User s Information Guide

Similar documents
User s Information Guide

Air Handlers - Vertical, Horizontal and Convertible

READ AND SAVE THESE INSTRUCTIONS HUMIDIFIERS USER S INFORMATION GUIDE. For Models *HUMD200ABM00B *HUMD300ABA00B *HUMD500APA00B

ACONT600AF11MA/ACONT602AF22MA Programmable Comfort Control

Use and Care. Outdoor Unit Available in French Canadian (FC)

Programmable Heat-Pump Thermostat TAYSTAT 540

TCONT402AN32DA. Owner s Manual. Comfort Control XR402. Pub. No Fan Mode. Filter/OD

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

lectronic Air Cleaner

Outdoor Unit

User s Information Guide

(602) or (520) Use and Care. Weathertron Heat Pump (EN)

Use and Care TRAIIE"

Energedry Eliminator 52K

SOLO OWNERS MANUAL, OPERATING INSTRUCTIONS & INSTALLATION INSTRUCTIONS

READ MANUAL BEFORE OPERATING SYSTEM Read the owner s manual thoroughly before operating to ensure the most efficient use of the system.

Energedry Elite Eliminator Pest Control Electric Heat System

7-Day. Digital Thermostat. residential. & 2-cool

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

Owner s Manual. Operating Instructions The Controls on Your Dehumidifier Care of Product

AirInstinct Air Purifier

DUST FREE CARBON Whole House Air Purifier

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

Alen T500 HEPA Air Purifier

Fan Speed. Auto Swing. Timer. Power. Mode. Fan. Only. Saver. Temp. Dry. Fan. Speed. Auto Swing. Timer. Power. Mode. Saver. Only. Temp.

TURBO Hooded Fans. Installation & Operator s Manual (14, 18, & 24 Direct Drive)

Residential Duct Mount Builder s Box Media Air Cleaner

Energedry Elite 52K. Operations Manual. Pest Control Electric Heat System. For Professional use only. EPA EST. No AZ-001

Models & Replacement Filter Information

IMpORTANT SAFETy INSTRUcTIONS

Paralda Air Purifier USER MANUAL

Radial 8 Heater For Professional use only

FLCH4R Garage and Utility Electric Heater

Portable Air Cleaner. Owner s Manual. The Science of Clean Air READ AND SAVE THESE INSTRUCTIONS. For Model 1606X Series Air Cleaner JULY

12,000 BTU Portable Air Conditioner PE3-12R-03. Model No. PE3-12R Soleus Air International

Owner s Manual. Important Safety Information. Operating Instructions The Controls on Your Air Conditioner Care of Product

Quest Power Electric Heat EHS 31 Pro

Owner s Manual. 5+2 Day Programmable Digital Thermostat

Installation Instructions

Owner s Manual Phoenix FireBird

Installer's Guide. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 18-EB25D1-1

5) Do not start or stop the unit by inserting or pulling out the power plug.

MAN AUTO IMPORTANT INSTRUCTIONS PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING APPLIANCE

I Cautions & Warnings

Quest Power Electric Heat EHS 62 Pro

ELECTRIC FIREPLACE OWNER S MANUAL

5+2 Day. up to HEAT COOL

Owner s Guide. Thank you for purchasing your new Eureka vacuum! Important instructions.

EVAPORATIVE COOLER W

Humidity Module OWNER S MANUAL. Complete Control from

CANISTER VACUUM MODEL SC-19

With Remote Control. English. Model

TrueClean ToteCleaner

Replacement Filter Information

11,000 BTU Portable Air Conditioner with dehumidifier & Fan PE4-11R-03 Operating Instructions. Model No. PE4-11R Soleus Air International

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

INSTRUCTION MANUAL P Heating and 1 Cooling

READ AND SAVE THESE INSTRUCTIONS

TrueClean ToteCleaner

Portable Air Conditioner and Heater With Heat Pump Technology Operating Instructions. Model No.: PH3-12R-03 Reference No.: KY2-34

Models 30755, & (remote included) Replacement Filter Information

With Remote Control. English

IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE SAFETY INSTRUCTIONS BEFORE USING THIS AIR PURIFIER

Alen A350 HEPA Air Purifier USER MANUAL

Portable Air Conditioner 6,000 BTU 8,000 BTU 10,000 BTU


SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

CR13000-PAC OWNER S MANUAL. Portable Air Conditioner. PORTABLE AIR CONDITIONER with HEAT PUMP. Operating and Servicing Instructions

5+2 DAY. Digital Thermostat. residential. & 1-cool. up to 2-heat PROGRAMMABLE THERMOSTAT. Venstar Inc. 05/08

