TABLE OF CONTENTS ERSQ-AAY1

Similar documents
TABLE OF CONTENTS RMXS-E8V1B

EEDEN technical data ERHQ AA

TABLE OF CONTENTS ERHQ BAV3

EEDEN technical data ERHQ AA. Altherma. Altherma

technical data air conditioning systems RMXS-E7V3B1 Super multi plus Split Sky Air

Heating. Technical Data EEDEN ERRQ-AY1

Heating. Technical Data. Daikin Altherma low temperature split EEDEN ERLQ-CW1

EEDEN technical data. air conditioning systems RZQS71-140C7V1B. Split Sky Air

EEDEN technical data. air conditioning systems RZQS-DV1. Split Sky Air

Air Conditioners. Technical Data FBQ-C

technical data air conditioning systems RZQ B8W1B Split Sky Air

technical data air conditioning systems Indoor Units FBQ-C7VEB

Service Manual. Air Cooled Refrigeration Condensing Unit

EEDEN technical data. air conditioning systems RZQ-DV1. Split Sky Air

TABLE OF CONTENTS EDLQ AA6V3

Air Conditioning Technical Data RZASG-MV1

Air Conditioners. Technical Data. Heating only hydrobox for VR V HXHD-A

EEDE06-9. technical data. Altherma ERYQ A EKHBH007A / EKHBX007A EKSWW

technical data air conditioning systems RZQ C7Y1B Split Sky Air

TABLE OF CONTENTS EBLQ01-016AA6V3

Air Conditioning Technical Data RZAG-MV1

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

technical data air conditioning systems RR-B8V3B_RR-B8W1B Pair, Twin, Triple Application Split Sky Air

Air Conditioning. Technical Data. VRV IV heat recovery EEDEN14-200_4 REYQ-T

Air Conditioning Technical Data AZAS-MY1

EEDEN technical data. Altherma ERHQ AA EKHBH007AC / EKHBX007AC EKSWW

EDUS D Engineering Data RXYQ-TAYCU, 575 V. Heat Pump 60 Hz

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EDHQ-BB6V3

Heating. Technical Data. Daikin Altherma low temperature monobloc EEDEN EBLQ-BB6W1

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

General Outline: Altherma

Air Conditioning. Technical Data. Pair, Twin, triple, double twin EEDEN RZQ-C

EEDEN technical data. Altherma ERHQ AD EKHBH/X008AA ERHQ AA EKHBH/X016AB EKHWS(U) EKSOL

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Air Conditioning. Technical Data. High temperature hydrobox for VRV EEDEN HXHD-A8

TABLE OF CONTENTS EKHTS-A

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

TABLE OF CONTENTS EKHWS

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

EEDEN technical data EKSOLHWAV1

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

Air Conditioning. Technical Data EEDEN AZQS-BV1

technical data air conditioning systems Indoor Units FCQ-C8VEB

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

EEDEN technical data. Altherma TM

Air Conditioners. Technical Data RZQG-L

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

technical data air conditioning systems FHYKP-B Ceiling Mounted Corner Cassette Split Sky Air

Digital Inverter 4 series 8 & 10HP

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

DESIGN MANUAL Version 1.0

technical data air conditioning systems FH(Y)B-FK7 Concealed Ceiling Unit Split Sky Air

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

Air Conditioning. Technical Data. VRV IV S-series compact heat pump EEDEN RXYSCQ-TV1

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

DACA-EEDEN technical data. Engineering Data. DaikinAltherma

PUHZ-SHW140YHA PUHZ-SHW230YKA

SiENBE Service Manual. RXYSQ4-5-6PA7Y1B, PA7V1B R-410A HEAT Pump 50Hz

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

Air Conditioners. Technical Data FTXS-G

AIR CONDITIONERS MODELS PQHY-P650YSHM-A PQHY-P700YSHM-A PQHY-P750YSHM-A PQHY-P800YSHM-A PQHY-P850YSHM-A PQHY-P900YSHM-A DATA BOOK

