Formacel Z-2: Thermoplastic* Foam Extrusion Applications FOAM EXPANSION AGENT TECHNICAL INFORMATION

Progressive Safety Services LLC 1

MEMORANDUM. NFPA Technical Committee on Solvent Extraction Plants. NFPA 36 First Draft TC FINAL Ballot Results (F2016)

M E M O R A N D U M. NFPA Technical Committee on Wood and Cellulosic Materials Processing

Leading Trends in Chemical Processing

BHA Powerwave Acoustic Cleaning Systems Powerful cleaning to help increase performance

Combustible Dust Awareness. David McEwan Business Line Manager Configured Products

Q-Box-II LF- NFPA 654

Managing explosive dust risk in sugar handling

Explosion Protection. Process Safety. Quality Solutions.

Property risk solutions

Advances in Explosion Protection Technology. Dr. John E. Going Fike Corporation Blue Springs, MO

COMBUSTIBLE DUST HAZARD RECOGNITION

COMBUSTIBLE DUST SAFETY PROGRAM

First Revision No. 1-NFPA [ Chapter 2 ]

Protecting Facilities Against Explosions. Since 1956

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Combustible Dust Booklet

We ve all heard about catastrophic combustible

Jason Reason. NFPA Technical Committees

Ontario Fire Code SECTION 5.10 COMBUSTIBLE DUST PRODUCING PROCESSES. Illustrated Commentary. Office of the Ontario Fire Marshal

The correlating committee has revised the numbering in these sections to provide clarity for the next edition of the document.

Safe installations are also cost effective installations

Public Input No. 3-NFPA [ Chapter 2 ]

INTRODUCTION TO DUSTS AND THEIR EXPLOSIVE PROPERTIES

Combustible Dust Resources OVERVIEW OF COMBUSTIBLE DUST. What is Combustible Dust? Where are Combustible Dusts found?

WHITE PAPER Dust Hazard Analysis for Simple Dust Collection Systems

Managing Combustible Dust

GASEOUS HYDROGEN SYSTEMS

Combustible Wood Dust Management Program Development Guide

Leading the world in explosion protection

Vent-Saf. BSBsystems.com BSBipd.com Visit our website for the most complete, up-to-date information

Reference to the Smoke Damage Index (SDI) is needed as it is part of the test method.

Dust Collection Tips to Keep Free-From Foods Safe from Cross-Contamination

ASKING THE RIGHT QUESTIONS ABOUT CARTRIDGE DUST COLLECTION

Combustible Dust 101: Understanding Combustible Dust Hazards

NEC Requirement Guidelines 2002 Code Options for the Installation of Listed Less-Flammable Liquid-Filled Transformers

3/20/2017. The Impact & Implications of NFPA 652 NFPA s Newest Combustible Dust Standard. Jason Reason. Jason Reason

WHITE PAPER. Dry Media Dust Collector or Wet Scrubber? Selecting the Right Equipment for Combustible Dust

NFPA 33 Standard for Spray Applica4on Using Flammable or Combus4ble Materials

Combustible Dust Hazards- Awareness

Smoke detection in hazardous areas:

General Design Practices in Reducing Risk in Grain Handling Facilities

Identifying and Preventing Dust Fire and Explosion Hazards

REMBE EXPLOSION SAFETY

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL XP DRUM KIT PATENT PENDING UTILITY 35 USC 111(A)

Fire Protection Guidelines for Handling and Storing PRB Coal

Moisture can be very disruptive to a dust. Preventing moisture problems in your dust collector

Overview of Hazardous Locations as They Relate to Solenoid Valves

Pneumatic Vacuum Conveyors for the Highest Standards Transportation of bulk materials in the pharmaceutical and chemical industries

HYDROCARBONENGINEERING June June 2015

ADDITIONS TO NFPA 61, STANDARD FOR THE PREVENTION OF FIRES AND DUST EXPLOSIONS IN THE AGRICULTURAL AND FOOD PROCESSING INDUSTRIES

Revitalize Building Mechanical Systems (4619)

Compliance Guidance for non-technical managers

AUTOMATIC FIRE SUPPRESSION SYSTEMS

M E M O R A N D U M. The Technical Correlating Committee on Boiler and Combustion Systems Hazards

Kice Dust Control System Design and Maintenance Basics Design, Maintenance, & Operation

10 Tips on Selecting Cartridge Dust Collection Equipment for Tablet Presses

PORTABLE PILOT TEST UNIT. Mike Hill Shirco Infrared Systems, Inc.

