Detection of Inherent and Laser-Induced Scatter in Optical Materials

Similar documents
A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

THERMAL VACUUM TESTS OF A FIVE WATT PSEUDO CHIP SEM-X ELECTRONIC MODULE CLAMPED IN A SATELLITE BOX

Food Service Technology Center

FINAL ABSTRACT. CRADA TITLE. Miniature Transducers for Flight Test Unit Instrumentation - Magnetic Field Detector CRADA NUMBER: LA98C10367.

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

A FIRST RESPONDERS GUIDE TO PURCHASING RADIATION PAGERS

Title Page. Report Title: Downhole Power Generation and Wireless Communications. for Intelligent Completions Applications

Report on the Suitability of Class 6, U.S. Government Security Repositories for the Storage of Small Quantities of High Explosives

W. T. Roybal J. T. Bradley III D. E. Rees P. Torrez D. K. Warner J. Debaca. LINAC 2000 Monterey, CA August ,2000

Why Thermostats Matter

p?:uam SYSTEMS Technical Progress Report Jane H. Davidson NAllJRAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING February 1,1996 to March 31,1996

NATURAL CONVECTION HEAT EXCHANGERS FOR SOLAR WATER HEATING SYSTEMS. Technical Progress Report April 1,1995 to May 31,1995

/,6 REMOTE MONITORING DESIGN CONCEPTS FOR SPENT FUEL STORAGE FACILITIES

Lawrence Berkeley National Laboratory Lawrence Berkeley National Laboratory

Laser Safety Products. Edition 20

Application Note. Which characterization method is best for your application? The Future of Thermal Imaging is Here!!!

Why is Laser Safety Important Laser usage is growing rapidly e.g. laser points, CD/DVD, industrial applications Heavy use now in laboratories for

Electronic Refrigerant Leak Detector DE-FG36-98G Micronic, Inc. Elie Talamas, Jr. Period: 10/1/99 to 12/31/99

Why is Laser Safety Important Laser usage is growing rapidly Industrial applications Heavy use now in laboratories for research, analysis Many

PM-200 Power Module Operating Instructions

This document is downloaded from DR-NTU, Nanyang Technological University Library, Singapore.

Food Service Technology Center

High-Altitude, Aerial Natural Gas Leak Detection System

TSI AEROTRAK PORTABLE PARTICLE COUNTER MODEL 9110

Understanding total measurement uncertainty in power meters and detectors

WHAT IS LASER ULTRASONIC TESTING?

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Los Alamos NATIONAL LABORATORY. A Review of Acceptance Testing of t h e. Continuous Air Monitor (CAM)

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

New Construction Builders Challenge: Sealed Attic and High Efficiency HVAC in Central Florida: A Year in Review

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

Sunglo Heater Model A270 Patio Heater Performance Test

LASER SAFETY BARRIER

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

CALIBRATION HOW IT WORKS

Turning Inspection Regulations into Training Tools

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Establishing a Center of Excellence for. Security Science and Engineering

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

CART and GSFC Raman Lidar Measurements of Atmospheric Aerosol Backscattering and Extinction Profiles for EOS Validation and ARM Radiation Studies

Content. Laser physics Laser treatment parameters Laser safety. by Fotona d.o.o., 2017

BOP Ram Sensing and Interface Concept Rationale Intelligent BOP RAM Actuation Sensor System

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Food Service Technology Center

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

PlateScrape Plate Pre-Scrapper Test Report

Sunpak Heater Model S25 Patio Heater Performance Test

Laser Damage Measurements

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

SPECTRAL INSTRUMENTATION

Surface Mount 905 nm Pulsed Semiconductor Lasers High Power Laser-Diode Family for Commercial Range Finding

Southern California Gas Company Customer Programs Department

Laser Radiation and High Voltage/Electrical Shock. Disclaimer and Limitation of Liability. Shipping Damage. Trademarks

Wilcom. Model FR2 Fiber Ranger Optical Fault Locator OPERATING INSTRUCTIONS

F Prepared by: Kong Sham. Prepared for: PO Box Technology Center

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

onlinecomponents.com

Customized LIDARs. Research Pollution Climate. Raman, Depolarization, Backscatter, DIAL

Polarized Light Scattering of Smoke Sources and Cooking Aerosols

An FT-NIR Primer. NR800-A-006

ISO/TS TECHNICAL SPECIFICATION

ISO Acceptance tests for Nd:YAG laser beam welding machines Machines with optical fibre delivery Laser assembly

