SEALED BURNER RANGETOPS

Similar documents
GAS COOKTOPS INSTALLATION INSTRUCTIONS. Model numbers ICBCG15 ICBCG304 ICBCG365

Multi-Function Cooktop

INSTALLATION GUIDE Dual Fuel Ranges

D UAL F UEL R ANGES INSTALLATION INSTRUCTIONS

I NDUCTION C OOKTOP INSTALLATION INSTRUCTIONS

RANGETOPS. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

INSTALLATION GUIDE Fryer Module

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Steamer Module

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

Cooktop Chimney Ventilation Hoods

Downdraft Ventilation

INSTALLATION GUIDE Induction Cooktops

Installation Instructions Dual Fuel Ranges

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

CAUTION signals a situation where minor injury or product damage may occur if you do not follow instructions.

INSTALLATION GUIDE NZ AU D

INSTALLATION INSTRUCTIONS

If you want to offer a more professional look to your

There's a good reason why professional chefs choose

MODULES. Features and specifications are subject to change at any time without notice. Throughout this guide, dimensions may vary by ± 3 mm.

Wok Cookers Instruction Manual

36" GLASS SEALED-BURNER GAS COOKTOP

INSTALLATION GUIDE Warming Drawers

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

Viking Installation Guide

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE NZ AU E

GAS COOKTOP INSTALLATION INSTRUCTIONS

Service Manual Electric Cooktop

If it looks as if it could be in a restaurant kitchen, well,

Installation Instructions

Gas Cooktop Installation, User and Service Instructions GMS 955.1

Installation Instructions

Warming Drawer Installation Guide

GE Monogram. Installation. Instructions. Professional Gas Cooktops 48" Natural Gas Models ZGU48N4GWSS ZGU48N6RWSS ZGU48N6DWSS

If it looks as if it could be in a restaurant kitchen, well,

L Series Built-In Ovens

Installation Instructions

Installation Instructions

DESIGN CLASS FUNCTION

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

Installation. Built-In Electric Cooktop. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation Instructions Preference. Cooktop. Models: SGM304, SGM365, SGM466. Part No Rev. K

Installation Instructions Remote Blowers

DESIGN CLASS FUNCTION

INSTALLATION & OPERATING INSTRUCTIONS GAS HOBS MODELS

Undercounter Refrigeration

New features make cooking a greater pleasure than

Integrated Ventilation System

Installation. 3 Series Built-In Electric Cooktop RVEC330 / CRVEC330 RVEC336 / CRVEC336 RVEC345 / CRVEC345

With Wolf's dual fuel ranges you have state-of-the-art

With Wolf's dual fuel ranges you have state-of-the-art

GAS COOKTOPS USE & CARE INFORMATION. Model numbers ICBCG15 ICBCG304 ICBCG365

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

With Wolf's dual fuel ranges you have state-of-the-art

Installation Instructions

Installation Instructions. Distinctive Electric Cooktop. Françis : voir page 11 Español: consulte la página Rev. A. Models DECT304, DECT365

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

Viking Installation Guide

GAS COOKTOP INSTALLATION INSTRUCTIONS

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

DISHWASHER INSTALLATION GUIDE SPECIFICATIONS, INSTALLATION, AND MORE

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

BESTLINK INTERNATIONAL. User instructions Maintenance instructions Installation & service instructions

Installation Instructions Millennia Cooktops

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Installation Instructions Distinctive. Series Cooktop. Models DCT305, DCT365. Part No Rev. L

Viking Installation Guide

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Downdraft Raised Vent

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

Installation Instructions

Electric Built-in Ceramic Cooktops

SEALED BURNER RANGETOPS

Owner s Guide Installation & Operation

Specialist Deluxe Series II Built-In 4 & 6 Burner BBQ BQ8342B & BQ8362B

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

MODELS LFP4218/LFP6018 TOP VENT GAS FIREPLACE

CLGOGUIT

GAS-ON-GLASS COOKTOP

INSTALLATION INSTRUCTIONS

Installation Instructions Induction Cooktop

Installation Instructions

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS

Operating instructions for the DA 8-2 Extractor

Installation Instructions. Discovery Gas Cooktop. Models DYCT304G, DYCT365G. Part No Rev. A

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

Installation Instructions Dual Fuel Ranges

Outdoor Tabletop Heater TTH20 Series

Installation Instructions

Patio Heater Model No. GM and GM

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

Installation Instructions

Automatic Dryers. Installation. Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.

