BISG II. Bus Insulator Squirrel Guard. This new and improved isolation guard prevents animal-caused outages in electrical substation equipment.

Similar documents
Energy Division. Raychem Insulation Enhancement Systems

ATUM: General Purpose Thin Wall Tubing - with Adhesive (Black) Medium Wall: MWTM: General Purpose Medium Wall Tubing

MXSU - Selection table 3-core Kits / X-section

Terminations. Energy Division. Return to Contents

Section 7: Cable Glands & Duct Seals.

Energy Division. Raychem Raysulate Insulation Enhancement Systems

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

Energy Division Heat-shrinkable joints for halogen-free, flame-retardant and fire-resistand cables up to 1 kv

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series. Energy Division

Raychem Raysulate Insulation Enhancement Systems

Energy Division

RICS. Insulated adapter termination system for SF 6 -insulated switchgear up to 24 kv

Reliable solutions for electrified railway systems

Section 4: Medium Voltage Terminations - up to 42kV.

PolyGarde Metal-Oxide Surge Arresters

ENERGY PRODUCTS DIVISION. Raysulate. Insulation Enhancement System

WILDLIFE AND ASSET PROTECTION

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Connecting the World of Power ENERGY DIVISION

RELIABLE SOLUTIONS FOR ELECTRIFIED RAILWAY SYSTEMS

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

Energy Division. CSJT MV cold shrinkable joint for 3-core cables with resin encapsulation

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

XAGA 550/550-L. Aerial Splice Closure. 1. General Description. 2. Warnings. 3. Cautions

Heat-Shrinkable Termination System for Cables up to 36 kv

ENERGY PRODUCTS DIVISION. Polymeric Surge Arresters Reliable protection for power equipment upto 800kV

Energy Division. CSJR / CSJH Cold shrinkable straight joints for polymeric insulated cables up to 36 kv

Energy Division. DAH series (IEEE) Distribution metal oxide surge arrester

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

Section 8: Switchgear Connections (Straight & Elbows)

HVS S 15kV Class

RF one-step BNC/TNC connectors for coaxial cable termination

Gardian W51. Approvals

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA1 Series, (IEC)

WILDLIFE AND ASSET PROTECTION PRODUCTS

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

HVS S Splice Series

SPECIFICATION FOR GAPLESS METAL OXIDE DISTRIBUTION TYPE SURGE ARRESTERS WITH POLYMERIC HOUSING

GelCap SL. GelCap SL splice cover kits quickly and con-veniently insulate, seal, and protect stub splice connections up to 1000 volts.

Seal Kits for BUDI Enclosures

HV JUICE. RAYCHEM RAYSULATE Asset & Outage Protection. ECOLight Solar LED Streetlight Kit. June/July This Issue PAGE 4-5 ECO.

TECK-40 Series 1000V Class Splice for 4/C Armored Teck Power Cables

ENERGY /// RAYCHEM CABLE CLAMPS RAYCHEM CABLE CLAMPS. Quick Reference Guide

C A Heating Cable Gland Kit

Qualification Testing of Nuclear High Voltage Splice (NHVS) Title Pages: 49. Report Number: EDR-5391 Rev. 0 06/15/05. Approved by: Signature: Date:

Side Entry Bushing (SEB) High Temperature Cable Clamp Bushing Installation Instructions

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

JBM-100-LBTV2 Power Connection, Powered Splice, Dual Power Connection, or Splice with Junction Box

TE Connectivity's AMP NETCONNECT Cable Management

LOW VOLTAGE SPLICES & TAPS

RayClic Connection System

Tyco Thermal Controls provides complete heat tracing and speciality. wiring solutions for the industrial, commercial, and residential markets.

