NFPA Edition. NFPA 13 (2016 Edition) Hot Topics and NFPA 13 FAQ s. Highlights of 2016 Changes. Storage Commodity Classification 4/29/2014

Similar documents
Fire Prevention Coffee Break Training. May 2017

Storage Protection Using Horizontal Barriers and Large K-Factor, Extended Coverage In-Rack Sprinklers

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

Protection of Rack Stored Exposed Expanded Group A Plastics with ESFR Sprinklers and Vertical Barriers

PLAN REVIEW CHECKLIST

Box-in-Box Cold Storage Fire Protection Options

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

Storage Sprinkler U.S. Quick Reference Guide

esfr pendent sprinkler vk510 (k25.2)

esfr pendent sprinkler vk510 (k25.2)

Sprinkler Standards Proposed Technical Changes

ESFR PENDENT SPRINKLER VK510 (K25.2) TECHNICAL DATA

TECHNICAL DATA OBSOLETE. * Refer the Approval Chart on page 121c and Design Criteria on page 121d for FM approval requirements that must be followed.

TECHNICAL DATA OBSOLETE

NFPA Edition Update

Tire Storage. Michigan Fire Inspectors Society Fall Conference

NFPA 25 and the Influence of Liability

Plan Submittal Checklist

TECHNICAL DATA. * Refer the Approval Charts and Design Criteria on pages 3-5 for culus Listing and FM Approval requirements that must be followed.

FIRE SPRINKLER SYSTEMS POLICY

TECHNICAL DATA. Refer to the Approval Chart and Design Criteria for UL and FM Listing/Approval requirements that must be followed.

esfr dry pendent sprinkler Vk501 (k14.0)

SFPE Austin/San Antonio Chapter Meeting

FIRE SPRINKLER SYSTEMS POLICY

esfr dry pendent sprinkler Vk502 (k14.0)

Sprinkler Permit Applications

Annual Report of Inspection, Testing & Maintenance of Automatic Sprinkler System

Storage Sprinkler. Model LP-46 (SIN) V4603, K25, Standard Response Storage Upright Sprinkler, Patent Pending

Montgomery County Government Building and Codes Department 350 Pageant Lane, Suite 309 Clarksville, TN 37040

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

TECHNICAL DATA. * Refer the Approval Chart on page 120c and Design Criteria on page 120d for culus and FM approval requirements that must be followed.

Requirements for the protection of High-Piled Combustible Storage (HPCS) Effective Date: January 2011

Fire Protection Coffee Break Training August 2016

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Obstructions and ESFR Sprinklers Phase 2 FINAL REPORT

Model ESFR K-factor Pendent Sprinkler Early Suppression, Fast Response General Description. Sprinkler Identification Number (SIN)

Koffel Associates, Inc.

Center for Life Safety Education

ANTIFREEZE AND AUTOMATIC FIRE SPRINKLERS UPDATE. Presented by: Jerry Schultz The FPI Consortium, Inc. July 28, 2017

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST HIGH PILED STORAGE

First Revision No. 632-NFPA [ Global Input ] Supplemental Information. Submitter Information Verification. Committee Statement

American Society of Safety Engineers Professional Development Conference June 9-12, Fire Protection. Stephen J.

ESFR PENDENT SPRINKLER VK500 (K14.0) TECHNICAL DATA

TECHNICAL DATA NOTICE

SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

MODEL V-BB SPECIFIC APPLICATION TECHNICAL DATA

Fire Sprinkler System Design and Installation Requirements

APPENDIX H (DESIGN SUBMISSION CRITERIA)

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Early Suppression Fast Response Sprinklers and Obstructions

Antifreeze Solutions and Automatic Fire Sprinkler Systems. March 12, 2013

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

ADDENDUM #1 ITB# Fire Protection Maintenance Services Responses to Clarification Questions 10/06/2015

Second Revision No. 20-NFPA [ Section No. 1.4 ] Supplemental Information. Submitter Information Verification. Committee Statement

The Effect of Large Orifice Sprinklers on High-Challenge Fires

Today's Topics & Sustainability Themes

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

H gh-p led Combust ble Storage. Application Guide 2009 Edition

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Model JL-14 (SIN RA1812) K14.0 (200 metric) Early Suppression Fast Response Sprinkler

Quick Guide for Fire Sprinkler Inspection Requirements Key Deficiencies with NFPA References NFPA & NFPA 13/

