Einbauanweisung Installation Instructions Instructions de montage. Wasserheizgeräte Water Heaters Chauffages à eau.

Similar documents
NiteCool TCC-100/RCC-100

Luftheizgeräte Air heaters Luchtverwarmingsapparaten. Einbauanweisung Installation Instructions Montagehandleiding.

Air Top 2000 ST. Luftheizgeräte Air Heaters Luchtverwarmingsapparaten. Einbauanweisung Installation Instructions Montagehandleiding

Thermo 90 Thermo 90-ADR Thermo 90 S Thermo 90 S-ADR

Wasserheizgerät Water heater Appareil de chauffage. Einbauanweisung Installation Instructions Notice de montage. Thermo Pro 90

Air Top 2000 ST. Luftheizgeräte Air Heaters Luchtverwarmingsapparaten. Einbauanweisung Installation Instructions Montagehandleiding

Thermo 90 Thermo 90-ADR Thermo 90 S Thermo 90 S-ADR

Thermo Pro 50 Eco 24 Volt Diesel

Bootsheizsysteme Luftheizgeräte Boat heating systems Air heaters Scheepsverwarmingssystemen Luchtverwarmingsapparaten

Air Top 2000 ST B (Gasoline) Air Top 2000 ST D (Diesel)

DUAL TOP RHA 100 / 101 / 102

Air Top 3500 Air Top 5000

Thermo 50. Workshop Manual. Water heaters. Type Thermo 50 (Diesel/PME) 09/1999

Dual Top RHA-100 Dual Top RHA-101/102

Installation Instructions

Air Top Evo 3900/5500 B (Gasoline) Air Top Evo 3900/5500 D (Diesel)

Operating instructions. Air heater Air Top Evo 40 Air Top Evo 55 for motor homes

Air Top Evo 40 / 55. Air Heater. Installation/Operation Manual

HYDRONIC II Technical description, installation, operating and maintenance instructions.

Air Top 3500 Air Top 5000

Installation manual. 2kW Calaer air heater 4kW Calaer air heater

A WORLD OF COMFORT. The troubleshooting and repair instructions are only valid. Heaters for petrol B 5 S 12 V

The troubleshooting and repair instructions are only valid. Heaters for petrol B 4 S 12 V B 5 S 12 V

List of Contents. 1.5 Legal Provisions for Installation Corrections and Improvements Combustion Air Fan Assembly...

List of Contents. 1.1 Scope and Purpose

WATER-HEATER FOR VEHICLES

AIRTRONIC L Technical description, installation, operation and maintenance instructions.

Operating Instructions Thermo 50. Introduction. Maintenance and Safety Instructions

AIRTRONIC L Technical description, installation, operation and maintenance instructions.

BlueHeat AirTop 2000 Heater

SNUGGER SNUGGER AIR HEATER AIR SNUGGER USA Technical description. Installation instructions. Operating instructions

Wasserheizgerät Water heater 水暖型加热器. Einbauanweisung Installation Instructions 安装指导. Thermo Top Z/E/C. Thermo Top C - D (Diesel) (diesel) ( 柴油 )

SNUGGER CANADA Snugger Heaters Unit B-1465 Kebet Way Port Coquitlam, BC V3C 6L

Installation and operating instructions. Central Heating System kw. Webasto Product Intern national The Netherlands

AIR-HEATER FOR VEHICLES

Air heater 8 L Technical description, installation, operation and maintenance instructions.

BlueHeat Coolant Heater

Repair instructions A WORLD OF COMFORT. Spare parts list. The repair instructions are valid for the following

Coolant Heater Thermo Top (TTC) Heavy-duty Operating Instructions Installation Instructions

HYDRONIC L Technical description, installation, operation and maintenance instructions.

Troubleshooting and Repair Instructions. Eberspächer. The Troubleshooting and Repair Instructions are applicable to the following unit versions

Air Heater 5 L. Visit for more technical information & downloads. Eberspächer

SECTION AUXILIARY HEATER

Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly carbon monoxide leading to serious

AIRTRONIC / AIRTRONIC M Technical description, installation, operation and maintenance instructions.

Repair Shop Manual. Air Heaters. Air Top 2000 Diagnosis. Air Top Type AT 2000 B (Fuel) Type AT 2000 D (Diesel)

Thermo 50 Coolant Heater. HMMWV 6.2 and 6.5 Liter Diesel. Table of Contents. Foreword

TECHNICAL DESCRIPTION, INSTALLATION, OPERATING, TROUBLESHOOTING, REPAIR AND MAINTENANCE INSTRUCTIONS - HYDRONIC II 5E, HYDRONIC II.

Coolant Heater. Thermo Installation Instructions for use with The Detroit Diesel Series 4000 Engine

AIRTRONIC * AIRTRONIC D4. Operating Instructions and Service Book

5 On/Off button 6 Function selector switch 7 Symbol - Eco function 8 Symbol - Standard heating function

Thermo H 160 Thermo H 230 Thermo H 300 Thermo H 350

Integrated Heater Operating Instructions Dual Top Evo 6

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

EasyStart T. Installation instructions. Comfort Timer with 7-day preset capability.