GARN WHS 3200 Addendum to the Owner s Manual

As long as ATEX has been providing Explosion. Protection Systems a truly passive System without many

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Air Pollution Control Equipment & Service Needs

Transcription:

Meeting explosion safety requirements with flameless venting Jef Snoeys Fike Corp. Flameless venting is a recently developed technology for protecting indoor equipment from dust explosions. This technology provides a ready solution for some applications where conventional explosion venting can t provide the required protection. After describing the flameless venting device and how it works, this article explains how to select a device that complies with National Fire Protection Association requirements. Flameless venting is a relatively new dust explosion protection method for indoor equipment that combines conventional explosion venting with flamequenching techniques. Flameless venting devices meet increasingly strict explosion safety regulations for bulk solids plants and overcome the limitations of conventional ducted explosion venting in some applications. Flameless venting devices can also be retrofitted to existing equipment installations. The need for flameless venting Conventional explosion venting has long been the most common method of protecting indoor process and storage vessels, enclosed conveyors, and other equipment from the effects of a dust explosion. An explosion vent is an opening in a vessel s top or side that provides pressure relief during an explosion. Ducting directs the vent discharge outside the building, protecting people indoors and preventing dust deposits outside the vessel from becoming involved in a secondary dust explosion. This ducting has a substantial effect on the pressure experienced inside the vessel during the venting process, and the vent area calculation must allow for this effect. 1 However, in some cases, the pressure increase can be so great that an alternative protection method is required. The flameless venting device provides a ready solution for these cases by combining explosion venting and flamequenching techniques. The device can be added to existing equipment, allowing bulk solids processors to retrofit their equipment to meet today s more stringent explosion safety regulations. In the US, flameless venting devices must comply with the National Fire Protection Association (NFPA) standard NFPA 68: Standard on Explosion Protection by Deflagration Venting (2007), 2-3 which OSHA has the authority to enforce. In Europe, the devices must comply with European Standard pr EN 16009 Flameless explosion venting devices. 4 This article concentrates on US requirements. While the flameless venting device is used primarily on indoor equipment, it s also well-suited to outdoor equipment that s adjacent to buildings or roads, where a vented explosion s flame and pressure effects can t be safely controlled. The flameless venting device can be used in most applications handling nontoxic dry bulk materials. How a flameless venting device works Components. A flameless venting device, as shown in Figure 1, is a passive device that typically includes an explosion vent panel and a flame-quenching element that s inside a flanged metal frame; the frame attaches the element to the process equipment, such as a dust collector.

The element is closed at one end and open at the other, and it s bolted onto the explosion vent opening on the equipment so that its open end overlaps the opening. The flamequenching element s frame encloses layers of particle-retaining, high-temperature stainless steel mesh or carbon steel mesh, as shown in Figure 2, or ceramic material. The flame-quenching element may be cylindrical, rectangular, or square to fit the vent opening s shape. Lifting rings (for supporting the device) Figure 1 Flameless venting device (exploded view) Metal frame Flamequenching element Operation. During the early stages of an explosion inside the process equipment, the explosion vent panel opens. As the explosion expands, flame and burnt and unburnt dust discharge through the open vent into the flame-quenching element. Most of the dust is retained inside the element, and the energy (heat) dissipates as it travels through and is absorbed by the steel mesh or ceramic material inside the element. This reduces the burning fuel s temperature below the fuel s ignition temperature, extinguishing the flame and preventing flame propagation beyond the device. Only a small amount of dust passes through the flame-quenching element, and post-combustion gases from the explosion are safely vented through the device into the external atmosphere around it. The flameless venting device s operation not only extinguishes the flame and retains dust, but eliminates the need for explosion vent ducting and minimizes the vent relief area required for indoor explosion venting. Available types. Flameless venting devices of various shapes are shown in Figure 3. Many are designed to suit particular storage and process equipment such as silos, bins, hoppers, dryers, mixers, dust collectors, and cyclones, and handling equipment such as enclosed belt conveyors, screw conveyors, and bucket elevators. Bolts Explosion vent panel Gasket NFPA 68 provides detailed guidance for calculating the flameless venting device s explosion relief area and designing the venting system to ensure that the device complies with applicable explosion safety guidelines. Flange (bolting plate) Figure 2 Layered steel mesh inside flame-quenching element Selecting the device to comply with NFPA 68 When selecting a flameless venting device, you ll need to work closely with the manufacturer to ensure that the device will provide safe explosion venting in your application. NFPA 68 provides detailed guidance for calculating the flameless venting device s explosion relief area and designing the venting system to ensure that the device complies with applicable explosion safety guidelines. The standard applies to the design, location, installation, maintenance, and use of equipment that vents deflagrations from enclosures to minimize structural and mechanical damage. NFPA 68 addresses several key requirements for flameless venting devices (called flame-arresting vent systems and particulate retention vent systems in the standard). The standard: Discusses limitations and safety considerations for flameless venting devices and states that, when selecting a device, the user should consider the room s volume, how