Installation Instructions Epicure. Cooktop. Models: ESG366, ESG486. Part No Rev. K

Transcription:

SEALED BURNER RANGETOPS INSTALLATION INSTRUCTIONS Rangetop series ICBSRT Models ICBSRT304 ICBSRT364C ICBSRT364G ICBSRT486C ICBSRT486G ICBSRT484CG ICBSRT484F

3

CONTACT INFORMATION Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 Phone 03 9600 2218 subzero-wolf.com.au As you follow these instruc tions, you will noticewarning and CAUTION symbols. This blocked information is impor tant for the safe and efficient installation of Wolf equipment. There are two types of potential hazards that may occur during installation. signals a situation where minor injury or product damage may occur if you do not follow instructions. states a hazard that may cause serious injury or death if precautions are not followed. Another footnote we would like to identify is IMPORTANT NOTE: This highlights information that is especially relevant to a problemfree installation. WOLF is a registered trademark of Wolf Appliance, Inc.

WOLF SEALED BURNER RANGETOP INSTALLATION REQUIREMENTS WHAT TO DO IF YOU SMELL GAS: This appliance shall be installed in accordance with the regulations in force and only used in a well ventilated space. Read the instructions before installing or using this appliance. IMPORTANT NOTE: Installation and service must be performed by an authorized person. The appliance must not be modified. Do not store or use gasoline or other flaable vapors and liquids in the vicinity of this or any other appliance. The use of a gas cooking appliance results in the production of heat and moisture in the room in which it is installed. Ensure that the kitchen is well ventilated; keep natural ventilation holes open or install a mechanical ventilation device (mechanical extractor hood) Prolonged intensive use of the appliance may for additional ventilation, for example opening of a window, or more effective ventilation, for example increasing the level of mechanical ventilation where present. Do not try to light any appliance. Do not touch any electrical switch. Do not use any phone in your building. Iediately call your gas supplier from a neighbor s phone. Follow the gas supplier s instructions. If you cannot reach your gas supplier, call the fire department. STATUTORY REQUIREMENTS This appliance shall be installed in accordance with the manufacturer s installation instructions, local gas fitting regulations, municipal building codes, electrical wiring regulations, and AS/NZS 5601 the Australian Standard for gas installations. Refer also to AS/NZS 5601 for gas pipe sizing tables. Not suitable for use in marine craft, caravan or mobile home. Unless each burner is fitted with a flame safeguard. A ventilation range hood must be installed for use with the Wolf sealed burner rangetops. 4

WOLF SEALED BURNER RANGETOP INSTALLATION REQUIREMENTS BEFORE YOU START RATING PLATE INFORMATION Model Number Serial Number IMPORTANT NOTE: This installation must be completed by a qualified installer, service agency or gas supplier. IMPORTANT NOTE: Save these Installation Instructions for the local inspector s use. Please read the entire Installation Instructions prior to installation. Installer: please retain these instructions for local inspector s reference, then leave them with the homeowner. Homeowner: please read and keep these instructions for future reference and be sure to read the entire Use & Care Information prior to use. IMPORTANT NOTE: This appliance must be installed in accordance with local codes. The correct voltage, frequency and amperage must be supplied to the appliance from a dedicated, grounded circuit which is protected by a properly sized circuit breaker or time delay fuse. The proper voltage, frequency, and amperage ratings are listed on the product rating plate. Record the model and serial numbers before installing the sealed rangetop. Both numbers are listed on the rating plate, located on the underside of the sealed rangetop. Refer to the illustration below. Proper installation is your responsibility. Have a qualified technician install this sealed rangetop. You must also assure that electrical installation is adequate and in compliance with all local codes and ordinances. Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the adjustment of the appliance are compatible. Proper gas supply connection must be available; refer to Gas Supply Requirements on page 12. Electrical ground is required; see Electrical Requirements on page 15. The adjustment conditions for this appliance are stated on the label (or rating plate). The data plate can be found on the underside of the sealed rangetop. Location of rating plate under control panel Rating plate location 5