REYQ72-456TTJU REYQ72-456TYDN R-410A

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

3.2 E1 Outdoor Unit PCB Abnormality E4 Actuation of Low Pressure Sensor E5 Compressor Motor Lock 3 52

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

EDUS Heat Pump - D-Series

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

MUH-24RV - MSH-30RV -

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

PURY-P200YMF-C, PURY-P250YMF-C CONTENTS

Compact 4-way Cassette ( ) Type

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

SERVICE MANUAL MUZ-GB50VA - E1 MUZ-GB50VA - E2 MUZ-GB50VA - E3 OUTDOOR UNIT. No. OB455. Models HFC

Refrigeration / Air Conditioning Systems Circuit Drawings. Student Resource Package No: NR 24

Air Conditioning. Technical Data EEDEN RZQSG-L(3/8)V1

Air Conditioning. Technical Data EEDEN RZQG-L8/7V1

SiENBE REYQ8-48PY1B R-410 Heat Recovery 50HZ

AIR-CONDITIONER SERVICE MANUAL

11. WALL MOUNTED TYPE PACKAGED AIR CONDITIONER Split system, Air cooled cooling only type

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Water cooled VRV IV W-series

ICC COOLING STORAGE UNIT ICC/ICU SYSTEM

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

TECHNICAL DATA & SERVICE MANUAL

DESIGN & TECHNICAL MANUAL

Heating Nom. dba 50 (5) 50 (5) 50 (5) Cooling Nom. dba 50 (5) 50 (5) 50 (5) Anti freeze heater (optional) W Expansion vessel Volume l 6 6 6

Transcription:

Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 TABLE OF CONTENTS ERSQ-AAY1 1 Features............................................................ 6 2 Specifications...................................................... 7 Nominal Capacity and Nominal Input............................... 7 Technical Specifications............................................ 7 Electrical Specifications............................................. 8 3 Capacity tables.................................................... 9 Heating capacity tables............................................. 9 Dimensional drawing & centre of gravity....................... 50 Dimensional drawing................................................ 50 Centre of gravity.................................................... 51 5 Piping diagram..................................................... 52 6 Wiring diagram..................................................... 53 Wiring diagram...................................................... 53 7 Sound data......................................................... 5 Sound pressure spectrum........................................... 5 Sound power spectrum............................................. 55 8 Operation range................................................... 56 Heating Daikin Altherma 5

h t n l u r g n o n i o i - kd t it a au e Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 1 Features i A1 Y A A Q S R OE D H High temperature application: up to 80 C without electric heater Three phase large capacity outdoor unit Operation of unit guaranteed down to -20 C Cost effective alternative to a fossil fuel boiler Low energy bills and low CO 2 emissions Easy to install Total solution for year round comfort 1 6 Heating Daikin Altherma

Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 2 Specifications 2-1 Nominal Capacity and Nominal Input ERSQ011AAY1 ERSQ01AAY1 ERSQ016AAY1 For combination indoor units + outdoor units Indoor Units EKHBRD011AAY1 EKHBRD01AAY1 EKHBRD016AAY1 Condition 1 Heating capacity Nominal kw 11 1 16 Heating PI Nominal kw 3.57.66 5.57 COP Nominal 3.08 3.00 2.88 Condition 2 Heating capacity Nominal kw 11 1 16 Heating PI Nominal kw 2.61 3.55.31 COP Nominal.22 3.9 3.72 Condition 3 Heating capacity Nominal kw 11 1 16 Notes Heating PI Nominal kw.0 5.65 6.65 COP Nominal 2.50 2.8 2.1 Condition 1: EW: 55; LW: 65; dt: 10; ambient conditions: 7DB/6WB Condition 2: EW: 30; LW: 35; dt: 5; ambient conditions: 7DB/6WB Condition 3: EW: 70; LW: 80; dt: 10; ambient conditions: 7DB/6WB 2-2 Technical Specifications ERSQ011AAY1 ERSQ01AAY1 ERSQ016AAY1 Casing Colour Daikin white Material Painted galvanised steel plate Dimensions Unit Height mm 1,35 Width mm 900 900 900 Depth mm 320 320 320 Packing Height mm 1,52 Width mm 980 980 980 Depth mm 20 20 20 Weight Unit kg 120 120 120 Packed Unit kg 130 130 130 Packing Material Wood EPS Cardboard Weight kg 8 8 8 Heat Exchanger Dimensions Length mm 857 857 857 Tube type Nr of Rows 2 2 2 Fin Pitch mm 2 2 2 Nr of Passes 10 10 10 Face Area m² 1.131 1.131 1.131 Nr of Stages 60 60 60 Hi-XSS Fin Type Non-symmetric waffle louvre Treatment Corrosion resistant Fan Type Propeller Quantity 2 2 2 Discharge direction Horizontal Motor Quantity 2 2 2 Model Brushless DC motor Output W 70 70 70 Drive Direct drive Compressor Quantity 1 1 1 Motor Type Hermetically sealed scroll compressor Starting Method Direct on line Motor Crankcase Heater Quantity 1 1 1 Output W 33 33 33 Operation Range Heating Min CWB -20-20 -20 Max CWB 20 20 20 Domestic hot water Min CDB -20-20 -20 Max CDB 35 35 35 Sound Level (nominal) Heating Sound Power dba 68 69 71 Sound Pressure dba 52 53 55 2 Heating Daikin Altherma 7

Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 2 Specifications 2 2-2 Technical Specifications ERSQ011AAY1 ERSQ01AAY1 ERSQ016AAY1 Refrigerant Type R-10A Charge kg.5.5.5 Control Expansion valve(electronic type) Nr of Circuits 1 1 1 Refrigerant Oil Type Daphne FVC68D Charged Volume l 1.5 1.5 1.5 Piping connections Liquid (OD) Quantity 1 1 1 Defrost Method Defrost Control Capacity Control Method Safety Devices Type Flare connection Diameter (OD) mm 9,52 Gas Quantity 1 1 1 Type Flare connection Diameter (OD) mm 15,9 Drain Quantity 3 3 3 Diameter (OD) mm 26x3 Piping Length Minimum m 3 3 3 Maximum m 50 50 50 Equivalent m 63 63 63 Chargeless m 10 10 10 Additional Refrigerant Charge kg/m see installation manual Installation height difference Heat Insulation Maximum m 30 30 30 Both liquid and gas pipes Reverse cycle Sensor for outdoor heat exchanger temperature Inverter controlled High pressure switch Fan motor thermal protector Inverter overload protector PC board fuse Standard Accessories Item Installation manual Quantity 1 1 1 High pressure side Design pressure bar 0 0 0 Notes See operation range drawing 2-3 Electrical Specifications ERSQ011AAY1 ERSQ01AAY1 ERSQ016AAY1 Power Supply Name Y1 Current Phase 3~ Frequency Hz 50 50 50 Voltage V 380-15 Voltage range Minimum V 32 Maximum running Current Maximum V 0 Heating A 13,5 Recomended fuses A 16 16 16 Wiring connections For Power Supply Quantity G Power Supply Intake For connection with indoor Remark Select diameter and type according to national and local regulations Quantity 2 2 2 Remark F1+F2 Both indoor and outdoor unit 8 Heating Daikin Altherma