HYDRONIC L-II Troubleshooting and Repair Instructions

PORTABLE ENGINE HEATER AND EXTERNAL BATTERY CHARGER. Specifications: Benefits: IN: NC:

MV Hydro 5. MV Hydro 5-S Diesel Powered Water Heater Instruction Manual Ed MV Heating UK Ltd

Hydronic D5 (Chevy Duramax Application)

HEATING SYSTEMS Systèmes de chauffage. THERMO PRO 50 Eco. Spare Parts List Liste de pieces détachées

Thermo 230 / 231 / 300 / 301 / Troubleshooting

Sensor module. Operating instructions. Sensor module, Type 17-51P2-... Document No P2-7D0001 Version: 17 May 2011/Rev. 0

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

BlueHeat Coolant Heater

Hydronic 4/5 (Coolant Heaters)

Connection of auxiliary heater in coolant circuit of W12 engine

Product Support Bulletin

HEATING SYSTEMS Systèmes de chauffage. THERMO PRO 50 Eco. Spare Parts List Liste de pieces détachées

HEATING SYSTEMS. Thermo plus 230 Thermo plus 300 Thermo plus 350. Thermo plus Rail. Workshop Manual. Rev. 04/2018 Id.No B

YUHUA PRE-HEATER ALWAYS THE RIGHT ANSWER

FLAME115 INFRARED HEATER SERVICE MANUAL INDEX FIRE 115 WARNING

Installation, operating and servicing instructions

200i User s information manual

Operating instructions

Calaer Marine add-on kit manual. 2kW Calaer air heater 4kW Calaer air heater

Installation instructions and operating manual. Sauna control system FCU1000 / FCU1200

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Thermo 230 Thermo 300 Thermo 350 with control unit 1572 model.30 and up

MV Hydro 9 Diesel Powered Water Heater Instruction Manual Ed. 2.00

INSTALLATION GUIDE AND OWNER S MANUAL. AccuMix II ELECTRIC INSTANTANEOUS WATER HEATER WITH ASSE 1070 APPROVED MIXING VALVE

Hybernator. Espar Heater Systems. Installation Instructions Operating Instructions. Rail Mount P/N

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

AGREEMENT. Addendum 121: Regulation No Date of entry into force: 18 January 2006

User s Manual for FT SERIES THE

Installation Instructions

Hydronic Boat Heating Kit


LS Condensate Removal Pump Installation, Operation and Service Instructions

D3LC compact Air Heater. Espar. Installation Troubleshooting & Parts Manual. D3LC compact

Marine heater installation guide

Marine Air Heater Systems. Air Top 2000 S Air Top 3500 Air Top Do-It-Yourself Kit

Operating and Maintenance Instructions

FJH-3 5B1/(2) Fuel Fired Air Heater Manual of Installation Operation and Maintenance

Airtronic D2 / D4 / D4+ Operating Instructions and Service Book

USER S INFORMATION MANUAL

model No: ir20.v2 FUSE

Vulcan Fire Module WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

Infrared Diesel Heater

Marine heater installation guide

User Guide Compact-7 series

Transcription:

Visit for more technical information & downloads. Wasserheizgeräte Water Heaters Chauffages à eau Einbauanweisung Installation Instructions Instructions de montage Thermo 90 S Thermo 90 ST Thermo 90 S Thermo 90 S Thermo 90 S-ADR (Benzin) (Petrol) (Essence) (Diesel) (Gas-oil) (Gefahrguttransport) (Transport of hazardous goods) (Transport de marchandises dangereuses) 05/2008 1301494C Thermo 90 ST (Benzin) (Petrol) (Essence) Thermo 90 ST (Diesel) (Gas-oil) Thermo 90 ST-ADR (Gefahrguttransport) (Transport of hazardous goods) (Transport de marchandises dangereuses)

Visit for more technical information & downloads. Das unsachgemäße Einbauen oder Reparieren von Webasto Heiz- und Kühlsystemen kann Feuer verursachen oder zum Austritt von tödlichem Kohlenmonoxid führen. Dadurch können schwere oder tödliche Verletzungen hervorgerufen werden. Für den Einbau und die Reparatur von Webasto Heiz- und Kühlsystemen bedarf es eines Webastotrainings, technischer Dokumentation, Spezialwerkzeuge und einer Spezialausrüstung. Versuchen Sie NIEMALS, Webasto Heiz- oder Kühlsysteme einzubauen oder zu reparieren, wenn Sie das Webastotraining nicht erfolgreich abgeschlossen und dabei die notwendigen technischen Fähigkeiten erworben haben und die für einen sachgerechten Einbau und Reparatur nötigen technischen Dokumentationen, Werkzeuge und Ausrüstungen nicht zur Verfügung stehen. Befolgen Sie IMMER alle Webasto Einbau- und Reparaturanleitungen, und beachten Sie alle Warnhinweise. Webasto übernimmt keine Haftung für Mängel und Schäden, die auf einen Einbau durch ungeschultes Personal zurückzuführen sind. Improper installation or repair of Webasto heating and cooling systems can cause fire or the leakage of deadly carbon monoxide leading to serious injury or death. To install and repair Webasto heating and cooling systems you need to have completed a Webasto training course and have the appropriate technical documentation, special tools and special equipment. NEVER try to install or repair Webasto heating or cooling systems if you have not completed a Webasto training course, you do not have the necessary technical skills and you do not have the technical documentation, tools and equipment available to ensure that you can complete the installation and repair work properly. ALWAYS carefully follow Webasto installation and repair instructions and heed all WARNINGS. Webasto rejects any liability for problems and damage caused by the system being installed by untrained personnel.

Visit for more technical information & downloads. La réparation ou l installation impropre des systèmes de chauffage et de refroidissement Webasto peut conduire à l incendie de l appareil ou encore à des fuites mortelles de monoxyde de carbone pouvant entraîner de graves lésions voire même la mort. Pou l installation ou la réparation des systèmes de chauffage ou de refroidissement Webasto, il est nécessaire d avoir une formation Webasto, une documentation technique, des outils spécifique et des équipements particuliers. N essayez JAMAIS d installer ou de réparer un système de chauffage ou de refroidissement Webasto si vous n avez pas suivi avec succès la formation Webasto et obtenu ainsi les capacités techniques indispensables et si vous ne disposez pas de la documentation technique, des outils et des équipements nécessaires à une installation ou à une réparation dans les règles de l art. TOUJOURS suivre scrupuleusement les instructions Webasto relatives à l installation et à la réparation des appareils et tenir compte de toutes les MISES EN GARDE. Webasto décline toute responsabilité en cas de problème ou de dommage causé par un système ayant été installé par du personnel non qualifié.

Visit for more technical information & downloads.

