Installation instruction

Similar documents
Installation instruction

Operation instructions

Sauna Heater. Installation and Manual

Varde Shape. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

Varde Aura. Smoke Control Kit. Additional Installation and User Instructions for use in Smoke Control Areas

SAUNA HEATER INSTALLATION AND OPERATING MANUAL

Installation and Operating Instructions

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Hybrid 20

Esse B MODEL Roomheater with boiler WOOD BURNING ONLY MODEL

Installation of a Brunner fireplace. General Indications

USER S MANUAL, MAINTENANCE MANUAL INSTALLATION INSTRUCTIONS

Relaxed Premium M Relaxed Premium M ENG

INSTALLATION, OPERATION AND MAINTENANCE. Ariterm Vedo

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

Technical Specifications Panoramic FX1

Installation and Operating Manual

Bergen PRPMXXXX. Smoke Control Kit Additional Installation and User Instructions for use in Smoke Control Areas

Fireplace inserts. Model SK1000, SK2000. Installation instructions Care and firing instructions

The Morsø S100 Series

INSTALLATION AND OPERATING INSTRUCTIONS. Ariterm 60+

INSTALLATION AND OPERATION MANUAL

Installation Instructions. Rayburn 300W Wood Burning Cooker

Installation and user manual CLOSED WOOD FIRES DON T COMPROMISE.

Installation and service must be provided by a qualified installer, service agency or the gas supplier.

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Duet Premium M Duet Premium M ENG

Installation & Operating Instructions

Operating and installation instructions for Fire Lotus H586

Riva F40 Cube. Multi-Fuel Free Standing Stove. Installation Instructions. Models: RVF40C. For use in Great Britain and Eire IMPORTANT

Installation and Operating Instructions

TECHNICAL MANUAL. Multifuel Stove Model EW1MF. To be retained by the user for future reference. Serial Number. Document EW1MF 0209

Serenity Range. Inset and freestanding Stoves. Warming your world. Multifuel Stoves for the home DESIGNED & MANUFACTERED IN THE UK

Serenity Range. Inset and freestanding Stoves. Warming your world. Multifuel Stoves for the home DESIGNED & MANUFACTERED IN THE UK

Installation / User Manual

Fyn Installation guide

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

MOS GB INSTALLATION AND MAINTENANCE INSTRUCTIONS VEDEX 1000 VEDEX 1000 M10527 LEK

Contents. Visual page Technology page Features page Ulys page Carina page Stella III page V Series page 35-38

FIREPLACE SIZES FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VACINITY OF THIS OR ANY OTHER APPLIANCE.

version 1.2 Made by NARVI Oy Finland Aito 16 / 20 / 24 / 16 VS / 20 VS / 24 VS Installation, user and maintenance instructions

Leading European manufacturer of fireplace stoves and fireplace inserts

Masterflamme Convection Wood Stoves Perfect combustion with unique design

Installation & Manual. Model T-25

Cassette inserts and fireplace doors

TECHNICAL MANUAL. The Buxton. Multifuel Stove Model BX1MF. To be retained by the user for future reference

LISEO Insert. European Standard Certification UNE EN inserts. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

Fyn Installation guide

INSTALLATION AND OPERATION GUIDE FOR HARGROVE GAS LOGS

Riva Studio Duplex. Inset Convector Cassette. Instructions for Use, Installation & Servicing

Clear Installation guide

Maintenance 50 Serie CAUTION. Before resetting your electronic card that displays an error code. OVERHEAT MESSAGE

Wet stove installation guide

The stove pictured on the cover is the Evo 30 (see page 9)

Figure 1 Solid fuel cook-stove KMŠ 70 and KVŠ 90H

Quadro 1, 2 & S-31A Insert

GENERAL RULES. Ensure that the installation of your product conforms to all the indications given below. English CHIMNEY STACK

LISEO STOVES. European Standard Certification UNE EN stoves. LISEO s.r.o. Folknářská 1246/21 Děčín 2 Nové Město