3 Capacity tables 3-1 Heating capacity tables ERSQ-AY1 Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 Capacity table Peak LW [ C] LW [ C] LW [ C] LW [ C] LW [ C] Ta[ CDB] 5 55 65 75 80 [ CDB] HC PI HC PI HC PI HC PI HC PI Symbols HC Heating capacity [kw] PI Power input [kw] LW Leaving water temperature EW Entering water temperature Conditions - nt (Leaving water temperature - Entering water temperature) - Piping length R10A Refrigerant piping length = 5m - No pump power input is included - if Ta < 3 C and unit has bottom plate heater, 95 W has to be added to PI value - Ta < 0 C: RH=75% - Ta > 0 C: RH=85% flowrate [l/min] *011* *01* *016* nt = 15 C 10,5 13, 15,3 3 nt = 10 C 15,8 20,1 22,9 nt = 5 C 31,5 0,1 5,9 Integrated LW [ C] LW [ C] LW [ C] LW [ C] LW [ C] Ta[ CDB] 5 55 65 75 80 [ CDB] HC PI HC PI HC PI HC PI HC PI 3TW5882-1C Heating Daikin Altherma 9

Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 Dimensional drawing & centre of gravity - 1 Dimensional drawing ERSQ011-016AA Hole for anchor bolt -M12 1. Gas pipe connection J15.9 flare 2. Liquid connection pipe "9.5 flare 3. Service port (in the unit). Electronic connection and grounding terminal MS (in switch box) 5. Refrigerant piping intake 6. Power supply wiring intake (knock hole J3) 7. Control wiring intake (knock hole J27) 8. Drain outlet TW5791-1 50 Heating Daikin Altherma

Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 Dimensional drawing & centre of gravity - 2 Centre of gravity ERSQ011-016AAY1 Position of foundation bolt TW5879-6 Heating Daikin Altherma 51

5 Piping diagram Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 ERSQ011-016AA Electronic expansion valve (Y3E) Double pipe heat exchanger Electronic expansion valve (Y1E) Filter Pressure regulating valve Heat exchanger Fan Filter 5 Compressor (MC1) Low pressure sensor (S1NPL) Solenoid valve (Y2S) Filter Capillary tube -way valve (Y1S) High pressure switch (S1PH) Filter High pressure sensor (S1NPH) Capillary tube Service port Solenoid valve (Y3S) R1T: Ambient thermistor R2T: Discharge thermistor R3T: Suction thermistor (1) RT: Coil thermistor R5T: Suction thermistor (2) R6T: Subcool thermistor R7T: Liquid thermistor (1) R8T: Liquid thermistor (2) Accumulator Heating Defrost Stop valve (with service port on field piping side J 7.9mm flare connection) Check valve Flare connection Screw connection Flange connection Pinched pipe Spinned pipe 3TW5875-1 52 Heating Daikin Altherma

