Environmental Management System

Similar documents
BUSHFIRE MANAGEMENT PLAN (BMP)

Fire Safety Strategy

FIRE SAFETY MANAGEMENT PLAN

UNCONTROLLED IF PRINTED. Issued with the authority of the Chief Commissioner and General Manager of Scouts Australia NSW

BUSHFIRE RESPONSE PLAN

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

Rural Fire Management Manual for UQ Gatton Campus

Appendix 29. Mount Emerald Wind Farm Fire Management Plan Prepared by RATCH Australia Corporation Limited

Fire Safety Policy. Document Author: Director of Estates, Fleet & Facilities Management

Appendix U.1 Bushfire Management Plan September 2011

To: All SAAS Accredited Certification Bodies Subject: Clarification to Emergency and Health & Safety Requirements in the SA8000 Standard

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

Slight Harm Moderate Harm Extreme Harm Low Trivial Risk Tolerable Risk Moderate Risk Medium Tolerable Risk Moderate Risk Substantial Risk

The Corporation of the District of North Cowichan Fire Protection Bylaw Bylaw 3340

BUSHFIRE CONSTRAINTS ASSESSMENT FOR THE SHONE AVENUE WEST DAPTO ROAD NEIGHBOURHOOD PLAN HORSLEY

BUSHFIRE THREAT ASSESSMENT REPORT. Special Fire Protection Purpose Development. North Byron Beach Resort. Proposed Central Facilities

Regulatory Reform (Fire Safety) Order 2005 Category of Premises against the FSO 2005: Sleeping Accommodation

NOTTINGHAM CITY HOMES

Bushfire Evacuation Plan

AFEC FIRE ENGINEERING TEMPLATE FOR CLIENTS INTERNALLY COMPLETED RISK ASSESMENT

DISTRICT OF PORT HARDY BYLAW A BYLAW TO ESTABLISH AND REGULATE THE DISTRICT OF PORT HARDY FIRE DEPARTMENT

Health and Safety Policy. Version Author Revisions Made Date 1 Colin Campbell First Draft March 2014

Planning Proposal Toronto Road, Booragul. Amendment to Lake Macquarie Local Environmental Plan (LMLEP) 2014

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM

protection community A Fire Force

Guideline for Fire Safety Plan

Millfield Schools Fire Risk Prevention Policy

ANALYSIS OF CALLS RESPONDED TO BY THE CITY FIRE BRIGADE ~ YEAR GRAND TOTAL :

LYHA Fire Safety Policy

June 2017 (Updated 18 January 2018) Fire Safety Policy. Peter Webb, Project Manager Compliance First Choice Homes Oldham Limited

Fire Risk Management Policy. UK September 2017

Fire Safety Policy 29/09/2017. Holme Grange School Whole School Policy Including EYFS. Fire Safety Policy

Fire Risk Assessment 2017

The Regulatory Reform (Fire Safety) Order Fire Risk Assessment Report

Fire Safety Policy SH HS 06. Version: 4. Summary:

Workplace Guidelines

REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT

Dan Gray, Property Director. Date: November 2017 Review Due Date: November 2020

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett

EMERGENCY PREPAREDNESS - POLLUTION INCIDENT RESPONSE PROGRAM

Bush Fires. Fact Sheet 35. Environmental Defender s Office of Western Australia (Inc.) An introduction to Bush Fires. What is a bush fire?

Black Creek Oyster Bay Fire Service Administration Bylaw No. 293, 2014

H&S Forum. Fire Safety Policy Glascote Academy

Fixed plant and mobile equipment fires on surface coal mines

Fire safety management issues identified by fire risk assessments

PASCOE S PTY LTD EMERGENCY RESPONSE MANUAL. (Public Version) SOP 517. July 2015

CLYST ST. MARY VILLAGE HALL

NHS Tayside. Fire Safety Policy

Fire Risk Assessment Safety Checklist

Draft Ada Street Cardiff Area Plan

NOT PROTECTIVELY MARKED. Fire Legislation

Managing Fire Risk for New Rural Dwellings

Environmental emergency preparedness and response

South Australian Regulatory Requirements

Health, Safety and Wellbeing Management Arrangements. Core I Consider I Complex. Fire Safety. Health, Safety and Wellbeing Service

S12 Fire Safety Risk Assessment H&SFS01-1 / 9

Australian Standard. Fire hydrant installations. Part 1: System design, installation and commissioning AS

Fire safety policy. Contents. This policy was approved by the Trustees on 3 September 2015 and will be reviewed not later than every 3 years.