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

THARRINGTON OIL FIRED ROOM HEATERS MODELS 5135, 5160, R35, 10R60, 13R75 FEATURES SAFETY NOTICE

Garment Steamer Model SC620

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

FAN COIL NON-PROGRAMMABLE DIGITAL THERMOSTAT

Description of the vacuum

Operating Instructions

DUAL VOLTAGE REFRIGERATORS 220/240 VOLTS AC AND 12/24 VOLTS DC INSTALLATION AND OWNER S MANUAL

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

Model No.: PS08-01 PS10-01 Ref: KY80 KY100

Atrix ERGO PRO Backpack Vacuum

5+2 DAY. OWNER S MANUAL Venstar Inc. 05/08

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Owner s Manual MODEL 8555

Instruction Leaflet 99.97% TRUE HEPA AIR PURIFIER. pure indoor living MODEL: BAP925-CN. Replacement filters: A1230H and A1260C

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

DXP-PB-2-8 Manual 8 Par-Bake & Form Dough Press

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

IMPORTANT INSTRUCTIONS

(The chances are you re never going to read me) Owner s Manual HEAVY DUTY SHD-1T.

INSTRUCTION MANUAL. Remember to register your air purifier at: Multi-Tech 8500 Air Purifier

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

Portable Air Conditioner with Heat Pump Technology Operating Instructions. Model No.: HCB-P13HP-D. Reference No.: BPD13HP V140217

Operator s Manual. IP-100 Immersion Probe Cooler

TURBO Fiberglass Cone Fan and Grill Fan 48'' Belt Drive. Installation & Operator s Instruction Manual

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER DEUMIDIFICATORE DESHUMIDIFICADOR DESUMIDIFICADOR

16 Stand Fan with Remote Control Model No: FS3-40R-30

Installation Instructions

Transcription:

32-5042- 02 User s Information Guide Energy Recovery Ventilator (ERV) *ERVR100A9P00A *ERVR200A9P00A *ERVR300A9P00A *May be "A" or "T" 32-5042-02

GENERAL INFORMATION Understand the signal words. WARNING, AND CAUTION. These words are safety alert words. WARNING indicates hazards which could result in personal injury or death. CAUTION is used to indicate unsafe practices which could result in minor injury or property damage.! WARNING Disconnect Power Before Servicing. Failure to follow the electrical servicing instruction may cause Personal Injury or Death.! WARNING Do Not Use This Unit if Any Part Has Been Under Water. Immediately Call A Qualified Service Technician To Inspect The ERV and To Replace Any Part of The Control System Which Has Been Under Water.! CAUTION PERSONAL INJURY HAZZARD Failure to follow filter service instructions may cause personal injury. The access door swings down when unit is installed overhead. Carefully hold the access door while unlatching and lowering. The door should be removed prior to performing filter service. FILTER SERVICE. A Clean Filter Saves Money. When the ERV provides fresh outdoor air into your home and exhausts indoor air to the outside, dust and dirt particles build up on the air filters. Excessive accumulation can block airflow, decreasing the ERV s performance and increase energy usage. To maintain top performance be sure to clean or replace the ERV filters according to the instructions in this manual. Clean filters every three months when the unit is in regular use or as needed to keep them clean. How to remove and clean your filter: 1. Release cam latches and carefully swing access door open. The access door may be removed for ease of service by sliding the access door off. Use caution when removing door 2. Remove the filter retainer springs. Pull the filters out. See Figure 1. 3. Vacuum filters off with a hose attachment. 4. Re-install filters and retainer spring 5. Re-install cover, and fasten cam latches. FILTER SERVICE NOTES A) The filters should be replaced after they have been cleaned several times. Contact your installing dealer for service and replacement filters. Replacement filter model numbers are as follows: Model Filter # *ERVR100 BAYFLT10A1010A *ERVR200 BAYFLT20A1020A *ERVR300 BAYFLT20A1020A B) Filters may be cut from a sheet or roll of ¾ - 1 firm, spun polyester filter hog hair media or material, similar to the existing, factory installed, green/blue filter in the unit. The size of each filter (2 required per unit) is listed as follows: *ERVR100 10 ½ x 10 ½ *ERVR200/300 10 ½ x 21 ¾ * First letter of model number may be an A or T. C) Filters must always be used during unit operation or the heat transfer core will become blocked by particulate matter. The filters supplied in the unit are typically able to keep the heat transfer core clear for many months. Finer filters may be used but must be cleaned more often. HEAT TRANSFER CORE SERVICE. (The Heat Transfer Core may also be referred to as the Energy Exchange Element or Heat Exchanger) Vacuum the Face of the Heat Transfer Core Yearly. Particulate matter collects only on the entering faces of the heat transfer core. The interior of the heat transfer core stays clean even if the element faces are covered particulates. TO CLEAN THE HEAT TRANSFER CORE: 1. Remove filter retainer spring and the filters (see above). 2. Vacuum the exposed faces of the heat transfer core with a soft brush attachment. 3. After servicing the filters, re-install them and the filter retainer spring (see above). 4. Vacuum out dust from the rest of the unit case.! CAUTION DO NOT WASH THE HEAT TRANSFER CORE. Always handle the core carefully. Keep it away from water or fire to avoid damaging it. The heat transfer core can be replaced but is expensive. 2 32-5042-02

