June 10, 2002 DF C S2424

Similar documents
July 14, 1999 DF C-100.

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

ECC-50/100C. Emergency Command Center

ECC-50/100(E) Emergency Command Center

PN: 51604:A ECN Voice Evacuation Control Panel FIRE COMMAND 25/50X & FIRE COMMAND 25/50XE. Document # /17/02 Rev.

SP40S-D. Kingfisher Company, inc. Features: Description:

SAFEPATH Mass Notification System (SPMNS)

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

FireNET Plus Wiring Instructions

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL600ULADA. NAC Power Extender. Installation Guide

Specification/ Data Sheet

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Pompano Pet Lodge 930 Northwest 31 st Avenue Pompano Beach, FL 33069

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

Cautions and Warnings. Introduction 4009 NAC POWER EXTENDER

30.45 Electric Release PDRP-2001

Booster Power Supply Manual

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

AL800ULADA. NAC Power Extender. Installation Guide

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

SAFEPATH DoD facility communications system & expansion options

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Emergency Command Center ECC-50/100 ECC-50/100E. Instruction Manual. Document LS FL-E 5/3/2016 Rev: G P/N LS FL-E:G ECN

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information)

E3 Series Broadband System

Autonomous control unit

Remote NAC Power Supply D7038

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Supplement to The PDRP-1001/PDRP-1001A/PDRP-1001E Deluge Preaction Control Panel Manual

10-175UL INSTALLATION. Power Supply UL. Access Control Power Supply/Charger. Installation and Specifications Manual

1 Description. 2 Specifications. HP600ULM Access Control Power Supply/Charger with Power Distribution Controller PN 52393:A 1/05/06 ECN

LifeAlarm Fire Alarm Control Panels

TECHNICAL DATA OBSOLETE

SAFEPATH SAFEPATH. Emergency communications system

PSN-1000 & PSN 1000(E) Installation Manual

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Notification Appliance Circuit Module

TrueAlert Addressable Notification

AL1002ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

TrueAlert Addressable Notification Appliances

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

AL1042ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev X

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

AL1042ULADA. NAC Power Extender. Installation Guide (See Application Guide for additional information) Rev

Release Control Fire Alarm Systems

ACSI Series 1550K-MD and 1550-MD Motor Drive Electric Latch Retraction

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Addressable Fire Alarm Control Panel

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MS Rev. 2/DACT-UD: Intelligent Addressable FACP with Optional 2nd Loop

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Conventional Releasing Control Panel

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Rev. A. Technical Manuals Online! -

good things in small packages

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

Series. Access Power Controllers. Installation Guide

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

LifeAlarm Fire Alarm Controls

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

Fire Safety. Installation Instructions Model SMB-2 Main Control Board OPERATION INSTALLATION

Addressable NAC Output Module D327A

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

Fire Alarm Testing and Inspection Report

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

This wiring diagram describes circuit connections for all models of the Series Quaestor-SZU Releasing Fire Control

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

E3 Series Broadband System

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

Fire Control/Communicator

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

Installation Guide for models:

Installation Guide for models:

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

MPC-6000 / MPC-7000 / RND-2

ELECTRONIC SOUNDER STROBE Model : AVD-C407

FireSeeker Fire Alarm Control Panel Model FS-100 Installation, Operation, and Maintenance Manual

AL600ULX Series. Power Supply/Charger. Installation Guide

Commercial and Light Industrial Fire Alarm Control Panel

1. POWERPATH Operation

INTELLIGENT FIRE ALARM CONTROL UNITS. MMX TM Series Intelligent Fire Alarm & Network System

ECC-50DA/E ECC-125DA/E ECC-50BDA/E. Distributed Audio Amplifiers. Installation Manual C. Document LS FL-E 1/30/2014 Rev:

RELEASE DEVICE CONTROLS

FCPS-24F/FCPS-24FE. Field Charger/Power Supply D P/N 50079:D ECN Installation, Operation and Application Manual

Transcription:

