Understanding Artificial Ice Operating Temperatures

Similar documents
Ice-System Operations Brief review of Refrigeration principals for Cold and Warm Brine Refrigerant Solution Ice-Surface Formation Procedure

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

Life-Cycle Energy Costs and Greenhouse Gas Emissions for Gas Turbine Power

Moisture in the Atmosphere. GEOG/ENST 2331 Lecture 9 Ahrens: Chapter 4

Psychrometric Engineering Applications

Museum Archive Dehumidification in Hot & Humid Climates

Press Release. How can the efficiency of the dryer section be increased? Dryer Section All Paper Grades. Heimbach wherever paper is made.

Dehumidification. Page 1. By John Burley

RAPB. Multi-Purpose Facility. Characteristics of Hockey Rink. Project profile Refrigeration technological innovation

Comfort and health-indoor air quality

HUMIDITY IN INCUBATION

Fundamental Principles of Air Conditioners for Information Technology

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Your guide to condensation and how to reduce it. Come home to comfort

MUNICIPAL ICE RINK PROGRAM

Effective temperature, relative humidity and air velocity combinations to provide most effective chilling

lmprovin Industrial Refrigeration -!nergy Efficiency

Humidity Control Systems for Civil Buildings in Hot Summer and Cold. Winter Zone in China

Condensation on Your Windows?

Humidity Control & Psychrometrics

Redesign of Bennett Hall HVAC System

Frequently Asked Questions

Town of Smithers Second Arena

Heating Installation Guide published by

INVESTIGATION FINDINGS III IMPACT OF INADEQUATE VENTILATION AND DISCHARGE SYSTEMS

Negative Superheat? Time to Check Your Tools

ASSIGNMENT OBJECTIVES

Owner s Manual for Swimming Pool Heat Pump

PREDICTION OF THE PRESSURE DROP OF CO 2 IN AN EVAPORATOR USED FOR AIR COOLING ABSTRACT 1. INTRODUCTION 2. EXPERIMENTAL SET-UP AND PROCEDURE

Scientific Principals and Analytical Model. Charcoal Cooler. Lisa Crofoot MECH 425, Queens University

Temperature. In the HVAC area, we talk about two kinds of temperatures.

Unit 4: Science and Materials in Construction and the Built Environment. Thermal Comfort

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Effect of Moisture on Building Systems!

FS 231: Final Exam (5-6-05) Part A (Closed Book): 60 points

Bert Phillips, P.Eng., MBA

3.4 Humidity. Types of instruments

Owner Municipality Built in 1978 Rebuilt in 2001 Rink and bleachers. Surface area (footprint) 4,140 m 2 (44,700 ft 2 )

Design Procedure for a Liquid Dessicant and Evaporative Cooling Assisted 100% Outdoor Air System

ENERGY EFFICIENCY PROJECTS. NO-COST AND LOW-COST UPGRADES FOR YOUR FACILITY In partnership with: Refrigerating Engineers & Technicians Association

Department of Mechanical Engineering ME 322 Mechanical Engineering Thermodynamics

AR/IA/UP 241 Lecture 5: Psychrometrics

COMPARING AIR COOLER RATINGS PART 1: Not All Rating Methods are Created Equal

SECTION 8 AIR SOURCE HEAT PUMPS UNIT 43 AIR SOURCE HEAT PUMPS

CRAWL SPACE MOISTURE CONTROL - A Fundamental Misunderstanding By Peter Carpenter, member ASHRAE, SBCCI

HVAC (Heating, Ventilating, and Air Conditioning)

Maintenance Matters. Maintaining Your Heat Recovery Ventilation System

Building Science Basics

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

liquid heating The density of the liquid changes as its temperature increases. This causes energy to be transferred throughout the liquid.

Residential Building Walls and Environment in Amman, Jordan

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

Guide To Troubleshooting INEFFICIENT COOLING FANS

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Dehumidification for Industrial Coating Applications. By: Jay Kranker Munters MCS

DEFROSTING METHODS Adapted from material originally provided by Kenneth S. Franklin, C.M., Director of Service, Hussmann Corporation

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

PhEn-602 Pharmaceutical Facility Design. Notes #7 J. Manfredi

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

The Experimental Validation of Numerical Modeling of the Air Distribution in the Indoor Ice Rink Arena

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

USING THE P-T CARD AS A SERVICE TOOL

Humidity Control Design Tips. R. Mark Nunnelly, PE, CxA, LEED AP President

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM

REPRODUCTION/DISTRIBUTION IS PROHIBITED. Energy-Savings Strategies for. Rooftop

Greenhouse Temperature Management

UFAD and Displacement Ventilation. Dan Int-Hout, FASHRAE Chief Engineer Krueger Richardson, Texas

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

How to ensure Thermal Comfort in buildings with CFD

cussons Refrigeration Assembly Range TECHNOLOGY REFRIGERATION AND AIR CONDITIONING CUSSONS TECHNOLOGY LABORATORY RECOMMENDATION

Use this Construction/HVAC Glossary to answer the questions below.

