USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Similar documents
USER S INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

OPERATING INSTRUCTIONS

OWNER S MANUAL HIGH EFFICIENCY VARIABLE SPEED GAS-FIRED FURNACES

Use and Care Manual. MODELS H VAR 1.5 THRU 5 TON 13 Seer Split System Heat Pump REV. 4/06

NOTE TO EQUIPMENT OWNER:

user s information manual

Important Facts You Should Know About Your Heat Pump (602) or (520)

Packaged Air Conditioning Units. Owner s Guide to Operating and Maintaining Your Air Conditioner. This manual should be left with the owner.

MODELS B1PA024, 030 AND 036

AIR CLEANER A GUIDE TO OPERATING AND MAINTAINING YOUR ELECTRONIC. NOTE TO INSTALLER: This manual should be left with the equipment owner.

MODEL 598A TWO-SPEED PLUS CENTRAL AIR CONDITIONER

USER S GUIDE. For all Packaged Systems (Air Conditioners and Heat Pumps)

USER S INFORMATION MANUAL (2,4)SG13B

energy-saving tips for all seasons

Central Air Conditioning System

Fig. 1 - Unit PHD4 and WPH4

CENTRAL AIR CONDITIONER

Bathroom SAVING ENERGY AROUND THE. If you go on vacation, turn the temperature selector to the lowest setting.

ELECTRONIC CONTROL AIR CONDITIONER

GL-DEH Series Portable Dehumidifier Operating Instructions

OIL FURNACE USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

Owner s Information Manual

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

FLOOR CONSOLE/ UNDER CEILING DUAL TYPE. ABT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N

READ AND SAVE THESE INSTRUCTIONS OWNER S MANUAL FOR BYPASS AND FAN POWERED HUMIDIFIERS. Small or Large Bypass 12 Water Saver Bypass 13 Fan Powered 14

AIR CONDITIONER ELECTRONIC CONTROL

READ AND SAVE THESE INSTRUCTIONS

USER MANUAL OLM SERIES WARM AIR OIL FIRED FURNACE

HE360A,B Powered Flow-Through Humidifier

RXIH-AB12A and RXIH-AB17A By-Pass Flow-Through Humidifiers

OPERATING INSTRUCTIONS SMO112 WARM AIR OIL FIRED FURNACE

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Packaged Heat Pumps. Owner s Guide to Operating and Maintaining Your Heat Pump

UNIT MODEL/ POWER SUPPLY VOLTAGE VARIATION AMBIENT AIR ON CONDENSER

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

USER S INFORMATION MANUAL

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

USER S INFORMATION MANUAL

-DUCTED SYSTEM- OPERATING INSTRUCTIONS

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

Owner's Manual TABLE OF CONTENTS

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

NOTE TO INSTALLER: THIS MANUAL MUST BE LEFT WITH THE EQUIPMENT USER.

(602) or (520) Use and Care. Weathertron Heat Pump (EN)

Glass Door Merchandisers GDC10, GDC12F, GDC15, GDC23, GDC24F, GDC40, GDC40F, GDS47, GDC69

Oil Furnace USER S INFORMATION MANUAL FOR THE OPERATION AND MAINTENANCE OF YOUR NEW OIL-FIRED FURNACE

ROTARY CONTROL AIR CONDITIONER

SLIDER CASEMENT AIR CONDITIONER

USER MANUAL SLO / SFLO115 SERIES OIL FIRED WARM AIR FURNACES

OWNER S MANUAL PG9YAA HIGH EFFICIENCY GAS FURNACE ! WARNING SAFETY CONSIDERATIONS

Heat Recovery Ventilators models:

101 EASY WAYS TO SAVE ENERGY AND MONEY.

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

HEAT PUMP A GUIDE TO OPERATING AND MAINTAINING YOUR RESIDENTIAL HEAT PUMP UNIT NOTE TO INSTALLER: THIS MANUAL SHOULD BE LEFT WITH THE EQUIPMENT USER.