GENERAL www.firelite.com The Fire Lite FIRE COMMAND 25/50X is a state-of-theart Emergency Voice Evacuation Control Panel (VECP), with significant technological enhancements that set it apart from other voice panels. These enhancements include full supervision in both active (alarm or music) and standby conditions, optional remote microphone, message and tone generator backups, independent power feed to each amplifier, and full output power per amplifier (including when using 70 VRMS option) generated while in low battery condition. The FIRE COMMAND 25/50X is suitable (but not limited to) as an adjunct to most UL listed Fire Alarm Control Panels (FACP) in applications such as restaurants, schools, auditoriums, dormitories, theaters, places of worship, motels, hotels, office buildings, and factories to name a few. A host of field-programming options, including dual-message capability (fire, adverse weather, non-fire, multi-language), makes the FIRE COMMAND 25/50X a very versatile voice evacuation system. STANDARD FEATURES Built-In Power Supply - An internal power supply and battery charger is built-in to unit. Ground fault detection with diagnostic LED (yellow). Brownout detection with battery transfer. Battery trouble detect with diagnostic LED (yellow). Battery saver operation. Independent AC loss relay provides AC loss delay per UL, for independent monitoring by DACT (2 Amps at 24 VDC). AC power on LED (green). 18 AH battery charging capacity up to 7 AH may be utilized in FIRE COMMAND enclosure. 12 AH - 18 AH require Fire Lite BB-17F battery box. Large, teeter-plate terminal blocks easily accept up to 12 AWG for power terminations. Full supervision in both active (alarm or music) or standby conditions: Amplifier outputs Field wiring (shorts and opens) Message generator All tone generators Microphone June 10, 2002 DF-52338 C-025 FIRE COMMAND 25/50X Emergency Voice Evacuation Control S2424 Patent # 5,883,573 Section: Emergency Voice Evacuation MEA California State Fire Marshal 6911-0075:181 Integral 25 Watt, 25 VRMS audio amplifier with single Class A/Class B speaker circuit (expandable to two with optional 25 watt expander amplifier). Integral digital message repeater with 'primary' and 'secondary' dual 30-second message capability or one 60-second customer message. Integral supervised microphone. Dual Command Input (trigger) circuits field selectable to be activated from 12 or 24 VDC Notification Appliance Circuit (reverse polarity) or contact closure. Built-in tone generators (field selectable). Field-selectable lead-in/trailing tone selection. 12 integral diagnostic LED's. 70.7 VRMS conversion module available for each amplifier. local playback speaker. Remote Microphone Module FC-RM (use included interface module FC-MIM). Distributed Audion Panel (FC-25/50DA). This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact: Fire Lite Alarms, One Fire-Lite Place, Northford, Connecticut 06472. Phone: (800) 627-3473 Toll Free FAX: (877) 699-4105 FAX Back:(888) 388-3299 DF-52338 Page 1 of 6

