water leak detection

Similar documents
Water Leak Detection Find Leaks Before They Find You

fuel leak detection find leaks before they find you

Leak Detection and Location Systems

FIND LEAKS BEFORE THEY FIND YOU. Leak Detection and Location Systems

TraceTek FIND LEAKS BEFORE THEY FIND YOU

Fuel Leak Detection Find Leaks Before They Find You

Industrial Strength Leak Detection

PRODUCT SELECTION GUIDE FOR WATER SENSING SYSTEMS

Sensor Interface Module Installation/Operation Instructions

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Modular Sensing Cable Installation Instructions

TT3000 and TT5000 Series

TT3000 and TT5000 Series

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Above Ground Greasy Waste Disposal Lines

CSI Master Format 2004 Guide Specification for: Flow Maintenance of Aboveground Fuel Oil Lines

Skin-Effect Heat-Tracing System (STS)

sulfur transport pipelines Safe, Reliable and Cost-Effective Heat Management System

CSI Master Format 2004 Guide Specification for: Snow Melting (Mineral Insulated)

I wish I could protect my business with the most suitable Water Mist solution to fit my needs.

COMMERCIAL HEAT TRACING PRODUCTS AND SERVICES

CSI Master Format 2004 Guide Specification for: Freezer Frost Heave Prevention (Mineral Insulated)

CSI Master Format 2012 Guide Specification for: Hot Water Temperature Maintenance (HWAT) Systems

LIQUID LEAK SENSOR INSTALLATION GUIDE

Minimize Leaks Maximize Asset Protection

For Raychem ACS-30 Controls Systems

Safer.Smarter.Tyco. Watermist fire protection Technology you can trust

Your Single. Source. Partner with Watts Water. for a Comprehensive Suite. of Innovative Water Solutions. OneWattsWater.com

CommerciaL fire-rated

COMMERCIAL & RESIDENTIAL SELF-REGULATING HEATING PRODUCTS APPLICATION AND DESIGN GUIDE EUROPE, MIDDLE EAST, AFRICA

Fire protection for buildings

Longline Heating. Contents. Introduction

910 Series Single-point heat-tracing control system

FTC-HST WARNING: CAUTION:

Liebert. Liqui-tect Leak Detection and Reporting Comprehensive Detection of Water Based Leaks in Critical Spaces

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

frost heave prevention

Your Single Source Partner with Watts for a Comprehensive Suite of Innovative Water Solutions

CO 2 Laser. High Reliability and Performance

INDUSTRIAL HEAT TRACING SOLUTIONS PRODUCTS & SERVICES

C SINGLE-POINT HEAT-TRACING CONTROL SYSTEM. product overview

TT3000 and TT5000 Series

HI-FOG for buildings. Technical introduction. Protecting people, property and business continuity. Jussi Tiainen

THE INTELLIGENCE BEHIND THE MOST INNOVATIVE FIRE DETECTION SYSTEMS

AmpLight Lighting Management System

THERMAL MANAGEMENT SOLUTIONS

Flexible Air-sampling Smoke Detection

Supervisor Standard Edition

HTC-915-CONT. Heat-Trace Control system

ADVANCED INDUSTRIAL SOLUTIONS HEAT-TRACING PRODUCTS & SERVICES

THERMAL MANAGEMENT SOLUTIONS

Denco has been producing and installing. equipment specifically designed for the precise. control of air temperature, humidity and quality

TraceTek Sensing Cable for Aboveground Leak Detection Installation Instructions

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

FreezGard. Self-regulating crankcase heater. Product Overview

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

Dual-point heat-tracing control system

- Essay Control Functions and Benefits

NGC-UIT2-ORD-R Remote User Interface Terminal for Raychem NGC Systems Installation Instructions

JBS-100-ECP-A COMBINATION POWER CONNECTION BOX AND DIGITAL ELECTRONIC CONTROLLER INSTALLATION INSTRUCTIONS

Intelligent Security and Fire Solutions. Southern Africa

Tyco Security Products Acquires Innometriks Deal strengthens TSP s Solutions in the Government Market

Dew-Point Transmitters and Instruments

JBS-100-EC Electronic controller replacement kit for JBS-100-ECP-A and JBS-100-ECW-A Installation Instructions

1SC-SSC Splice Connection Kit Installation Instructions

NGC-40 Advanced Heat-Tracing Control System

DESCRIPTION. 42 mm. 125 mm

One call protects it all.

