Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION. Visit us at

Similar documents
Systems. Visit us at

FREESTYLE SPE UNIQUE POSSIBILITIES FOR SOLID PHASE EXTRACTION

DETERMINATION OF PAH In Particulate Matter PM 10 with SPE/EVAporation

APPLICATION NOTE DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. APPLICATION NOTE As of July 2017, Version: 1.

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

FREESTYLE always ready

FREESTYLE QUATTRO ACCECLEAN ELUVAC GPC COLUMNS IMMUNOAFFINITY COLUMNS SAMPLE SAMPLE PREPARATION PRODUCTS PREP

To request a quote or locate your nearest dealer, contact Customer Care toll-free in the US at or

JSB is an authorised partner of DETERMINATION OF THE HYDROCARBON-INDEX DIN EN ISO :2000. i n s p i r a t i o n m e e t s i n n o v a t i o n!

300 series HPLC autosamplers

DETERMINATION OF PAH In Particulate Matter PM10 With SPE/EVAporation

Thermo Scientific Rocket Evaporator. Revolutionary solvent evaporation complete laboratory workflow

Agricultural. drugs of abuse. Food & Beverage. Pesticides SOLID PHASE EXTRACTION. Inject. Wash Elute. Cartridges. Concentrate. Silica.

RapidTrace + Automated SPE Workstation. Instruments. Accessories Racks Vial Adapters Test Tubes O-Rings Miscellaneous

High Volume Injection up to 5 ml with the Agilent 1200 Infinity Series Online SPE Solution for Highest Sensitivity

Agilent 1290 Infinity II Vialsampler Data Sheet

Customised HPLC Systems for Highest Performance

Spark Holland introduces

Auto SPE-06Plus Solid Phase Extraction System. Reeko Instrument USA

Agilent InfinityLab Online SPE Solution

Automação de SPE utilizando sistema robótico Triplus RSH autosampler. Nova Analitica

Order all the parts and accessories needed at one time Reduced learning curve for rapid implementation

Methods of solid phase extraction. Methods of solid phase extraction

Standard Operating Procedure for Oil & Grease Method EPA1664A

Evaporators, Sealers and other Equipment

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

FREEZE DRYER LYOPHILIZER PRODUCTS LABFREEZ INSTRUMENTS CO., LTD

Automated Solid Phase Extraction (SPE) of EPA Method 1694 for Pharmaceuticals and Personal Care Products in Large Volume Water Samples

Multifunctional individualists

Advancing the power of SPE. Intelligent Automated Solid Phase Extraction. SmartPrep Brochure

AppNote 6/2008. Automated SPE and Fast GC-ECD Analysis of PCBs in Waste Oil KEYWORDS ABSTRACT INTRODUCTION. MACH, Fast GC-ECD, SPE, PCB, waste oil

On-line SPE Enrichment of Trace Organic Contaminants in Water and Juices

Analysis of Pharmaceuticals and Personal Care Products in Groundwater by Online SPE and LC/MS/MS

Online SPE-UHPLC-MS. CHRONOS for Control & System Integration. Flexible autosampler for sample preparation. Superior UHPLC system for analysis

John Morris Scientific Service plus Solutions

Waters 2767 Sample Manager, Injector, and Collector Installation and Maintenance Guide

Rotavapor R-220 Pro Technical data sheet

Application Note. The Agilent 1200 Infinity Series Online SPE Solution for the Highest Sensitivity. Author. Abstract.

SmartPrep Automated SPE Cartridge Extractor II Module

Enhancing Throughput of Online SPE Analysis of Pesticides in Wastewater The Agilent 1200 Infi nity Series Online SPE Solution

HITACHI CHROMASTER. Clarity Control Module. Code/Rev.: M173/70I Date: 6/23/2018

Laboratory Freeze Dryers Routine Applications

VS LD series vertical steam sterilizers

Solid Phase Extraction using the 96-well Format ISOLUTE -96 Fixed Well Plates and ISOLUTE Array 96-well Plates

CALIDUS tm the Modular micro Gas Chromatograph

MEPS - Micro Extraction by Packed Sorbent Online SPE for GC and LC sample preparation - Extraction to injection in a single process

cgmp, FDA and EHEG Compliant Cleaning Equipment (Pharma Grade)

Pilot Freeze Dryers Smart Processes

Installation of Hotel Drawers

Rotavapor R-220 Pro Technical data sheet

Waters 2795 Separations Module

AC1234 PRODUCT RANGE.

