STANDARD DETAILS & SPECIFICATIONS Spec No _SI _ Rev. Date 10/20/11

FIRE SAFETY GUIDELINES

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

MINNESOTA STATE DEPARTMENT OF PUBLIC SAFETY

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Large Family Daycare Guideline

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

FIREDEPARTMENT REGULATIONS AND GUIDELINES

Fire Evacuation Plan Davidge Hall. UMB POLICE or

SEMINOLE FIRE DEPARTMENT TENT PERMIT CONDITIONS

PLANNING AND MANAGEMENT GUIDE for PUBLIC ASSEMBLY EVENTS

4. Distances to property line, buildings, other tents, parked vehicles and engines;

Residential Based Care Facility Guidelines

PLACES OF ASSEMBLY CHAPTER 17

TENTS AND TEMPORARY MEMBRANE STRUCTURES PERMIT PROCEDURE

Tents and Temporary Membrane Structures Packet

MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE

REGULATIONS FOR OUTDOOR GATHERINGS AND EVENTS TENTS & MEMBRANE STRUCTURES

Camden County Fire Rescue Office of the Fire Marshal 125 N. Gross Road, Kingsland, GA

Tents and Temporary Membrane Structures Permit Procedure

UC Irvine Environmental Health & Safety TITLE: Special Events Program

FIRE AND LIFE SAFETY REQUIREMENTS FOR SPECIAL EVENTS STANDARD

This regulation outlines procedures to be followed for fire drills and all school event decorations.

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

Kersey Valley Spookywoods. EMERGENCY ACTION PLAN 2018 Rev.3, September 18th, Page 1 of 5

Facility Manager Training

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

Residential-based Care Facility R-4 Guideline

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

Fire Safety Guidelines and Requirements CenturyLink Field and Event Center June 2015

For additional information please contact the Chesapeake Fire Prevention Office at or at

Township of Upper Providence Office of the Fire Marshal

West Chester Fire Dept. Fire Code Maintenance Handbook. Fire Prevention Saves Lives and Property

Fire/Life Safety Policy

Clackamas Fire District #1 Self Inspection Program. Oregon Fire Code (OFC)

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

School Fire Safety Checklist

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Fire Evacuation Plan Bressler Research Building. UMB POLICE or

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

ATTACHMENT B FIRE CODE REQUIREMENTS FOR EXHIBITS AND SPECIAL EVENTS

Fire and Life Safety Requirements San Mateo City Special Events

All temporary special events held within the City of Orlando must be approved and inspected by the Orlando Fire Department prior to holding the event.

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

Outdoor Festival and Special Event Guidelines

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

Fire Prevention Plan. California State University, Chico

Educational Occupancies

FIRE PREVENTION STANDARDS

SAFETY GUIDELINES INDIANA STATE FAIRGROUNDS & EVENT CENTER. Fairgrounds Security:

MULTI-LEVEL & COVERED BOOTH CONDITIONS

FIRE INSPECTORS GUIDELINES FOR PLAN REVIEWS AND INSPECTIONS OF NEW CONSTRUCTION / ADDITIONS AND CHANGE OF OCCUPANCY

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

OXNARD FIRE DEPARTMENT Fire Watch Guidelines

Residential-based Care Facility R2.1 Guideline

Common Fire Code Violation Checklist. Listed are some of the most commonly found fire code violations and should not be considered as all inclusive.

What are the Contents of an Effective Fire Safety Plan? Name: Date: Address of Project: Building Permit Number:

New School Construction: Safe School Opening. OAR and IOR Joint Training February 17, 2005

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

OCFEC Fire Marshal Summary Report

St. John s University

OAK GROVE SCHOOL DISTRICT SCHOOL SITE FIRE PREVENTION PLAN

ICC CODE CORNER 2015 International Fire Code

Date Issued: December 14, 2017 Revision: 2.1

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Florida Building Code 2010

Agency for Health Care Administration

Level I Chapter 1 Worksheet

Calgary Fire Department Indoor Special Event Requirements. August calgary.ca /fire call