UNITARY PRODUCTS GROUP

Portable Dehumidifier

Packaged Gas/Electric Units. Owner s Guide to Operating and Maintaining Your Gas/Electric Unit

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

This document was created with FrameMaker 4.0.4

Model RGAC/SGAC Self Contained Cooling/Gas Heat MODELS RGAC & SGAC - R22 USER'S INFORMATION, MAINTENANCE AND SERVICE MANUAL

Owner s Manual TABLE OF CONTENTS

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002

WINDOW/WALL-TYPE ROOM AIR CONDITIONER

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

USER S INFORMATION MANUAL

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

HEAT & COOL MODEL (REVERSE CYCLE)

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

XL Series Weathertron Heat Pump

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

HE365A,B Powered Flow-Through Humidifier with

Portable Dehumidifier with Internal Pump

CMHC HOME MAINTENANCE CHECKLIST

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

INSTRUCTIONS OPERATING BLUETOOTH CAPACITIVE TOUCH THERMOSTAT MODEL COOL/FURNACE COOL/FURNACE/HEAT PUMP

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Tips To Help Conserve Electricity

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

HOME ENERGY SAVINGS GUIDE

Address of your installer

SU MO TU WE TH FR SA AM PM

User s Information and Installation Instructions

Bathroom SAVING ENERGY AROUND THE. If you go on vacation, turn the temperature selector to the lowest setting.

EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Condensation on Your Windows?

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

- 1 - Updated on 18 March, 2010

HE360 Powered Flow-Through Humidifier

Transcription:

TABLE OF CONTENTS GENERAL INFORMATION............. 2 HOW YOUR HEAT PUMP WORKS.......... 2 SYSTEM OPERATION................. 2 HEATING CYCLE........................ 2 COOLING CYCLE........................ 2 AIDS TO MAXIMUM OPERATING EFFICIENCY......................... 2 HEATING CONSERVATION................ 2 COOLING CONSERVATION............... 3 MAINTENANCE...................... 3 LUBRICATION.......................... 3 FILTER CARE........................... 3 AIR FILTERS............................ 3 REGISTERS............................ 3 CONDENSER COIL...................... 3 BLOWER ASSEMBLY.................... 3 CHARACTERISTICS OF HEAT PUMPS... 3 A CONSTANT HEAT...................... 3 WATER RUN - OFF...................... 4 OUTDOOR COIL DEFROSTING............ 4 BEFORE CALLING A SERVICE PERSON..... 4 USER S, MAINTENANCE and SERVICE INFORMATION MANUAL SINGLE PACKAGE HEAT PUMP UNITS The manufacturer recommends that the User read all sections of this manual and keep the manual for future reference. Tested in accordance with: 66492-YUM-B-0106

Congratulations... on your purchase of our heat pump. This energy efficient unit has been precision designed, manufactured of high-quality materials and has passed many rigorous inspections and tests to ensure years of satisfactory performance. Please read this booklet thoroughly. It will help you understand your heat pump and will tell you how to operate it efficiently and how to obtain the greatest measure of comfort at the lowest operating expense. We appreciate your interest in our products and your decision to purchase our heat pump. Enjoy your comfort. This heat pump has been specially developed and built to meet dual needs of heating and cooling. That s why you can rely on efficient, trouble-free operation. Your system is fully automatic. Set the thermostat and forget it. And it s automatically protected against damage by voltage fluctuations or excessive heating or cooling demands. GENERAL INFORMATION HOW YOUR HEAT PUMP WORKS If your hand is wet and you blow on it, it feels cool because some of the moisture is evaporating and becoming a vapor. This process requires heat. The heat is being taken from your hand, as your hand feels cool. That s what happens with a heat pump. During the cooling cycle, your system will remove heat and humidity from your structure and will transfer this heat to the outdoor air. During the heating cycle, your system will remove heat and humidity from the outdoor air* and will transfer this heat to your structure. Remember that your heat pump doesn t generate much heat, it merely transfers it from one place to another. *This is possible because even 0 F outdoor air contains a great deal of heat. SYSTEM OPERATION Your thermostat puts full control of the comfort level in your structure at your fingertips. Set your thermostat for heating or cooling. Find the temperature that is most comfortable for you, and then leave your thermostat alone. Manually moving the thermostat up or down to extreme settings will not speed up temperature changes. Avoid moving the thermostat up during heating - particularly where a demand type electric meter is installed. This will increase your operating cost substantially. 66492-YUM-B-0106 The Main power to the system must be kept On at all times to prevent damage to the outdoor unit compressor. If necessary, the thermostat control switch should be used to turn the system Off. Should the main power be disconnected or interrupted for 8 hours or longer, DO NOT attempt to start the system for 8 hours after the power has been restored to the outdoor unit. If heat is needed during this 8 hour period, use emergency heat. HEATING CYCLE With the thermostat in the heating position, and outdoor temperature in the range of 20-30 or below, the outdoor unit will generally run 100% of time. When the outdoor air is cool and moist, frost may form on the surface of your outdoor coil. When this frost builds to a certain point, your system will switch to a defrost cycle. Although you may feel cooler air coming from your registers, DO NOT adjust your thermostat. This frost will melt quickly, and your system will return to normal operation automatically. COOLING CYCLE Switch your thermostat to cool. Select a comfortable thermostat temperature setting, typically between 75 and 80 degrees. Comfort sensations vary with individuals.the lower the indoor temperature desired, the greater the number of hours your unit must operate. Set your thermostat 2 or 3 F below normal several hours before entertaining large groups during hot weather. People give off considerable heat and moisture. On an extremely hot day, the indoor temperature may rise 3 to 6 F above the thermostat setting. Properly selected equipment does not have the capacity to maintain a constant indoor temperature during this peak load. Over-sizing your system to handle this peak load isn t practical because the over-sized system would operate much less efficiently at all other conditions. AIDS TO MAXIMUM OPERATING EFFI- CIENCY HEATING CONSERVATION For the most efficient operation, keep storm windows and doors closed all year long. They not only help to insulate against heat and cold, but they also keep out dirt, pollen and noise. Closing drapes at night and keeping fire place dampers closed when necessary, will help you to retain the air you have already paid to heat. 2 Unitary Products Group