Heat Transfer Core Filter Retainer Figure 1 Energy Recovery Ventilator with cover removed Power Light Runtime % Lights Press Fan icon on touchpad one or more times to obtain desired Runtime %. Press Fan icon on touchpad one or more times to obtain desired Runtime (Press once for 20 minutes, twice for 40 minutes, three times for 60 minutes) Press the Fan icon for 5 seconds to cancel. Figure 2 Figure 3 Percent Timer (P.T.) Control Optional Push Button Control 32-5042-02 3

PERCENT TIMER CONTROL (PT) The Percent Timer Control automatically energizes and deenergizes the energy recovery ventilator every hour, ensuring ventilation for the home around-the-clock. The PT control has two status lights (See Figure 2). One is the power light located in the upper left hand corner of the control. The other light will be one of the Runtime % lights. The power light is on whenever the PT control is calling for the ERV to run. The Runtime % light is located along the right side of the control. The Runtime % light indicates the amount of time per hour the ERV will operate. Set the control per your local code or ASHRAE Std 62.2 and your ventilator will run once every hour. FOR CONSTANT OPERATION: Press the fan icon until the 100% light is on. The Runtime % light turns on. The ERV unit will run continuously. FOR MINIMUM VENTILATION REQUIREMENT OPERATION: Set the control at the percentage that meets local code or ASHRAE 62.2. Press the fan icon until the light for the percent desired is on. TO TURN THE ERV OFF: Press the fan icon until all lights are off. The control is off. The ERV motor is de-energized. (Power is still persent inside the unit. Always unplug cord from outlet before servicing!) GENERAL SETTINGS: For systems installed in an area with high humidity. The Percent Timer should be set to deliver the Minimum Ventilation Requirements. VACATION SETTINGS: For systems installed in an area with high humidity. If the A/C system thermostat setting is elevated or set up while on vacation or for extended periods of time (over 2 days), the Percent Timer and ERV should be turned OFF. After returning from vacation or when the system thermostat is lowered to normal daily setting, the Percent Timer and ERV should be reset to the previous runtime %. WHEN WINDOWS ARE OPEN: When windows are open in your home the Percent Timer and ERV should be turned OFF. NOTE for ERV systems with more than one control: Another control may be causing your ventilator to run -even if the runtime % light on this control is off. If you wish to keep your ventilator from running, check that none of your controls are calling for unit operation. Installation 1. Install control in a standard 2" x 4" electrical box, with a minimum depth of 1.5", with the two screws provided. 2. Wire Size: 18 gauge, no more than 500 feet. Wiring is non-polar. 3. The two wires from the ERV should be attached to the C and R positions on the terminal block on the back of the PT Control. See Figure 13. 4. Use Lutron Decora cover plate to complete the installation (supplied by installer). PUSH BUTTON POINT-OF-USE CONTROL (OPTIONAL ACCESSORY) For use with all ERV models Operation The Push Button (PB) Point-of-use Control lets you manually turn on your energy recovery ventilator for a short period of operation for example, when you are using a bathroom. The PB Control must be connected to a PT control to operate. 20-40-60 minute ventilation control: Press the fan icon and your ventilator will run for 20 minutes (See Figure 3). Press again and the unit will run 40 minutes. A third press provides for 60 minutes of operation. Percent Timer Control does not need to be on for the PB Control to operate the ERV unit. You can cancel a cycle at anytime. Just press the fan icon and hold for about five seconds. You can start another cycle by pressing the fan icon. NOTE for ERV systems with more than one control: Another control other than the push button may be causing your ventilator to run. If you wish to keep your ventilator from running, check that none of your controls are calling for unit operation. Installation 4. Install control in a standard 2" x 4" electrical box, with a minimum depth of 1.5", with the two screws provided. 5. Wire Size: 18 gauge, no more than 500 feet. Wiring is non-polar. 6. Two wires from the PB Control should be attached to the PB positions on the terminal block on the back of the Percent Timer Control. 7. For two PB controls, one wire from each can be twisted together and inserted into a single position on the terminal block on the Percent Timer Control. The wires must be a 18 gage solid wire. If more than two PB controls are attached or 18 gage stranded wire is used then pigtails must be inserted into the PB positions on the Percent Timer Control and the leads attached to the pigtails with wire nuts. 8. Use Lutron Decora cover plate to complete installation. 4 32-5042-02

