FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES

Similar documents
FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES. 1 of 7 11/12/ :26 PM

TG FIRE DRILLS. Office of the Fire Marshal and Emergency Management

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

NFPA Siemens Industry, Inc. All rights reserved. usa.siemens.com/infrastructure-cities

Wayside horn noise investigation

Date Issued: December 14, 2017 Revision: 2.1

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

PROPOSED CHANGE TO THE 2007 FIRE CODE (OFC)

MAINTENANCE OF SMOKE ALARMS GUIDELINE

MAINTENANCE OF FIRE PROTECTION DEVICES WITHIN RESIDENTIAL SUITES OF MULTI-FAMILY BUILDINGS

12/14/2013. Fire alarm and emergency power SPRINKLER HEAD

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST FIRE ALARM SYSTEM INSTALLATION

Community Festival Permit Application - Cypriot Community of Toronto Inc. - Cultural and Wine Festival June 23 and 24, 2007

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

TEN STEP PROCESS PREPARING FIRE SAFETY PLANS

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

BUILDING CODE COMMISSION

Bold items are particular to the City of Euless

VERIFICATION OF FIRE ALARM SYSTEMS

SAFETY CODES COUNCIL ORDER. BEFORE THE FIRE TECHNICAL COUNCIL On June 21, 2012

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

Understanding and Managing Fire Safety in Housing Accommodation

3.1 Introduction. 3.1 Introduction

Compliance Document for New Zealand Building Code Clause F7 Warning Systems Third edition

Florida Building Code Chapter 9 Fire Protection Systems Advanced Course

DIVISION C ADMINISTRATIVE PROVISIONS

Florida Building Code 2010

OFM-TG FIRE SAFETY PLANNING FOR RECYCLING FACILITIES AND WASTE PROCESSING OPERATIONS

Addressing Sound Masking Requirements in the National Fire Alarm and Signaling Code and UL Standards

BUILDING CODE COMMISSION

THIS ORDINANCE ONLY AFFECTS EXISTING FIRE ALARM SYSTEMS.

FIRE & LIFE SAFTEY STANDARD

BUILDING CODE COMMISSION

ISO INTERNATIONAL STANDARD

First Revision No. 82-NFPA [ Section No ] Submitter Information Verification. Committee Statement. 2 of /21/2013 1:03 PM

Applying Performance-based Fire Alarm System Design Part 4

FIRE PREVENTION AND PROTECTION*

East Barnet School I want to learn BOMB EVACUATION PROCEDURES

Approved Document for New Zealand Building Code Warning Systems Clause F7 Third Edition

2004 AUSTRALIAN STANDARDS UPDATE

NOISE STUDY CALEDON EQUESTRIAN PARK TOWN OF CALEDON

British Columbia Building Code 2006 Division B Part 3 Fire Protection, Occupant Safety and Accessibility Section 3.2 Building Fire Safety

Fire Alarm Intelligibility. Chris Nolan

Residential Care Facilities Requirements

RAMBLER PARK FIRE SAFETY INFORMATION

MNEC NFPA 72 WHITE PAPER

This chapter shall be known as the "City of Bayfield Alarm Systems Ordinance."

Type of Fire Alarm Control Panel: System is: Existing OR New If new, provide Electrical Permit Number:

Update all extract references to NFPA documents (including NFPA 72) in Chapter 3 and related annex material to the latest editions.

Changes in NFPA

Recent Revisions and Proposed Key Changes to Fire Code

A COMPARISON OF FIRE ALARM SYSTEM REQUIREMENTS IN THE US AND UK. James R. Lugar Jr., P.E. Rolf Jensen & Associates, Inc. SFPE 2012 Savannah, GA

Proulx, G.; Richardson, J.K. NRCC-45663

Fact File 75. Published Document PD CEN/TS 54-32:2015 Fire detection and fire alarm systems

1. A fire certificate is issued under Section 76 of the Occupational, Safety and Health ActNo. 28 of 2005.

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

p. vi, References p. v, Contents p. 7, References pp. 7-8, References p. 5, Contents p. 7, References p. 9, Definitions p. 13, 1.2.