Humidity An excuse for the 80s

UTILIZING BUILDING ENERGY SIMULATION TO IMPROVE PROCESS LOAD HEAT RECLAMATION FOR A MULTI-SPORT ATHLETICS VENUE KEYWORDS

STRUCTURE ILLUSTRATION...3 IMPORTANT SAFETY INSTRUCTIONS 4 INSTALLATION INSTRUCTION..4 OPERATING YOUR REFRIGERATOR...5-6

Chapter 5: Atmospheric Moisture

Atmospheric Moisture: Relative Humidity and Dew Point

ME Mechanical Engineering Systems Laboratory. Experiment 3 - Mass and Energy Balances in Psychrometric Processes

Tucker Road A New Ice Rink Community Meeting 25 October 2018

Thermodynamics II Chapter 6 Mixtures & Psychrometry

Summary of Comments (Washington Revisions November 7, 2000) Update November 27, 2000

Thermal Energy. Conduction, Convection, and Radiation. Before You Read. Read to Learn. Conduction. section 2

CHAPTER I INTRODUCTION. In the modern life, electronic equipments have made their way

Author: JOHN BARLEY, PRODUCT MANAGER, SP INDUSTRIES INC.

Energy consumption storage facilities examined in ICE-E

Impact of Manual Defrost vs. Auto Defrost Freezers on Sample Temperature

Downloaded from

Re: AHRI Comments on Proposed Addendum be to ASHRAE Standard 189.1

THERMAL CONDUCTION. placed in a different position. Can you explain why the matches go out?

Hygrometry. The art or science of humidity observation

Weather: Why do we have weather? Does it serve a purpose?

Changes of State. Lesson 1

Modular Active. Chilled. Beams

Scottish Curling-Ice Group

Meteorology 432. Hygrometry Spring 2013

Authority - City Engineer Effective August 2, 2011 Amended November 1, 2011, November 1, 2012 and December 11, 2013

MARIYA INTERNATIONAL SCHOOL AL-JUBAIL L-8 PHYSICS WORKSHEET(Heat & energy )

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

Transcription:

Understanding Artificial Ice Operating Temperatures The ORFA is often contacted to provide guidance on best ice operational temperatures. There are some general temperature levels that have existed for many years with most still being considered reasonable targets to be met. However, it is important that today s ice maker understand the science and variables that exist in each facility that can render the following recommendations not applicable? Understanding the following variables will allow you to better comprehend the challenges you may be facing in your building. The following information from ORFA s Certified Ice Technician (CIT) professional designation training courses are shared as a quick overview to the subject and will allow the reader to better understand the variables that can impact many of the temperatures we are to discuss. Age, design and maintenance of the facility older buildings will lack today s equipment capabilities and will often struggle due to wear and deterioration of the refrigeration and mechanical systems. The design of the building may also challenge indoor temperatures. Poorly placed structural beams or mechanical ducts can reduce air flow and contribute to poor ice conditions. A lack of ongoing maintenance to pipes, pumps, air/fluid filters and refrigerants can cause the system to work harder and longer thus not allowing the ice to freeze quickly during the resurfacing process. Dew Point - temperature at which air reaches 100% relative humidity (saturation) and the vapor begins to condense to a liquid. Relative Humidity (RH) - ratio of water vapor in air to the maximum amount or water vapor that the air could hold at a given temperature and pressure. Wet Bulb Thermometer - thermometer with a wet wick around its bulb. Cooling effect of evaporation depends on the amount of moisture (relative humidity) of air, so by comparing wet bulb temperature with a dry bulb temperature, relative humidity may be determined. Humidity - moisture, dampness in the air. Geographical location an arena in the far north will naturally have better ice due to outside conditions when compared to a rink in the south. Outside air temperature will extremely impact indoor ice conditions. In the same context, winter ice and summer ice in both locations will have the same challenges. Sublimation - changing directly from solid to gas without becoming a liquid, as with Dry Ice. In ice arenas sublimation can take place when the relative humidity falls below 40% RH. This leaves a rough and granular surface on the ice rink. Air/ice interface - when the air above the ice sheet has a dew point temperature higher than the ice surface temperature, moisture from the air will condense on the ice surface (making it frosty). 1