Visit for more technical information & downloads. Inhaltsverzeichnis 1 Gesetzliche Bestimmungen für den Einbau........... 1 2 Verwendung / Ausführung.......................... 4 3 Einbau.......................................... 5 4 Einbaubeispiele................................... 6 5 Anschluss an das Kühlsystem des Fahrzeuges........ 7 6 Brennstoffversorgung............................. 8 7 Brennluftversorgung.............................. 13 8 Abgasleitung.................................... 14 9 Elektrische Anschlüsse........................... 15 10 Schaltpläne..................................... 17 11 Erstinbetriebnahme............................... 28 12 Störungen...................................... 29 13 Technische Daten................................ 31 Table of contents 1 Statutory regulations governing installation.......... 35 2 Use / version.................................... 38 3 Installation...................................... 39 4 Examples for installation.......................... 40 5 Connection to the vehicle cooling system............ 41 6 Fuel supply..................................... 42 7 Combustion air supply............................ 47 8 Exhaust pipe.................................... 48 9 Electrical connections............................ 49 10 Circuit diagrams................................. 51 11 Initial start-up................................... 62 12 Troubleshooting................................. 63 13 Technical data................................... 65 I

Visit for more technical information & downloads. Statutory regulations governing installation 1 Statutory regulations governing installation 1.1. Statutory regulations governing installation The heater has been type-tested and approved in accordance with EC Directives 72/245/EEC (EMC), 2001/ 56/EC (heater) and ECE R122 with the following EC permit numbers: e1*2001/56*2004/78*0005*-- e1*72/245*95/54*1173*-- e1*2001/56*2004/78*0019*-- E1 R122 00 0217 Primarily the regulations of Annex VII of the Directive 2001/56/EG and Part 2 or Annex 7 of the directive ECE R122 must be observed for the installation. NOTE: The provisions of these Directives are binding within the territory governed by EU Directive 70/156/EEC and should similarly be observed in countries without specific regulations. IMPORTANT Failure to follow the installation instructions and the notes contained therein will lead to all liability being refused by Webasto. The same applies if repairs are carried out incorrectly or with the use of parts other than genuine spare parts. This will result in the invalidation of the type approval for the heater and therefore of its homologation / EC type licence. (Extract from Directive 2001/56/EC Annex VII) 1.7.1. A clearly visible tell-tale in the operator's field of view shall inform when the combustion heater is switched on or off. 2. Vehicle installation requirements 2.1. Scope 2.1.1.Subject to paragraph 2.1.2, combustion heaters shall be installed according to the requirements of this Annex. 2.1.2.Vehicles of category O (trailers) having liquid fuel heaters are deemed to comply with the requirements of this Annex. 2.2. Positioning of heater 2.2.1. Body sections and any other components in the vicinity of the heater must be protected from excessive heat and the possibility of fuel or oil contamination. 2.2.2. The combustion heater shall not constitute a risk of fire, even in the case of overheating. This requirement shall be deemed to be fulfilled if the installation ensures an adequate distance to all parts and suitable ventilation, by the use of fire resistant materials or by the use of heat shields. 2.2.3. In the case of M2 and M3 vehicles, the heater must not be positioned in the passenger compartment. However, an installation in an effectively sealed envelope which also complies with the conditions in paragraph 2.2.2 may be used. 2.2.4. The label referred to in paragraph 1.4 (model plate), or a duplicate (duplicate model plate), must be positioned so that it can be easily read when the heater is installed in the vehicle. 35

Visit for more technical information & downloads. Statutory regulations governing installation 2.2.5 Every reasonable precaution should be taken in positioning the heater to minimise the risk of injury and damage to personal property. 2.3. Fuel supply 2.3.1. The fuel filler must not be situated in the passenger compartment and must be provided with an effective cap to prevent fuel spillage. 2.3.2. In the case of liquid fuel heaters, where a supply separate to that of the vehicle is provided, the type of fuel and its filler point must be clearly labelled. 2.3.3. A notice, indicating that the heater must be shut down before refuelling, must be affixed to the fuelling point. In addition a suitable instruction must be included in the manufacturer's operating manual. 2.4. Exhaust system 2.4.1. The exhaust outlet must be located so as to prevent emissions from entering the vehicle through ventilators, heated air inlets or opening windows. 2.5. Combustion air inlet 2.5.1. The air for the combustion chamber of the heater must not be drawn from the passenger compartment of the vehicle. 2.5.2. The air inlet must be so positioned or guarded that blocking by rubbish or luggage is unlikely. 2.6. Heating air inlet 2.6.1. The heating air supply may be fresh or recirculated air and must be drawn from a clean area not likely to be contaminated by exhaust fumes emitted either by the propulsion engine, the combustion heater or any other vehicle source. 2.6.2. The inlet duct must be protected by mesh or other suitable means. 2.7. Heating air outlet 2.7.1. Any ducting used to route the hot air through the vehicle must be so positioned or protected that no injury or damage could be caused if it were to be touched. 2.7.2. The air outlet must be so positioned or guarded that blocking by rubbish or luggage is unlikely. 2.8. Automatic control of the heating system The heating system must be switched off automatically and the supply of fuel must be stopped within five seconds when the vehicle's engine stops running. If a manual device is already activated, the heating system can stay in operation. NOTE: Contrary to point 2.2.3 the heater must also not be installed in the passenger cabin of class M1 and N vehicles. However, an installation in an effectively sealed envelope which also complies with the conditions in paragraph 2.2.2 may be used. 36