Commercial and Residential Self-Regulating Heating Products

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

Pin, Spool & Strain Insulators

Section 4: Medium Voltage Terminations - up to 42kV

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

Small Box for Cable Termination. 3.1 Preparation of box 3.3 Mounting of the box on the wall

Raychem Heating System

UV-SCE. Ultra-Violet light, Resistant TECHNICAL DATASHEET. Heat Shrink Identification Marker Sleeves

Contents. General information typical products summary 3. Low-voltage tubings 21. Cable end sealing kits, endcaps, and breakouts 35 1

TraceTek TT1000 Modular Sensing Cable

PolySwitch TS600 Overcurrent Protection Devices

Technical Paper. PPTC Circuit Protection for Power Management in Portable Communications/PDA Equipment

FOSC. Fiber Optic System Technology. Fiber Optic Splice Closures (FOSC-400)

C Electrical Connection Kit

RAYCHEM MEDIUM VOLTAGE

Raychem Link Boxes. Cable Services Limited. Powering the UK

Retro-DWS Other Methods Internal Heating Cable System for Sewer Pipe and Waste Drain Applications

TECHNOLOGY WEDGE PRESSURE HV JUICE PAGES 2 & 3. Pop-N-Work Pop-Up Tents PAGE 5. June/July This Issue.

Stainless Steel Cable Ties

154BC SPECIFICATIONS. Please refer to the 154N uncompensated and constant voltage datasheets for more information on different features of the 154.

COOPER POWER SERIES. Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions. Reclosers MN280020EN

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

DP86 Constant Voltage with Fitting

CIR CRUSH & IMPACT RESISTANT OIL & GAS CABLES

HTF3000LF PVH-3.3 TEMPERATURE AND HUMIDITY MODULE

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Retro-DWS Internal Heating Cable System for Non-Pressurized Sewer and Waste Drain Pipes

.025 Connector Series

ACCS-30. Multipoint commercial heat-tracing control system

Status Date Prepared Reviewed Endorsed Approved

Section 5: Medium Voltage Joints - up to 42kV

CIR CRUSH & IMPACT RESISTANT ARCTIC GRADE OIL & GAS CABLES

IEC Type Test Report Report No. EU1120-HR Type PDV 100 Polymer Arrester 10,000 A Line Discharge Class 1

CIR AG Power Cables. CIR AG Control Cable. CIR Type VFD Cable. CIR AG Ratings & Approvals. n UL Listed as Type TC-ER n UL Listed as TC-ER-HL (E123629)

Energy Division. Raychem Cable Accessories for Nuclear Environments

Industrial Strength Leak Detection

JGK-MS-2/3 Jacketed Concentric Neutral Cable Mid-Span Grounding Kit

Energy Division. Accessories for the Installation of Low Voltage & Medium Voltage heat-shrinkable products for the Electrical Power Industry

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

154BC SPECIFICATIONS FEATURES APPLICATIONS STANDARD RANGES

This document provides assistance with the selection of elements of the C5C copper pairs connection system. It includes the following sections:

FALCON SERIES 12 METAL CLAD

MAKING A LASTING MARK: Cable Identification Products

Tyco Electronics Solar Identification Labels

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Transcription:

BISG II Bus Insulator Squirrel Guard This new and improved isolation guard prevents animal-caused outages in electrical substation equipment. Reliable outage prevention: BISG II discs have been successfully eliminating outages from squirrels, raccoons, opossums, cats, and other animals in substations for years. The new BISG II guard has been designed to provide the same great protection with added features. Same high performance material: Superior high voltage outdoor materials are used in the new BSIG II guard design. The rugged, non-tracking, UV-resistant polymer ensures long-term performance even in the most extreme environmental conditions. Faster, easier installation: The BISG II guard allows easier hotstick installation by incorporating a threaded area in the guard. The integrated threads eliminate the need to hold a nut while installing the bolt assembly with a hotstick. The bolted design positively and tightly secures the device onto the insulator or bushing, eliminating loosening or drooping caused by wind, snow, ice, or animals. Expanded size range: The BISG II guard now fits insulator core diameters ranging from 1 (25mm) through 4.5 (115mm) from the factory. The new grill type design allows easy field modifications for even larger diameters (see your local Tyco Electronics representative for details). The BISG II guard can also have its outside diameter reduced by trimming along the grill ribs. This will allow the guard to fit in tight phase-to- phase insulator applications. Invisible appearance: The new BISG II design gives the same protection as the old guard without the noticeable profile. The invisible design allows easier visibility of switch blades and other equipment components through the guard.