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

Standpipe Systems for Fire Protection

S000 SITE REVIEW APPR NO. FIRE CODE COMPLIANCE ITEM

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Sprinkler Solutions for Storage Applications

AUTOMATIC FIRE SPRINKLER SYSTEMS

High-Piled Combustible Storage

MONTECITO FIRE PROTECTION DISTRICT

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- PLUMBING

1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M

9/10/12. NFPA Consumer Alert Antifreeze sprinkler systems. Dear Fire Sprinkler System Owner,

Redlands Fire Department Fire Protection Standard

Model ESFR-17 Early Suppression, Fast Response Upright Sprinklers 16.8 K-factor General Description

standard response elo upright and pendent sprinklers (storage-density/area)

High challenge warehouse case study Summary

Warehouse Protection of Exposed Expanded Group-A Plastics with Electronic Sprinkler Technology

Exaggerated for Clarity. Residential Pendent, Recessed Pendent. System No. Submitted By Spec Sect Para Location Date Approved Date

Fire Sprinkler Submittal Requirements and Acceptance Testing

REVISION RECORD FOR THE STATE OF CALIFORNIA EMERGENCY SUPPLEMENT

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

MSC Guidelines for Watermist Fire Suppression Systems Procedure Number: E1-03 Revision Date: 02/16/2017

CONSTRUCTION REQUIREMENTS

FIRE PROTECTION DESIGN REQUIREMENTS FOR TENANTS (Revised 1/15/2019)

culus Listed: Category VNIV Refer to the Approval Chart on page 3. VK697 Attic Upright Sprinkler Specifications:

Facilities, 2012 edition.

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

MAINTENANCE AND TESTING OF FIRE SPRINKLER SYSTEMS

IMO. 4 June 1999 GUIDELINES FOR THE APPROVAL OF ALTERNATIVE FIXED WATER-BASED FIRE-FIGHTING SYSTEMS FOR SPECIAL CATEGORY SPACES

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

RESIDENTIAL FIRE SPRINKLER SYSTEMS POLICY

DISCONTINUED PRODUCT

MSC Guidelines for Automatic Sprinkler Systems

NFPA 45 NFPA 211 NFPA 1600

40.49 V27, K5.6 FIRE PROTECTION PRODUCTS AUTOMATIC SPRINKLERS. Residential Horizontal Sidewall, Recessed Horizontal Sidewall V2744 QUICK RESPONSE

AS 2419 OVERVIEW OF PROPOSED CHANGES. Gary Nenadovich Director G N Consulting

FIRE SPRINKLER SHOP DRAWING SUBMITTAL REQUIREMENTS

Transcription:

NFPA 13 2016 Edition NFPA 13 (2016 Edition) Hot Topics and NFPA 13 FAQ s Committees created the First Draft at meetings between July 2013 and December 2013 Balloting ended in early 2014 First Draft decisions are available for viewing on thenfpa website Comments are due (on line) May 16, 2014 Committees will meet in June to take action on comments and write Second Draft Balloting through fall of 2014 Presented to NFPA membership in June 2015 2 NFPA 13 2016 Edition Documents you might want to review from NFPA website First Draft Report: Actual text of what the standard will look like if all of the changes make it through the process and nothing else changes Public Input with Responses: All of the suggestions made by the public and the committee s actions Committee Input: Ideas that the committee is considering, but has not yet decided to change First Revisions: Changes to each section in legislative text with a reason for each change Highlights of 2016 Changes Storage commodity classifications Specifically permit stainless steel in accordance with Schedule 10S or Schedule 40S Et Extensions fittings Air venting Low hanging obstructions Many small obstructions to ESFR Sprinklers in dwelling unit bathrooms 3 4 Highlights of 2016 Changes Pipe Stands, new section 9.2.6 6 inch rod rule Clean up of ESFR and solid shelves Exposed Expanded Group A Plastics on Racks Storage Commodity Classification Rewrite of the examples based on additional testing since 1990 s Change to Class IV definition Cloud Ceilings (not a change yet) 5 6 1