ACS-30 MULTIPOINT COMMERCIAL HEAT-TRACING SYSTEM PRODUCT OVERVIEW. ACS-30 System

Hydronic & HVAC Control Systems

SECTION INDUCTIVE CONDUCTIVITY ANALYZERS

Harrier + Smart Controller & Chemical Management System

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

Synergy3 Owner s Manual. Owner s Manual. Geothermal Heating Cooling Hot Water

NH Series. Electric Steam Humidifiers. Designed for installation flexibility while maintaining precise humidification control

TraceTek TT1000 Modular Sensing Cable

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Redefining Customer Value

SAFETY & COMFORT FOR THE HOME RESIDENTIAL MARKET U.S. PLUMBING CANADA PLUMBING AND ELECTRICAL

Performance Based Fire Protection With Water Mist

FiberSystem. Fiber Optic Linear Heat Detection for Special Hazard Applications

HWT-P HWAT POWER CONNECTION KIT WITH END SEAL INSTALLATION INSTRUCTIONS

vanwaltconnect VAN WALT Monitoring your needs

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Life Safety Network. Intelligent solutions for advanced requirements

Better Design, Better Control, Better Systems.

Application Alley. SME Fluid Level, Pressure, and Flow Sensors. Helping Customers Win PARTNER SOLVE DELIVER

COMMERCIAL & RESIDENTIAL MARKETS U.S. ELECTRICAL

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

NGC-UIT2 MODBUS PROTOCOL INTERFACE MAPPING FOR NGC-30 SYSTEMS. Firmware versions up to V2.0.X

INDUSTRIAL HEAT TRACING SOLUTIONS. Products & Services

NH-EL. The evolution of the industry s most trusted electrode steam humidifier NH SERIES. humidity.com

SECTION Fluorescent Dissolved Oxygen Measuring System

TOUCH 1500 User Interface Terminal for Raychem NGC Systems Installation Instructions

The product segments Heating, ventilation, air conditioning. Control Products & Systems OEM.

NGC-UIT-ORD User interface terminal for Raychem NGC systems Installation Instructions

Flexible & Innovative. Cooling Solutions

GasGard 100 Control System

TT7000-HUV TraceTek Sensing Cable for Strong Mineral Acids

Transcription:

water leak detection find leaks before they find you THERMAL MANAGEMENT SOLUTIONS WWW.THERMAL.PENTAIR.COM

BUILDING & INFRASTRUCTure SOLUTIONS We provide quality solutions for winter safety, comfort and performance to building and infrastructure design, construction, operation and maintenance professionals. From pipe freeze protection to maintaining fluid temperatures and melting snow, detecting leaks or heating floors, you can rely on Pentair Thermal Managements solutions & services for greater safety, comfort and performance. THE HEART OF OUR SOLUTIONS Our TraceTek water leak detection system with sensor cables, probes and monitoring systems, lets you detect and pinpoint the source of a leak, allowing you to take corrective action before the leak can cause damage to property, data or customer goodwill. The TracekTek leak detection system is a versatile modular system with many interchangeable components that can be configured as needed for each application. The broad range of TraceTek alarm modules and modular components allows you to tailor the monitoring approach and layout to the application. Rely on Pentair Thermal Managements' leak detection solutions for greater performance for your building.

Heat Tracing Snow Melting and De-Icing Floor Heating Fire and Leak Detection Temperature Turnkey Performance Measurement Solutions Wiring water leak detection With many thousands of installed systems worldwide from London's iconic new Swiss Re building to Shanghai's World Financial Centre TraceTek sensing cables and multifunction, multi protocol digital alarm systems are the dominant solution to water leaks in buildings. Our extensive global distributor network provides local contact and installation for these systems into: Computer Rooms, Server Equipment and Communications Facilities Intelligent Buildings and Commercial Buildings Libraries and Archive Storage Facilities Museums, Heritage Sites and Aquariums This brochure highlights a range of typical risks from water leaks and how those risks can be minimized. In addition to water leak detection, we provide systems for petrochemical leak detection. Talk to us or one of our local partners to see how we can help you find leaks before they find you! WATER LEAK Floorheating DETECTION 1

risk areas applications potential consequences Heating/cooling water supply and return piping Condensate drains Fire sprinkler systems Toilets, drains and related plumbing Basements Backflow preventors Roof and window leaks Coffee and vending machines Overhead pipe runs and trays Raised floor computer facility ISP/co-location facilities Fiber optic switch sites Control rooms Trading rooms Archival storage Executive offices Communications and server equipment rooms Museums and historic buildings Libraries and aquariums Raised floor office areas Utility riser columns Elevator pits Business disruption Service interruption and network outages Loss of telephone service Liability for damage to tenant s equipment Damage to furnishings, paper files and records Cleanup costs 2 THERMAL PENTAIR MANAGEMENT SOLUTIONS