INSTALLATION INSTRUCTIONS BEFORE YOU START INSTALLATION SPECIFICATIONS Check the location where the rangetop will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans. Do not obstruct the flow of air. The area in which you are installing this appliance must have an adequate supply of fresh air to ensure proper combustion and ventilation. This appliance is not connected to a combustion products evacuation device. It shall be installed and connected in accordance with current installation regulations. Particular attention shall be given to the relevant requirements regarding ventilation. All openings in the wall where the rangetop is to be installed must be sealed. Wolf sealed burner rangetops come in 762, 914 and 1219 widths. Illustrations on pages 9 11 provide the overall dimensions and installation specifications for each width of sealed burner rangetop. Each rangetop is designed to fit between cabinets set at the distance specified by the unit. For example, a 914 rangetop will fit a 914 opening. IMPORTANT NOTE: Cabinet opening dimensions shown in the Installation Specifications illustrations must be used. These dimensions provide for required clearances. IMPORTANT NOTE: Locate the electrical supply within dimensions shown in the Installation Specifications illustrations. Refer to the Installation Specifications illustration for your model on pages 9 11 for the exact rough opening dimensions and location of the gas and electrical supply. 6

W OLF SEALED B U RNER RANGETO P MINIMUM CLEA R ANCES IMPORTANT NOTE: Caution must be used in planning the proper installation of the Wolf sealed burner rangetop to avoid fire or damage to adjacent cabinetry or kitchen equipment. Be sure to follow the minimum clearances established in the finished rough opening dimensions. Refer to the Installation Specifications illustration for your model on pages 9 11 for the exact rough opening dimensions. WA LL I N S TALLATION S Minimum clearances to combustible surfaces: Minimum 457 clearance from bottom of upper cabinet to countertop, within 152 minimum side clearance. Minimum spacing between overhead side cabinets must be greater than or equal to the nominal width of the rangetop. The maximum depth of overhead and side cabinets is 330, within 152 side clearance. 0 clearance for adjacent combustible materials below the countertop, both sides and rear. Bottom of ventilation hood must be 762 minimum to 914 maximum from countertop. Minimum clearances for sealed burner rangetops without a ventilation hood: Model ICBSRT304: 762 minimum vertical distance from countertop to combustible materials above the rangetop. All Other Sealed Burner Rangetops: Surface Burners or Griddle (G) Models: 914 minimum vertical distance from countertop to combustible materials above the rangetop. Charbroiler (C) Models: 1118 minimum vertical distance from countertop to combustible materials above the rangetop. ISLAN D P E NINSULA I N S TALLATION S Minimum clearances to combustible surfaces: Island Installations: Minimum 305 clearance to rear wall that rises above the countertop. Peninsula Installations: Minimum 152 clearance to side walls and minimum 305 clearance to rear wall that rises above the countertop. Refer to the Installation Specifications illustration for your model on pages 9 11 for the exact rough opening dimensions. Failure to locate the rangetop without the proper clearances will result in a fire hazard. R I SER REQUIREM E N T S Installations against a combustible surface: Model ICBSRT304: No riser requirements. 914 Sealed Burner Rangetops: A minimum 254 riser is required for all charbroiler (C) or griddle (G) models installed against a combustible surface. 1219 Sealed Burner Rangetops: A minimum 254 riser is required for all charbroiler (C) or griddle (G) models installed against a combustible surface. VENTILATION A suuitable ventilation range hood must be installed. Important Note: It is recoended that you operate the Wolf Sealed Burner Rangetop with a Wolf Pro ventilation hood. Contact your Wolf dealer for details. Important Note: When installing a ventilation hood, refer to the specific requirements of the hood for the minimum dimension to countertop. 7