Fire Safety Policy 2018/19

EMLC Academy Trust. Fire Safety Policy 2017/19. Every child deserves to be the best they can be

Fire risk management plan. MH/05/Revised/06/17

REPORT AND SPECIFICATION FOR RESTORATION WORKS ON NELLIES GLEN ROAD and THE 6 - FOOT TRACK NELLIES GLEN

The Social Accountability International (SAI) Fire Safety Checklist

ROCHFORD LOCAL DEVELOPMENT FRAMEWORK: Sustainability Appraisal/ Strategic Environmental Assessment. Rochford Core Strategy Preferred Options Document

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT NEW BUILDINGS

COMMON SENSE FIRE PREVENTION MEASURES FOR SOLID WASTE OPERATORS Presented by the Sacramento County LEA Program and Sacramento Fire Department

Fire Prevention. Neal Hathaway

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

Planning Proposal Wangi Power Station Complex Administrative Amendment Lake Macquarie Local Environmental Plan 2014

Contractor Worksheet Underground Fires Major Hazard Standard

CFPA-E No 1:2014 F. Fire protection management system CFPA-E -GUIDELINES

Fire Risk Assessment. ABC Car Workshop. Prepared for. Redacted

FIRE SAFETY POLICY Revised March 2013

Peponi House Preparatory School Nairobi, Kenya. Peponi House Fire Risk Prevention Policy

BP MAINTENANCE WORK INSTRUCTIONS FREQUENTLY ASKED QUESTIONS

Byker Various post codes. Your Homes Newcastle Health and Safety (fire) Officer Date of Fire Risk Assessment 18 th February nd October 2014

Steven Craft, PhD, P.Eng. FIRE SAFETY DURING THE COURSE OF CONSTRUCTION

Fire Safety Policy. Contents. This policy was approved by the Trustees on 6 September 2018 and will be reviewed not later than every 5 years.

FIRE SAFETY POLICY & EMERGENCY EVACUATION POLICY

POLICY FOR FIRE SAFETY MANAGEMENT

Electrical Safety Policy and Management System

FIRE SAFETY POLICY. This policy document replaces any previously published documents and comes into effect September 2018.

COMMUNITY WILDFIRE PROTECTION PLAN POWELL RIVER REGIONAL DISTRICT

May 27, Mayor Joanne D. Yepsen Saratoga Springs Commissioners City of Saratoga Springs 474 Broadway Saratoga Springs, New York 12866

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

OUTLINE FOR FIRE PREVENTION ACTIVITY

Fire protection documentation. CFPA-E Guideline No 13:2015 F

CITY FIRE BRIGADE TURNOUT STATISTICS

RRC SAMPLE MATERIAL MANAGING FIRE SAFETY LEARNING OUTCOMES

Fire Safety Policy. (The Regulatory Reform (Fire Safety) Order 2005) Last Reviewed: January Next Review: January 2019

Fire Risk Assessment 2016

Objectives. NFPA Dust Specific Documents. Combustible Dust Process Hazard Safety Overview of NFPA Standards for Combustible Dusts

STATION RISK PROFILE 2018 EWYAS HAROLD

THE REGULATORY REFORM (FIRE SAFETY) ORDER 2005 FIRE RISK ASSESSMENT HORSEFAIR HOUSE

TIDAPA Structure Plan

Update on Company Emergency Response Team : Roles, Responsibilities & Requirements. MAJ THIYAGARAJAN RRS CERT Audit Team Leader HazMat Dept SCDF