STATEMENT OF SOLID FUEL APPLIANCE PERFORMANCE

Duet XL /0929. Installation guide

^ STUV 21: MODEL SPECIFICATIONS

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

ASX7-5-IOM-3 J

INSTRUCTIONS FOR INSTALLATION, SETTING AND USE

ASX7-4-IOM-6 J

INSTALLATION OPERATION AND SERVICE MANUAL

1. Contents Principle General information Parts list Assembly Technical drawing... 18

The Pevex Range. Inset, freestanding & convector stoves. Multifuel Stoves for the home IN THE UK

INSTALLATION INSTRUCTIONS

JETMASTER INSET STOVE MK2 16i, 18i, 50i, 60i, 70i, 60i Low, 70i Low

Solution Installation guide

Duet Premium L Duet Premium L ENG

Studio. Built-In Convector. Instructions for Use, Installation & Servicing. For use in AU (Australia)

Rocket heater GAMERA

Masterflamme Convection Wood Stove

WOOD STOVE SERVICE MANUAL

Corn Flame Energy Corn Stove Model 3000

Stockton 7 & 8 Inset Convector Stove

Exmoor/Exe/Devon. Freestanding Stove. Instructions for fitting Smoke Control Kit. For use in GB & IE (Great Britain & Republic of Ireland).

INSTRUCTIONS MANUAL FOR USE AND MAINTENANCE

TOYOTOMI U.S.A., INC. P.O. Box 176, Brookfield, CT

Quality Through Integrity

Website:

The Victorian High Country Home of Euro Fireplaces

Easyfire Standalone biomass pellet boiler

tççç= ÜÉ~íáåÖ çéíáçåë

Quality Through Integrity

INSTALLATION AND SERVICE INSTRUCTIONS. The biggest Czech producer of fi replace inserts. Accurate and precise design of details

Studio. Inset Convector Cassette. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

MODEL 466 Radiant / Convector Gas Fire Black Beauty

(manual control) (ezi-slide control) INSET COAL EFFECT GAS CONVECTOR FIRE V1/100/B INSTALLATION & USER INSTRUCTIONS

The Discovery Series Exploring The Australian Indoors. Woodheating

Furthermore, the fire flaming in your FIREPLACE hearth creates an intimate atmosphere for your family and friends.

Before selecting your stove, it is very important that you clearly identify what your needs are:

Studio. Freestanding Range. Instructions for Use, Installation & Servicing. For use in GB & IE (Great Britain & Republic of Ireland).

TECHNICAL MANUAL. Multifuel Stove Model MV1MF. To be retained by the user for future reference

INSTALLATION AND SERVICE MANUAL

Woodburning Zero clearance

INSTALLATION INSTRUCTIONS

SUPERIOR CHOICE. Heating Solutions

Transcription:

Installation instruction Ci50 www.contura.eu

82 CERTIFICATE Declaration of performance according to Regulation (EU) 305/2011 No. Ci50-CPR-150821-SE-2 PRODUCT Product type Type designation Manufacturing number Intended area of use Fuel Insert lit with solid biofuels Contura i50 See rating plate on the insert Heating of rooms in residential buildings Wood MANUFACTURER Name NIBE AB / Contura Address Box 134, Skulptörvägen 10 SE-285 23 Markaryd, Sweden CHECKS According to AVCP System 3 European standard EN 13229:2001/AC:2006, EN-13229:2001/A2:2004/AC:2007 Test institute Rein-Ruhr Feuerstätten Prüfstelle, NB 1625, has checked declared performance and issued test report no. RRF-29 15 4067 DECLARED PERFORMANCE Essential characteristics Performance Harmonised technical specification Reaction to fire A1 WT Minimum distance to combustible material Rear: 150 mm Side: 700 mm Follow the given conditions in the installation instructions. Risk of falling embers Pass Emissions from combustion CO 0,08% NOx 96 mg/m 3 Surface temperatures Cleaning options Mechanical durability Emissions of hazardous substances Nominal output Efficiency 80% Flue gas temperature in connector at nominal 334 C output OGC 69 mg/m 3 PM 23 mg/m 3 Pass Pass Pass Pass 8,0 kw EN 13229:2001/AC:2006, EN-13229:2001/A2:2004/AC:2007 The undersigned is responsible for the manufacture and conformity with the declared performance. Niklas Gunnarsson, Business area manager NIBE STOVES Markaryd, August 21, 2015