Visit for more technical information & downloads. (Extract from Directive 2001/56/EC Annex IX) 3. Technical specifications for heater units for installation in dangerous goods transporters (Annex 9) 3.1. General (EX/II, EX/III, AT, FL and OX vehicles) 3.1.1. The combustion heaters and their exhaust gas routing shall be designed, located, protected or covered so as to prevent any unacceptable risk of heating or ignition of the load. This requirement shall be considered as fulfilled if the fuel tank and the exhaust system of the appliance conform to the provisions set out in the points 3.1.1.1 and 3.1.1.2. Compliance with those provisions shall be verified on the completed vehicle. 3.1.1.1. Any fuel tanks for supplying the appliance shall meet the following requirements: a) in the event of any leakage, the fuel shall drain to the ground without coming into contact with hot parts of the vehicle or the load; b) fuel tanks containing petrol shall be equipped with an effective flame trap at the filler opening or with a closure enabling the opening to be kept hermetically sealed. 3.1.1.2. The exhaust system as well as the exhaust pipes shall be so directed or protected to avoid any danger to the load through heating or ignition. Parts of the exhaust system situated directly below the fuel tank (diesel) shall have a clearance of at least 100 mm or be protected by a thermal shield. 3.1.2. The combustion heater shall be switched on manually. Programming devices shall be prohibited. Statutory regulations governing installation 3.2. EX/II and EX/III vehicles Combustion heaters using gaseous fuels are not permitted. 3.3. FL vehicles 3.3.1. The combustion heaters shall be put out of operation by at least the following methods: a) intentional manual switching off from the driver s cab; b) stopping of the vehicle engine; in this case the heating device may be restarted manually by the driver; c) start-up of a feed pump on the motor vehicle for the dangerous goods carried. 37

Visit for more technical information & downloads. Use / version 2 Use / version 2.1. Use of the water heaters The Webasto water heater is used in connection with the vehicle's own heating system to heat the cab, to defrost the vehicle windows and to preheat water-cooled engines. The water heater operates independently of the engine and is connected to the cooling system, the fuel system and the electrical system of the vehicle. The Thermo 90 S and Thermo 90 ST heaters differ from each other in their component plug and in the fact that they have different control modules. 2.2. Versions 2.2.1. Thermo 90 S version Thermo 90 S petrol Water heater for "petrol" fuel Thermo 90 S diesel Water heater for "diesel" fuel The water heaters are designed for 12 V (Thermo 90 S petrol) and for 12 or 24 V (Thermo 90 S diesel). 2.2.2. Thermo 90 ST version Thermo 90 ST petrol Water heater for "petrol" fuel Thermo 90 ST diesel Water heater for "diesel" fuel The water heaters are designed for 12 V (Thermo 90 ST petrol) and for 12 or 24 V (Thermo 90 ST diesel). 38

Visit for more technical information & downloads. Installation 3 Installation IMPORTANT The water heater must be installed outside the passenger cabin. The requirements of the latest version of the ADR must also be observed for the installing the heater into vehicles used to transport hazardous substances. NOTE: If the vehicle manufacturer has issued instructions, they must be followed. 3.2. To install the heater The heater must be secured with at least three M8 screws. The screws must be tightened with a torque of 18 Nm. 3.3. Model plate The model plate must be positioned so that it cannot be damaged and must be clearly legible when the heater is installed (otherwise a duplicate model plate must be used). Inapplicable years must be erased from the model plate. 3.1. Installation site / Installation position The heater must be installed in as low a position as possible to allow the heater and circulating pump to be bled automatically. This is particularly important as the circulating pump is not self-priming. Fig. 1: Permitted installation positions for the Thermo 90 S / Thermo 90 ST 39

Visit for more technical information & downloads. Examples for installation 4 Examples for installation Wiring harness Fuel line Exhaust line Water circuit Fig. 2: Without non-return valve Installation example for the heater With non-return valve and thermostat 1 Heat exchanger, car s heating system 2 Switch for car s heating system fan 3 Relay for vehicle fan 4 Digital timer 5 Fuse strip in the car 6 Non-return valve with leakage hole 40 7 T-piece 8 Vehicle engine 9 Heater 10 Circulating pump 11 Water pump 12 Radiator 13 Regulating valve 14 Exhaust silencer 15 Metering pump 16 Combustion air intake line 17 Thermostat 18 Control module (optional on the Thermo 90 S) 19 Control module (installation position of the Thermo 90 ST and optional for the Thermo 90 S)

Visit for more technical information & downloads. Connection to the vehicle cooling system 5 Connection to the vehicle cooling system In thermostat circuits, only use thermostats which start to open at < 65 C. The heater is connected to the vehicle cooling system as shown in Figure 2. The system must contain at least 6 litres of coolant. The water hoses supplied by Webasto must always be used. If you do not use these hoses, the hoses that you do use must comply with DIN 73411. The hoses must be installed without kinks and (to ensure perfect bleeding) rising if possible. Hose connections must be supported by hose clips to prevent them slipping. NOTE: The hose clips must be tightened with a torque of 4 Nm. The cooling system must be bled carefully before using the heater for the first time or after replacing the coolant. The heater and lines should be installed in such a way as to ensure static bleeding. Perfect ventilation can be identified by the circulating pump operating almost silently. 41

Visit for more technical information & downloads. Fuel supply 6 Fuel supply The fuel is taken from the vehicle fuel tank or from a separate fuel tank. The values for the maximum pressure at the fuel extraction point are shown in the table below. Permissible fuel inflow height H (m) At max. pressure (bar) in fuel line 0.00 0.2 1.00 0.11 2.00 0.03 Maximum fuel intake height S (m) At max. negative pressure (bar) in the fuel tank 0.00-0.10 0.50-0.06 1.00-0.02 Only for ADR: The statutory regulation of ADR (Accord européen relatif au transport international des marchandises dangereuses par route) governing fuel tanks, part 9 para. 9.2.4.7, must be adhered to. NOTE: A sign must be affixed to the fuel filler neck warning that the heater must be switched off before refuelling. l 1 + l 2 10 m l 2 1.2 m l 2 8.8 m Fig. 3: Fuel supply 42

Visit for more technical information & downloads. Fuel supply 6.1. Vehicles with diesel engines The fuel must be taken from the vehicle fuel tank or from a separate tank (see Figs. 4, 5 and 6). Plastic tank Fuel extractor Sealing ring Sealing ring Tank fittings Fig. 5: Fuel pickup from the plastic tank (Pickup via tank drain screw) Hole pattern Only use a tank connector if the fuel tank is made from metal Fig. 4: Fuel pickup from the plastic tank (Pickup via tank fitting) NOTE: Deburr the cut on the tank connector after sawing it off and remove any metal chips. Fig. 6: Webasto tank connector NOTE on Fig. 6: The fitting must be made from metal! 43