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

DETECTION AND LOCALIZATION OF MICRO AND MULTIPHASE LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

Optical Time Domain Reflectometry (OTDR)

Measuring Couch Motion Accuracy with X-ray Beam Fluence

HELPCOS THE HELICOPTER BASED PIPELINE CONTROL SYSTEM OF VNG - VERBUNDNETZ GAS AG

International comparison of validation methods for dust concentration measurement

MicrOTDR. Optical Fault Locator. User Manual

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Food Service Technology Center

FLIM/FFS and Nanoimaging Upgrade of Olympus confocal microscopes

DEVELOPMENT OF THE INFRARED INSTRUMENT FOR GAS DETECTION

NX8601BF-AA. Data Sheet R08DS0109EJ0100 Rev.1.00 Apr 19, 2013 LASER DIODE DESCRIPTION FEATURES

Publication American Institute of Physics. Reprinted with permission.

Food Service Technology Center

AN10943 Decoding DTMF tones using M3 DSP library FFT function

Detection of Solvents using a Distributed Fibre Optic Sensor

XEUS mirror calibration:

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

Certificate: _01 / 22 March 2013

Beam Analysis nm and µm - Pyroelectric Array Camera. Pyrocam TM IIIHR & Pyrocam IV Series

Engineering Laser Safety into the Raman Gas Analyzer for Industrial Applications

Recent Progress in Lightwave Sensing Technology

Laser Series. Highly Visible Alignment Lasers For Visually Demanding Surfaces

STER 1981 ANNUAL INDUSTRIAL SUMMARY OF FIRE AND PROPERTY DAMAGE EXPERIENCE. Monsanto. MOUND FACILITY Miemisburg. Ohio MLM.ML

mach 5 100kHz Digital Joulemeter: M5-SJ, M5-IJ and M5-PJ Joulemeter Probes

Distributed Temperature Sensing

Beam Loss Position Monitoring with Optical Fibres at DELTA

PERGAM GAS LEAK DETECTION

Laser Weld Keyhole Dynamics and Control. M. H. Cho, D.F. Farson Welding Engineering Department, The Ohio State University, Columbus, Ohio

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

Standard Operating Procedure LIGO 700 mw NPRO Laser in Optics Laboratory

Compact Raman spectrometer system for low frequency spectroscopy

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

Transcription:

UCRL-JC-119613 PREPRINT Detection of Inherent and Laser-Induced Scatter in Optical Materials L. Sheehan M. Kozlowski This paper was prepared for submittal to the Society of Photo-Optical Instrumentation 1995 International Symposium on Optical, Science, Engineering and Instrumentation Tuscon, Arizona, July 9-14,1995 July 5, 1995 Thisisa preprintof a paperintendedforpublicationinajournalorproceedingssince changes may be made before publication, this preprint is made available with the understandingthat it will not be cited or reproduced without the permission of the author. DlSTRl6UTlON OF THIS DOCUMENT IS UNLIMITED

DISCLA JMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, make any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

DISCLAIMER Portions of this document may be illegible in electronic image products. Images are produced from the best available original document.

Detection of Inherent and Laser-Induced Scatter in Optical Materials Lynn Sheehan, Mark Kozlowski Lawrence Livermore National Laboratory P.O. Box 558 L-484 Livermore, California 9455 key words: scatter mapping, delta scatter, delta average scatter, optical coatings, laser-induced damage Introduction * As Lawrence Livermore National Laboratory moves forward with the design of the National Ignition Facility (NE)in the Inertial Confinement Fusion (ICF) program, issues relating to the detection and measurement of laser-induced damage on large optics must be addressed. Currently, microscopy is used to evaluate surface quality and measure damage thresholds on small witness samples. In order to evaluate large areas, an automated system was constructed which can scan optics with dimensions as large as 1meter and weighing as much as 4 pounds. The use of microscopy as the main test diagnostic has been replaced with an optical scatter detection system. Now large areas can be rastered, and maps can be generated, reflecting inherent and laser-induced scatter in multilayer optical coatings and bulk materials. The integrated scattered light from a test piece is measured in transmission using a HeNe laser as the probe source. When the probe beam is overlapped on a pulsed, high power, NdYAG laser beam, damage related scatter may be measured. This technique has been used for: 1) mapping of inherent scatter in an optic, 2) on-the-fly damage detection during a high fluence raster scan of an optic, and 3) single site damage evaluation for the determination of a laser damage threshold. Damage thresholds measured with the scatter diagnostic compare within measurement error to those attained using 1 x microscopy. Scattered light measurement system The current scatter measurement system is installed on the Large Area Conditioning facility at LLNL(1). This faality allows raster scanning samples up to 1 meter in size with a high power Nd:YAG laser (Fig. I). By integrating the scatter diagnostic onto this system, both inherent and laser-induced scatter phenomenon can be studied on small and large areas.