INSTALLATION INSTRUCTIONS 762 SEALED BURNER RANGETOP 724 OVERALL DEPTH COOKING SURFACE 216 OVERALL HEIGHT 191 235 699 WITH 508 RISER 445 318 WITH WITH 254 127 RISER RISER OVERALL DIMENSIONS Overall Width Overall Height (to cooking surface) Overall Depth 759 216 724 759 OVERALL WIDTH 616 Opening Width 762 Dimensions may vary to ±3. INSTALLATION SPECIFICATIONS VENTILATION HOOD 152 min TO COMBUSTIBLE MATERIALS (BOTH SIDES) 762 min COUNTERTOP TO COMBUSTIBLE MATERIALS 762 min TO 914 max TO BOTTOM OF VENTILATION HOOD 762 OPENING WIDTH 19 PLATFORM LOCATION OF GAS AND ELECTRICAL SUPPLY CUT-OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 406 TOP VIEW OF PLATFORM 102 E G 406 BACK WALL 457 min TO COUNTERTOP 914 216 COOKING SURFACE 19 PLATFORM 610 330 max 191 Note A: Side clearances. If the distance measured from the periphery of the nearest burner to any vertical surface is less than 200, the surface shall be protected in accordance with AS/NZS 5601 Note B: The rangehood fitted above the cooktop must be installed according to the installation instructions for the rangehood. A minimum distance of 750 is required for a range hood and 750 for an exhaust fan. ISLAND INSTALLATIONS: 305 MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 TO NON-COMBUSTIBLE MATERIALS 8

WOLF SEALED BURNER RANGETOP 914 SEALED BURNER RANGETOP 724 OVERALL DEPTH OVERALL DIMENSIONS Overall Width Overall Height (to cooking surface) Overall Depth 911 216 724 COOKING SURFACE 216 OVERALL HEIGHT 191 235 445 WITH 254 RISER 699 WITH 508 RISER Opening Width 914 911 OVERALL WIDTH 616 Dimensions may vary to ±3. Homeowner: please read and keep these instructions for future reference and be sure INSTALLATION SPECIFICATIONS IMPORTANT NOTE: A minimum 254 riser is required for all charbroiler (C) or griddle (G) models installed against a combustible surface. VENTILATION HOOD Note A: Side clearances. If the distance measured from the periphery of the nearest burner to any vertical surface is less than 200, the surface shall be protected in accordance with AS/NZS 5601 Note: B The rangehood fitted above the cooktop must be installed according to the installation instructions for the rangehood. A minimum distance of 750 is required for a range hood and 750 for an exhaust fan. 152 min TO COMBUSTIBLE MATERIALS (BOTH SIDES) 914 min COUNTERTOP TO COMBUSTIBLE MATERIALS 1118 min FOR CHARBROILER 762 min TO 914 max TO BOTTOM OF VENTILATION HOOD 914 FINISHED ROUGH OPENING WIDTH 19 PLATFORM LOCATION OF GAS AND ELECTRICAL SUPPLY CUT-OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 406 TOP VIEW OF PLATFORM 102 E G 406 BACK WALL 457 min TO COUNTERTOP 914 216 COOKING SURFACE 19 PLATFORM 610 330 max 191 ISLAND INSTALLATIONS: 305 MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 TO NON-COMBUSTIBLE MATERIALS 9

INSTALLATION INSTRUCTIONS 1219 SEALED BURNER RANGETOP 724 OVERALL DEPTH COOKING SURFACE 216 OVERALL HEIGHT 191 235 699 WITH 508 RISER 445 318 WITH WITH 254 127 RISER RISER OVERALL DIMENSIONS Overall Width Overall Height (to cooking surface) Overall Depth 1216 216 724 1216 OVERALL WIDTH 616 Opening Width 1219 Dimensions may vary to ±3. INSTALLATION SPECIFICATIONS VENTILATION HOOD IMPORTANT NOTE: For 1219 sealed burner rangetops, a minimum 254 riser is required for all charbroiler (C) or griddle (G) models installed against a combustible surface. 152 min TO COMBUSTIBLE MATERIALS (BOTH SIDES) 914 min COUNTERTOP TO COMBUSTIBLE MATERIALS 1118 min FOR CHARBROILER 762 min TO 914 max TO BOTTOM OF VENTILATION HOOD 1219 FINISHED ROUGH OPENING WIDTH 19 PLATFORM LOCATION OF GAS AND ELECTRICAL SUPPLY CUT-OUT WITHIN SHADED AREA THROUGH BOTTOM OF PLATFORM 406 TOP VIEW OF PLATFORM 102 E G 406 BACK WALL 457 min TO COUNTERTOP 914 216 COOKING SURFACE 19 PLATFORM 610 330 max 191 Note A: Side clearances. If the distance measured from the periphery of the nearest burner to any vertical surface is less than 200, the surface shall be protected in accordance with AS/NZS 5601 Note B: The rangehood fitted above the cooktop must be installed according to the installation instructions for the rangehood. A minimum distance of 750 is required for a range hood and 750 for an exhaust fan. ISLAND INSTALLATIONS: 305 MINIMUM CLEARANCE FROM BACK OF RANGETOP TO COMBUSTIBLE REAR WALL ABOVE COUNTERTOP 0 TO NON-COMBUSTIBLE MATERIALS 10