Figure 3 Flamelessventingdevicesofvariousshapes a. Round (on a hopper) b. Rectangular (on a bucket elevator) close personnel will be to the device, whether a combustible mixture may be present outside the equipment, and whether the equipment may release toxic emissions. States that the flameless venting device must cool explosion gases, prevent flame from emerging, and greatly reduce near-field blast effects (overpressure) outside the equipment. Discusses the need to consider effects of overpressure when venting equipment within a building. Even when the device completely retains flame, the area immediately surrounding it can experience overpressure and radiant energy (heat). To limit overpressure, the user must consider the expected overpressure in relation to the plant building s strength and consider adding building venting. [Editor s note: Find advice on how to do this in the section More selection advice. ] States the need for the user to work closely with the venting device manufacturer to ensure that the previous three parameters are addressed. c. Square (on a dust collector) Because there s no formal certification process in the US for flameless or other venting devices, you ll need documentation from the manufacturer (and any installing contractor) to ensure that the flameless venting device will satisfy NFPA 68 requirements. This includes documentation that states the device has been manufactured and installed according to NFPA 68. The manufacturer should also document the device s design according to NFPA 68 Table A.11.2 and provide a vent sizing calculation sheet and a certification that the calculations comply with NFPA 68 requirements. Calculating the device s required vent relief area An important part of designing a flameless venting device that complies with NFPA 68 requirements is to calculate the device s proper size that is, its required vent relief area for the application. This requires considering the device s overall venting efficiency. Venting manufacturers perform large-scale testing of their flameless venting devices to determine the overall venting efficiency correction factor for these devices in comparison with a conventional explosion vent s efficiency. 5 This is because the flamequenching element on the flameless device restricts the flow of flame and gases from the vent opening and reduces the effective explosion-relief area compared with that of a conventional vent. This correction factor must be applied to vent area calculations to yield the required vent relief area increase for the flameless device over the conventional vent s required vent relief area. Let s consider an example application, in which we ll determine what type and size of venting to install on a cylin-

drical hopper handling wood fiber. The hopper, which is installed indoors, requires either a conventional explosion vent with ducting to the outdoors or a flameless venting device; the flameless venting device must have FM Global approval. 6 The hopper has a 50-cubic-foot volume and length-to-diameter ratio of 1, giving the vessel a compact rather than elongated shape. The hopper has a P stat (relief device [or burst panel] static opening pressure) of 1.45 psi and a P red (reduced explosion pressure; that is, the maximum calculated pressure developed in the hopper during a vented explosion) of 4.5 psi. Based on material characterization testing, we ve determined that the fibrous wood dust has a K St (the dust s maximum rate of pressure rise normalized to a 1-cubic-meter volume) of 120 bar-m/s and a P max (the dust concentration s maximum explosion pressure) of 102 psi. Using the vent area calculations in NFPA 68 with these vessel and dust parameters, we calculate the required vent relief area for this hopper to be 1.0 square feet (144 square inches). To select a conventional explosion vent that can provide this required vent relief area, we use the NFPA 68 vent area calculations for this device with our vessel and dust data. The hopper s indoor location requires designing, constructing, and installing a vent duct leading to a safe flame discharge area (with a typical perimeter of about 66 feet) outside the building wall. The NFPA 68 vent area calculations for a ducted explosion requires a vent relief area of 2.54 square feet, so we select a 24-inch-diameter round vent. Installing the vent duct will also require penetrating the wall. To select a flameless venting device that can provide the required vent relief area in this application, we use the NFPA 68 vent area calculations for flameless venting devices with a 54.2 percent venting efficiency correction factor (determined from tests of one manufacturer s 8- to 20-inch flameless venting device 7 ). This gives: Note: The venting efficiency factor for any conventional explosion vent or flameless venting device is specific to the manufacturer and often to the application, as well. Select either type of device based on the manufacturer s recommendation. More selection advice Some application limits. The equipment volume that a single flameless venting device can protect is limited, so be sure that you know this limit for the device you select. Because flameless venting is a relatively new technology, manufacturers have yet to complete extensive performance testing of the device on large-volume vessels such as silos. If you re planning to use a flameless venting device on a silo or other large vessel, work closely with the manufacturer to ensure that the device is properly selected for your vessel. If your equipment handles a fibrous dust, be aware that it has a greater tendency to clog the flame-quenching element than other dusts; for such an application, consult the manufacturer for selection guidance. The flameless venting device isn t suitable for applications handling toxic materials or metal dusts. Approaches for limiting building overpressure. Also consider how to limit overpressure in your plant building resulting from the flameless venting device s operation, as discussed in NFPA 68. This requires determining the expected overpressure the flameless venting device will produce in relation to the building s strength and considering whether you need to add venting to the building to handle the overpressure. One practical approach is to use a vol- Required flameless venting device area = 1.0 square feet/(54.2/100) = 1.85 square feet (266 square inches) One 20-inch flameless venting device installed on a 20- inch explosion vent panel on the hopper will supply a 2.02-square-foot vent relief area, exceeding the calculated required area of 1.85 square feet. In addition, the flameless venting device offers these practical advantages: Unlike a conventional explosion vent, the flameless venting device eliminates any need for vent ducting and, thus, any need to penetrate the building wall to vent explosion flames. A flameless venting device combines conventional explosion venting with flame-quenching techniques.