An Automated SPE Procedure and Analysis for the Extraction of Chlorpromazine and Thioridazine from Plasma Application Note 213

HydroSpeed plate washer for 96- and 384-well formats

Vacuum Pump V-100 Technical data sheet

PTWS 120D USP/EP Tablet Dissolution Testing Instrument

Agilent 1100 Series Refractive Index Detector. Reference Manual

HydroSpeed plate washer for 96- and 384-well formats

Zoom Microplate Washer and Washer-Dispenser. Reliable Solutions for Your Daily Work

Thermo Scientific Dionex AutoTrace 280 SPE Instrument. Automate Large-Volume. Solid-Phase Extractions

From Sample to Vial. Automated Sample Prep Solutions. Extraction Cleanup Concentration

Supra-Clean and Supra-Poly SPE Solutions. Solid Phase Extraction Columns

BAC 4000a BAC 5000yf

Rotary Evaporators designed

Tubing spares and piping accessories. Gas purification and control 1 Moisture Traps,Carbon traps 2 Gas Purification Panels 3 Gas Control Box

Aquamax KF Oil Evaporator. User Manual

Agilent 1290 Infinity II Online SPE Solution

Soxtherm. C. Gerhardt - Laboratory Instruments. Extraction Systems

Nexera-i Specifications Prominence-i Specifications

The Road to Recovery. Mapping Advanced Sample Preparation Techniques for GC, GC-MS and HPLC Analysis

LABORATORY FREEZE DRYERS ADVANCED PROCESSES

INCREASE YOUR LAB EFFICIENCY

Process and Air Monitoring. Online GC systems for continuous monitoring of organic compounds in air and gaseous samples

Floor model Freeze Dryer

Simplicity. Reliability. Performance. Stratum. Automated VOC Sample Prep System

Industrial, Medical and cgmp-conform Cleaning Equipment

The Viva-ProE System

Zoom HT Microplate Washer. The Fastest Microplate Washer For The Life Sciences

On Line SPE LC/MS/MS Applications

ACQUITY UPLC H-Class Sample Manager - Flow Through Needle Operator s Overview and Maintenance Information

ELISA NIMBUS. Automated ELISA Processing System

Best Freeze Drying Solutions

Labconco XPress Laboratory Equipment Where You Need It, When You Need It

MICROPLATE EVAPORATORS

AUC Cell Washer. User Manual

How Important is Performance to your SPE Method Development?

FIXED GAS ANALYZER (FGA)

Model # VWK-2 INSTRUCTION MANUAL

Tool-free LC connections for HPLC, UHPLC and nano LC systems

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

Glassware Washers. WM Series. Efficient washing results for laboratory glassware

SBI. Single Burning Item - EN THE BENCHMARK IN FIRE TESTING

Agilent Vac Elut SPS 24 Manifold User Guide

DYE QUALITY CONTROL REFERENCE MATERIAL KIT

NEOTeCHA Reactor Sampling Type PV

Typical Sample Preparation Process & Highlighted Areas for Horizon Technology SmartPrep Extractor Automation and XcelVap Evaporation

Vacuum in the laboratory. products and solutions

EQ-ROBO Programming : Cliff Check Robot

XENOSEP. SPE Systems for EPA Method 1664A. The Easiest, Most Cost Effective Way to Increase Productivity

Industrial and cgmp conform Cleaning Equipment

Transcription:

Automated Sample Preparation: SPE GPC - EVAporation SUPERIORITY BY ADAPTATION Visit us at www.lctech.de!

What LCTech does supplies innovative products and methods for the preparation and analysis of food, feed and environmental samples.

Mission Our misson: THE CLEANER THE EXTRACT THE BETTER THE RESULT

FREESTYLE System - Introduction This system is designed for sample preparation mainly in food, feed and environmental laboratories, but can be used in any lab in which GPC and/or any type of SPE columns are used for clean-up

FREESTYLE The Concept FREESTYLE is a system which is based on FREESTYLE BASIC and can be modified with modules SPE module FREESTYLE BASIC GPC module EVAporation in all imaginable combinations

FREESTYLE BASIC FREESTYLE BASIC Valves, syringe pump & others on top of y-axis (reduces dead volume in tubing) xyz-robotic system Rinsing port for needle Flexbile robotic area; the appropriate area can be created at any time by choosing the right racks