Mount Laurel Fire Department, Office of The Fire Marshal FIRE WATCH NOTIFICATION

Chubb Monitoring Solutions

Automatic Fire Alarm Association Webinar On Inspection, Testing, And Maintenance Of Fire Alarm Systems

STATE OF MARYLAND DEPARTMENT OF STATE POLICE OFFICE OF THE STATE FIRE MARSHAL

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

S TAR-ORION S OUTH D IAMOND P ROJECT E NVIRONMENTAL I MPACT S TATEMENT APPENDIX A FUNDAMENTALS OF ACOUSTICS

2018 NICET Code Transition Changes

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

Fire Safety Plan Information. For Construction and Demolition Sites

9/23/ :47 AM. Second Revision No NFPA [ New Section after ] Submitter Information Verification. Committee Statement

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

Heating and Comfort Policy. Reviewed April 2014

Sound Performance Rating of Outdoor Unitary Equipment

City of Chilliwack. Bylaw No A bylaw to regulate fire prevention and the protection of life and property

BUILDING CODE COMMISSION

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

FIRE SAFETY PLAN. BUILDING NAME: Pathobiology / AHL BUILDING NUMBER: 089. DATE: 15-August-10 FPO #2

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

FIRE SAFETY PLAN. Ceramics/Sculpture Building 47 Service Rd 1 S Winnipeg, MANITOBA. May / Prepared by: Chris Pancoe

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

B16008-R0-160RC SERIES-U&C 17/1/07 11:13 AM Page Installation Guide

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Variance from Chapter 297, Signs, of the Former City of Toronto Municipal Code Bloor Street West (High Park)

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

FORM MUST BE SIGNED AND RETURNED FOR VENDOR PARTICIPATION

Fire Alarm System Fundamentals

Norfolk Fire Department Fire Prevention & Information

BULLETIN BU/EL Revised August 11, 2015

FIRE ALARM SYSTEMS & 780 CMR. Dave LeBlanc, PE, FSFPE March 17, 2015

Health and Safety Services. Safety Guide 5. Fire drills

Standard for the Installation of Carbon Monoxide (CO) Detection and Warning Equipment

Large Family Daycare Guideline

MCKINNEY FIRE DEPARTMENT FIRE MARSHAL S OFFICE FIRE LANES

THE CORPORATION OF THE VILLAGE OF FRUITVALE BY-LAW NO. 749

2012 OBC Changes. Summary of key changes to Life Safety and Fire Protection Systems for CFAA January 22, 2014

Transcription:

FIRE ALARM AUDIBILITY IN EXISTING RESIDENTIAL OCCUPANCIES Office of the Fire Marshal and Emergency Management

Preface This guideline updates TG-02-1998 published in June 1998. Portions of the guideline have been changed to reflect the current requirements in the Fire Code, O. Reg. 213/07, as amended. August 2016 The reproduction of this guideline for non-commercial purposes is permitted and encouraged. Permission to reproduce the guideline for commercial purposes must be obtained from the, Ontario.

TABLE OF CONTENTS Abstract... 2 1.0 SCOPE... 3 2.0 BACKGROUND... 3 3.0 AUDIBILITY CRITERIA... 3 Option 1: The Fire Alarm Signal Provides At Least 60 dba... 4 Option 2: The Fire Alarm Signal Provides 55-59 dba... 4 Option 3: In-Suite Fire Alarm Signal Devices... 4 Option 4: Conduct An Acoustical Evaluation... 5 4.0 CORRECTIVE ACTION... 5 5.0 ADDITIONAL INFORMATION... 6 Appendix A Sound Level Measurement...A1 1

Abstract The Building Code includes a requirement that the sound pressure level for a fire alarm system in residential sleeping rooms be not less than 75 dba. Although the Fire Code does not prescribe specific sound pressure levels for fire alarm systems in existing buildings, fire safety plan requirements are based on the premise that occupants will be alerted to a fire alarm condition in the building. This document was developed to provide guidance to fire departments and building owners in achieving fire alarm audibility levels consistent with fire safety plan objectives, provide for consistency of application and ensure compatibility with the provisions of the Building Code. The guideline describes the methodology and criteria for the evaluation of existing fire alarm signal levels and the necessary upgrades. OFMEM Section: Technical Services at: 647-329-1100 2