Product Performance Product Test Power Arc (14.4 kv RMS Test Current: 10 ka RMS 10 cycles) Ice Flashover/ Contamination Impulse/ BIL AC Dry Withstand on disconnecting switch Wind Tunnel (70 MPH for 10 minutes) Requirement No evidence of burns or flames Insulator with BISG guard must demonstrate a flashover value within 90% of control Does not significantly alter electrical characteristic of insulator 15 kv minimum No dislodging of BISG guard from insulator location Key Material Properties Test Method Requirement Physical Tensile Strength ASTM D638 17 Mpa min. (2450 psi min.) Ultimate Elongation ASTM D638 25% min. Electrical Tracking and Erosion ASTM 2303 No tracking or erosion to top surface or flame Resistance Step Voltage Method Failure after: 1hr. @ 2.5kV, 2.75kV, 3.00kV (initiate @2.5kV) and 20 min. @3.25 kv Product Selection Product Type Insulator Range Standard Pack BISG-60/115-02-(S10) 1.0-4.5 (60mm-115mm) 10 Technical Reports EDR-5310 - Bus Insulator Squirrel Guard (BISG-60/115-02-FT) Mechanical/Electrical Evaluation Wedge technology products Electrical connectors Cable accessories Overhead conductor hardware Asset protection Surge arresters Insulators Fittings Associated tooling All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no cirumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for this product is set forth in our standard terms and conditions of sale. BISG is a trademark of Tyco Electronics Corporation. Argentina Phone: 54-11-4733 2277 Fax: 54-11-4733 2267 Australia Phone: 61-2-4390 1111 Fax: 61-2-4353 2497 Brazil Phone: 55-11-861 1311 Fax: 55-11-861 1862 Canada Phone: 1-905-475 6222 Fax: 1-905-470-4453 France Phone: 33-3-80583200 Fax: 33-3-80341015 Germany Phone: 49-89-6089-0 Fax: 49-89-6096345 Mexico Phone: 52-5-729 0405 Fax: 52-5-361-8545 Thailand Phone: 66-2-7394026-32 Fax: 66-2-3260563-64 200 0 Tyco Electronics Corporation Printed in USA 1308245 E131.8/00 Tyco Electronics Raychem Energy Division 8000 Purfoy Road Fuquay-Varina, NC 27526-9349 Phone: 1-800-327-6996 Fax: 1-800-527-8350 www.tycoelectronics.com

MVLC Medium Voltage Line Cover Convenient, reliable protection for bare conductors Outage prevention: The MVLC, Medium Voltage Line Cover, provides state-of-the-art insulation to help prevent electrical outages caused by trees or wildlife coming into contact with distribution lines. Cost-effective: The MVLC cover is designed to insulate existing bare lines without costly conductor replacement expenditures or additional line hardware. The MVLC cover may be applied selectively on problem spans. Live, consistent installation: Tyco Electronics has designed a special tool that ensures fast and reliable application of the MVLC cover. The tool allows application on energized lines. It attaches directly to the overhead conductor and remains stationary in a single location on each span. The tool may be manually or automatically operated, using a hand crank or with the aid of a power drill. The tool forms, closes, and feeds the MVLC cover along the conductor with speed and consistency. Wide use range: One size covers conductors from #2-397 kcmil (50-185 mm2). Higher performance product available: A mastic sealed version of the product is available for 25kV or higher performance at 15kV. High voltage material: The MVLC material formulation is based on 25+ years of field-proven experience with HV products in harsh environments. The high dielectric strength MVLC material is UV stable as well as tracking and erosion resistant. The MVLC cover is electronically cross-linked to create an extremely robust insulation system ensuring many years of reliable operation in the harshest environments.