OPTIONAL MODULES FC-AAM25X 25 Watt, 25 VRMS audio amplifier module. Field-programmable for system expansion to 50 Watts (providing dual 25 Watt speaker circuits) or as a backup to the primary 25 Watt amplifier, where required. Provides single Class A or Class B speaker circuit. Utilizes plug-in style terminal blocks for ease of service and maintenance. Fully supervised and power-limited. Diagnostic LEDs include: yellow trouble LED (cable fault, 70 V RMS fault, amp fault) and green, amp functional LED. FC-XRM70 Converts 25 VRMS audio outputs to 70.7 VRMS for retrofit applications. Plugs directly on FC-AAM25X module(s), allowing independent conversion to 70.7 VRMS. FC-LPS Provides local digital message playback for user review of field-recorded custom messages. STANDARDS AND CODES The FIRE COMMAND 25/50X complies with the following standards: NFPA 72-1993 National Fire Alarm Code; NFPA 101-1994 Life Safety Code; UL 864 Standard for Control Units for Fire Alarm Systems, UL 1711 Amplifier for Fire Protective Signaling Systems. SPECIFICATIONS Primary (AC) Power: 1.0 Amp max. @ 120 VAC, 50/60 Hz. Secondary Power (Battery) Charging Circuit: Supports lead acid batteries only. Float charge voltage: 27.6V. Maximum charge current: 800 ma. Maximum battery charging capacity: 18AH (batteries greater than 7 AH require BB-17F battery box). CABINET SPECIFICATIONS Door: 18.65" (473.71 mm) high x 15.65" (397.51 mm) wide x 1.08" (27.43 mm) deep. Backbox: 18.50" (469.90 mm) high x 15.50" (393.70 mm) wide x 4.25" (107.95 mm) deep. Trim ring: outer measurement 21.62" (549.15 mm) high x 18.62" (472.95 mm) wide; inner opening 18.625" (473.07 mm) high x 15.625" (396.87 mm) wide; with six holes for #8-32 screws and cutouts for hinges. CONTROLS AND INDICATORS LED INDICATORS 1. Power On (green). 2. ALARM (red). 3. System Trouble (yellow). 4. Microphone Trouble (yellow). 5. Message Generator Trouble (yellow). 6. Tone Generator Trouble (yellow). 7. Record (green). 8. Playback (green). SWITCH CONTROLS 1. Record. 2. Silence. 3. Playback. 4. Manual Evacuate. 5. All Call. ORDERING INFORMATION FC-25/50X 25 Watt, 25 VRMS, slave Emergency Voice Evacuation Control Panel (VECP), with integral microphone, digital message generator and single Class A or Class B speaker circuit. FC-AAM25X 25 Watt, 25 V RMS Audio Amplifier Module with single Class A or Class B speaker circuit. FC-PSM Replacement 120 VAC, 60 Hz Power Supply/ Battery Charger Module. FC-RM - remote microphone module (includes interface module FC-MIM). FC-XRM70 70.7 VRMS Converter Module (1 required per amplifier). FC-LPS Local Playback Speaker FC-TR Trim Ring semi-flush mounting FC-Microphone Replacement microphone PS-1270 Battery, 12 volt, 7.0 AH (two required) PS-12120 Battery, 12 volt, 12.0 AH, (two required, requires BB-17F Battery Box) PS-12180 Battery, 12 volt, 18.0 AH, (two required, requires BB-17F Battery Box) BB-17F Battery Box, required to mount PS-12120 or PS-12170 batteries Page 2 of 6 DF-52338

SYSTEM CONFIGURATION Standard 25 Watt, 25 VRMS Audio Amplifier Audio Amplifier Module 25 Watt, 25 VRMS (FC-AAM25X) Power Supply Module Standard MASTER COMMAND BOARD (FC-MCB) INTEGRAL MICROPHONE (FC-Microphone for replacement) 70.7 VRMS Transformer Module (FC-XRM70) 51546bd.wmf BATTERIES DF-52338 Page 3 of 6

APPLICATIONS EXAMPLES One Speaker Circuit One 60s Message 25 Watts A very basic application consists of one FIRE COMMAND 25/50X and one amplifier with a single speaker circuit. A second amplifier can be installed as a backup if desired. This configuration is suitable for small facilities requiring no more than 25 watts of output power. A single fire evacuation message will be generated during an alarm condition from the host FACP. In this application, the NAC from the host FACP is connected to CMD1. The CMD1 out terminals are then terminated with an EOL for a Style Y Notification Appliance Circuit (NAC) or the terminals are wired back to the host FACP for a NAC. S5 DIP switch 2 is set to OFF which causes the speaker circuit to be activated by the CMD1 input. S5 DIP switch 5 is set to OFF which causes CMD1 input to be activated by a reverse polarity condition. NOTE: FIRE COMMAND 25/50X may be configured for use as a manual evacuate system only, without need for FACP NAC or contact closure for activation (trigger). One Speaker Circuit One 60s Message 25 Watts EOL - value dependent on host FACP FACP NAC Output TB6 TB2 TB5 AUX POWER CMD1 IN CMD2 IN 25/50X Master Board 4.75 K, 1W EOL Speaker AMP 1 Backup 52338ap1.wmf Page 4 of 6 DF-52338