City of Leduc Fire Services Indoor Special Event Requirements

Established /10/2015. Doran Pruisner Dan Wood

Policies - Building Rules and Regulations

GENERAL AREAS OF INSPECTION

FIRE SAFETY PLAN FOR CONSTRUCTION, RENOVATION AND DEMOLITION SITES

FIRE SERVICE FEATURES

REQUIREMENTS FOR TENTS, CANOPIES & MEMBRANE STRUCTURES

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Fire Department Fire Prevention Inspection Services. HIGH RISE STRUCTURE Fire Inspection Program

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

General Festival Conditions & Temporary Use of Tents Conditions of Approval

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Fire Safety Guide. Emergency Numbers:

Fire Safety Guide. Emergency Number:

INSPECTOR I SKILLS ADMINISTRATION

Special attention should be given to new students, to students with special needs and to students enrolled in visiting classes.

St. John s University Fire Safety Plan

CITY OF OKLAHOMA CITY SPECIAL EVENT REQUIREMENTS Revised January, 2011

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

FIRE INCIDENT REPORTING

LIFE SAFETY CODE ESSENTIALS PRESENTED BY: LARRY VIGIL, RISK CONSULTANT

Safety Manual Section 7 Fire/Life Safety

ADMINISTRATIVE SERVICES MANUAL

FIRE PLAN CHECK CORRECTION List for Commercial Occupancies

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

FIRE SAFETY PRACTICES AND PROCEDURES

Note: The event coordinator is responsible for compliance of all regulations.

Transcription:

Moreno Valley Fire Prevention Bureau Temporary Haunted Houses Approved and Authorized By: Adria Reinertson, Fire Marshal Issued: May 5, 2017

Temporary Haunted Houses PURPOSE This guide is intended to provide fire safety standards and regulations for the construction and operation of temporary haunted attractions/events that are open to the public. SCOPE These regulations shall apply to temporary Haunted Houses, Ghost Walks, and similar entertainment venues where combustible decorative material and confusing audio and/or visual effects are present. The requirements listed in this guideline were derived from the California Building Code (CBC), California Fire Code (CFC), and California Code of Regulations, Title 19. DEFINITIONS Haunted House - A structure, or portion thereof, which transports people through a course where the means of egress are not apparent due to theatrical distractions, low illumination, temporary hallways, partitions and/or multiple rooms. Ghost Walk - Similar to haunted houses and may include both indoor and outdoor areas where the means of egress to the public way are not apparent due to theatrical distractions and/or low illumination. OPERATIONAL PERMIT REQUIREMENTS Fire Prevention shall review site and floor plans and perform Fire Safety Inspections before permits are issued. 1. Provide a written emergency procedure (see below General Fire Safety Requirements #2). 2. Complete a Fire Permit Application Form. 3. Obtain partner agency approvals such as Planning, Building, Law Enforcement, City Zoning, and Health Departments as needed. FIRE SAFETY INSPECTION Owner/operator shall schedule and allow a minimum of 10 business days for a fire inspection after all required paperwork and approvals are received from the Building and Fire Departments. A Fire Safety Inspection is required prior to occupancy.

Permits shall be secured from the building department as required for any structural and/or electrical modifications. Final building department inspection and sign off shall be made prior to fire inspection. Contact the community development or planning department of the City of Moreno Valley for zoning information. SITE AND FLOOR PLAN Plans shall be submitted a minimum of 20 business days before occupancy to ensure adequate time to review plans, perform field inspections, and process permit~. Plans shall be accurately scaled or dimensioned diagrams demonstrating compliance with all codes and regulations. Provide 2 copies of the site plan on 8 1/2 x 11 paper. The plan shall include the following: 1. Proximity of the event structure to other buildings, fences, property lines 2. Emergency access roads 3. Fire hydrants 4. Paths of travel from the amusement structure or area to the public way Provide 2 copies of the floor plan on 8 1/2 x 11 paper. The plan shall include the following: 1. Dimensions (total square footage, width/type of exits, aisles or interior exit pathways) 2. Locations of exits, exit signs, and emergency lighting units 3. Location of fire extinguishers 4. Location of electrical panel(s) and light switches 5. Location of smoke detectors and/or the fire alarm panel 6. Normal use of any structures(s) (i.e., warehouse, auditorium, school, church, etc.) 7. Staff and performer positions 8. Queue line design and location 9. Temporary structures, large props, and facades 10. Attraction layout, path of show