Class IV by Percentage of Plastic Extension Fittings 3.5.6 Extension Fitting. A male by female adapter intended to be used with a sprinkler to adjust the final fit where the sprinkler is installed in a finished ceiling or wall. 7 8 Extension Fittings 6.4.8 Extension Fitting. 6.4.8.1 The outlet diameter of the extension fitting shall be equal to the inlet diameter of the sprinkler. 6482A 6.4.8.2 A single extension fitting up to a maximum of 2 in. (50 mm) in length shall be permitted to be installed with a sprinkler. 6.4.8.2.1 The extension fitting shall be included in the hydraulic calculations. Air Venting 7.1.5 Air Venting. A single, air vent with a connection shall be provided on each wet pipe system utilizing black or galvanized steel pipe as a means for venting. 9 10 Air Venting 8.16.6* Air Venting. The vent shall be located near the highest point in the system to remove the majority of the air by one of the following methods: (1) Manual valve, minimum 1 2 in. size (2) Automatic air vent (3) Other approved means Low Hanging Obstructions 8.5.5.3.1.3 Sprinklers shall not be required under noncombustible obstructions over 4 ft (1.2 m) wide where the bottom of the obstruction is 24 in. (620 mm) or less above the floor or deck. 11 12 2

Many Small Obstructions to ESFR 8.12.5.3.3 For pipes, conduits, or groups of pipes and conduit to be considered individual, they must be separated from the closest adjacent pipe, conduit, cable tray, or similar obstructions by a minimum of three times the width of the adjacent pipe, conduit, cable tray, or similar obstruction. Dwelling Unit Bathrooms 2010 and previous editions (going back to 1989) allowed sprinklers to omitted from small bathrooms in all dwelling units 2013 changed to just allowing sprinklers to be omitted from small bathrooms in hotels and motels 2016 is proposed to go back to older text 13 14 Revolving Doors 8.15.24.1 Sprinkler protection shall not be required within revolving door enclosures. Indoor Swimming Pools 8.15.24.2.1 The area directly above indoor swimming pools shall not require sprinkler protection unless the requirements of 8.15.24.2.2 apply. 8.15.24.2.2 The area above indoor swimming pools equipped with moveable hard covers that allow the area to be used for athletic activities other than swimming and other water sports shall require sprinkler protection. 8.15.24.2.3 Sprinklers shall be installed in all areas adjacent to indoor swimming pools. 15 16 Main Drain Connections 8.16.2.4.2 will be modified to allow Main Drain connections to be larger than 2 inches Change made to facilitate backflow test Could cause problems for sprinklers and fittings if systems are drained too quickly 6 Inch Rod Rule Permitted to omit lateral seismic braces where pipe is hung by short rods Short is defined as 6 inches or less measured between the top of the pipe and the point of attachment to the building structure 17 18 3

6 Inch Rod Rule Exposed Expanded Group A on Racks New Section 17.3.3.5* Single, double, and multiple row racks Maximum storage height of 35 ft Maximum ceiling height of 40 ft Sprinklersshall shall bek 25 ESFR (intermediatetemp) temp) Design area of 15 sprinklers (5 on 3 branch lines) Minimum operating pressure of 60 psi Hose stream allowance of 250 gpm Water supply duration of 60 minutes Minimum aisle width of 8 ft 19 20 Exposed Expanded Group A on Racks New Section 17.3.3.5 Solid vertical barrier in rack from one of the following: 3 8 in. plywood or par cleboard 22 gauge sheet metal Equivalent Barrier extends from face of rack to face of rack Barrier spaced at a maximum 16.5 ft interval Barrier extends from a maximum of 4 in. above the floor to the maximum storage height. Plan area of storage between vertical barriers and aisles shall not exceed 124 ft 2 Barrier shall extend across the longitudinal flue. Commodity shall be permitted to extend a nominal 4 in. beyond the vertical barrier at the aisle Exposed Expanded Group A Plastics Max 40 ft ceiling 16.5 ft max Max 35 ft storage 21 22 Cloud Ceilings Non continuous drop ceilings in a room creating a space above the drop ceiling and a space below the drop ceiling Usually both spaces need sprinklers One Common Example of a Cloud Ceiling 23 24 4