1.0 SCOPE This guideline has been established for the assessment of fire alarm audibility in existing buildings of residential occupancy where there is concern that the signal from the fire alarm system may not be heard intelligibly throughout the floor area in which the audible devices are installed. The guideline provides consistent methodology and criteria for the evaluation of existing alarm signal levels and the necessary upgrades. This guideline does not apply to fire alarm system installations in new construction. Reference should be made to the Building Code for appropriate requirements. 2.0 BACKGROUND The Building Code applies to new construction (including additions), renovations and change of use. The 1997 Building Code adopted a requirement that the sound pressure level in a sleeping room of residential occupancy shall be not less than 75 dba when any intervening doors between the audible signal device and the sleeping room are closed. The 75 dba provision is based on measurements taken in an unfurnished and unoccupied suite. The Building Code also requires that the sound pressure level not exceed 100 dba beyond a prescribed distance from the audible signal device. The Fire Code applies to existing buildings. Currently, the Fire Code does not prescribe specific sound pressure levels in existing buildings with respect to fire alarm audibility. However, Section 2.8 of Division B of the Fire Code requires that a fire safety plan be prepared, approved and implemented in every residential building where the occupant load exceeds 10 persons. The fire safety plan must include procedures that occupants are expected to follow upon hearing the fire alarm. Fire alarm audibility is therefore an inherent component of fire safety planning and evacuation. This document was developed to provide guidance to fire departments and building owners in achieving the intended objective of the Fire Code with respect to fire alarm audibility, provide for consistency of application and ensure compatibility with the provisions of the Building Code. 3.0 AUDIBILITY CRITERIA Compliance with any one of the following four options is deemed to provide an acceptable audibility level in an existing building of residential occupancy: 3

Option 1: The Fire Alarm Signal Provides At Least 60 dba The fire alarm signal measurements in the furnished and occupied building are at or above 60 dba when measurements are taken in accordance with the procedures described in Appendix A of this guideline. Option 2: The Fire Alarm Signal Provides 55-59 dba Where fire alarm signal measurements in the occupied building provide 55-59 dba, ambient sound level measurements must also be taken. Both the fire alarm signal measurements and the ambient sound level measurements shall be taken in accordance with the procedures described in Appendix A. The fire alarm audibility level is considered acceptable provided: a) the fire alarm signal and ambient sound level measurements satisfy the values in Table 1, and b) the fire safety plan includes enhanced fire safety procedures to ensure that all occupants are alerted to an alarm condition in the building. For example, the plan may include provisions for voice messages, floor wardens, a buddy system or telephone network to supplement the fire alarm signals. In no case should the procedures involve actions that would expose occupants to unnecessary risk in the event of a fire. The fire safety plan should also include regular educational programs for the occupants and training for supervisory staff to reinforce the special procedures that have been identified. Fire Alarm Signal Sound Level (dba) Table 1 Maximum Ambient Sound Level (dba) 55 40 56 42 57 44 58 46 59 48 Option 3: In-Suite Fire Alarm Signal Devices Sound pressure level measurements are not required to be taken in any suite where an in-suite audible signal device is installed in conformance with the following conditions: the device is positioned within the suite to allow optimum sound transmission towards the furthest bedroom area from the device and is not more than 6 m (20 ft.) from any bedroom door; 4

there are no intervening doors between the device and the bedroom except the bedroom door; the device is listed as a fire alarm audible signal ; the device acoustical output rating (check the label or instruction sheet) is at least 85 dba; the wiring complies with the Ontario Electrical Safety Code; the device is installed in accordance with standard CAN/ULC-S524 Installation of Fire Alarm Systems ; the device is electrically supervised such that disconnection of the device will cause a trouble condition on the fire alarm system OR provisions are made under the fire safety plan that ensure the in-suite device is inspected to confirm operability prior to occupancy of new tenants. the connection to the fire alarm system is such that disconnection of, or damage to, the in-suite device will not interfere with the operability of devices in other suites or the devices in common areas; and, where the in-suite device is equipped with a silencing switch, it shall be timed to silence the alarm signal in the suite for not more than 10 minutes. (Note: where the device is also used as part of an integrated voice communication system, use of the voice communication shall over ride the silencing feature.) Option 4: Conduct An Acoustical Evaluation A professional engineer specializing in acoustical evaluation shall evaluate the fire alarm signal audibility using octave band measurements of the fire alarm and ambient sound levels. The report must conclude whether or not the fire alarm signals can be heard intelligibly throughout the building with all supporting data and rationalization provided. Alarm sound pressure levels of less than 55 dba should only be permitted where compensating measures are present and are fully documented and acceptable to the Chief Fire Official. 4.0 CORRECTIVE ACTION Where there are residential suites in the building that do not meet the fire alarm audibility acceptability criteria established in this guideline, the owner should take the following corrective actions: Undertake partial upgrading of the fire alarm system to ensure that the audibility in every suite and other portion of the building satisfies one of the options in this guideline. For example, where existing audibility levels in specific suites are inadequate, in-suite devices may be installed only in the 5