TraceTek Water Leak Detection Solutions At thousands of varied sites worldwide our products & strong distributor network have been helping commercial building managers detect water leaks and take corrective action before critical services are disrupted or priceless items are damaged. The key is quick detection and accurate location at the source of the leak. TraceTek sensor cable and monitoring systems offer: Water Leak Risks in Commercial Buildings Long term reliable systems with high performance polymers for maximum durability of the sensor cables. Cables and probes that directly detect and accurately pinpoint the source of the leak without the risk of digital communications and power running through the sensor cable out on the data center floor. A digital communications & power backbone that gives the ability to independently track many leaks at once, with local, networked or remote alarms and diagnostics. Multiple digital communications protocols and integration to building management systems, email / SMS or web page. Configuration options that automatically shut off pumps or valves where appropriate. Server and communications facility Modular assembly means systems can be configured for current needs and allow for future expansion. These are easy to segment to your needs rather than conforming to a fixed length factory standard and can handle up to 250 cables independently. All these features mean you have great design flexibility needed for modern high rise buildings. Raised floor computer facility Plumbing systems and suspended pipes WATER LEAK DETECTION 3

Solutions for Data Centres and Server Rooms The Threat Server facilities are the nerve centres for most modern businesses. Thousands of optical and electrical connections are concentrated in a densely packed space. Racked equipment generates a large amount of heat and in order to prevent equipment failures, the heat must be extracted. Heat extraction is the role of the HVAC equipment and chilled water pumped into and out of the facility is the primary heat extraction medium. However water and electronics don t mix. Water accumulating on the floor or water dripping from overhead piping can and does interrupt server operations. Early detection of any water leakage can get maintenance on scene in time to deal with the threat. Raised floor facilities are even more vulnerable because leakage is concealed. A water leak in a visible area might be noticed by employees but if the leak occurs beneath raised floors, the first alarm may occur when a critical system shuts down or water begins to rise through the structural floor to lower levels in the building. The Solution TraceTek developed water sensing cable with the ability to detect and precisely locate any water leakage. TT1000 sensor cable is designed to work on flat surfaces and is installed directly on the concrete slab beneath all data and power cabling. Any water leaking from HVAC units, chilled water fittings or back-up drains is detected immediately with location accuracy sufficient to pick the right floor tile. For racked equipment, TraceTek has developed TT1100-OHP that can be fitted to the underside of overhead pipe or used in drip trays. The same degree of detection sensitivity and leak location is delivered in a form better suited to modern server room. 4 PENTAIR THERMAL MANAGEMENT SOLUTIONS

Prevent Water Damage to Books, Artifacts and Collections Are you protected? Water causes a huge amount of damage and loss every year. TraceTek cannot prevent a catastrophic hurricane or tsunami, but the TraceTek system will alert you to preventable situations the can become catastrophic if prompt action is not taken. The problem Water damage occurs most frequently when leaks are undetected over extended periods. Many news stories begin with: When workers arrived on Monday morning. Not every leak occurs on Friday night, but a leak that does occur can cause tremendous damage before detection. Libraries, museums, basement storage vaults, archived records, and similar collections are extremely vulnerable. Water damage to carpets, hardwood floors, walls and ceilings in addition to damage to furniture and fixtures makes restoration expensive. If water damage impacts a work area, alternate space must be found, staff must be temporarily relocated, communications must be re-routed and many man hours will be lost. The Solution TT1000 and TT1100 -OHP sensor cables can be positioned in and around possible sources of water or deployed around areas that need protection. Building service columns, just inside the foundation for underground storage vaults, around the interior service core of the building at each floor, around the window perimeter beneath fan-coil units are all typical examples of where sensor cable can be effectively deployed. When mechanical equipment is supplied with dedicated drip pans, a TT-FLAT-PROBE is an excellent way to monitor for any water accumulation. All TraceTek sensor cables and probes are equally effective for potable water, condensate or water glycol mixtures. WATER LEAK Floorheating DETECTION 5