t I I I \. \ Fig. 1 The scatter measurement diagnostic has been integrated into the existing Large Area Conditioning system at LLNL. The scatter measurement system is similar to what has been evaluated within the damage community in the past.(2/3/415)a 35 mw HeNe laser beam is sized such that its beam is larger than the damage test beam on the sample surface. The scatter detection system blocks the transmitted HeNe probe beam at a focus. Scattered light from the sample surface focuses beyond the beam block and is collected onto a silicon photodetector (Fig 2). In this system the spatial resolution limit is-approximately1 jun to 2 pm due to the collection angle of the optical system. The photodetector signal is amplified and filtered before being read by a computer controlled data acquisition system. There are 3 specific scatter measurements made with this system. The first is the mapping of both the inherent and laser-induced scatter from an optic. The second is a measurement of change in scatter based on 2 scatter measurements at the same site, for use in detection of laser-induced damage. This measurement can detect damage at each site on-the-fly during a raster scan. The third measurement is a delta scatter measurement based on averaging of 1 total measurements per site in order to reduce background noise effects. The graphical depiction of these measurements and the related equations and definitions of the measurements are shown in Fig. 3.

M Telescope Spatial Filter Fig. 2 Layout for measurement of optical scatter. a) Scatter mapping: raster scan sample high / scatter L Lu/ Bm / b) Delta scatter: -- S(after) - S(before) = A S I I low scatter L u e r puke Sbefore 5 meas. Time I Safter 5 meas c) Deltaaverage scatter: Average 1 measurementsto reduce background noise effects Avg S(after) - Avg S(before) = AAvg S Fig. 3 The present scatter diagnostic system is capable of measuring both intrinsic and laser-induced scatter on single sites, or over large areas Details of scatter light detection system In order to understand the efficiency of this initial system, a detailed layout and subsequent CODE V modeling is presented. Fig. 4 shows a more.detailed layout of the optical components that make up the transmissive scatter measurement.

Photodetector bandpassfilter nm block filter 88 S Fig. 4 Detailed layout of the transmission scatter measurement The parameters of the optical components are shown in Table 1. The separation column represents the distance from the previous component to the listed component, where the sample surface is zero. So L l is 265 mm from the sample surface, and L2 is 8 mm from the center of Ll,and so on.. The Fig. 5 displays the Code V raytrace of the scatter detection system. The calculated magnification was about 1.6, so the field of view (FOV) at the sample surface is 16 mm. The largest high power beam diameter is 6.5 m.

Fig. 5 Code V raytrace of high-angled scattered light through optical detection system Scattered light detection results Scatter mapping An example of the scatter mapping capability of the system is shown in Fig. 6. Shown is the inherent scatter signature of a 74 an x 36 cm HfO~/Si2polarizer. In the map, many scatter signal sources can be identified: rear surface contamination, pinpoint defects, substrate artifacts, and also coating uniformity at normal incident 632 nm wavelength transmission. Delta scatter mapping on-the-fly The AS measurement is used during our laser conditioning process to identify small pinpoint damage that may occur. This measurement evaluates each irradiated site on the optic for damage. When a raster scan of an optic is complete, a map of the detected damage sites is available. By calibrating the AS measurement to the detected damage diameter, a estimate of the damage incurred at each of these sites on the optic during conditioning can be made. A map of damage incurred during s c m of a polarizer coating are shown in Fig. 7. The first map of damage sites Fig. 7 a) was from a scan of the optic just above its damage threshold, and showed only a few damage sites. In Fig. 7 b) the fluence was twice the damage threshold of the coating, and many damage sites are detected. Since the coordinates of each of the detected sites is known, microscopic analysis of sites of interest can be made.