FIRE & LIFE SAFETY SYSTEMS 1. An automatic fire sprinkler system is required when the building exceeds 1.000 sq. ft. and the travel distance to an exit exceeds 50 ft. a. Automatic fire sprinkler systems/piping, when provided, shall not be obstructed, altered or used to support any decoration. 2. An automatic smoke detection system is required. a. Automatic smoke detection systems, when provided, shall not be obstructed, altered or turned off. 3. A public address system in accordance with the CBC is required for amusement buildings when the building exceeds 1.000 sq. ft. and the travel distance to an exit exceeds 50 ft. 4. Fire extinguishers shall be a minimum of a 2A:1OBC rating and properly mounted five feet from the floor to the top of the extinguisher. They must be visible and accessible at all times. Travel distance to an extinguisher shall not exceed 75-feet. 5. Decorative material shall not obstruct fire sprinklers, extinguishers, fire alarm "pull stations", fire alarm horns/strobes or any other fire protection equipment inside or outside the building. GENERAL FIRE SAFETY REQUIREMENTS Decorative Materials 1. All decorative material (decorations, drapes, backdrops, and props) shall be either inherently flame retardant and labeled as such or treated with a flame retardant registered with the California State Fire Marshal. Any material not appropriately labeled or certified as fire retardant shall be flame tested and approved. Electrical Hazards 1. Extension cords shall be UL listed, in good condition, and appropriate for their use. 2. Only UL listed power strips with over-current protection shall be used when the number of outlets provided is inadequate. Power strips shall be plugged directly into provided outlets and shall not be plugged into one another in series. 3. All extension cords and power strips shall be adequately protected from foot traffic (i.e., bridged) if paths of travel cannot be avoided.

4. An electrical permit may be required. Contact your local building department for requirements. 5. Flood and strobe lights shall be plugged directly into a wall outlet, a listed multi-plug power strip, or a single listed extension cord. For string lighting, refer to the manufacturer's installation guidelines for the maximum number of string lights that may be connected. When plugging the string lights together, the total amperage of all the light strings shall be calculated to ensure they do not exceed the amperage for the extension cord and circuit. 6. Generators shall be outside and at least 20 feet away from of any structures and shall not interrupt the means of egress. Miscellaneous 1. The maximum occupant load (including all staff and performers) shall be determined during plan review. A sign stating the maximum occupant capacity shall be posted in a visible location near the entrance and staff shall control the flow of patrons so as not to exceed this limit. 2. A written emergency procedure plan shall be provided with the permit application packet. All employees shall be trained in emergency procedures. 3. The emergency procedure plan shall include training of staff and familiarization with the fire alarm tone. Specific personnel shall be designated to turn off all distracting noises (i.e., the sound system) and turn on lights when alerted by either the fire alarm system or otherwise notified of an emergency condition. 4. The event shall be adequately staffed to control the occupant load and assist patrons in exiting should an evacuation become necessary. An appropriate staffing level shall be determined upon review of plans and may be increased at the discretion of the inspector. 5. All emergency staff shall carry flashlights and know the location of all exits, fire extinguishers, light switches, electrical panels, and emergency phones. 6. A fire drill may be required. 7. Phone communication shall be readily available for the purpose of calling 911 in the event of an emergency. 8. Specialized conditions and additional exiting shall be required for structures that are not approved as an assembly.

9. Care and consideration shall be used with respect to smoke generators and smoke detector locations. Use of smoke generators may be restricted if they are determined to be incompatible with smoke detectors. 10. "NO SMOKING" signs shall be provided at the entrance and throughout the attraction. 11. Storage and/or use of flammable or combustible liquids, gasses, and solids are prohibited. 12. Open flame is prohibited. 13. Good housekeeping shall be maintained throughout the attraction and exit pathways. 14. Signage is required at the ticket office and/or entrance of the attraction notifying the public if strobe lights and theatrical smoke effects are used.