Product Performance Test MVLC-18-A/U / MVLC-18-A/241 (sealed) AC withstand (dry) - 1 minute 15 kv min. / 25 kv min. AC withstand (wet) - 1 minute 15 kv min. / 25 kv min. AC long term withstand (dry) - 4 hours 8.6 kv min. / 14.4 kv min. 30 day thermal loading (8 hr @ 130 C; 16 hr off) No MVLC deformation Conductor ampacity 82-89% of bare conductor ampacity Key material properties Test method Requirement Physical Tensile Strength ASTM D638 10 MPa min., 1450 psi min. Ultimate Elongation ASTM D638 200% min. Abrasion Resistance 1000 cycles, 2068g 20% max. thickness loss Low Temperature Impact ASTM D746 No cracking at -20 C Electrical Dielectric Strength ASTM D149 217 kv/cm @ 1.27 mm min. 550V/mil @ 0.050" min. Tracking and Erosion ASTM D2303 No tracking or erosion Resistance Step Voltage Method to top surface or flame (Initiate @ 2.5 kv) failure after: 200 minutes Chemical Water Absorption ASTM D570 1% max after 336 hrs. at 23 C Resistance to bird guano Uric acid for 168 hrs @ 60 C -Tensile Strength 10 MPa min, 1450 psi min. -Ultimate Elongation 100% min. Resistance to Cable Grease 168 hrs @ 60 C -Tensile Strength 10 MPa min, 1450 psi min. -Ultimate Elongation 100% min. Thermal Accelerated Aging ASTM D2671 168 hours at (150±2) C -Tensile Strength 10 MPa min, 1450 psi min. -Ultimate Elongation 100% min. Thermal Endurance IEC 216 105 C min. Product Selection Product Size Conductor Size Weight MVLC-18 50-185 mm 2 (#2-397kcmil) 0.4kg/m (0.27 lbs/ft) Ordering Information Voltage Class Description UOM: m (ft) Spool Length Installation Tool 15 kv MVLC-18-A/U 75m (245 ft) MVLC-18-TOOL-01 25 kv (sealing mastic in receptacle) MVLC-18-A/241 75m (245 ft) MVLC-18-TOOL-02-241 Notes: Hand Tool Description: MVLC-HAND-TOOL-01 Hydraulic Drill Description: MVLC-HYDRAUL-DRILL Technical Reports EDR-5308 MVLC Electrical Testing EDR-5309 MVLC Material Qualification to PPS 3010/42 EDR-5316 Summary of Wind and Ice/Snow Load Testing of MVLC at EA Technology Wedge technology products Electrical connectors Cable accessories Overhead conductor hardware Asset protection Surge arresters Insulators Fittings Associated tooling All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no cirumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for this product is set forth in our standard terms and conditions of sale. Raychem and MVLC is a trademark of Tyco Electronics Corporation. Argentina Phone: 54-11-4733 2277 Fax: 54-11-4733 2267 Australia Phone: 61-2-4390 1111 Fax: 61-2-4353 2497 Brazil Phone: 55-11-861 1311 Fax: 55-11-861 1862 Canada Phone: 1-905-475 6222 Fax: 1-905-470-4453 France Phone: 33-3-80583200 Fax: 33-3-80341015 Germany Phone: 49-89-6089-0 Fax: 49-89-6096345 Mexico Phone: 52-5-729 0405 Fax: 52-5-361-8545 Thailand Phone: 66-2-7394026-32 Fax: 66-2-3260563-64 2000 Tyco Electronics Corporation Printed in USA 1308377 E113.9/00 Tyco Electronics Raychem Energy Division 8000 Purfoy Road Fuquay-Varina, NC 27526-9349 Phone: 1-800-327-6996 Fax: 1-800-527-8350 www.tycoelectronics.com

R OLIC Overhead line insulating channel Voltage classes 15/24 kv Conductor Ø 4 25 mm Product description OLIC is a clip-on insulating channel which provides flashover protection for overhead lines. Installation of OLIC prevents power outages from swinging conductors and intermittent contact with birds, animals and trees. OLIC is made from a track-resistant, crosslinked polymer of high dielectric strength. Installation is simple, requiring no heat and no tools, making OLIC ideal for retrofit applications. OLIC-O sections clip over the conductor and are held in place with UV stabilised plastic tie-wraps. OLIC-C sections clip over the conductor and are held in place with a removable and re-usable closure rail. Applications OLIC-O and OLIC-C are suitable for use on overhead line conductors with diameter from 4 mm to 25 mm. Both channels are available in 1 m and 3 m lengths. These can be cut easily to form a range of shapes and linked together to form long lengths. OLIC has passed test programmes set by Raychem and utilities for applications up to 15 kv (OLIC-O) and 24 kv (OLIC-C). Live-line working OLIC-O has been installed by one large utility using live-line working techniques. Features/benefits Clip-on, tool-free installation allows easy retrofit application Modular design permits re-enterable and re-usable applications High dielectric strength provides good protection against accidental line flashovers UV-resistance and weather resistance gives maintenance-free lifetime Raychem s high voltage test programme assures long term reliability Mechanically robust polymer design is lightweight and vandal-resistant