affected suites. The owner is advised to discuss proposed changes with the municipal fire and building departments before initiating any partial upgrading. Where the upgrading necessitates replacement of the fire alarm control panel, it is recommended that the audibility levels be upgraded to meet the standard of the Ontario Building Code in force at the time. (Refer also to the explanatory notes in the Appendix to the Ontario Building Code.) Audible signal devices installed to comply with this guideline must not exceed the sound pressure level as prescribed in the Building Code. Where the owner has not taken corrective action to achieve compliance with this guideline and the fire alarm audibility poses a risk to the safety of the occupants, the fire department may issue an order under the Fire Protection and Prevention Act, 1997. 5.0 ADDITIONAL INFORMATION For additional information on this guideline, please contact your local fire department or the at 647-329-1100. 6

of Ontario Appendix A Sound Level Measurement A.1 Sound Level Measuring Devices The sound level meter shall have a measurement range that permits readings as low as 35 dba and shall be calibrated immediately before and after the audibility measurements are taken. The use of a quality meter is important to minimize any measurement errors. ANSI/ASA S1.4-2014/Part 2 / IEC 61672:2-2013 - Sound Level Meters - Part 2: Pattern Evaluation Tests is one standard that can provide guidance on the subject. A.2 Measurement Method The meter is to be held approximately 1.5 metres above the floor and at least 0.5 metres away from hard reflecting surfaces. The meter should also be held as far away as practical from the body of the person taking the measurement. The meter is to be set to the A weighted measurement scale and to the fast response setting. The measurement is to be made in the approximate centre of the most acoustically remote bedroom of the residential suite. The suite door, bedroom door and any intervening doors are to be closed. The bedroom windows are to be closed. The measurements in the bedroom are to be made within a one metre radius of the centre of the room. Sound meters must be used per the manufacturer s instructions. The number and type of measurements taken may vary. Two common methods are described below. Integrating Type Meter An integrating type sound level meter provides calculated Equivalent Sound Level (Leq) readings. The meter takes sample measurements once per second and over a 20 second sample period. Ensure that intermittent noises do not occur during the sample period. Non-Integrating Type Meter A non-integrating type sound level meter requires a series of separate measurements to be taken. It is recommended that four measurements be obtained. The average of the three closest readings should be recorded. Visual averaging of meter readings may be performed in lieu of the above. A1

of Ontario A.3 Selecting The Test Suite The suite selected for the sound measurements should be representative of the lowest fire alarm system audibility. This will generally be the suite with the greatest number of bedrooms, the one located at the far end of a corridor, or the one located in the far corner of the building. Wall to wall carpeting may also significantly reduce fire alarm audibility. It may be necessary to conduct exploratory measurements to identify the suite or suites that represent the lowest audibility levels in the building. The selected suite or suites should be fully furnished at the time of the tests. A.4 Ambient Sound Level Measurements Precautions are necessary to achieve consistent ambient sound level measurements. Temporary or intermittent sound sources such as a flushing toilet, running shower, stereo, television, traffic or exterior construction noise may cause peaks and valleys in sound levels. Ambient sound level measurements should be recorded when these sounds are absent or are at their lowest level. The building HVAC system should be running during the test with the fan speed set on high. Portable air conditioners installed within the suite should be in the off position during the tests. Occupants of the suite under test should refrain from talking or from other activities that may affect the readings. Measurements should be taken during a normal workday period. A2