Solutions for diesel generators TraceTek 5000 sensor cable and TT-FFS Fast Fuel Sensor Probes have been certified to meet FM 7745 Approval Standard For Diesel Leak Detectors Not all pipes contain water Increasingly, commercial facilities must have back-up power sources and the most common way to provide that power is with diesel powered generators. However, pumping and storing diesel fuel inside of a building introduces a risk of fire that exceeds the rapid acceleration that the water sprinkler system can control. FM Global has recently released FM 7745 Approval Standard for Diesel Leak Detectors. TraceTek s Fast Fuel Sensor Probe and TT5000 Fuel Sensor Cable have been tested by FM approvals and are certified to meet the requirements of the new standard. The problem Hospitals, server facilities, large office buildings and many other commercial and institutional facilities require diesel powered back-up generators. In many older buildings, generators have been squeezed into spaces that were not originally designed for that purpose. Each generator requires a day tank, fuel pumps, valves, hose connections and similar fittings. Frequently there will be a supply and return piping connection to a larger underground diesel storage tank outside of the building footprint. An undetected diesel fuel leak presents a major fire risk and if ignited could lead to a rapidly growing fire beyond the extinguishing capacity of sprinkler systems. The Solution TraceTek Fast Fuel Sensor (TT-FFS) and TT5000 Fuel Sensor Cable can be deployed around the generator pad, under day tanks, in double wall pipe or trenches connecting supply and return piping, and in similar applications. The TT-FFS probe is capable of reacting to the presence of diesel within a few seconds. It will detect a puddle of diesel spreading across a flat surface or a layer of diesel floating on water. TT-FFS can be tested as desired, re-used and reset after a leak encounter. The TT5000 sensor cable can monitor tens of hundreds of meters of piping and provide the same precise leak location information that is a feature of all TraceTek cables. 6 PENTAIR THERMAL MANAGEMENT SOLUTIONS

products and technology Digital or Analog? Don t be confused by claims to the contrary: All sensing is done at the analog level by measuring voltage, current and resistance. All modern systems convert the analog values to digital values then use digital telemetry to bring the measurement values to the alarm panel. TraceTek s combination of analog measurement and digital technology, permits designers to tailor their leak detection system to larger floor areas, multiple levels and smaller discontinuous areas with ease. As all SIMs speak Modbus, Johnson Controls N2 Open protocol and allow for easy conversion to BACnet, TraceTek leak detection can be a plug-and-play addition to many building management systems. Digital Out 1 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 V, ma, Ω Analogue In Conductive polymers are used to extend the life of TraceTek cables. Some of the oldest TraceTek water detection cables have been in continuous service for more than 25 years. TT1000 cable core is built with tough engineering plastics suitable to take the load and stress from being on the bottom layer of an under floor cable stack. TT1100-OHP is a design tailored for overhead pipe, drip trays and dirty areas. The unique polyester over braid layer provides a wicking action that assures the first drops of water to hit the sensor cable are absorbed and wicked along the cable until an alarm signal is generated and the leak located. The rope layer also provides additional insulation where sharp metal edges could be a problem and works well to protect the sensor electrodes in dirty or dusty areas. TT1000 TT-MINI PROBE TT1100 OHP TT-TS12 TraceTek provides an array of choices for monitoring systems. Sensor Interface Modules (SIM) provide the excitation voltage necessary to operate cable or probes. The SIM monitors analogue current and voltage levels to determine when and where a leak has occurred. The measurements are digitized and transmitted back to the control and alarm panel for user display or interface to higher level systems. TTSIM-1A TT-FFS TT-TS12 touchscreen panel provides a graphic user interface to manage and display information from a network of up to 250 external TraceTek leak detection circuits. TT5000 TT-FLAT PROBE WATER LEAK Floorheating DETECTION 7

approval and certifications TraceTek leak detection systems are approved and certified for use in nonhazardous and hazardous locations by one or more of the following agencies, including FM Approvals, UL, TÜV, VDE, Baseefa and LCIE. For a copy of our animation which shows multiple applications of TraceTek water leak detection technology, email us at: thermal.info@pentair.com For Water Leak Detection, Look to the Leader. Visit our website at www.tracetek.com 8 PENTAIR THERMAL MANAGEMENT SOLUTIONS

TraceTek Water Leak Detection Find Leaks Before They Find You WATER LEAK Floorheating DETECTION 9

WWW.THERMAL.PENTAIR.COM NORTH AMERICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7215 thermal.info@pentair.com Europe, Middle East, Africa Tel: +32.16.213.511 Fax: +32.16.213.603 thermal.info@pentair.com Asia Pacific Tel: +86.21.2412.1688 Fax: +86.21.5426.2917 cn.thermal.info@pentair.com Latin America Tel: +55.11.2588.1400 Fax: +55.11.2588.1410 thermal.info@pentair.com Pentair and TraceTek are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2011-2013 Pentair. THERMAL MANAGEMENT SOLUTIONS EN-TraceTekWaterLeakDetection-SB-H58485 01/13