COOLING CONSERVATION To comfortably cool your home, your heat pump must remove both heat and humidity. Don t turn your system off even though you will be away all day. On a hot day, your system may have to operate between 8 and 12 hours to reduce the temperature in your home to a normal comfort level. Keep windows closed after sundown. While the outdoor temperature at night may be lower than indoors, the air is generally loaded with moisture which is soaked up by furniture, carpets and fabrics. This moisture must be removed when you restart your system. The hotter the outside temperature, the greater the load on your system. Therefore do not be alarmed when your system continues to run after the sun has set on a hot day. Heat is stored in your outside walls during the day and will continue to flow into your home for several hours after sunset. Use your kitchen exhaust fan when cooking. One surface burner on High requires one ton of cooling. Turn on your bathroom exhaust fan while showering to remove humidity. You can also help your system in the summer by closing drapes or blinds and lowering awnings on windows that get direct sunlight. MAINTENANCE Prior to any of the following maintenance procedures, shut off all power to the unit. In order to insure long and trouble free service from your system, we recommend periodic inspection, cleaning, lubrication and adjustment by your installing Dealer/Contractor. Be sure to ask about this service. For those buildings with in-house maintenance, please follow the instructions listed below to care for your system. LUBRICATION Both the indoor blower motor and outdoor fan motor are permanently lubricated and require no maintenance. FILTER CARE Filters must always be used and must be kept clean. When filters become dirt laden, insufficient air will be delivered by the blower, decreasing your units efficiency and increasing operating costs and wear-andtear on the unit and controls. AIR FILTERS Single phase units are shipped without a filter and is the responsibility of the installer to place a high velocity filter into the return air duct system. If an economizer or outdoor air accessory is used, install a filter/frame kit (1FF0114). See Figure 1. The filter rack and filters are standard on three phase units. Filters should be checked monthly especially since the unit is used for both heating and cooling. You must have high velocity permanent filters. High velocity permanent filters may be removed for cleaning. Remove filters, vacuum or wash with a stream of water directly from a faucet or hose. Allow filters to dry and replace. High velocity permanent filters should last for many years. However, if they ever need replacing, they must be replaced with the same size and type. NOTE: Filters must be installed with Air Flow arrows pointing inward toward the indoor coil. REGISTERS Supply and return air registers must be open when the unit is in operation. Furniture must not block airflow in or out of the registers. CONDENSER COIL An annual check and cleaning of the outdoor coil should be done. Clean any debris and dirt from the outside coil face with a brush being careful not to damage the fins. If extremely dirty, a hose can be used to wash the coil from the inside out while brushing a soapy solution on the outside. BLOWER ASSEMBLY Even with good filters properly in place, blower wheels and motors will become dust laden after long months of operation. The entire blower assembly should be inspected annually. If the motor and wheel are heavily coated with dust, they can be brushed and cleaned with a vacuum cleaner. CHARACTERISTICS OF HEAT PUMPS A CONSTANT HEAT Heat pumps have a noticeably cooler supply air temperature than furnaces. The common practice of oversizing furnaces contributes to an "off-and-on-again" operation with short blasts of hot supply air. The heat pump system is sized more closely to the heating needs of your home. Heat is supplied at a lower temperature over a longer period of time to provide a more constant heat, and it may give you the impression that your system "never stops running". Unitary Products Group 3