Substrate contamination Pinpoint d efiects Coating uniformity at 632 nm 9 Y) m. 4. 735. 6. x dimension (mm) Rear surface d contamination.2.4.6.8 Scatter signal (volts).1 Fig. 6 By mapping the scatter signal from the entire optic, a variety of scatter sources can be seen. This map of a 74 cm x 36 c m polarizer shows the inherent scatter sources of a large optic. 6 5 4 3 6 5 4 3 2 1 2 1 2 4 6 8 2 4 6 8 Fig. 7 Map of damage sites detected by AS measurement during a raster scan at a) 9.1 J/d and b) at 16.8 J/cm2, a fluence that is 2x the damage threshold of the coating

There is some amount of difficulty in relating the detected scatter signal to the damage size or morphology. The three main artifacts found during this work are shown in Fig. 8. The first is the different inherent scatter properties of damage spots with the same diameter. With the microscope they look similar, but the detected scatter signal is different. The second artifact is the influence of the gaussian spatial shape of the HeNe probe beam and the location of the damage site. The scatter signal level will be less if the damage point is in the wings of the profile versus the peak. The third is that the scatter signal for large damage points and clusters of small damage points may be similar. Fig. 9 shows the relation between AS and the size of damage observed. The data can be used to provide a indication of the size of damage, but not an absolute value. Delta average scatter measurement The data shown in Fig: 1 shows the measured relationship between the detected damage diameters and the scatter signal. The detected damage is determined by summing all of the diameters of the damage points at a site and this is plotted against the AAvgS as defined above. There was an increasing trend of the AAvgS with increasing damage diameter. The smallest detected damage point was 1 pm in diameter. Determining damage thresholds Using both the AS and AAvgS measurements, damage thresholds of optics can be determined. A plot of damage thresholds of Hf2/Si2,164 nm mirror and polarizer coatings, identified by sample number, is shown in Fig. 11. Plotted are the damage threshold (51) results found using 1OOx nomarski microscopy, 8x standard backlite microscopy, AS, and AAvgS. The correlation of the scatter measurement techniques to microscopy where well within the k 15 % measurement error bars. The only notable difference between the two scatter measurement techniques is found on sample numbers PO27 and P29. For these particular samples, the damage threshold was based on small pinpoint damage. The damage morphology was small pinpoints up to much higher fluences. Since the AS measurement is not as sensitive to very small pinpoints as the AAvgS technique, its determined threshold was higher. Even with different resolution limits, both techniques compared well to microscopy.

qy51 1. Each damage tito may havr a different Inherent scatter'rignature,aven if they are the same oka Oa agr ----- -- Signal t 7 mv Diagnostic Beam -- - Signal ~ 9 mv -. 2. Placomant ofthe damage In tho detectbn beam mayglve different lntenstty values 3. Damage made up of many pinpoints may look like one large damage site i n t h e scatter measurement Fig. 8 There are several artifacts that make the correlation of scatter to damage morphology difficult. 7 2 4 6 8 1 12 Damage diameter (pm) detection limit of AS system = 15 pm Fig. 9 The AS diagnostic provides some indication of the size of the damage incurred during a scan

TatalDamage (pn) Fig. 1 There is some correlationbetween damage diameter and the change in scatter signal measured S:l8x standard microscopy Po9 Po18 WO26 Sample ID W27 Po28 Fig. 11. Both delta scatter and delta average scatter measure damage thresholds of thin films within error of loox nomarski microscopy. PO29

Conclusions An optical system has been demonstrated which can measure the integrated scatter from optical components in transmission. The system is capable of mapping inherent and laser-induced scatter in meter-sized optical components. A detailed design and results demonstrate the scatter collection system capabilities for such applications. The technique is capable of measuring scatter sources as small as 1-2 pm in diameter. When used to conduct measurements of laser damage thresholds of optical coatings, the results compare to those achieved with loox microscopy. References 1. Sheehan, L. et al., 'ZargeArea Conditioning of Optics for High-Power Laser Systems", Laser Induced Damage in Optical Materials: 1993, SPIE vol. 2114, 559,1994. 2. Mann, K. Gerhardt, H., "Setup of a Damage Testing Facility for Excimer Laser Radiation", SPIE vol. 123,136,1989. 3. Seitel, S., Babb, M., 'Zaser-Induced Damage Detection and Assessment by Enhanced Surface Scattering", Laser Induced Damage in Optical Materials; 1986, NBS Spec. Pub. 752,83,1987. 4. Frank, J., et al., "Automated Pulsed Testing Using a Scatter-Probe Damage Monitor", Laser Induced Damage in Optical Materials; 1984, NBS Spec. Pub. 727,71,1985. 5. Moran, M., Kuo, R, Marrs, C., "Scatter Intensity Mapping of Laser-Illuminated Coating Defects", Laser Induced Damage in Optical Materials; 1986, NBS Spec. Pub. 752,235,1987. r h j s work was performed under the auspices of the U.S. Department of Energy by LawV3nce Livemore National Laboratory under contract No. W-745-Eng-48.