One Common Example of a Cloud Ceiling One Common Example of a Cloud Ceiling 2013 NFPA 13 would require sprinklers above and below unless AHJ considered opening small such as used for a return air plenum 2016 NFPA 13 might allow omission of sprinklers above the opening if it is less than 1 inch for every foot of height (H) H 25 26 NFPA 13 FAQ s Antifreeze Shadow areas Obstructions in light and ordinary hazard that are not structural Protecting exposed plastics stored on racks NFSA Services Expert of the Day (EOD) Member of the Engineering Department staff on call every business day Members call or e mail questions Average response time, ½ business day Over 2600 calls annually E TechNotes Published two or three times per month One edition each month summarizes best/most interesting EOD responses of previous month 27 Antifreeze New Systems NFPA 13 and NFPA 13R New antifreeze systems are required to use listed solutions under section 7.6.2.1 Propylene glycol and glycerine are NOT listed THERE ARE NO LISTED SOLUTIONS!!! Antifreeze New Systems NFPA 13D 9.2.2.2 New antifreeze systems are permitted to be glycerine or propylene glycol Antifreeze is limited to the portion of the home subjected to freezing conditions AHJ has to be convinced that no other option is available Solutions are limited to 48% glycerine 38% propylene glycol 29 30 5

Antifreeze Existing Systems (NFPA 13/13R) Maintenance of existing systems is in accordance with NFPA 25 (see section 5.3.4.2.1) Solution can be replaced with propylene glycol or glycerine The system was installed prior to September 30, 2012 The solution is limited in concentration to 50% glycerine or 40% propylene glycol Systems with solutions in excess of 38% gy glycerine or 30% propylene glycol have to be justified by an approved risk assessment approved by the AHJ. Systems with glycerine and propylene glycol can only continue in place until September 30, 2022 After 2022, replace with a listed antifreeze solution or wet pipe system with pipes in a heated space, a dry pipe system, a preaction system or use heat tracing Antifreeze Existing Systems (NFPA 13D) Do not need to meet NFPA 25 See 9.2.2.1.1 of NFPA 13D Glycerine systems can be replaced with up to 50% solutions Propylene glycol to be replaced with up to 40% solutions. 31 32 Shadow Areas The apparent dry space within the coverage area of a sprinkler behind an obstruction where water might not directly spray from a sprinkler Does NFPA 13 allow shadow areas? Shadow Areas Yes, they are allowed by NFPA 13 for spray sprinklers and residential sprinklers (8.6, 8.7, 8.8, 8.9, 8.10) Combine sections 8.5.3.2 and 8.6.5.2.1.3 (or 8.7.5.2.1.3 etc.) Distance to a Wall 8.5.3.2.1 The distance from sprinklers to walls shall not exceed one half of the maximum allowable distance between sprinklers 8.5.3.2.2 The distance from the wall to the sprinkler shall be measured perpendicular to the wall. Three Times Rule 8.6.5.2.1.3 (paraphrased) Obstructions are permitted within the spray area of a sprinkler as long as the sprinkler is at least 3 times the maximum dimension of the obstruction away from the obstruction bt ti 6

Light Hazard Example 1 Light Hazard Example 2 Section 8.5.3.2 7.5 ft 15 ft 7.5 ft 11 ft 7.5 ft 3.5 ft Light Hazard Example 3 Section 8.6.5.2.1.3 (3 Times Rule) Light Hazard Example 4 Bring Part of the Wall Closer 15 ft 7.5 ft Obstructions that are not structural in Light and Ordinary Hazard Obstructions that are not structural in Light and Ordinary Hazard Is a light fixture that is 2 ft wide permitted to be installed 13 inches directly below a sprinkler? Is a light fixture that is 2 ft wide permitted to be installed 13 inches directly below a sprinkler? Yes, this is permitted. es, t s s pe tted As long as water can get to two sides of the obstruction As long as object is not structural As long as sprinkler is upright or pendent standard spray sprinkler See section 8.6.5.2.1.4 7

Exposed Plastics Stored on Racks Question: Can I use the rack protection rules that apply to cartoned storage for exposed plastics protection? Answer: No Evolution of rulesfrom NFPA 231C to NFPA 13 1995 and previous NFPA 231C 1998 NFPA 231C Copied into 1999 NFPA 13 Stayed the same up through 2010 NFPA 13 2013 NFPA 13 Decision Tree in 1995 (and older) NFPA 231C Cartoned Expanded or nonexpanded Stable Figure 8 2 (parts a j) 8 3.1 and 8 3.2 Group A Plastics Group B Class IV Exposed (Outside the scope of NFPA 231C) Free Flowing Class IV Group C Class III 43 44 Decision Tree in 1998 NFPA 231C Decision Tree in 2013 NFPA 13 Group A Plastics Group B Class IV Group C Class III Cartoned, expanded or unexpanded, and exposed, unexpanded Exposed, expanded (Outside the scope of Chapter 8) Stable Figures 8 2(a) through (g) Section 8 3, and 8 3.1 Free Flowing Class IV 45 8