Grand Avenue Primary and Nursery School. Policy for Fire Safety. Contents. 6. Prevention of fire Events taking place outside school hours

Planning Proposal Concurrent DA/LEP Amendment for Belmont North Pharmacy Amendment No. 24 to Lake Macquarie Local Environmental Plan (LMLEP) 2014

Section 3b: Objectives and Policies Rural Environment Updated 19 November 2010

Fire Safety Protocol

Transcription:

ILLAWARRA COAL Environmental Management System DENDROBIUM MINE BUSH FIRE MANAGEMENT PLAN

REVIEW HISTORY Revision Description of Changes Date Approved 0 Draft submitted Nov 04 Bryan Quinn 1.0 Incorporating comments on draft Feb 05 David Oliver 2.0 Three yearly review as required by Development Consent Mar 08 David Oliver 3.0 Review as required by the revised Development Consent (issued 8 December 2008) April 09 Wayne Price 4.0 Three yearly reviews in line with Development Consent conditions. Minor changes to roles and responsibilities section, references. Mar 12 Wayne Price Persons involved in the review of this document include: Name Title Company Chris Schultz Property and Landholder Relations Manager Dendrobium Mine Scott Coleman Environment Coordinator Illawarra Coal Frank Cook Senior Survey and Property Advisor Illawarra Coal Peter McMillan Environmental Coordinator- Southern Dendrobium Mine Joanne Page Environment Manager Illawarra Coal Ben O Brien Environment Coordinator Illawarra Coal Representatives from external organisations and regulatory agencies involved in the review of this document include: Title Organisation Community Safety Officer Rural Fire Service Captain Mt Kembla Fire Brigade Rural Fire Service Catchment Officer Sydney Catchment Authority Current Version Approval: Page 2 of 17

CONTENTS 1 INTRODUCTION... 4 1.1 BACKGROUND...4 1.2 SCOPE...4 2 OBJECTIVES OF THE PLAN... 4 3 RESPONSIBILITY... 5 4 LEGISLATIVE AND OTHER REQUIREMENTS... 5 4.1 LEGISLATIVE REQUIREMENTS...5 4.2 DEVELOPMENT CONSENT CONDITIONS...5 4.3 BHP BILLITON (BHPB) AND OTHER POLICIES AND STANDARDS...6 5 LOCATION CHARACTERISTICS AND SUMMARY OF BUSH FIRE RISK FACTORS... 6 5.1 LOCAL CONDITIONS, SITE CONDITIONS AND BUSH FIRE HISTORY...6 5.2 IGNITION SOURCES...7 5.3 PRESCRIBED BURNING...7 5.4 SITE CONDITIONS...8 6 BUSH FIRE RISK ASSESSMENT AND MANAGEMENT PROCESS... 8 6.1 BUSH FIRE RISK ASSESSMENT...8 6.2 BUSH FIRE RISK MANAGEMENT...9 7 REPORTING... 12 8 RECORD KEEPING...12 9 DOCUMENT CONTROL... 12 10 REFERENCES... 13 Page 3 of 17

1 INTRODUCTION 1.1 Background This Management Plan (BMP) covers the Dendrobium Mine and associated facilities, adjacent land and local community and environment. This document is a module of the Environmental Management System (EMS) document. This document contains an introduction to the EMS as well as the common aspects across the Environmental Management Plans. 1.2 Scope The scope of this BMP includes the following: The Dendrobium Pit Top; Kemira Valley Coal Loading Facility (KVCLF); Ventilation Shaft Number 1 (located within the Metropolitan Special Area administered by Sydney Catchment Authority (SCA); Ventilation Shafts Number 2 and 3 (located within the Metropolitan Special Area and within Mining Lease ML1566); and Local community and environment including adjacent lands, property, infrastructure, bushland and other natural environmental features 2 OBJECTIVES OF THE PLAN The objectives of the BMP are to: Comply with the Dendrobium Development Consent; Comply with relevant legislative and other requirements related to bush fire management; Provide the frame work for management of bush fire risks; Detail the measures in place to protect company, public and private assets and the natural environment from the adverse impacts of uncontrolled wild fire; Describe bush fire hazard reduction measures; Outline the control measures to prevent spread of fire from Company premises to adjacent lands; Describe the communications, response and processes in place to manage bush fire emergencies; Describe bush fire protection zone management practices; Minimise the fire risks to personnel, the general community and fire-fighters; Protect the local Sydney Catchment Area lands, natural features and infrastructure from the adverse impacts of uncontrolled bushfire; and Cooperate with relevant bush fire services and other authorities in relation to bushfire management, bush fire hazard reduction and emergency response Page 4 of 17