WATER RUN - OFF During the heating cycle, you may notice water running off the outdoor coil. Moisture from the air is condensed on the outside surface of the coil where it gathers and runs off. No need for alarm, your unit has not sprung a leak! OUTDOOR COIL DEFROSTING At certain outdoor conditions (low temperature, high humidity), frost may build up on the coil of the outdoor unit. In order to maintain heating efficiency, the system will automatically defrost itself. will only last for a few minutes. When the defrost cycle is completed, the system will automatically switch back to heating. Electric heat is automatically energized to maintain comfort during defrost. BEFORE CALLING A SERVICE PERSON Check thermostat setting and insure thermostat is calling for heat or cooling. Check thermostat for lint, etc. Check fuses or circuit breakers Check filters for excessive dust accumulation Water vapor rising from the outdoor unit is normal and is an indication of proper operation. The vapor cloud DUCT SIDE CONTROL BOX SIDE INDOOR COIL HORIZONTAL FILTER CONTROL BOX VERTICAL FILTER INDOOR COIL FIGURE 1 - FILTER ACCESS 4 Unitary Products Group

TABLE 1: TROUBLE SHOOTING GUIDE NO HEAT PROBLEM NOT ENOUGH HEAT - OUTDOOR UNIT NOT RUNNING NO COOLING ELECTRICAL POWER INTERRUPTION (ice, snow, or wind storms) Check thermostat for proper setting Check circuit breaker and fuses. Check filters. Call qualified service man. Check thermostat for proper setting. Check circuit breaker and fuses. Switch thermostat to Emergency Heat position. Call qualified service man. Check thermostat for proper setting. Check circuit breaker and fuses. Check filters. Call qualified service man. *There will be no heat available until power is re-established REPLACEMENT PARTS CORRECTION Procedure Heating Season: 1. Switch thermostat to Emergency Heat.* 2. Leave Emergency Heat on for at least 12 hours after electrical power is re-established. 3. Switch thermostat back to Heating or Auto. Procedure Cooling Season: 1. Switch thermostat to Off position. 2. Do not switch to Cooling or Auto until electrical power has been re-established for 4 hours. SINGLE PACKAGE HEAT PUMP (2 TON) SINGLE PACKAGE HEAT PUMP (3.5 TON) RENEWAL PARTS FORM No. RESPECTIVE MODEL No. RENEWAL PARTS FORM No. RESPECTIVE MODEL No. 035-20210-000-A-0604 035-20296-000-A-0206 B1HZ024*** B1HX024*** 035-20210-000-A-0604 B1HZ042*** SINGLE PACKAGE HEAT PUMP (2.5 TON) SINGLE PACKAGE HEAT PUMP (4 TON) 035-20210-000-A-0604 B1HZ030*** 035-20210-000-A-0604 035-20296-000-A-0206 B1HZ048*** B1HX048*** SINGLE PACKAGE HEAT PUMP (3 TON) SINGLE PACKAGEHEAT PUMP (5TON) 035-20210-000-A-0604 035-20296-000-A-0206 B1HZ036*** B1HX036*** 035-20210-000-A-0604 035-20296-000-A-0206 B1HZ060*** B1HX060*** Unitary Products Group 5

6 Unitary Products Group

NOTES Unitary Products Group 7

NOTES Subject to change without notice. Printed in U.S.A. Copyright 2006 by Unitary Products Group. All rights reserved. 66492-YUM-B-0106 Supersedes: 66492-YUM-A-0704/035-20184-000-A-0704 Unitary 5005 Norman Products York OK Group Drive 73069