FREESTYLE Modules SPE Module SPE module as a 2nd z-axis Universal manipulator for all standard SPE-/ Immuno affinity - (IAC) and Glass columns (e.g. LCTech columns) from 1 to 15 ml Control unit for SPE module

FREESTYLE Modules FREESTYLE BASIC SPE Module

FREESTYLE Modules GPC module GPC-column: different sizes for all known official methods available accessory; not included in the module Injection valve High precision, double piston GPC-pump Exchangeable sample loop

FREESTYLE Modules FREESTYLE BASIC GPC module

FREESTYLE Modules EVAporation module Integrated vacuum pump, heater & electronical devices Solvent recovery/ solvent recycling Water for temperature control of the vacuum chamber Heart of the EVAporation system: EVAporation chamber with sensors

FREESTYLE Modules FREESTYLE BASIC EVAporation Module

FREESTYLE adapted to applications Typical combination of different modules: FREESTYLE BASIC + GPC + EVAporation: For sample preparation (clean up) for pesticides / PAH and all other analytes in fatty matrices which have to be cleaned up before transfering to analytical instruments (eg. GC or LC). Sample preparation for soil analysis For a faster, reliable, more reproducible and more comfortable handling of such samples customer can choose a higher level of automation: FREESTYLE BASIC with GPC module for clean-up and EVAporation module

FREESTYLE Modules FREESTYLE BASIC GPC module EVAporation Module

FREESTYLE modified for applications Typical combination of different modules: FREESTYLE BASIC + SPE + EVAporation: Automation of SPE Handling in all kind of labs For a faster, reliable, more reproducible and more comfortable handling of such samples customer can choose a higher level of automation: FREESTYLE BASIC with SPE module and EVAporation module

FREESTYLE modified for applications FREESTYLE BASIC SPE-Modul EVAporation Module

FREESTYLE fully automated SPE-Modul FREESTYLE BASIC GPC-Modul EVAporation Module

SUPERIORITY BY ADAPTION Your advantage SUPERIORITY BY ADAPTATION

The unique design Sorry, FREESTYLE does not offer 50 or more platforms! FREESTYLE has just one, but you can create this one according your needs, your demands, at any time (no service or tools needed) Racks can be individually positioned by hooking them into a toothed plate

Racks the key for flexibility This pictures shows how it works

Racks the key for flexibility frame = rack tray with vials Frame canbeusedfor different kinds of vials Tray can be taken out of frame and prepared independently

Racks the key for flexibility for vials from 1.0 ml to 1000 ml (e.g. standard flasks, round bottom flasks, TurboVap, Büchi, test-tubes ) racks can be cooled or heated With protection for light sensitive samples Vials and flasks can be sealed with septa = You can choose between r.a. 30 different racks. And if you cannot find the appropriate rack we are sure that we can design it. Ask LCTech!

Powerful Software Selection of individual modules or combination of different functions within a single method (eg. SPE +EVA or GPC+EVA) no hardware changes necessary! Allows intuitive handling and easy usage in daily routine Indicates most of the logical failures done by the customer choosing the wrong parameters Always included in the purchase price of modules

Powerful Software Main Window

FREESTYLE system features Integral system features Extensive safety devices: - Possibility of immediate emergency stop in case of danger or to prevent any dangerous situation - Collisions recognition with the possibility to proceed without loss of sample All liquid containing tubing is located outside the instrument, thus easily accessible and strictly separated from any electric wiring Plausibility check of software input Software is always included in the modules

FREESTYLE - Standards of production Standards of development and production & safety guidelines Developed and produced at highest level according to Machine Directive 2006/42/EC of the European Parliament and of the Council of 17 May 2006 on machinery, and amending Directive 95/16/EC (recast), including CE certification. Developed and produced according to ISO 9001:2008. CE labelled safety guidelines

SPE Module For all standard SPE-cartridges/columns from 1 ml up to 15 ml For all standard Immunoaffinity columns (1 ml/3 ml) IAC-columns can be stored in the rack sealed with a tight cap, so buffer does not flow out. IAC remains fresh until you decide to use it For glass columns for max. dimensions 105 x 17,5 ID (length x diameter)

SPE Module Positive pressure for all steps in which liquids are used One rack for all kind of columns: reusable adapters allow an easy to change and mixed setup for all kinds of columns Columns can be moved to any place in the robotic area Standard three solvents, upgrade option up to six solvents

SPE Module SPE Module & handling of SPE cartridges/spe columns Software allows the transfer of nearly any manual method straight to an automation Method Development Move next step from the basic tools with drag & drop to second column The default button remains in the basic tools and can be choosen again The collected steps in the second column build the method Each button there can be individually changed and adopted by using the bars.

Software: SPE method SPE Module

SPE Module Application:determination of the Hydrocarbon Oil Index in water/soil according to EN ISO 9377-2 (H53 Method) For this very common routine application a special rack is used 36 samples can be handled in sequence If desired FREESTYLE system (Evaporation module necessary) can evaporate them right away down to 1.0 ml, sample can be transferred in GC-Vial: ready for analysis

EVAporation Module All necessary items are integrated (only chiller for solvent recovery additionally needed) Heart of the system: EVAporation chamber frequency controlle diaphragm pump (Vacuubrand) all sensoric items for detection of final volume heating system with two zones a) with water for fast EVAporation b) electrical heater for the extended cone for very sensitive evaporation EVAporation at its best!

EVAporation Module You can use these unique and unbeatable functions: automated EVAporation down to a final volume final volume can be choosen between 0.5 ml and 5.0 ml final volume can be set by software; no manual adjustment of the sensors! final volume can be set individually for each method = that means each sample in a sample list can have a different final volume EVAporation either by vacuum/heat or by nitrogen/heat (option) for very sensitive samples EVAporation at its best!

EVAporation Module More of these unique and unbeatable functions: solvent exchange (fluid/fluid or dryness/resolved) 360 C rinsing of the EVAporation chamber Concentrate can be fractionated Transfer of the concentrated sample with the robotic needle and not aspirated through a tube Option: the whole system can be charged with nitrogen Last but not least: automated calibration of the EVAporation chamber at any time for reliable and high precision final volume EVAporation at its best!

EVAporation module EVAporation method development; what you can use and modify: Sample aspiration Vacuum process Blow-down with nitrogen or compressed air Sample withdrawal from vacuum chamber Solvent exchange Fill-up and aliquotation Vacuum chamber rinsing EVAporation at its best!

Software: EVAporation method EVAporation Module EVAporation at its best!

GPC Module Double piston pump, esp. modified for low pressure applications (esp. with the appropriate pressure sensor) Flow rate from 0.1 ml to 50 ml/min GPC columns: - different dimensions and - different solvents for all official sample clean up methods worldwide

GPC Module GPC method development (1): 5 different possibilites of injection for all known applications: - from sample loop overfill (traditional clean up for pesticide analysis) - up to quantitative transfer by several injections from one glass (incl. 360 spray rinsing) - and collection of these runs in one flask (dioxin-analysis) Definition of forerun, main run (total, partial or sequential fractionation) and tailings Number and size of sample and collect vials Depth of needle immersion

GPC Module GPC method development (2): Column injection counter Flow rate (GPC module) Min. and max. pressure shut-off Sample aspiration speed (important for solvents like DCM) Column type and specification, respectively UV Detector data acquisition (yes/no)

GPC Module Software: GPC method screen; the whole adjustment of a GPC method can be done in this easy to handle screen.

FREESTYL - General Accessories Barcode Reader - Reading width 65 mm - With USB connection cable

FREESTYLE - General Accessories Liquid level switch for organic solvent (e.g. for waste bottle) Check of liquid level of waste bottle: Interruption of process, if bottle is empty / full (displayed in software)

FREESTYLE - Accessories for SPE and EVA Upgrade: 3 to 6 solvents: - Highly recommended for SPE applications Blow-down function for nitrogen and compressed air: - necessary for usage of nitrogen/air for evaporation - and drying of columns in SPE-function;

FREESTYLE Accessories for GPC module UV Fixed Wave Length Detector (254nm) for GPC column performance test; necessary software is integrated in the software package for FREESTYLE-systems

FREESTYLE - SUPERIORITY BY ADAPTATION Flexibility on highest level: FREESTYLE BASIC + GPC-Module + EVAporations-Module + SPE-Module In one sample list, there can be combined any method totally independent from each other: e.g.: 1. run: GPC 2. run: GPC+ EVA 3. run: GPC + EVA + SPE 4. run: EVA There is no hardware modification necessary at any time!

Where to find us Dorfen, Home of Bahnweg 41 84405 Dorfen Germany More about FREESTYLE-systems on www.freestyle-robotic.com or visit us at www.lctech.de!