ume ratio between the protected equipment and the building containing it. Typical ratios are 1:9 for a reinforced or vented building and 1:15 for a building not specifically reinforced. So, for example, a 200-cubic-foot storage bin with a flameless venting device would require the building to be vented or reinforced if the building s volume is less than 1,800 cubic feet. You can also use another more or less conservative approach (based on calculating the explosion s pressure increase) if the results of large-scale testing by the device manufacturer support this approach. At installation, provide adequate support for the flameless venting device so that its weight and reaction force during venting won t damage your equipment. Installation, inspection, and replacement advice Because radiant heat, combustion gases, and a small amount of dust are released from the flameless venting device during an explosion, locate the device a safe distance from workers. They should work no closer than a distance equal to 2 times the device s longest side from the device discharge. At installation, provide adequate support for the flameless venting device so that its weight and reaction force during venting won t damage your equipment. For example, some flameless venting devices are equipped with lifting rings (Figure 1) that may be attached to cables, rods, or beams to support the device. Once the device is installed, routinely inspect the device, the explosion vent panel it covers, and the device s support mechanism according to the inspection checklist in NFPA 68 section A.11.4. Keep on file the documentation provided by the manufacturer and installing contractor that states the flameless venting device has been manufactured and installed according to NFPA 68. If an explosion occurs in your equipment and causes the flameless venting device to operate, replace the explosion vent panel the device covers, the flame-quenching element, and the bolts and gaskets attaching the element to your equipment. PBE References 1. For more information on explosion venting and designing vents, see Solids Handling and Processing Association (SHAPA) Technical Bulletin 10: Sizing of explosion relief vents, by Mike Ward, available from SHAPA (www.shapa.co.uk/materials-handling-public.php). 2. Available from National Fire Protection Association (NFPA), 1 Batterymarch Park, Quincy, MA 02169-7471; 800-244-3555, fax 617-770-0700 (www.nfpa.org). 3. Find more information on NFPA 68 explosion venting requirements in these recent Powder and Bulk Engineering articles: Five ways new explosion venting requirements for dust collectors affect you by Lee Morgan and Tony Supine (July 2008, pages 42-49) and Designing your dust collection system to meet NFPA standards by Gary Q. Johnson (Part I, December 2008, pages 53-59; Part II, January 2009, pages 89-95). For information on purchasing articles, see For further reading. 4. For more information on European explosion safety standards, contact the author. 5. For information on recent large-scale tests conducted by Fike Corp., Blue Springs, Mo., contact the author. Find information on Fike Corp. s earlier flameless venting device tests using explosion chambers in Efficiency of flameless venting devices by John E. Going and Kris Chatrathi in Process Safety Progress, March 2003, Vol. 22, No. 1, pages 33-41. 6. FM Global is an insurance company that performs engineering analysis of physical and financial risk to prevent or mitigate property losses to companies; the firm provides third-party FM Approval certification for products, such as venting devices, that protect property from loss. 7. FlamQuench II flameless venting device, Fike Corp., Blue Springs, Mo. For further reading Find more information on explosion venting in articles listed under Safety in Powder and Bulk Engineering s comprehensive article index (in the December 2009 issue and at PBE s Web site, www.powderbulk.com) and in books available on the Web site at the PBE Bookstore. You can also purchase copies of past PBE articles at www.powderbulk.com. Jef Snoeys is manager of the explosion protection technology group at Fike Corp., PO Box 610, Blue Springs, MO 64015; 816-655-4542, fax 816-229-4615 (www.fike.corp). He s a member of the NFPA 68 Technical Committee and the European Standardization Committee CEN TC 305, and heads the CEN TC 305 WG3 SG10 Committee on Flameless Venting. He can be reached at +32-14-849476, fax +32-14-210743 (Jef.Snoeys@fike.com).