Two Speaker Circuits Two 30s Messages (Fire and Non-Fire) 50 Watts This application consists of one FIRE COMMAND 25/50X and two speaker circuits which requires installation of the optional second amplifier (FC-AAM25X). This configuration is suitable for small facilities requiring no more than 50 watts of output power (providing dual 25-watt speaker circuits). A fire evacuation message (primary) will be generated over both speaker circuits during an alarm condition from the host FACP and an emergency (secondary) non-fire message (e.g., weather alert) can be manually generated over both circuits. In this application, the NAC from the host FACP is connected to CMD1. The CMD1 out terminals are then terminated with an EOL for a Style Y NAC or the terminals are wired back to the host FACP for a NAC. CMD2 is connected to a normally open contact which can be used to manually generate an emergency non-fire message (e.g., Tornado MFA). S5 DIP switch 2 is set to ON which causes transmission of the primary fire message over speaker circuits 1 and 2 upon activation of CMD1 and transmission of the secondary non-fire message over speaker circuits 1 and 2 upon activation of CMD2. S5 DIP switch 5 is set to OFF which causes CMD1 input to be activated by a reverse polarity condition and S5 DIP switch 6 is set to ON which causes CMD2 input to be activated by a contact closure. NOTES: 1) FIRE COMMAND 25/50X may be configured for use as a manual evacuate system only, without need for FACP NAC or contact closure for activation (trigger). 2) Command input one (CMD1 - primary message) activation overrides command input two (CMD2 - secondary message) activation. Two Speaker Circuits Two 30s Messages (Fire and Non-Fire) 50 Watts X 52338ap2.wmf DF-52338 Page 5 of 6

One Speaker Circuit One 60s Message 25 Watts Backed-Up This application consists of one FIRE COMMAND 25/50X with one amplifier and a single speaker circuit. A second amplifier can be installed as a backup if desired. This configuration is suitable for small facilities requiring no more than 25 watts of output power. A single 60 second fire evacuation message will be generated during an alarm condition from the host FACP or activation of the Manual Evacuate switch. In this application, the NAC from the host FACP is connected to CMD1. The CMD1 out terminals are then terminated with an EOL resistor for the FACP s Style Y NAC or the terminals are wired back to the host FACP for a NAC. S5 DIP switch 2 is set to OFF which causes the speaker circuit to be activated by the CMD1 input. S5 DIP switch 5 is set to OFF which causes CMD1 input to be activated by a reverse polarity condition. Backup Amplifier switch S1 is set to the Backup ON position. 18 AWG (0.75 mm²) or larger jumpers connect the Backup Amplifier TB2 Terminal 3() and Main Amplifier TB2 Terminal 1(), as well as Backup Amplifier TB2 Terminal 4( ) and Main Amplifier TB2 Terminal 2( ). Upon failure of the first or main amplifier, the audio from the backup amplifier will be switched out to the speakers. NOTE: In the optional 70 VRMS configuration, only the amplifier is backed up; the FC-XRM70 coupling transformer is not. For this reason, it is not necessary to install an FC-XRM70 transformer module on the backup amplifier. Host FACP NAC One Speaker Circuit One 60s Message 25 Watts Backed-Up FACP EOL Resistor TB6-1 2 MASTER CMD OUT - - TB2 1 2 3 4 CMD1 IN TB5 1 2 3 4 CMD2 IN (Alarm Polarities Shown) - - 25/50 X Main Circuit Board 4.75, 1W EOL P/N 75470 Backup Audio IN Backup Audio OUT (Supervisory Polarity Shown) - - - - - - - - 1 2 3 4 5 6 1 2 3 4 1 2 3 4 5 6 1 2 3 4 TB1 TB2 TB1 TB2 Speaker Backup Speaker Backup 52338ap3.wmf Page 6 of 6 DF-52338 FIRST AMPLIFIER Mounted on Main Circuit Board BACKUP AMPLIFIER Backup ON