OLIC Overhead line insulating channel Key product specifications Test method Requirement Tensile strength (TS) ISO 37, ASTM D638 10 MPa min. Ultimate elongation (UE) ISO 37, ASTM D638 300% min. Dielectric strength IEC 243, ASTM D149 130 kv/cm min. @ 2 mm Comparative tracking index IEC 112, VDE 0303/1 KA 3c Low temperature ASTM D2671 No cracking flexibility Procedure C after 4 hrs @ -40 C Thermal endurance IEC 216, IEEE 1-1969 105 C min. Flammability ANSI C37.20/IEEE-27 No flame conveyance (60 sec max.) Smoke index NES 711 Less than 50 Weathering resistance ASTM G53 Less than 20% reduction in UE after 5000 hrs Resistance to bird guano Uric acid for 168 hrs @ 60 C No change in TS or UE Note: For further product specification information see Raychem PPS 3010/25. Product selection/ ordering information H H W W Ordering Dimension H Dimension W UOM: one piece of length description nom. min. (m) OLIC-O-1000 85 1.5 1.0 OLIC-O-3000 85 1.5 3.0 OLIC-C-1000 76 1.5 1.0 OLIC-C-3000 76 1.5 3.0 Note: Dimensions in mm unless otherwise stated. Installation instructions EPP 0627 5/96 and Material Safety Data Sheet available on request. Technical reports UVR 8193 Product qualification report for OLIC-C and OLIC-O Wedge technology products Electrical connectors Cable accessories Asset protection Surge arresters Insulators Electrical connectors Fittings Associated toolings All the above information, including illustrations is believed to be reliable. Users, however, should independently evaluate the suitability of each product for their application. Raychem makes no warranties as to the accuracy or completeness of the information and disclaims any liability regarding its use. Raychem s only obligations are those in the Standard Terms and Conditions of Sale for this product and in no case will Raychem be liable for any incidental, indirect, or consequential damages arising from the sales, resale, use or misuse of the product. Raychem Specifications are subject to change without notice. In addition, Raychem reserves the right to make changes in materials or processing, without notification to the Buyer, which do not affect compliance with any applicable specification. AMP, ELCON, ELO TOUCHSYSTEMS, HTS, MACOM, MADISON, NETCONNECT, RAYCHEM, SIMEL are trademarks of Tyco International Ltd. Members of the Tyco Electronics Corporation: Raychem EPP 0612 2/00 Tyco Electronics Raychem GmbH Energy Division Haidgraben 6 85521 Ottobrunn/Munich Germany Tel. (089) 6089-0 Fax (089) 609 63 45 Tyco Electronics Corporation Energy Division 8000 Purfoy Road Fuquay-Varina, NC 27526-9349, USA Tel. (800) 327-6996 Fax (800) 527-8350 Tyco Electronics Corporation Energy Division c/o AMP Singapore Pte Ltd No. 26 Ang Mo Kio Industrial Park 2 Singapore 569507 Tel. 65-4836012 Fax 65-4836031 www.tycoelectronics.com

Energy Division http://energy.tycoelectronics.com OLIT Overhead line insulation tape Voltage class 25 kv Max. conductor Ø 15 mm Product description OLIT tape is an adhesive-lined, heatshrinkable insulating tape which has been helically preformed to make it easy to install on overhead conductors. When the tape is wrapped around the conductor and shrunk down by the application of heat, the adhesive melts and amalgamates the overlapping layers of tape together thus producing, in effect, a wraparound tube. Although self-amalgamating, OLIT tape does not adhere to metal allowing easy removal for maintenance. Applications OLIT tape provides overhead line insulation for the prevention of faults caused by swinging conductors and intermittent contact with tree branches, birds and animals. OLIT tape provides flashover protection up to 17.5 kv or 25 kv if a second layer of tape is applied. Features/benefits Compatible with all other products in the Raychem MV insulation enhancement system Remains flexible at low temperatures High dielectric strength, weather and track-resistance ensure excellent electrical performance Continuous operating temperature up to 70 C Suitable for indoor and outdoor use Preformed into a spiral for easy installation on overhead conductors Easily and cleanly removed for maintenance Can be stored indefinitely at temperatures up to 50 C without loss of performance R