6 Wiring diagram 6-1 Wiring diagram ERSQ-AY1 Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 Power supply 3N 380-15V 50Hz Reactor terminal position Compressor terminal position Only for bottomplate heater option Indoor BPH Indoor F1, F2 Detail of El. Compo. Box Layout of M1F,M2F,M1C,L13-3R, El.Comp.Box El. Compo. Box A1P A2P A3P BS1 BS5 Printed circuit board Printed circuit board (INV) Printed circuit board (Noise filter) Push button switch (Mode, set, return, test, reset) Capacitor DIP switch Crankcase heater C1-C3 DS1 E1HC F1H Fuse (A 31.5A 500V) F2U Fuse (A 31.5A 500V) F3U Fuse (T 6.3A / 250V) FU Fuse (T 6.3A / 250V) F5U Fuse (T 6.3A / 250V) F6U Fuse (T 5.0A / 250V) F7U Fuse (T 1.0A / 250V) F8U Fuse (F 1.0A / 250V) E7H Bottom plate heater HAP (A1P) Pilot lamp (Service monitor-green) HAP (A2P) Pilot lamp (Service monitor-green) H1 8P(A1P) Pilot lamp (Service monitor-orange) (H2P)Prepare, Test --------- Flickering Malfunction Detection -- Light up K1M-K2M Magnetic contactor K1R (A1P) Magnetic relay (Y1S) K2R (A1P) Magnetic relay (Y2S) K3R (A1P) Magnetic relay (Y3S) KR (A1P) Magnetic relay (E1HC) K5R (A2P) Magnetic relay L1R L3R Reactor LR Reactor (For outdoor fan motor) M1C Motor (Compressor) M1F Motor (Upper fan) M2F Motor (Lower fan) PS Power supply R1 R2 Resistor R1T Thermistor (Air) R2T Thermistor (M1C Discharge) R3T Thermistor (Suction 1) RT Thermistor (Subcool) R5T Thermistor (Suction 2) R6T Thermistor (Coil) R7T Thermistor (liquid 1) R8T Thermistor (liquid 2) R9T Thermistor (Power module) S1NPH Pressure sensor(high) S1NPL Pressure sensor(low) S1PH Pressure switch (high) V1R V2R Power module V3R Diode module X1M Terminal strip X2M Terminal strip (Control) Y1E Expansion valve (Main) Y3E Expansion valve (Subcool) Y1S way valve Y2S Solenoid valve (hot gas) Y3S Solenoid valve (U/L circuit) Z1C 7C Noise filter Z1F 3F Noise filter Q1DI Field earth leakage breaker(300ma) 6 Notes: 1 This wiring diagram only applies to the outdoor unit 2 g: Field wiring 3 D : Terminal F : Fixed connector Movable connector R : Protective earth (screw) : Connector p : Noiseless earth G : Terminal strip When using the option adaptor, refer to the installation manual 5 Refer to the operation caution label (on back of front plate) how to use BS1 BS5 and DS1 switch. 6 When operating, do not short circuit for protection device. (S1PH) 7 Colors BLU: blue, BRN: brown, GRN: green, RED: red, WHT:white 8 When using the central control system, connect outdoor-outdoor transmission F1-F2. 9 : Option Front Arrow view Outer shell 2TW5876-1C Heating Daikin Altherma 53

7 Sound data 7-1 Sound pressure spectrum Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 Sound pressure level (db) ERSQ011AAV1 ERSQ011AAY1 HEATING Sound pressure level (db) ERSQ01AAV1 ERSQ01AAY1 HEATING Sound pressure level (db) ERSQ016AAV1 ERSQ016AAY1 HEATING 7 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: 1 Data is valid at free field condition (measured in a semi-anachoic room) 2 dba = A-weighted sound power level (A-scale according to IEC) 3 Reference acoustic pressure 0dB = 20µPa If sound is measured under actual installation conditions, the measured value will be higher due to environmental noise and sound reflections. Measuring location (discharge side) 3TW5877-1 5 Heating Daikin Altherma

7 Sound data 7-2 Sound power spectrum Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 ERSQ011AAV1 ERSQ011AAY1 HEATING ERSQ01AAV1 ERSQ01AAY1 HEATING ERSQ016AAV1 ERSQ016AAY1 HEATING Sound power level (db) Sound power level (db) Sound power level (db) 7 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band center frequency (Hz) Notes: 1 dba = A-weighted sound power level (A-scale according to IEC) 2 Reference acoustic pressure 0dB = 20µPa 3 Measured according to ISO 37 3TW5877-2 Heating Daikin Altherma 55

Daikin Altherma High Temperature Outdoor units ERSQ-AAY1 8 Operation range Space heating mode Domestic hot water mode EKHBRD011-016AA ERSQ011-016AA EKHTS-A DHW operation Startup area Continuous heating operation 8 Continuous heating operation Startup area Domestic hot water operation operation possible, but no guarantee of capacity Tank temperature ( C) operation possible, but no guarantee of capacity ERRQ*(V1/Y1) units include special equipment (insulation, heater sheet,...) to ensure good operation in areas where low ambient temperature can occur together with high humidity conditions In such conditions ERQS*5V1/Y1) models may experience problems with severe ice build up on the aircooled coil. In case such conditions are expected the ERRQ*(V1/Y1) must be installed instead. These models contain countermeasures to prevent freeze up. Can be adjusted by field setting 3TW5883-1B 56 Heating Daikin Altherma