Temperatures We have started to expose the different temperatures found in a typical arena. Outside weather temperature, indoor air temperature, humidity levels, secondary refrigerant temperatures and the actual ice temperature (slab base temperature, ice temperature and slab surface temperature) can all be targeted. Humidity levels the previously described outdoor and indoor temperatures are the root causes to indoor humidity levels. Secondary refrigerant temperatures the setting and controlling of the secondary refrigerant temperatures dictates the ice temperature. Some systems do not have adequate or have poorly operating refrigeration systems that just do not shut off, thus never meeting the set temperature level. This temperature is recorded in the refrigeration room as supply and return temperatures. Outdoor weather conditions can challenge ice conditions and the ice maker in several ways. A building that has all the best equipment can be put to the test when 500 patrons come in to the building during a rain down pour in the parking lot and their clothes are soaked. This moisture will be released along with the energy they exert based on the excitement of the event. Further, fresh air must be circulated throughout the building. The air being drawn into the building, if left untreated through a quality dehumidification HVAC system, will cause the ice maker grief. Warm and cold outside air will contribute to different ice conditions. Indoor temperatures will vary based on building design and use. A building that sits empty with no use can easily be controlled. Turning on the lights, allowing patrons and users in while adding resurfacing water will all contribute to rising indoor air temperature. Ice temperatures readings measure how cold the ice is. These readings can be taken in the concrete slab, in the ice through a probe that is frozen into the ice sheet, or on top of the ice though an infra-red system. Each will vary in temperature but may give you the same ice conditions. A temperature taken in the concrete slab or in the ice sheet may be recorded colder when compared to a surface reading, but the ice maker must understand the insulation factor of the concrete and ice and how it affects the interpretation of the reading. Low E Ceiling: This ceiling material traps heat between the fabric and the roof not allowing heat rays to radiate back onto the ice which in turn reduces the load placed on the refrigeration system. It can also help balance internal air temperatures with the added bonus of increased lighting levels. Common operational mistakes include a facility setting temperatures at the beginning of the season and never adjusting them throughout the year and then wondering why ice conditions change as the season progresses and different events occur. Many of the settings we are about to share are set as start targets, when in fact an ice maker needs to be setting all the equipment to meet these targets at the end of the event not the beginning as ice conditions will deteriorate as the event goes on. 2

Simple operational attitudes such as door openings can significantly impact indoor air temperatures. Too many operators leave large entrance doors open for no reason or use the wrong size door for simple operational tasks as they believe opening the ice resurfacer doors to accept deliveries is easier then a general facility entrance/exit door. Most arenas require 6-8 hours of refrigeration run time to change a temperature by 1-3 degrees. Again, this can be impacted by all the variables we have discussed this far. CIT staff have received sound knowledge on variables that affect ice making. They understand from their training that outside temperatures, inside temperatures, type of ice activity, amount of spectators, spectator heating, all play a factor in maintaining optimum artificial ice conditions! However, they must be committed to applying these skills in the workplace. Having a strong theoretical understanding but failing to apply the knowledge gives no return on training investment. So What are the Best Temperatures? The sliding coefficient between a skate blade and the ice surface are at its best at exactly 28 F. When there are warmer ice temperatures the skate blade cuts deeper, while at colder temperatures friction is also increased due to frost formation on the surface. The constantly changing internal external heat loads on the ice surface cause the temperature on the ice to vary from ideal levels. An ice technician s true skill is the synergy between the "art" of "making ice" with the ice-resurfacer and the science of understanding and controlling ice temperatures! Too many rely on pre-set controls and then wonder why they have poor ice conditions at some events. A community arena strives to be between 50-60 degrees F dry-bulb and 40-50% relative humidity, or a dew point of 32-38 degrees F. Hockey ice surface temperature (22-24F) Public Skating ice surface temperature (24-26F) Other Ice Sports ice surface temperatures (24-26F) Figure Skating ice surface temperature (24-26F) Speed Skating (short track) ice surface temperature (19-21F) Ice Maintenance ice surface temperature (26-28F) Professional curling ice surface temperature - look for an air/ice interface temperature of 24-26 degrees F using demineralized water with a facility temperature of 40 degrees F five feet above the sheet with a relative humidity of 65%. Professional Ice Arenas - are looking for the air conditions in the facility to be maintained 3

between 62 F - 64 F with 40-44%RH and a surface temperature of 22 24F at games end. Secondary Refrigerant Temperatures - some ice makers believe that they can control ice temperature by setting the secondary refrigerant temperatures this is not the best approach to maintaining good quality ice conditions. ORFA CIT training courses may assist you in better understanding this information while helping you create and maintain an exceptional sheet of ice. Ice makers must also understand that secondary refrigerants will vary in temperature depending on the type used. For example, a glycol system will operate at warmer temperatures than a brine system which generally runs 2 to 3 degrees colder than the glycol system Typical brine secondary refrigerant supply temperature is 17-19F Typical brine secondary refrigerant return temperature is 19-21F Other Points to Consider Some facility managers have discovered that how skates are sharpened can impact ice quality. Trying to determine why ice damage is occurring should include skate sharpening hollows as part of an ice technician s investigation. A 5/8 hollow will have less of an impact when compared to a 3/8 hollow. The introduction of harder stainless steel blades has also contributed to an ice maker's challenges. Conclusion A caution is given to all the information you have just reviewed. Undertaking any adjustments must first have the ice technician understand exactly what they are about to adjust! Never consider new adjustments prior to or during significant facility events. Record in detail all adjustments and the result of the adjustments for future references or corrective action. Temperature Adjusting Energy Notes Each Degree Fahrenheit that you raise the ice temperature reduces the load on the ice plant by up to 2 per cent. The drop is because of the combined effects of conductive, convective and radiant heat loads on the ice surface. The higher the ice temperature, the lower the potential for heat transfer. Source: Energy Manual for Arena and Curling Rinks. Saskpower 2006 Increasing the ice temperature during times that there is to be no use (8+hours) has several benefits. Ice temperatures in some facilities are increased to as much as 28 F. This saves energy and also tempers the ice making it more durable resulting in less ruts and chips which requires less maintenance. 4

Additional Information and Resources to this Document EnergyIce provides 1. http://www.customicerinks.com/energyice/press 4.htm 2. http://www.customicerinks.com/energyice/press 3.htm Icekube Systems Thermal Energy Storage http://www.icekubesystems.com/htmlfiles/therma l-energy.asp Cimco Refrigeration http://www.cimcorefrigeration.com/pdf/cimco% 20Ice%20Rink%20Controllers.pdf 2. http://www.cimcorefrigeration.com/ice_articles_0 4.asp Energy Management manual for Curling and Ice Rinks (SaskPower) http://www.saskpower.com/pubs/energy_manag ement.shtml CETC Varennes (NRC) Factsheet on Controlling Ice Temperature (utilizing energy conservation methods) http://cetcvarennes.nrcan.gc.ca/fichier.php/codectec/en/2 003-066-6/2003-066-6f.pdf Disclaimer Ontario Recreation Facilities Association Inc., 2009 The information contained in this reference material is distributed as a guide only; it is generally current to the best of our knowledge as to the revision date, having been compiled from sources believed to be reliable and to represent the best current opinion on the subject. No warranty, guarantee or representation is made by ORFA as to the absolute correctness or sufficiency of any representation contained in this reference material and ORFA assumes no responsibility in connection therewith; nor can it be assumed that all acceptable safety and health measures are contained in this reference material, or that other or additional measures may not be required in particular or exceptional conditions or circumstances. While ORFA does not undertake to provide a revision service or guarantee accuracy, we shall be pleased to respond to your individual requests for information at any time. Reference to companies and products are not intended by the publisher as an endorsement of any kind. The Ontario Recreation Facilities Association T. 416 426 7062 F.416 426 7385 www.orfa.com info@orfa.com To purchase ASHRAE Refrigeration Handbook [Chapter 35: Ice Rinks] http://resourcecenter.ashrae.org/store/ashrae/ne wstore.cgi?itemid=28125&view=item&page=1&l oginid=27100463&priority=none&words=ice%20 rinks%2034&method=and Mr. Hans Wuthrich Curling Ice Professional Mr. Dave Loverock Jet Ice Ltd 2008 ORFA Arena Technical Advisory Committee 5