OLIT Overhead line insulation tape Key product specifications Test method Requirement Dielectric strength ASTM D149, IEC 243 130 kv/cm min. @ 2 mm Accelerated ageing ISO 188, ASTM D2671 168 hrs @ 120 C - Tensile strength 10 MPa min. - Ultimate elongation 300% min. Low temperature ASTM D2671 No cracking flexibility Procedure C after 4 hrs @ -40 C Volume resistivity ASTM D257, IEC 93 1 x 10 13 Ohm cm min. Smoke index NES 711 Less than 50 Acid gas generation Raychem PPS 3010 4.23 Less than 3% by weight Resistance to transformer oil VDE 0370 168 hrs @ 23 C - Tensile strength 10 MPa min. - Ultimate elongation 300% min. Note: For further product specification information see Raychem PPS 3010/33. The above information refers to backing material only, for adhesive requirements see PPS 3012/13. Ordering information Ordering Conductor Conductor size UOM: Conductor length description outside diameter roll of length insulated per piece (mm) (mm 2 ) (m) (m) OLIT-M 7 35 8 6.7 OLIT-M 9 50 8 6.2 OLIT-M 12 95 8 5.3 OLIT-M 15 150 8 4.4 Note: Maximum longitudinal change after free recovery: -30 %. Installation instructions EPP 0624 5/96 and Material Safety Data Sheet available on request. Technical reports OLIT tape is preformed into a spiral using HVBT high voltage insulation tape, please refer to the following test report: UVR 8023 Qualification report for HVBT All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, BOWTHORPE EMP, CROMPTON INSTRUMENTS, DORMAN SMITH, DULMISON, GURO, HELLSTERN, LA PRAIRIE, MORLYNN, RAYCHEM, and SIMEL are trademarks. Energy Division a pioneer in the development of economical solutions for the electrical power industry. Our product range includes: cable accessories, connectors & fittings, electrical equipment, instruments, lighting, insulators & insulation enhancement and surge arresters. Tyco Electronics EPP 0611 3/03 For more information and your country contact person, please visit us at: http://energy.tycoelectronics.com Tyco Electronics Raychem GmbH, Energy Division Finsinger Feld 1, 85521 Ottobrunn/Munich, Germany Phone: +49-89-6089-0, Fax: +49-89-6096345

R HVCE High Voltage Creepage Extenders A remedy for pollution flashovers of insulators

Raysulate High Voltage Creepage Extenders A remedy for pollution flashovers of insulators Raysulate Creepage Extenders increase the flashover performance of insulators by reducing the surface electric stress, reducing the leakage current and increasing the electric strength of the insulators. Installation of creepage extenders: Increases creepage length Improves insulator shape Adds high performance polymeric material to the creepage path Pollution flashovers Changing environments can cause increases in pollution levels which lead to excessive contamination of high voltage insulators. This may lead to unacceptably frequent flashovers if the creepage length and general design is inadequate. A replacement insulator having greater electric strength may be installed but the costs of this are high especially when a complete assembly, like a bushing, is involved. Common palliatives include live washing which reduces the contamination level, or surface treatments, either grease or rubbery coatings which smother the dirt or make the surface less wettable, or both. These palliatives have disadvantages in cost and effectiveness. The frequency of washing can be unacceptable and in some circumstances washing may promote flashover. Grease is a fire risk when it becomes choked with pollution and its removal is unpleasant and expensive. Coatings are difficult to apply and are also difficult to remove when eroded. The Raysulate Creepage Extender is a polymeric skirt internally coated with a specially formulated mastic. When heated the product shrinks around and bonds onto an existing insulator shed increasing the effective diameter and creepage distance of the insulator. Creepage extender design features needs only periodic inspection and will be effective many times longer than grease. Rugged Extenders are designed to be resistant to conventional spray washing techniques and will withstand all normal handling abuse and extreme weather conditions. Proven materials The extenders are fabricated using Raychem s unique high voltage materials technology which has over 25 years of high voltage field experience in adverse environments all over the world on cable terminations, insulators and bushings. Creepage extenders on 66 kv insulators Creepage extenders on 24 kv bushings Creepage extenders on 66 kv substation in a heavily polluted marine environment adjacent to a steelworks Increases creepage length This increases electric strength by reducing leakage current and surface stress. Improves insulator shape The increased shed diameter improves strike distance and improves heavy wetting performance by creating an umbrella effect. Bonds to insulator surface The extender adhesive has been specially formulated to strongly bond to the existing porcelain or glass skirt. Thus, the assembly