Limited Warranty Energy Recovery Ventilator (ERV) ERVR100, 200, 300 (Parts Only) Models for Residential Use* This limited warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the ERV is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada only. If any internal functional part of your ERV fails because of a manufacturing defect within five years from the date of the original purchase, Warrantor will furnish without charge the required replacement part. Any local transportation, related service labor, diagnosis calls, and related items are not included. If compatible ERV controls are incorporated in the HVAC system and are installed at the same time as your ERV, then if any Warrantor furnished internal functional part of the ERV controls fail because of a manufacturing defect within five years from the date of original purchase, Warrantor will furnish the required replacement part. Any local transportation, related service labor, diagnosis calls, refrigerant and related items are not included. THIS LIMITED WARRANTY IS IN LIEU OF ANY EXPRESS WRITTEN LIMITED WARRANTY ACCOMPANYING ANY OF THE ABOVE INDOOR PRODUCTS. If the heat transfer core should become defective because of a manufacturing defect within ten years from the date of original purchase, Warrantor will furnish without charge the required replacement heat transfer core. Any local transportation, related service labor, diagnosis calls and related items are not included. This limited warranty does not cover failure of your ERV if it is damaged while in your possession, damage caused by acts of God, damage from unreasonable use of the ERV and/or damage from failure to properly maintain the ERV as set forth in the Users Information Guide. THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS OR IMPLIED, IN LAW OR IN FACT, INCLUDING BUT NOT SPECIFICALLY LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Parts will be provided by our factory organization through an authorized service organization in your area listed in the yellow pages. If you wish further help or information concerning this limited warranty, contact: American Standard Inc. 6200 Troup Highway Tyler, TX 75707 Attention: Manager, Field Operations Excellence GW-658-0106 * This limited warranty is for residential usage of this equipment and not applicable when this equipment is used for a commercial application. A commercial use is any application where the end purchaser uses the product for other than personal, family or household purposes. 32-5042-02 5

Limited Warranty Energy Recovery Ventilator (ERV) ERVR100, 200, 300 (Parts Only) This limited warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the ERV is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada only. There is no warranty against corrosion, erosion or deterioration. If any internal functional part of your ERV fails because of a manufacturing defect within one year from the date of the original purchase, Warrantor will furnish without charge the required replacement part. Any local transportation, related service labor, diagnosis calls and related items are not included. If compatible ERV controls are incorporated in the HVAC system and are installed at the same time as your ERV, then if any Warrantor furnished internal functional part of the ERV controls fail because of a manufacturing defect within one year from the date of original purchase, Warrantor will furnish the required replacement part. Any local transportation, related service labor, diagnosis calls, refrigerant and related items are not included. THIS LIMITED WARRANTY IS IN LIEU OF ANY EXPRESS WRITTEN LIMITED WARRANTY ACCOMPANYING ANY OF THE ABOVE INDOOR PRODUCTS. If the heat transfer core should become defective because of a manufacturing defect within ten years from the date of original purchase, Warrantor will furnish without charge the required replacement heat transfer core. Any local transportation, related service labor, diagnosis calls and related items are not included. This limited warranty does not cover failure of your ERV if it is damaged while in your possession, damage caused by acts of God, damage from unreasonable use of the ERV and/or damage from failure to properly maintain the ERV as set forth in the Users Information Guide. THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS OR IMPLIED, IN LAW OR IN FACT, INCLUDING BUT NOT SPECIFICALLY LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Parts will be provided by our factory organization through an authorized service organization in your area listed in the yellow pages. If you wish further help or information concerning this limited warranty, contact: American Standard Inc. 6200 Troup Highway Tyler, TX 75707 Attention: Manager, Field Operations Excellence GW-659-0106 Models for Commercial Use* * This limited warranty is for commercial usage of this equipment and not applicable when this equipment is used for a residential application. A commercial use is any application where the end purchaser uses the product for other than personal, family or household purposes. American Standard Inc. 6200 Troup Highway Tyler, TX 75707 For more information contact your local dealer (distributor) Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice.