Instruction Manual Reach-In Refrigerators & Freezers

Similar documents
G1F-23-B-1 G1F-23-W-1

OWNER S MANUAL STAINLESS STEEL REACH-IN SERIES. Model: ATF1 ATF2 ATF3 ATR1 ATR2 ATR3 ATF2 ATR2

PREP TABLES AND UNDERCOUNTER REFRIGERATION INSTRUCTION MANUAL

Chef Base Refrigerators

Sandwich/Salad Table Under-counter Refrigerator Worktop Refrigerator

INSTRUCTIONN MANUAL. for Angle Curved MMF9106 MMF9109 MMF9112

Solid Door Top Mount Reach-In Freezer

Instruction Manual. 4.6 Cu. Ft. Refrigerator/Freezer. Wards.com Wards.com The solution for your cold-storage needs!

Upright Chiller & Freezer Service, Installation and Care Manual

Glass Door Merchandiser Refrigerator and Freezer

Instruction Manual. Compact Portable Ice Maker. Wards.com Enjoy cold, refreshing ice in just 13 minutes

Table of Contents Welcome and Thank You Note:

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

Instruction Manual MODEL: GDUF Cu. Ft. Capacity 120V~, 60Hz, 115W

INSTRUCTION MANUAL. UNDERCOUNTER WINE & BEVERAGE COOLER (32 bottles capacity) MODEL:WC-30U

COMPACT REFRIGERATOR

Installation and Operation Guide For

Glass Door Refrigerators

Use and Care Manual. Flammable Material Storage Refrigerator LRBFS06W1HC

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

REFRIGERATOR with CHILLER COMPARTMENT

BOTTOM MOUNT REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

User Manual / Installation Instructions

User Manual. Commercial Reach-In Refrigerators: RF-1D, RF-2D, RF-3D. Commercial Reach-In Freezers: FZ-1D, FZ-2D

BEVERAGE MERCHANDISERS Instruction Manual

CHEST FREEZER INSTRUCTION MANUAL. Model No.: EWCF5WBX EWCF7WBX

HOUSEHOLD REFRIGERATOR-FREEZERS

Use and Care Manual. For Beverage Cooler RU

4.5 CU.FT. REFRIGERATOR INSTRUCTION MANUAL

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS REFRIGERATORS OPERATING INSTRUCTIONS

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

OWNE R S MA N UA L. Made in USA. September 2015

UPRIGHT FREEZER WHS-502FWEW1(E) WHS-502FWEB1(E) WHS-502FWESS1(E)

Instruction Manual. Beverage and Wine Center. Wards.com Sleek and compact MODEL: GDBC47

SAVE THESE INSTRUCTIONS HOUSEHOLD USE ONLY

Instruction Manual Item No.: V~, 60Hz

INSTRUCTION MANUAL (UNIT APPEARANCE MAY VARY FROM IMAGE) BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

COMMERCIAL REFRIGERATORS, STAINLESS STEEL PRODUCTS OPERATING INSTRUCTIONS

XC Portable Air Conditioning

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

AB Can Beverage Cooler

HT-MOSEL-51D PLEASE READ THIS MANUAL CAREFULLY BEFORE USING THE WINE CHILLER

TWO-ZONE WINE COOLERS

Instruction Manual. Toolbox Fridge. Wards.com Perfect for the man cave or workshop MODEL: SC50C-2. Item No.: V~, 60Hz, 76W

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

USE AND CARE GUIDE COMBINATION KITCHENS. C301 Series C301 AUTO Series C39 Series C39 AUTO Series C48 Series C60 Series

Ui REFRIGERATOR SPEC SHEET

Instruction Manual Item No.: V~, 60Hz

INSTRUCTION MANUAL. Model Number: AR52T3SB BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

IMPORTANT PLEASE RETAIN FOR YOUR RECORDS

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

Glass Door Undercounter and Countertop Freezers

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

INSTRUCTION MANUAL BUILT-IN DUAL-ZONE WINE COOLER MODEL:AWR42-2DZ

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Operator s Manual. IP-100 Immersion Probe Cooler

ALL-REFRIGERATOR FF521BL CM411L FF521BLBI SCR450L SCR450LBI SCR500BL SCR500BLBI CM421BL. Owner's Manual

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

AB Can Beverage Cooler

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

OPERATION MANUAL. CLASSIC 10 and CLASSIC 18. Unit Serial Number Range: 1111XXXX### to Present (From November 2011 to Present)

Installation & Operation Manual Undercounter & Prep. table units

Use and Care Manual. Beverage Cooler RU

User and Installation Instructions C6R/75, C6R/100, C6R/105, C6R/125, C6R/130, D6R/100, D6R/125, D5R/100, D5R/125, D3R/100

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.

Industrial Dehumidifier Operating Instructions. Model: VG 1500

VR60 GLASS FROSTERS INSTALLATION AND OPERATING MANUAL PLEASE LEAVE WITH OPERATOR. VR60 Glass Froster. Series 1

200L Chest Freezer / GVATCS20Q. Instruction Manual

CONTENTS. 1. Safety recommendations 2 Table of warning and attention plates 3. Description of the unit 4. Operation 5. Handling

BAR FRIDGE 118 & 228 LITRE

Owner s Manual for Swimming Pool Heat Pump

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

Split Portable Air Conditioner

UNDERCOUNTER LABORATORY FRONT BREATHING REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

1.7 CU.FT. REFRIGERATOR INSTRUCTION MANUAL MCBR170BMD

REFRIGERATED CONDIMENT RAIL

RPI Industries, Inc.

UPRIGHT FREEZER FSA14921

2.4 Cu. Ft. Compact Refrigerator

Dual Zone Wine Cellar

BEFORE FIRST USE: TABLE OF CONTENTS

HTD. High Temperature Non-Cycling Refrigerated Compressed Air Dryers. Operation & Maintenance Manual. MODELS HTD 21 thru HTD 100

INSTRUCTION MANUAL COMMERCIAL GRADE KEGERATOR MODEL:XCK-1

InstructIon Manual KrEs EQuIPMEnt stands

DEHUMIDIFIER. User Manual 50BT, 70BT

NON-CYCLING REFRIGERATED AIR/GAS DRYERS QPNC 75 to QPNC 250 OPERATOR S MANUAL

Owner s Manual Refrigerated Compressed Air Dryers Models F-3528, F-3529, F-3530, F-3531 & F-3532

OPERATING INSTRUCTIONS

User and Installation Instructions. Seal Refrigerated Merchandisers

Instruction Manual. Please read these instructions and the Safety section carefully before using your refrigerator.

BACK BAR REFRIGERATION Installation, Operation and Maintenance Instructions

Quest Dry 150 Dual. quest Asset Protection and IAQ Solutions. Read and Save These Instructions. Installation, Operation and Maintenance Instructions

UNDERCOUNTER REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

DWC-063RL ROOM AIR CONDITIONER USE & CARE MANUAL MODEL #: DWC-055RL S/N : WINDOW TYPE ROOM AIR CONDITIONER

OPERATING AND MAINTENANCE MANUAL SERVICE CENTRE AUTHORIZED DEALER. Ed. 02/2012 PANCAKE OVEN

Transcription:

Instruction Manual Reach-In Refrigerators & Freezers Models: R1R-1 R2R-1 R3R-1 F1R-1 F2R-1 F3R-1 Supera Customer Care Toll-Free Service Line: 1-866-953-3288 For additional product and warranty information, please visit our website at www.superaco.com

Table of Contents: 1) Introduction... 2 2) Use of the equipment......2 3) Technical features... 3 4) Operation... 3 5) Control unit... 3 6) Handling... 4 7) Installation procedure... 4 8) Connecting to the main power supply... 4 9) Maintenance instructions... 6 Cleaning... 6 Cleaning the refrigerator surface... 6 Cleaning the inside of the refrigerator... 6 Cleaning the condenser... 6 10) Troubleshooting... 7 11) Technical service... 7 12) Configuration Sketch Map... 7 Operating Instructions... 8 Electrical Control Circuit Diagram... 10 Technical Parameters... 11 Wiring Diagram.... 12 Official Approval And Rules....13 Page 2

1. Introduction This instruction manual provides all the necessary information regarding: Use of the refrigerator Technical specifications Installation and handling Operator procedures and instructions Maintenance operation The manual is to be considered an integral part of the refrigerator and should be stored in a safe place for further consultation for the working life of the refrigerator. The manufacturer cannot be held liable in the following cases: Improper installation (not in accordance with the guidelines indicated herein) Misuse of the refrigerator Power supply defects Improper or inadequate maintenance Unauthorized modification or tampering Use of non-original (NON-OEM) spare parts Partial or total failure to comply with the instructions All electrical equipment can be hazardous to health. Current standards and legal requirements must be complied with during the installation and use of any equipment. 2. Use of the Equipment The refrigeration units are for preserving fresh perishable foodstuffs, with a built-in refrigeration unit. The operating temperature for refrigeration is: Between 45 F and 33 F at room temperature of 109 F and 60% RD The operating temperature for frozen food maintenance is: Between -1 F and -8 F at room temperature of +109 F and 60% RD Page 3

3. Technical Features The refrigerator is a ventilated system; the evaporator is in a separate insulated box on the top. All the materials used in the manufacture of this unit are guaranteed to be suitable for use with foodstuffs. The gases used in the refrigerator are R134a; in the freezer for frozen food maintenance is R404a. The refrigerating circuit is in compliance with the current industry standards. 4. Operation The gas in the refrigerating circuit is first compressed, liquefied and then evaporated in the ventilated evaporator, situated on the top of the refrigerator. This cycle involves the absorption of heat from the air in the refrigerator compartment. The heat produced is then dissipated to the outside environment by a condenser unit located on the top of the refrigerator. 5. Control Unit A digital control unit and a main switch pilot light in the top panel of the refrigerator operate the refrigerator. The main switch pilot light is for turning on the power supply. The green pilot light comes on to indicate that the unit is connected to the main electricity and to start operation. The green pilot light comes off to indicate that the unit is disconnected and is not operable. The digital control unit is for the regulation of all parameters to provide the correct operation of the refrigerator. Please consult all parameters in the digital control unit section of this manual. Page 4

6. Handling The refrigerator arrives in PET film and packed in a cardboard box on a wood pallet.! The refrigerator must be transported and handled with care to avoid posing a hazard to persons or property. Never place a refrigerator with a built-in refrigerated unit on its side or turn it upside down as this may damage or impair operation of the refrigerated unit. Supera cannot be held liable for any damage or defects arising directly or indirectly from improper handling of the equipment or non-compliance with the safeguards illustrated above. 7. Installation Procedures Place the refrigerator in the coolest and best ventilated part of the room. Don t install the refrigerator near heat and direct sunlight sources. Remove the straps securing the cardboard packing. Remove the cardboard covering. Remove the PET protection film. Clean the refrigerator with mild detergent and then dry it with a soft cloth. 8. Connecting to the Main Power Supply Qualified professionals must carry out this operation.! The refrigeration units are supplied complete with a power supply cable for the connection to the main power supply. A thermomagnetic circuit breaker (not supplied) must be installed between the mains power point and the power supply cable of the refrigerator. Before proceeding make sure that: The main voltage corresponds to the voltage on the refrigerator 115V/60Hz/1Ph; to ensure proper operation it is essential for the power supply voltage to come within a range of +/-10% of the unit's rated voltage Page 5

The electric system to which the refrigerator is sized to cater for the rated electric output of the buffet unit being installed The electronic system to which the refrigerator is connected is made in compliance with current standard requirements The electric connections and the installation of the thermomagnetic circuit breaker have been done by qualified professionals Connecting steps: Install a thermomagnetic circuit breaker suited to the rated output of the unit being installed Connect the refrigerator unit to the thermomagnetic circuit breaker outlet Check that the refrigerator is in order as demonstrated by the pilot light incorporated in the main switch coming on 9. Maintenance Instructions The smooth operation and life of the equipment are mainly determined by correct and regular maintenance. Cleaning: Regular cleaning of the refrigerator unit is strongly recommended each month. Please follow the instructions below.! Disconnect the refrigerator power supply cable from the mains prior to carrying out any type of cleaning operation. Cleaning the refrigerator surface: Clean the refrigerator with mild detergent and then dry it with a soft cloth. Do not use abrasive detergents! Cleaning the inside of the refrigerator: Clean the inside area at a minimum of each month with a detergent suitable for use with foodstuffs. Cleaning the condenser: For an efficient operation of the refrigerator, it is advisable to clean the condenser regularly approximately every 4 months with a dry brush or vacuum cleaner. Page 6

10. Troubleshooting Refrigerator stops working (light off): Power supply failure Remedies: Check that the plug is inserted properly Check that the on/off switch is set to on Check that the mains voltage power is on Refrigerator temperature increases: Unit too near to a heat source Condenser dirty or closed Remedies: Move the counter or the heat source further away Clean the condenser 11. Technical Service For technical service, please contact the Supera Service Department and give them the serial number and the date of purchase. 12. Configuration Sketch Map 1. Power Switch 4. Evaporator 7. Condenser 10. Lamp 2. 5. 8. 11. Microcomputer Controller Evaporator Fan Motor Drain Case Casters 3. Compressor 6. Condenser Fan Motor 9. Shelf Page 7

OPERATING INSTRUCTIONS 1. New, upright air-cooling refrigeration unit should be opened and ventilated before it is in use. After that, users should use warm water clean the interior. 2. After connecting the power supply, press the POWER switch on the controller keyboard (Green Indicator Light ON) and the refrigeration unit s power will turn on. The microcomputer controller, installed in the controller keyboard, can automatically adjust the temperature ranges. This intelligent digital controller works as such: If the temperature increases and reaches set point plus differential, the compressor is started and then turned off when the temperature reaches the set point value again. FRONT PANEL COMMANDS Digital Control Unit To display target set point, in programming mode it selects a parameter or confirm an operation. To start a manual defrost. In programming mode, it browses the parameter codes, or increases the displayed value. In programming mode, it browses the parameter codes, or decreases the displayed value. KEYS COMBINATION To lock or unlock the keyboard. To enter in programming mode. To return to room temperature display. Page 8

How to See the Set Point: 1. Push and immediately release the SET key, the set point will be shown. 2. Push and immediately release the SET key or wait about 5s to return to normal visualization. How to Change the Set Point: 1. Push the SET key for more than 2 seconds to change the Set point value. 2. The value of the set point will be displayed and the C or F LED starts blinking. 3. To change the Set value push the or arrows. 4. To memorize the new set point value push the SET key again or wait 10s. How to Start a Manual Defrost: Push the DEF key for more than 2 seconds and a manual defrost will start. How to Change a Parameter Value: To change the parameter s value operate as follows: 1. Enter the Programming mode by pressing the SET + keys for 3s ( C or F LED starts blinking). 2. Select the required parameter. Press the SET key to display its value. 3. Use or to change its value. 4. Press SET to store the new value and move to the following parameter. To Exit: Press SET + or wait 15s without pressing a key. NOTE: The set value is stored even when the procedure is exited by waiting the time-out to expire. To Lock the Keyboard: 1. Keep pressed for more than 3s the + keys. 2. The OF message will be displayed and the keyboard will be locked. 3. If a key is pressed more than 3s the OF message will be displayed. To Unlock the Keyboard: Keep pressed together for more than 3s the message is displayed. + keys till the on Page 9

Alarm Signaling Our products have been modified precisely before leaving factory, so to avoid damaging compressor unit or other malfunctions; users must not modify microcomputer parameters privately. Page 10

TECHNICAL PARAMETERS Prevention Product Model Type Name class of Power getting an Supply electric (V/Hz/Ph) Ampers Temperature Range(F) Refrigerant Dimensions (inches) Net Weight (lb.) shock Single-door Refrigerator Two-door Refrigerator Three-door Refrigerator Single-door Freezer Two-door Freezer Three-door Freezer R1R-1 I 115/60/1 3.5 33 40 R134a 28.7x33.3x83.9 254 R2R-1 I 115/60/1 5.6 33 40 R134a 51.7x33.3x83.9 419 R3R-1 I 115/60/1 7.6 33 40 R134a 77.8x33.3x83.9 617 F1R-1 I 115/60/1 6.7-8 -1 R404a 28.7x33.3x83.9 265 F2R-1 I 115/60/1 10.3-8 -1 R404a 51.7x33.3x83.9 441 F3R-1 I 208/60/1 9.6-8 -1 R404a 77.8x33.3x83.9 617 Page 11

Page 12

OFFICIAL APPROVALS -Conforms to UL STD. 471 -Conforms to NSF 7 -Certified to CSA STD. C22.2 NO. 12O A product with the SUPERA name incorporates the best in durability and low maintenance. We all recognize, however, that replacement parts and occasional professional service may be necessary to extend the useful life of this unit. When service is needed, contact a SUPERA Authorized Service Agency, or your dealer. To avoid confusion, always refer to the model number, serial number, and type of your unit. Supera Customer Care Toll-Free Service Line: 1-866-953-3288 For additional product and warranty information, please visit our website at www.superaco.com Page 13