Visit for more technical information & downloads. Fuel supply 6.2. Vehicles with petrol engines The heater must be integrated into the return line of fuel systems in carburettor and injection engines with a return line. In carburettor engines without a return line the heater must be integrated into the fuel system in the supply line between the fuel tank and the vehicle pump. NOTE A fuel feed line can normally be identified by the fact that a fuel filter is installed in it. NOTE: If there is an evaporation tank in the vehicle s fuel system, the fuel must be extracted upstream of the evaporation tank. from tank to engine Fuel may only be taken from the supply or return line using the special Webasto fuel extractor (see Figure 7). The fuel extractor must be fitted in such a way that any air or gas bubbles are automatically discharged towards the tank (see Figure 7). Air or gas bubbles may be produced in the vehicle s fuel line if there are leaks in the carburettor or vehicle fuel pump or if the ambient temperature is higher than the evaporation temperature of the fuel. The fuel extractor must not be located near the engine, as gas bubbles may form in the lines on account of heat radiated from the engine. This may cause problems during combustion. When installing the heater in a vehicle with fuel injection system, it is important to establish whether the fuel pump is located inside or outside the tank. If the fuel pump is located inside the tank, fuel can only be extracted from the return line. In this case it must be ensured that the return line continues almost to the bottom of the tank and is not sealed by a non-return valve. If this is not the case the return line may be extended. Fig. 7: to metering pump Webasto fuel extractor If the fuel pump is installed outside the tank, the fuel connection may be made between the tank and the fuel pump. 6.3. Fuel lines Only steel, copper and plastic lines of plasticised, light and temperaturestabilized PA 11 or PA 12 (e.g. Mecanyl RWTL) pursuant to DIN 73378 may be used for the fuel lines. 44

Visit for more technical information & downloads. Fuel supply NOTE: Cut Mecanyl lines without burr and do not crush them. Do not cut them with side-cutting pliers. Since the lines normally cannot be routed with a constant rising gradient, the internal diameter must not be allowed to exceed a certain size. Air or gas bubbles will accumulate in lines with an internal diameter of more than 4 mm and these will cause malfunctions if the lines sag or are routed downwards. The diameters specified in Figures 3 and 7 will ensure that bubbles do not form. The lines should not be routed downwards from the metering pump to the heater. Unsupported fuel lines must be secured to prevent them sagging. They must be installed in such a way that they cannot be damaged by flying chippings and high temperatures (exhaust line). 6.3.1. Connecting two pipes with a hose The correct procedure for connecting fuel lines with hosing is illustrated in Fig. 8. NOTE: Ensure that there are no leaks. Correct Clip Wrong Bubble Fig. 8: Pipe / hose connection 12 V and 24 V petrol and diesel Bubble 6.4. Metering pump with damper The metering pump is a combined delivery, metering and shutoff system and is subject to specific installation criteria (see Figs. 3, 9 and 10). 6.4.1. Installation location Before installing the metering pump, ensure that the maximum pressure occurring at the pickup point is less than 0.2 bar. Fig. 9: Metering pump DP2 Installation position and attachment It is advisable to install the metering pump in a cool place. The maximum ambient temperature must not exceed + 20 C for petrol and + 40 C for diesel at any time during operation. The metering pump and fuel lines must not be installed within range of the radiated heat from hot vehicle parts. A heat shield must be used if necessary. 45

Visit for more technical information & downloads. Fuel supply 12 V and 24 V diesel only 0-90 Fig. 11: Fuel filter Fig. 10: Metering pump 30.2 Horizontal installation position The pump should ideally be installed near the tank. 6.4.2. Installation and attachment The metering pump must be secured with a vibration-damping mounting. Its installation position is limited as shown in Figs. 9 and 10 in order to ensure effective auto-bleeding. 6.5. Fuel filter Only a Webasto filter, order no. 487 171, is allowed to be used if the fuel is expected to be contaminated. Install vertically if possible, however at least horizontally. NOTE: Note the installation position and direction of flow. 46

Visit for more technical information & downloads. Combustion air supply 7 Combustion air supply Under no circumstances may the combustion air be taken from areas occupied by people. The combustion air intake opening must not point in the direction of travel. It must be located so that it cannot become clogged with dirt or snow and cannot suck in splashing water. The combustion air intake line (internal diameter at least 30 mm) may be 0.5 m to 5 m long with several bends totalling 360. The minimum bending radius is 45 mm. The combustion air intake must not be routed above the exhaust outlet. NOTE: If the combustion air intake line cannot be installed so that it slopes downwards, a water drain hole with a diameter of 4 mm is to be made at its lowest point. If the heater is installed in a general installation space near the vehicle s fuel tank, the combustion air must be taken in from the outside and the exhaust fumes discharged into the atmosphere. The openings must be splash-proof. A ventilation opening measuring at least 6 cm 2 is required if the heater is installed in an enclosed box. The size of the ventilation opening must be increased accordingly if the temperature in the box exceeds the permitted ambient temperature of the heater (see Technical data). 47

Visit for more technical information & downloads. Exhaust pipe 8 Exhaust pipe The exhaust pipe (internal diameter 38 mm) can be installed with a length of 0.5 m to 5 m and several bends (360 altogether, minimum bending radius 85 mm). The exhaust silencer is essential and must be installed near the heater. The opening of the exhaust pipe must not point towards the front of the vehicle (see Figure 12). An attachment is required no further than 150 mm from the end of the exhaust pipe to ensure that the angle of 90 ± 10 is achieved The exhaust pipe opening must be located so that it cannot become clogged with snow and mud. Rigid pipes of unalloyed or alloyed steel with a minimum wall thickness of 1.0 mm or flexible piping of alloyed steel only must be used as exhaust line. The exhaust pipe is secured to the heater using a clamping collar, for example. See the statutory regulations for other requirements. Only for ADR: The statutory regulation of ADR (Accord européen relatif au transport international des marchandises dangereuses par route) governing the routing of the exhaust line, part 9 para. 9.2.4.7, must be adhered to. Fig. 12: 48 Discharge direction almost vertical 90 ± 10 Exhaust pipe opening Installation position