3 RESPONSIBILITY Implementation of the plan is the responsibility of the owners or occupiers (land managers) of the land on which the bush fire risk is situated. The Rural Fires Act 1997 imposes this responsibility on both public and private land managers. The roles and responsibilities relating to bush fire management at Dendrobium and related facilities are summarised in Table 3-1. Table 3-1: Roles and Responsibilities Management Responsibilities Overall coordination and periodic review of this management plan Coordination of on-site hazard mitigation strategies in association with the Rural Fire Service Coordination of risk assessments / inspections Coordination of off-site hazard mitigation strategies in association with the Rural Fire Service Coordination of off-site hazard mitigation strategies in association with the Rural Fire Service Participation in risk assessments / inspections Inspection and maintenance of fire fighting equipment, including mains, hydrants, extinguishers and hoses Role Environment Specialist Environment Coordinator - Southern Environment Coordinator - Southern Environment Coordinator - Southern Senior Survey and Property Advisor Senior Survey and Property Advisor Dendrobium Fire Officer 4 LEGISLATIVE AND OTHER REQUIREMENTS 4.1 Legislative Requirements Risk Management is both governed and restricted by the: Rural Fires Act 1997 (including Section 66 Notices), Work Health and Safety Act 2011, Local Bush Fire Management Plans, Local Operation Plan; The NSW Rural Fire Service (by way of Fire Permits and Hazard Reduction Certificates); and NSW Rural Fire Service, Planning for Protection Guideline (2006). 4.2 Development Consent Conditions Schedule 4 of the Dendrobium Mine Development Consent contains several conditions relating to bush fire management. This management plan has been developed in accordance with the requirements of the consent. Page 5 of 17

4.3 BHP Billiton (BHPB) and other policies and standards This Management Plan has been developed to be consistent with the principles of the BHPB Health, Safety, Environment and Community (HSEC) Management System and in compliance with the following BHP Billiton Group Level Documents (GLD): Environment GLD.009; Risk Management GLD.017; and Health, Safety, Environment and Community Reporting GLD.012 Dendrobium Mine maintains an environmental management system which is certified to ISO14001 standard. 5 LOCATION CHARACTERISTICS AND SUMMARY OF BUSH FIRE RISK FACTORS 5.1 Local Conditions, Site Conditions and History 5.1.1 Climate Wollongong is characterised by a relatively humid, temperate, moderate climate with annual average rainfall of 1200 to 1500mm. Temperature and rainfall conditions vary across the City (East of the escarpment) with the climate on top of the escarpment tending towards warm temperate. The average monthly summer temperature over the City is 24 C and the average monthly winter temperature over the City is 12 C. The escarpment has a significant influence on the climatic conditions of the region. There is significant variation in seasonal weather patterns conditions with the summer season being the prime bushfire period. 5.1.2 Vegetation The Illawarra escarpment is characterised by dense vegetation and undergrowth with variable vegetation types and communities including rainforests, wet and dry sclerophyll forests, heath-land, as well as grasslands, pastoral lands and open woodlands. The remote areas, steep slopes and dense bushland areas of the escarpment are difficult to readily access to manage uncontrolled bushfire. The locality of bushfire, available fuel load and the prevailing weather conditions are key factors influencing the significance of bush fire risk. 5.1.3 History The local Dendrobium Mine site locality, SCA areas and escarpment areas have been subject to significant bushfires in the past. Page 6 of 17