Simple to install Just degrease the insulator and shrink the extender with a gas torch or hot air gun. Raychem can provide installation training. Creepage extender testing Data from IEC 815 shows that at a fixed voltage, our typically recommanded extension of 20% to the creepage will more than double the pollution level needed to cause flashover (see figure 1). Pollution flashover tests (to IEC 507) on insulators fitted with creepage extenders show that, for a fixed salt concentration, flashover values increase in proportion to the increased creepage distance. Figure 2 shows typical results on a 66 kv post insulator. In practice, these results show that the addition of creepage extenders can effectively change an insulator which has marginal performance in the prevailing conditions to one which has a large margin of safety against pollution flashover. Tests have been done on a variety of insulator sizes and shapes including suspension and post insulators covering a range of diameters. The results consistently show an improvement for all insulators. Where the insulators are of a particularly bad design (eg. close packed sheds of identical size) the improvement in shape adds to the effect of the longer creepage path to give exceptionally good results. Raychem report UVR 8139 summarizes these results. Materials properties Raychem s high voltage insulating materials have undergone long-term field and laboratory testing to determine their suitability for use in the high voltage environment. The use of the material (eg. in several million Raychem high voltage cable terminations installed worldwide) bears out the excellent testing results and has helped establish an outstanding service record in the most severe environmental conditions. Tracking and erosion resistance testing On the ASTM D2303 inclined planetest, the material is non-tracking under all conditions including addition of 1% sugar contaminant. Resistance to weathering Raychem s on-going material tests measure the retention of elongation as a method of monitoring ageing. Retention of elongation is a good measure of resistance to cracking by UV light. The material properties measured for the Raychem high voltage material demonstrate its suitability for use outdoors even in extreme desert conditions where UV light concentrations are severe. See report No. EDR 5018. Effect of creepage distance on salt fog concentration withstand value Figure 1 Minimum salt fog concentration (Kg/m 3 ) General properties Test method Typical data* Density ISO/R1183 Method A 1.2 g/cm 3 Tensile strength ISO 37 10 N/mm 2 Ultimate elongation ISO 37 400% Low temperature flexibility 4 hours at -40 C ASTM D2671 Procedure C no cracking Thermal endurance IEC 216 120 C Electric strength IEC 243 140 kv/cm Dielectric constant IEC 250 3 Volume resistivity IEC 93 1 x 10 14 Ω cm Additional properties Further details are given in Raychem Specification PPS 3011 Note: 320 160 80 40 20 10 5 Four extenders per 1000 mm creepage 80 Kg/m 3 salt fog Two extenders per 1000 mm creepage 32 Kg/m 3 salt fog No extenders. Insulator design = 20 mm/kv 14 Kg/m 3 salt fog 20 25 30 35 40 Specific creepage distance mm/phase to phase kv Flashover voltage versus number of extenders on 66 kv post insulator Figure 2 kv at flashover IEC 507, 80 Kg/m 3 salt fog 60 50 45 40 35 Vertically mounted Horizontally mounted 30 1500 Control 1700 Plus two extenders 1900 Plus four extenders Total creepage (mm) *Typical qualification test data. Minimum requirements are given in Raychem specification PPS 3011/1