Visit for more technical information & downloads. Electrical connections 9 Electrical connections 9.1. Control module / heater connection The electrical connection of the heaters is made as shown in the circuit diagrams in Figures 15, 16, 17, 18, 19, 20, 21 and 22. 9.2. Connection when installing Thermo 90 S-ADR and Thermo 90 ST-ADR in a hazchem vehicle (ADR) To install the Thermo 90 S-ADR and Thermo 90 ST-ADR heaters in hazchem vehicles, the requirements of ADR/RID part 9 para. 9.2.4.7 Combustion heating systems, must also be satisfied. The electrical connection is made as shown in the circuit diagram, Figs. 17, 18, 21 and 22. NOTE: The switch S7 must be installed in such a way that a positive potential is connected to appropriate input of the control module when a pumping device is switched on. the standard clock remains free. The heater can then only be taken into service using the immediate heat button (circuit diagram available on request). The use of other timers in ADR vehicles is not permitted. 9.3. Connecting the controls The heater can be switched on and off using the following Webasto controls: Timer, see circuit diagrams in Figures 15, 16, 19 or 20. Switch, see circuit diagrams in Figures 17, 18, 21 or 22. 9.4. Vehicle fan The vehicle's own heater fan is controlled using a relay, see circuit diagram Figs. 15, 16, 17, 18, 19, 20, 21, 22 or using a relay with a cabin thermostat. If there is no earth via Y2 or H5 at control module input X12/5 (Thermo 90 S) or X8/5 (Thermo 90 ST) when it is switched on, all the ADR functions are disabled. After activating the positive potential at control module input X12/5 (Thermo 90 S) or X8/5 (Thermo 90 ST) (auxiliary power take-off on) a brief run-on time of 20 seconds on the Thermo 90 S (40 seconds on the Thermo 90 ST) will take place, following which the control module will be in Fault lock-out mode. IMPORTANT In accordance with the technical specifications of the act governing the road haulage of hazardous materials, heaters are only allowed to be taken into service with a special manually operated switch fitted in the cab. If the system is equipped with a standard clock, ensure that contact 4 on 49

Visit for more technical information & downloads. Electrical connections 9.5. Thermo 90 S control module The control module offers protection type IP6K4K if it is installed in the position shown in Figure 13. Fig. 13: Thermo 90 S (from 03/97) control module, installation position 9.6. Thermo 90 ST control module The control module offers protection type 6K9K if it is installed in the position shown in Figure 14. 9.7. To set the regulating temperatures If the Engine on / Engine off signal (terminal D+) is applied to control module plug X12 contact 7 (Thermo 90 S) or plug X8 contact 7 (Thermo 90 ST), different regulating thresholds take effect Nominal temperature at the sensor Regulating pause Switch on again after regulating pause Engine on 72 C 82 C 67 C Engine off 80 C 90 C 75 C If the terminal D+ signal is not applied, the temperatures are the same as those at Engine off. NOTE: The selected regulating pause temperature of the heater should be lower than the opening temperature of the radiator thermostat. 24 V XXXXXXX_.XXXXX Fig. 14: Thermo 90 ST control module, arbitrary installation position 50

Visit for more technical information & downloads. Circuit diagrams 10 Circuit diagrams 10.1. Circuit diagram legend for the Thermo 90 S and Thermo 90 ST 1 Temperature coding (temperature at water outlet): See table on page 50 2 Digital timer P2: with positive at connection 10 = Continuous operation with immediate heating Connection 10 open = Variable heating duration can be programmed (10 min to 120 min); default setting 120 min 3 Vehicle fuse 4 Vehicle blower switch Cable cross-sections Cable colours < 7.5 m 7.5-15 m 0.75 mm 2 1.0 mm 2 0.75 mm 2 1.0 mm 2 1.0 mm 2 1.5 mm 2 1.5 mm 2 2.5 mm 2 2.5 mm 2 4.0 mm 2 4.0 mm 2 6.0 mm 2 bl br ge gn gr or rt sw vi ws blue brown yellow green grey orange red black violet white 51

Visit for more technical information & downloads. Circuit diagrams 10.2. Thermo 90 S circuit diagram legend Item Designation Comment A1 Heater A2 Control module B1 Flame sensor B2 Temperature sensor B3 Temperature limiter/ Overheating guard B4 Room thermostat E Glow plug F1 Fuse 20 A Flat fuse SAE J 1284 F2 Fuse 5 A Flat fuse SAE J 1284 F3 Fuse 20 A Flat fuse SAE J 1284 H1 Heating symbol in the display Operating indicator (in item P2) H2 Light max. 2 W Operating indicator (in item S4) H3 Symbol light Light (in item P2) H5 Lamp, min. 1.2 W Switch-on indicator pumping device H6 Red LED Immediate heat button light, ready indicator, switch-on control (in item P2) K3 Relay Circulating pump remote control K5 Relay for vehicle fan M1 Motor Combustion air fan M2 Motor Circulating pump M3 Motor Vehicle fan P2 Digital timer For programmed operation S4 Switch ON/OFF Item Designation Comment S5 1 or 2-pin disconnecting switch Emergency off switch, electric or pneumatic S7 Pumping device switch to positive S8 Momentary-contact switch Immediate heat button remote control S9 Switch Heating/Circulating pump remote control S10 Switch Battery switch in positive X1 12-pin plug connection to item A1 X3 12-pin plug connection to item P2 X5 Plug connector, 2-pin to Y1 X6 Plug connector, 2-pin Diagnostics X11 12-pin plug connection To item A2 (ST 1) X12 12-pin plug connection To item A2 (ST 2) X13 Plug connector, 2-pin To item A2 (ST 3) Y1 Metering pump Fuel pump for heater Y2 Solenoid valve for pumping device 52