Significant fires occurred in September 1939, October 1968, November 1980, January 1994, December 1997, December 2000 and 2001. The most recent local uncontrolled bushfire event of significance occurred in the area around the Dendrobium No. 1 Ventilation Shaft area at Kembla Heights in September 2003. No loss of property or infrastructure occurred as a consequence of this event. These fires coincided with extended dry periods, hot, dry and windy conditions leading to extreme fire weather. All the above fires burnt extensive areas of bushland. 5.2 Ignition Sources Potential ignition sources at site include: Hot exhausts from vehicles; Spark or flame sources from grinders or welders; Frictional sources (surface conveyor) Electrical equipment faults; Auto combustion of mixed chemicals; Overhead power line arcing faults; Vegetation interference with overhead power lines; and Debris blown onto overhead power aerials External ignitions sources include: Illegal burning off; Torching of dumped cars; Inappropriately discarded cigarette butts; Deliberate lighting of bushland (arson); and Loss of containment of authorised hazard reduction burns Natural ignition sources include: Lightning strikes; and Spontaneous Combustion of organic matter 5.3 Prescribed Burning Prescribed burns are generally planned to be conducted between April to September each year when conditions are favourable. Prescribed burns can take place outside this period if suitable conditions exist. If the weather restricts the completion of the prescribed burning program, incomplete proposals are reviewed by the Illawarra Management Committee and rescheduled where able to. Prescribed burning programs may be supplemented with mechanical clearing. Page 7 of 17

5.4 Site Conditions 5.4.1 Dendrobium Pit Top The Dendrobium Mine Pit Top area is predominantly cleared of natural vegetation with some remnant stands of trees remaining on site (refer to Figure 10-1 for site layout). The site is surrounded by dense bushland vegetation in proximity to the Mount Kembla Village and Kembla Heights communities. The site property boundary is characterised by steep and densely wooded in areas. A relatively large proportion of the Pit Top area working and storage area is sealed. 5.4.2 Kemira Valley Coal Loading Facility (KVCLF) KVCLF is a cleared site with rehabilitated areas predominantly grassed. The KVCLF borders highly naturally vegetated areas (escarpment) to the North and West and grassed pastoral lands to the East. The majority of roads on the site are sealed. (Refer Figure 10-1). 5.4.3 Ventilation Shaft No. 1 The Ventilation Shaft No. 1 site is located within the Sydney Water Catchment Area. The site is surrounded by natural bushland. The access road is unsealed. 5.4.4 Ventilation Shaft No.2 and 3 The Ventilation Shaft 2/3 site is located in the Sydney Water Catchment Area. The site is accessed via the unsealed Fire Trail 6C. A fire protection buffer zone is provided around the site boundary. The site is surrounded by bushland (Refer Figure 10-2). 6 BUSH FIRE RISK ASSESSMENT AND MANAGEMENT PROCESS 6.1 Risk Assessment Bush fire risk is defined as the chance of a bush fire causing harm to persons, property and the natural environment. Key factors determining the significance of the risk include: Actual and potential consequences of the fire; Locality of the fire; Prevailing conditions; Fire fighting resources available; and Capacity and ability to affectively respond to and control the fire Key Risk Control Measures include: Maintenance of fire protection zones and boundaries; Hazard reduction activities; Page 8 of 17