Selection table Creepage extenders are usually fitted to insulators with normal or alternating shed profiles (as defined by IEC 815). This IEC specification also categorises insulators into one of four pollution classes. We recommend moving from one class to a higher pollution class for improving flashover performance as shown in the table. Creepage extenders can also be used to produce extensions on insulators designed for highly polluted areas (with > 31 mm/kv as designed). For specific recommendation, contact your local Raychem representative. They can advise on fitting creepage extenders to non-standard shed profiles and pollution class insulators. Ordering information 1 XX denotes colour (01 = red) 2 On insulators close to the maximum diameter in the application range, the creepage extender will droop when installed. For further information, see the qualification report UVR 8139. 3 The ordering unit of measure is pieces. Non standard sizes In many cases, creepage extenders for other sizes are available or can be designed. Contact your local Raychem representative for details. Ordering example To order a red creepage extender for a shed of diameter 110 mm, simply order: 1 piece of HVCE 120/100-01 d Class I (ESDD* 0.03 to 0.06 mg/cm 2 ) Light Creepage = 16 mm/kv system Class II (ESDD 0.1 to 0.2 mg/cm 2 ) Medium Creepage = 20 mm/kv system Class III (ESDD 0.3 to 0.6 mg/cm 2 ) Heavy Creepage = 25 mm/kv system Class IV (ESDD > 0.6 mg/cm 2 ) Very heavy Creepage = 31 mm/kv system *ESDD equivalent salt deposit density Insulator Voltage Class No. of Creepage Extenders to move to II III IV I 1 2 ** 12/17.5 II 1 2 III 1 I 1 2 ** 24 II 1 3 III 2 I 2 3 ** 36 II 2 4 III 2 I 3 ** ** 72 II 4 ** III 4 I 5 ** ** 145 II 7 ** III 8 **Recommend new insulator fitted Dimensions in mm (inches) Application range Size Min. internal dia. Max. shed dia. Min. shed dia. Nominal creepage of the extender of insulator of insulator extension per (as supplied) (d) (d) extender HVCE-100/ 80-01 115 (4.5) 100 (4.0) 80 (3.2) 100 (4.0) HVCE-120/100-01 135 (5.3) 120 (4.7) 100 (4.0) 100 (4.0) HVCE-140/120-01 155 (6.1) 140 (5.5) 120 (4.7) 100 (4.0) HVCE-160/140-01 180 (7.1) 160 (6.3) 140 (5.5) 100 (4.0) HVCE-183/161-01 205 (8.1) 183 (7.2) 161 (6.3) 100 (4.0) HVCE-205/184-01 230 (9.0) 205 (8.1) 184 (7.2) 100 (4.0) HVCE-226/206-11 241 (9.5) 226 (8.9) 206 (8.1) 100 (4.0) HVCE-247/227-11 262 (10.3) 247 (9.7) 227 (8.9) 100 (4.0) HVCE-268/248-11 283 (11.1) 268 (10.5) 248 (9.8) 100 (4.0) HVCE-289/269-11 304 (12.0) 289 (11.4) 269 (10.6) 100 (4.0) HVCE-310/290-11 325 (12.8) 310 (12.2) 290 (11.4) 100 (4.0) HVCE-331/311-11 346 (13.6) 331 (13.0) 311 (12.2) 100 (4.0) HVCE-352/332-11 367 (14.4) 352 (13.8) 332 (13.1) 100 (4.0) HVCE-373/353-11 388 (15.3) 373 (14.7) 353 (13.9) 100 (4.0) HVCE-394/374-11 409 (16.1) 394 (15.5) 374 (14.7) 100 (4.0) All of the above information, including drawings, illustrations and graphic designs, reflects our present understanding and is to the best of our knowledge and belief correct and reliable. Users, however, should independently evaluate the suitability of each product for the desired application. Under no circumstances does this constitute an assurance of any particular quality or performance. Such an assurance is only provided in the context of our product specifications or explicit contractual arrangements. Our liability for these products is set forth in our standard terms and conditions of sale. ALR, AMP, AXICOM, B&H, Bowthorpe EMP, Critchley, Dorman Smith, Dulmison, Guro, Hellstern, La Prairie, Morlynn, Raychem, and SIMEL are trademarks. Argentina Phone: ++54-11-4733 2277 Fax: ++54-11-4733 2267 Australia Phone: ++61-2-4390 1111 Fax: ++61-2-4353 2497 Brazil Phone: ++55-11-3611 1862 Fax: ++55-11-3611 2457 Canada Phone: ++1-905-475 6222 Fax: ++1-905-470-4453 France Phone: ++33-3-80583200 Fax: ++33-3-80341015 Mexico Phone: ++52-5-729 0405 Fax: ++52-5-361-8545 Thailand Phone: ++66-2-7394026-32 Fax: ++66-2-3260563-64 United States of America Phone: ++1-800-327-6996 Fax: ++1-800-527-8350 United Kingdom Phone: ++44-1772-325400 Fax: ++44-1772-726276 Tyco Electronics Raychem GmbH Energy Division Haidgraben 6, 85521 Ottobrunn/Munich, Germany Phone: ++49-89-6089-0, Fax: ++49-89-6096345 http://energy.tycoelectronics.com Tyco Electronics EPP 0355 2/02