CONTENTS 83 A warm welcome to Contura. A warm welcome to the Contura family. We hope you will get a great deal of pleasure from your new insert. As a new owner of a Contura insert, you have secured a product with timeless design and long service life. Contura also has a combustion process that is both environmentally friendly and efficient, for the best heat production. Read through these installation instructions carefully before installation. Read how to best light your stove in the lighting instructions. List of Contents Technical specifications 84 Important dimensions 85 Prior to installation 85 For installation in the UK and in smoke control areas 88 Installation 94 Chimney 95 Recessing the insert 97 Recess example 98 NOTE: Report the installation of a stove to your local authority. The owner of the house is personally responsible for ensuring compliance with the mandatory safety requirements and must have the installation approved by a qualified inspector. Your local chimney sweep must also be informed about the installation as this will affect the routines for regular chimney-sweeping services. WARNING! The insert becomes very hot During operation, certain surfaces of the insert become very hot and can cause burn injuries if touched. Also, take heed of the strong heat radiated through the door glass. Placing flammable material closer than the safe distance indicated may cause a fire. Smoulder combustion can cause quick gas ignition with the risk of damage to property and personal injury.

84 FACTS Technical specifications Model i50 Output 6-11 kw Nominal output 8 kw Efficiency 80% Weight (kg) 160 (with Thermotte) 130 (without Thermotte) Width (mm) 765 Depth (mm) 485 Height (mm) 1465 Connector diameter Ø150 mm ext. General This manual contains instructions about how to assemble and install the Contura i50. To ensure the function and safety of the insert, we recommend that installation is carried out by an authorised technician. Our Contura agents can recommend a suitable installer; information regarding our agents is available at www.contura.eu Instructions for lighting are also supplied with the insert. Read them carefully and keep them safe for future use. Structural support Check that floor joists have the sufficient load capacity for the insert, chimney and construction parts that are used when recessing. Floor plate If the floor under the stove is flammable, it must be protected by a non-flammable material e.g. natural stone, concrete or at least 0.7 mm thick metal. The floor in front of the hearth opening must be protected against any falling embers using non-flammable material that covers an area at least 300 mm all around. A toughened glass hearth plate is available as an accessory. Application to local authority Before installing a stove or erecting a chimney, it is necessary for you to make an application for permission to your local authority. Ask your local authority for advice regarding regulations and the application. Heat Strålningsplåt deflector Diffuser Diffusor Counter Motvikt weight Smoke Rökhylla shelf Hearth cladding Eldstadsbeklädnad Grate Roster Damper Spjäll Ash-pan Asklåda Adjustable Justerbara feet fötter Type Typskylt plate Connector Anslutningsstos Bottom Bottenisolering insulation

IMPORTANT DIMENSIONS / PRIOR TO INSTALLATION 85 Important dimensions C i50 485 765 190 420 1465 670 390 1220 970 95 270 345 420 140 240 35±10 Justerbar Adjustable fot foot Air Inlet Tilluftsstos Ø Ø 70 260 Prior to installation Opening sidelights

86 PRIOR TO INSTALLATION Remove the loose parts from the firebox. The insert is secured to the pallet by the two rails, remove the screws and remove the angle brackets. Reinstall the screws on the legs before moving the insert from the pallet. 3 mm 10 mm

PRIOR TO INSTALLATION 87! Check wire routing and remove the transport locking devices! 10 mm