Control of activities on site; Training of personnel; Competency of Emergency Response Services; Availability of resources, personnel and equipment to attend fires; and Inspections and assessment 6.2 Risk Management Bush fire risk in relation to the Dendrobium sites is mitigated by the following specific activities: Access roads and trails are monitored during regular inspections, with remedial and maintenance work carried out as required; Unauthorised access is prevented by locking Fire Trail access gates and access gates to other controlled areas. Fire Trails are maintained to a standard for Category 1 Fire Tanker access where possible; The Company Asset Protection Zones are maintained between Dendrobium sites and neighbouring land and property; and Hazard reduction programs are carried out in accordance with the Planning for Protection Guidelines and in cooperation with the relevant authorities Areas targeted near the Dendrobium Pit Top include land holdings bordering onto the local community housing areas. An asset protection zone is maintained at the urban interface with the Dendrobium Pit Top and the KVLF. Kemira Valley contains cleared sections of land between the Dendrobium holdings and the Mt Kembla community. A large portion of this land is used as pastoral land and acts as a buffer between the KVCLF site and residential land. An asset protection zone is maintained around the No.1 Ventilation Shaft infrastructure. A sediment pond at the Ventilation Shaft 2/3 site is available for the provision of water for fire fighting purposes at this site. Cordeaux Dam is located in close proximity to the site and could be used as a source of water for aerial fire fighting. Asset Protection Zones are periodically reviewed with the involvement of relevant agencies Relevant agencies include the NSW Rural Fire Service, Wollongong City Council and the Sydney Catchment Authority. Asset Protection Zones are reflected in Figure 10-3: Asset Protection Zones - Dendrobium Pit Top, Kemira Valley and Ventilation Shaft 1 and Figure 10-4: Asset Protection Zone - Ventilation Shaft 2/3. Page 9 of 17

6.2.1 Hazard Reduction Authorisations and Permits Appropriate authorisations and permits are obtained for hazard control burning and vegetation clearing as follows. Hazard Control Burn To conduct a hazard control burn requires a Hazard Reduction Certificate and a Fire Permit from the NSW Rural Fire Service under s87 or s88 of the Rural Fires Act 1997. In the event that a Hazard Reduction Certificate is not required, a Review of Environmental Factors is carried out prior to any undertaking any burning activities. Hand Clearing and Machine Clearing Except for general maintenance, hand clearing and machine clearing requires a Hazard Reduction Certificate. In the event that a Hazard Reduction Certificate is not required, a Review of Environmental Factors is carried out prior to any undertaking any burning activities. 6.2.2 Risk Management and Emergency Response Procedures On-Site The following documents are in place at Dendrobium Mine: Fire and Explosion Major Hazard Management Plan (DENMP0027) identifies the fire hazards, resources, procedures, equipment and inspections, required to maintain a system for fire prevention and fire fighting capability. Emergency Fire Provisions (DENP0017) describes the facilities in place at the mine to allow for adequate fire fighting ability. Incident Management Manual Overview (DENMP0077) defines a standard set of procedures and responses to ensure the effective management of any incident, threat, injury or emergency arising from any source at the mine where the relevant Critical Safety Hazard Management Plan has been ineffective in controlling the fundamental hazard. Incident Management Manual Incident Response (DENP0076) defines the actions that are to be taken in response to a fire or other emergency by persons at the mine. Dealing with Risk (DENP0093) informs employees of the steps to be taken if there is Bush Fire activity around the surface infrastructure of the mine. Smoke Underground During s (DENP0201) defines gas monitoring and evacuation procedures to be established in the event of smoke from s entering the underground workings. Procedure for Evacuation in Event of Fire (DENP0069) covers the emergency evacuation of personnel from the underground areas of the mine in the event of an outbreak of fire. Surface Evacuation (DENP0249) provides a procedure for evacuation of the surface area of the mine in an emergency. Loss of Pressure or Quantity of Water to the Fire Fighting Supply System (DENP0035) ensures the safety of the persons who are underground when the water supply to underground is interrupted, or becomes ineffective. Page 10 of 17