Visit for more technical information & downloads. Circuit diagrams ϑ ϑ Fig. 15: System circuit for Thermo 90S, 12 and 24 V, with standard timer, see pages 51 and 52 for legend 53

Visit for more technical information & downloads. Circuit diagrams E B2 X1 B3 1 2 X1 3 4 5 6 X3 X5 X6 X11 (ST 1) X12 (ST 2) X13 (ST 3) M1 58 15 B1 M2 12 11 10 9 8 7 3 6 9 12 1 2 1 2 2 1 11 9 7 5 3 1 11 9 7 5 3 1 2 1 58 15 30 30 E ϑ ϑ Y1 M M2 M1 B3 B1 B2 A1 M3 31 31 Fig. 16: System circuit for Thermo 90 S, 12 and 24 V, with standard timer and separate circulating pump control, see pages 51 and 52 for legend 54 P2 H3 1 12 br 4 10 H1 7 F2 F3 X6 1 2 F1 4 S8 rt 11 H6 2 8 X3 S9 sw ws K3 86 87 87a 86 87 87a 85 X12 (ST 2) 3 4 br rt rt ge rt br sw bl ws/bl vi 2 1 8 6 7 5 11 9 10 1 5 8 4 12 9 2 3 11 7 10 6 1 2 vi/bl gr or or 30 85 sw X11 (ST 1) ge 12 br br bl gn 1 12 8 5 6 7 2 11 3 10 9 4 sw M br M vi vi gr gr gn gn X13 (ST 3) X1 bl br 2 A2 X5 B4 K5 br gn/ws rt/bl rt 30 sw 0 3 1 2

Visit for more technical information & downloads. Circuit diagrams ϑ ϑ Fig. 17: System circuit for Thermo 90 S ADR, 24 V, with switch, see pages 51 and 52 for legend 55

Visit for more technical information & downloads. Circuit diagrams ϑ ϑ Fig. 18: System circuit for Thermo 90 S ADR, 24 V, with switch without auxiliary drive, see pages 51 and 52 for legend 56

Visit for more technical information & downloads. Circuit diagrams 10.3. Thermo 90 ST circuit diagram legend Item Designation Comment A1 Heater A2 Control module B1 Flame sensor B2 Temperature sensor B3 Temperature limiter/ Overheating guard B4 Room thermostat E Glow plug F1 Fuse 20 A Flat fuse SAE J 1284 F2 Fuse 5 A Flat fuse SAE J 1284 F3 Fuse 20 A Flat fuse SAE J 1284 H1 Heating symbol in the display Operating indicator (in item P2) H2 Light max. 2 W Operating indicator (in item S4) H3 Symbol light Light (in item P2) H5 Lamp, min. 1.2 W Switch-on indicator pumping device H6 Red LED Immediate heat button light, ready indicator, switch-on control (in item P2) K3 Relay Circulating pump remote control K5 Relay for vehicle fan M1 Motor Combustion air fan M2 Motor Circulating pump M3 Motor Vehicle fan P2 Digital timer For programmed operation S4 Switch ON/OFF Item Designation Comment S5 1 or 2-pin disconnecting switch Emergency off switch, electric or pneumatic S7 Pumping device switch to positive S8 Momentary-contact switch Immediate heat button remote control S9 Switch Heating/Circulating pump remote control S10 Switch Battery switch in positive X1 Plug connector, 4-pin to item A2 X2 Plug connector, 2-pin to item A2 X3 Plug connector, 2-pin to item A2 X4 Plug connector, 2-pin to item A2 X5 Plug connector, 2-pin to item A2 X6 Plug connector, 2-pin to item A2 X7 Plug connector, 2-pin to item A2 X8 12-pin plug connection To item A2 (ST 2) X9 12-pin plug connection to item P2 X10 Plug connector, 2-pin W-Bus diagnostic X11 Plug connector, 2-pin to Y1 Y1 Metering pump Fuel pump for heater Y2 Solenoid valve for pumping device 57

Visit for more technical information & downloads. Circuit diagrams Fig. 19: System circuit for Thermo 90 ST, 24 V, with standard timer, see pages 51 and 57 for legend 58

Visit for more technical information & downloads. Circuit diagrams Fig. 20: System circuit for Thermo 90 ST, 24 V, with standard timer and separate circulating pump control, see pages 51 and 57 for legend 59

Visit for more technical information & downloads. Circuit diagrams Fig. 21: System circuit for Thermo 90 ST ADR, 24 V, with switch, see pages 51 and 57 for legend 60

Visit for more technical information & downloads. Circuit diagrams Fig. 22: System circuit for Thermo 90 ST ADR, 24 V, with switch without auxiliary drive, see pages 51 and 57 for legend 61

Visit for more technical information & downloads. Initial start-up 11 Initial start-up NOTE: Refer to the safety instructions in the operating and maintenance instructions. The operating and maintenance instructions must be read through without fail before starting the heater. After you have installed the heater, bleed the water system and the fuel supply system carefully. Follow the instructions supplied by the vehicle manufacturer for this purpose. Conduct a trial of the heater to check all the water and fuel connections for leaks and to ensure that they are secure. If the heater suffers a fault during operation, the fault must be located and remedied. 62