88 PRIOR TO INSTALLATION Function check Perform a function check on the Insert as follows: Use the adjustable feet to level the insert. Check that the door can be opened and closed. Check that the damper knob can be moved back and forth to the max and min marks.! The door runners are lubricated at the factory, with special grease that can withstand high temperatures. This type of grease is usually difficult to find on the market and we recommend contacting a Contura dealer to order this special grease when lubricating the runners. For installation in the UK and in smoke control areas Mandatory for smoke control areas The Contura i50 and i51, 8 kw woodburning stoves has been recommended as suitable for use in smoke control areas. This when burning wood logs and operated in accordance with these instructions and when fitted with a permanent stop to prevent closure of primary air control beyond the 52 mm² open position, secondary air control beyond the 500 mm² open position and the tertiary air control beyond the 215 mm² open position. The permanent stop must be installed if the appliance is to be used in a smoke control area, this stop must not be removed in smoke control areas, otherwise an offence will be committed if the appliance is used without the permanent stop in place.

10 GB PRIOR TO INSTALLATION 89 Installing heat defl ector PH2 10 VANADIUM No. 7 CHROME 10 mm

90 PRIOR TO INSTALLATION Installing the fi rebox cladding 1 2 3 4

PRIOR TO INSTALLATION 91 5 6 7 8

92 PRIOR TO INSTALLATION 9 10 11

OPTION 93 Installing Powerstone Option! Install the Powerstone blocks as illustrated. With combustion air hose as option now install according to separate instructions. With recessing frame as option now install according to separate instructions.

94 INSTALLATION Installation Ensure that the installation meets national and regional regulations. The installation must be approved by an authorized inspection body. Supply of combustion air must be provided. Combustion air can be provided directly via a duct from outside, or indirectly via a vent in the outer wall of the room where the stove is placed. The amount of combustion air that is used for combustion is approx. 25 m 3 /h.! Some installation alternatives are shown below. The air duct connection on the stove has an external diameter of Ø mm. Turn the connector to ensure an air supply! In hot areas, the duct should be insulated with 30 mm mineral wool covered with a moisture inhibitor (aluminium tape). It is important that the lead-in, between the pipe and the wall (or floor), is sealed using jointing compound. A 1 m length of condensation-insulated ducting for combustion air is available as an accessory. HK HK HK HK

235 GB CHIMNEY / SELF-CLOSING DOOR 95 Chimney The insert is approved and must be connected to a chimney dimensioned for at least 350 C, the external connection diameter is Ø150 mm. The insert requires a draft in the chimney of at least 12 Pa. The draft is affected both by the length and area of the chimney, and by how well sealed it is. Carefully check that the chimney is sealed and that there is no leakage around soot hatches and flue connections. Note that a flue with sharp bends and horizontal routing reduces the draught in the chimney. The maximum horizontal flue is 1 m, on the condition that the vertical flue length is at least 5 m. It must be possible to sweep the full length of the flue and the soot hatches must be easily accessible. If two fireplaces are connected to the same chimney flue, the stove must be equipped with self-closing door. Rearward connection For the rearward connection it is recommended to use a 45 +45 angle with soot hatch and with the centre 235 mm above the connector. It is important that sweeping can be carried out through convection grates or a hatch in the surround. Self-closing door (ONLY APPLIES TO GERMANY) The insert can be supplied with a self-closing door. Fold out the three tabs on the counterweight pack. Lift out the two weights that are positioned slightly higher up. Remove the two side panels and install the two panels enclosed instead, see images on the next page. Check the function, if necessary further weight can be removed. Fold in the three tabs again to keep the counterweights in place. 1 2