The Fire and Explosion Major Hazard Management Plan is relevant to the Dendrobium Pit Top site, Kemira Valley Coal Loading Facility, and the Dendrobium Ventilation Shaft sites. It also covers management of the Dendrobium underground, regarding risks, requirements, maintenance, roles etc. In the event of an emergency at a Dendrobium controlled site, the Dendrobium Standard Procedure Emergency Contacts is referenced. Table 6-1: Emergency Contact List Contact Number Emergency number (Fire Brigade) 000 Dendrobium Control Room (Dendrobium sites incl. KVCLF) 4255 4402 Environment Protection Authority 131 555 Wollongong City Council 4227 7111 Sydney Catchment Authority Emergency Reporting (24 hours) 1800 061 069 Endeavour Energy 131 003 In the case of an emergency and where a tanker is required on site, the Rural Fire Service (RFS) will be contacted. 6.2.3 Fire Fighting Aides and Suppressants In addition to the vegetation control measures, fire-fighting aides are available on-site for attending to fires. Fire hydrants, extinguishers, fire blankets, connections and hoses are installed at strategic locations around the sites. Fire fighting systems at the Pit Top uses the town water source, whilst the KVCLF utilises recycled site water. In the event of a bush fire the KVCLF Stockpile Sprays can be utilised to dampen the coal stockpile area. Fire fighting tenders and resources are needed to be taken to the Shaft site (No1,2&3) as no fire fighting system is readily available at the sites. Non-essential personnel are required to evacuate SCA controlled areas in the event of bushfire threat. Site fire fighting apparatus and systems are inspected for good working order on a monthly basis by the Dendrobium Fire Officer. Automatic fire equipment and fire alarms are tested by a contracting firm. Gutters and other fire hazard collection points are inspected and addressed on a three-monthly basis to ensure that leaves and other flammable material are removed as required. 6.2.4 Fire Training for Company Personnel Company personnel are trained in basic fire fighting by attending Southern Mines Rescue Training. This training is compulsory and is carried out on an annual basis. Most employees on site are capable of operating fire-fighting equipment. Page 11 of 17

6.2.5 Construction of buildings in -prone areas Australian Standard AS 3959 1999 specifies requirements for the design and construction of buildings in -prone areas. Where required, buildings will comply with the requirements of AS 3959. Fire Safety Statements are completed for the bathhouse at the Dendrobium Pit Top and the Sizer at Kemira Valley on an annual basis. 7 REPORTING management activities undertaken in the period are reported in the annual Environmental Management Report (AEMR). The AEMR is distributed to relevant agencies and stakeholders. Bush fire events associated with the Dendrobium operations will be reported to relevant agencies whenever they occur. 8 RECORD KEEPING Reports containing information relating to monitoring, inspections and observations, correspondence, notification and approvals, records of communication with statutory authorities and other bodies, audit reports and reviews are maintained for a period of at least 7 years and are available in the Companies records management system. 9 DOCUMENT CONTROL The Management Plan is controlled within the Mine s Document Management System Revisions to the Plan are limited to persons with the appropriate authority. Plan versions and updates are tracked in the Document Management System. Page 12 of 17

10 REFERENCES BHP Billiton Charter BHP Billiton Environment Group Level Document (GLD.009) Dendrobium Mine - Smoke Underground During s (DENP0201) Dendrobium Mine - Dealing with Risk (DENP0093) Dendrobium Mine - Designated Areas, Smoking Materials and Searches (DENP0036). Dendrobium Mine - Emergency Fire Provisions (DENP0017) Dendrobium Mine Incident Management Manual Overview and Incident Response (DENMP0076) and (DENMP0077) Dendrobium Mine - Evacuation in Event of Fire (DENP0069) Dendrobium Mine - Loss of Pressure or Quantity of Water to the Fire Fighting Supply System (DENP0035) Dendrobium Mine - Fire and Explosion Major Hazard Management Plan (DENMP0027) Dendrobium Mine - Surface Evacuation (DENP0249) NSW Rural Fire Service (2006) Planning for Protection Guideline NSW Rural Fire Service (2008) Illawarra Risk Management Plan Work Health and Safety Act (2011) Rural Fires Act (1997) AS3959 (1999) Requirements for the Design and Construction of Buildings in Prone Areas State Environmental Planning Policy (Sydney Drinking Water Catchment) 2011- SEPP28 Page 13 of 17

Figure 10-1: Site Plan - Pit Top, Kemira Valley and Ventilation Shaft 1 Page 14 of 17

Figure 10-2: Site Plan - Ventilation Shaft 2 and 3 Page 15 of 17

Figure 10-3: Asset Protection Zones - Dendrobium Pit Top, Kemira Valley and Ventilation Shaft 1 Page 16 of 17

Figure 10-4: Asset Protection Zone - Ventilation Shaft 2/3 Page 17 of 17