Visit for more technical information & downloads. Troubleshooting 12 Troubleshooting 12.1. Fault lock-out Fuel is supplied for max. 240 seconds if the flame does not start to burn. Fuel is supplied for max. 240 seconds if the flame goes out during operation. The fuel supply is shut off if the system overheats (temperature limiter is tripped). Once the cause of the fault has been eliminated, the fault lock-out is cancelled by switching the heater off and on again. If the undervoltage guard switches off the system Thermo 90 S Thermo 90 ST 12 V 10.5V 0.5V 10.5V 0.5V 24 V 21V 1V 21V 1V for longer than 20 seconds, the fuel supply is interrupted. 12.2. Diagnostic after a fault lock-out for the Thermo 90 S and Thermo 90 ST Check the fuses and plug connectors. 12.2.1. Version with timer If the system is equipped with a standard clock, a fault message appears on the display of the timer after a fault occurs: F 00 Heater lock-out or control unit defective, Unlocking only possible by an authorised workshop F 01 No start (after 2 attempts to start) F 02 Flame failure F 03 Undervoltage or overvoltage F 04 Premature flame recognition F 05 Flame sensor interrupt or flame sensor short-circuit F 06 Temperature sensor interrupt or temperature sensor short-circuit F 07 Metering pump interrupt or metering pump short-circuit F 08 Blower motor interrupt or blower motor short-circuit or blower motor incorrect speed F 09 Glow plug interrupt or glow plug short-circuit F 10 Overheating F 11 Circulating pump interrupt or circulating pump short-circuit 63

Visit for more technical information & downloads. Troubleshooting 12.2.2. Version with switch If the system is operated with a switch, the nature of the fault is indicated by a flashing code on an indicator light during the run-on time of the heater. After five short signals, count the long flashes: 0x 1x 2x 3x 4x 5x 6x 7x 8x 9x 10x 11x (only five short signals) Heater lock-out or control unit defective, Unlocking only possible by an authorised workshop No start (after 2 attempts to start) Flame failure Undervoltage or overvoltage Premature flame recognition Flame sensor interrupt or flame sensor short-circuit Temperature sensor interrupt or temperature sensor short-circuit Metering pump interrupt or metering pump short-circuit Blower motor interrupt or blower motor short-circuit or blower motor incorrect speed Glow plug interrupt or glow plug short-circuit Overheating Circulating pump interrupt or circulating pump short-circuit 64

Visit for more technical information & downloads. Technical data 13 Technical data Except where limit values are specified, the technical data on the right refer to the usual heater tolerances of ± 10 % at an ambient temperature of + 20 C and at nominal voltage. 13.1. Electrical components: The control module, motors for combustion air blower and circulating pump, glow plug, switch and timer (no timer for ADR mode) are designed for either 12 V or 24 V. The temperature limiter, temperature sensor and flame sensor are identical on 12 V and 24 V heaters. 13.2. Fuel for Thermo 90 S and Thermo 90 ST petrol: The fuel specified by the manufacturer must be used. Both leaded and unleaded fuel may be used. 13.3. Fuel for and Thermo 90S-ADR /Thermo 90 ST-ADR (diesel): The diesel fuel specified by the manufacturer must be used. We know of no negative influences due to additives. If fuel is extracted from the vehicle s tank, follow the additive instructions issued by the vehicle manufacturer. If you change to low-temperature fuel, the heater must be operated for approx. 15 minutes so that the fuel line and fuel pump are filled with the new fuel. 65

Visit for more technical information & downloads. Technical data Heater Operation Thermo 90 S / ST Petrol Thermo 90 S diesel Thermo 90 S-ADR Thermo 90 ST diesel Thermo 90 ST-ADR EC licensing symbol 00 0005* / 00 19* 00 0005* Model Water heater with Ferro-tec technology Heat output Max. 9.1 kw regulating range 2.0 kw 7.6 kw 1.8 kw 7.6 kw Fuel Petrol Diesel Fuel consumption Max. regulating 1.1 l/h range 0.25 l/h 1.0 l/h 0.19 l/h 0.9 l/h Rated voltage 12 V 12 or 24 V Operating voltage range 10... 15 V 10... 15 or 20... 30 V Nominal power consumption with circulation Max. regulating 90 W pump (without vehicle fan) range 37 W - 83 W 37 W - 83 W Max. ambient temperature: Heater: - Operation -40... +110 C (90 C with control module installed on the heater) - Storage -40... +110 C (90 C with control module installed on the heater) Control module:- Operation -40... +75 C -40... +75 C -40... +85 C - Storage -40... +85 C Metering pump: - Operation -40... +20 C -40... +40 C - Storage -40... +85 C Max. operating pressure (heat medium) Max. 2.0 bar Capacity of the heat exchanger 0.15 l Max. combustion air intake temperature +40 C Minimum capacity of the system 6.00 l Delivery rate of the circulating pump against 1650 l/h 0.15 bar CO 2 in the exhaust fumes (normal function range) Max. 10... 12.0 % by volume CO 2 - adjustment values at approx. + 20 C Max. 0 m 500 m 1000 m and geographic altitude above sea level 10 % 10.6 % 11.3 % Heater dimensions (tolerance ± 3 mm) * Control module installed on the heater L 310 (355*) mm W 131 mm Weight 66 L 310 (355*) / 307(352*) mm W 131 mm H 232 mm H 232 mm 4.8 kg L 307 (352*) mm W 131 mm H 232 mm

Visit for more technical information & downloads. Technical data Thermo 90 S 3 ø20 5 ø39 29 45 ø5 ø6,5 126 88 120 100 95 134 78 89 99 1 Combustion air intake 2 Exhaust fume outlet 3 Fuel intake 4 Coolant intake 5 Coolant outlet ø30 1 2 ø38 48,6 98,6 = 137,1 100 = ø20 ø74 355 384 131 4 Thermo 90 ST ø5 3 5 ø20 ø39 45 92 99 152 88 1 2 ø30 ø38 95 ø20 4 89 1 Combustion air intake 2 Exhaust fume outlet 3 Fuel intake 4 Coolant intake 5 Coolant outlet 49 99 = = 137 100 352 381 ø74 131 Fig. 23: Dimensions of the heaters 67

Visit for more technical information & downloads. Im Fall einer mehrsprachigen Version ist Deutsch verbindlich. In multilingual versions the German language is binding. Dans le cas d'une version rédigée en plusieurs langues, l'allemand est alors la langue qui fait foi. Webasto AG Kraillinger Strasse 5 82131 Stockdorf GERMANY http://dealers.webasto.com http://www.webasto.com Änderungen vorbehalten Subject to modification Sous réserve de modifications 2007 All Rights Reserved IDENT.-NR. 1301494C