96 SELF-CLOSING DOOR 3 B A 4 B A 5

RECESSING THE INSERT 97 Recessing the insert When recessing the insert, adjacent walls that are not classed as fire walls or are considered unsuitable for heat loads must be protected by non-combustible material according to the specification below. All joints on the non-combustible material must be sealed using the manufacture s recommended method. The area between the insert and the recess must be ventilated according to the specification/dimension diagrams on page 99. When connecting a steel flue, please refer to the particular manufacturer's installation instructions. Observe the safety distance to combustible material required by the steel flue Heat radiation from the door is strong and because of this combustible material must not be placed closer than 1.5 m in front of the door. When recessing, building material must not be in direct contact with the insert due to the thermal expansion of the insert. Note that building regulations apply regarding the area below and in front of the insert, see section Hearth plate. Material requirements The building material must not be combustible. The thermal conductivity coefficient λ must be a maximum of 0.14 W/mK. The thickness of the building material must always be at least mm. In cases where the building material s insulation properties are given as a U-Value, this must be a maximum of 1.4 W/ m²k. List of suitable materials: Aerated concrete λ =0.12-0.14 Vermiculite λ =0.12-0.14 Calcium silicate λ = 0.09 Sealing The recess must not go all the way up to the ceiling, leave an air gap of at least 20 mm closest to the ceiling. The recess must be sealed off above the convection exhaust. The seal must be mm above the convection exhaust s upper edge and must be made of mm non-flammable material according to the material requirements above. Use heat-resistant silicone, for example, between the seal and chimney. Convection air The convection air ventilates the surround, cools the insert and transports the hot air out into the room. The effective cross section area on the air intake and exhaust must not be less than the stated values. The air intake must be positioned somewhere between floor level and the bottom of the insert, at the front or on the sides of the recess. The vent must be positioned above the insert s highest point at the front or to the sides of the recess. If the air intake respectively the vent is positioned on the sides, the areas for the left respectively right sides must be the same size to ensure that the insert is evenly cooled. The distance from the exhausts on the sides to the combustible wall behind must be mm. Observe the minimum distance up to the ceiling (see diagram on page 99). Convection air in: 600 cm² Convection air out: 600 cm² If the convection outlets are directed upwards the following applies - the recess must be free-standing or placed against a non-combustible wall. - the distance from the air outlet to combustible roof must be at least 750 mm.! Service Access to the damper and counterweight must be ensured via doors or ventilation grilles in the surround.

98 RECESSING THE INSERT 550 max Area ut min. 600 cm 2 Recess example! The dimensions are the minimum dimensions, unless otherwise stated. Wall of combustible material Area in min. 600 cm 2 20 20 Wall of non-combustible material that is not in contact with combustible material and therefore has no minimum thickness requirement. (I 20 min 2300) Chimney breast Wall of non-combustible material, made of mm aerated concrete in the recess example. * 175 50 500 (I 10 min 2) 700 275 * 50 * The distance from the exhausts on the sides to the combustible wall behind must be mm. Final inspection of the installation It is extremely important that the installation is inspected by an authorised inspection body before the stove is used. Also read the "Lighting instructions" before lighting for the first time.

RECESSING THE INSERT 99 Sealing Avtätning 340 50 Max 20 550 Area Area out ut 600 600 cm cm 2 2 Area Area in 600 in 600 cm 2 cm 2 750 50 Max Max 550 Area Area out ut 600 600 cm cm 2 2 Area Area in 600 in 600 cm 2 cm 2 550 Area Area out ut 600 600 cm cm 2 2 Area Area out ut 600 600 cm cm 2 2 Area Area in 600 in 600 cm 2 cm 2 Area Area in 600 in 600 cm 2 cm 2 50 50 Can be excluded if the chimney breast behind is approved and meets full safety requirements according to the authorized inspection body.! Always observe the safety distances to combustible material required by a steel flue! The dimensions are the minimum dimensions, unless otherwise stated.

NIBE AB Box 134 285 23 Markaryd Sweden www.contura.eu 811267 IAV SE-EX Ci50-6 2017-05-17 Contura reserves the right to change dimensions and procedures described in these instructions at any time without special notice. The current edition can be downloaded from www.contura.eu