WOLF SEALED BURNER RANGETOP INSTALL THE RANGETOP GAS SUPPLY REQUIREMENTS IMPORTANT NOTE This installation must conform with local codes and ordinances. Prepare the finished rough opening for the rangetop according to the Installation Specifications illustration for your model on pages 9 11. The platform must be 19 thick and include a cut-out at the right rear for gas supply and electrical connections. IMPORTANT NOTE: The platform must be level to ensure that the cooking surface is level. Remove and discard all packing materials, including cardboard and tape on the outside of the rangetop. Remove the burner grates and styrofoam off the top cooking surface. Be sure to remove the burner caps packaged in styrofoam below the burner grates. If your installation requires a riser, it must be attached to the rangetop before installation. Refer to the installation instructions packaged with the riser. Position the rangetop on the platform. Gas supply and electrical connections should be made before the rangetop is placed in its final position. EXPLOSION HAZARD Securely tighten all external gas connections. Failure to do so can result in explosion, fire or death. IMPORTANT NOTE: The sealed rangetop must be connected to a regulated gas supply. IMPORTANT NOTE: This installation must conform with local codes and ordinances. The rating plate, located on the underside of the burner box, has information on the type of gas that should be used. If this information does not agree with the type of gas available, check with the local gas supplier. An ISO 7-1 gas inlet thread is provided on all units. Please contact your local Wolf dealer if an ISO 228-1 or other gas inlet thread is required. Pipe joint compounds, suitable for use with LP gas should be used. LP gas suppliers usually determine the size and materials used on the system. Flexible hose must be certified to AS1869 class B or D 10 in diameter and no longer than 1200 long. The hose must not be kinked or be able to touch any hot surface. The supply connection point must be accessible when installed. If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the sealed rangetop. All strains must be removed from the supply and gas lines so the sealed rangetop will be level and in line. 11 GAS CONNECTION: Fit regulator (N.G.) or Propane fitting (LPG), the direction for gas flow is indicated on the regulator. Check correct operation of each burner individually and in combination. Burner flames should be clear blue, with no yellow tipping. If the burners show any abnormality, check that the burner heads are correctly located and refer to trouble shooting page 16. If satisfactory performance can not be obtained contact Multyflex or the local gas utility. Note: These burner have no aeration adjustment. Instruct the user in the operation of the appliance before leaving. A duplicate plate can be attached to the inside top of an adjacent cupboard.

INS TA L L AT I O N I N S T R UCT I O N S G A S R AT I N G MF049 MF049 MF049 GSCS20230 SAI GLOBAL AS4551 Made in USA Model No: ICBSRT486G Serial No: Gas type NG LPG Test point press. (kpa) 1.0 2.75 Injector sizes () RHF/CF 1.80 1.09 RHR/CR 1.80 1.09 Griddle 1.70 1.09 LHF 1.80 1.09 LHR 1.35 0.89 Total Consumption (MJ/h) 94.0 94.1 Electrical compliance: in accordance with AS/NZS3100 240 V AC, 10 amps, 50 Hz Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218 GSCS20230 SAI GLOBAL AS4551 Made in USA Model No: ICBSRT486G Serial No: Gas type NG LPG Test point press. (kpa) 1.0 2.75 Injector sizes () RHF/CF 1.80 1.09 RHR/CR 1.80 1.09 Griddle 1.70 1.09 LHF 1.80 1.09 LHR 1.35 0.89 Total Consumption (MJ/h) 94.0 94.1 Electrical compliance: in accordance with AS/NZS3100 240 V AC, 10 amps, 50 Hz Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218 GSCS20230 SAI GLOBAL AS4551 Made in USA Model No: ICBSRT486G Serial No: Gas type NG LPG Test point press. (kpa) 1.0 2.75 Injector sizes () RHF/CF 1.80 1.09 RHR/CR 1.80 1.09 Griddle 1.70 1.09 LHF 1.80 1.09 LHR 1.35 0.89 Total Consumption (MJ/h) 94.0 94.1 Electrical compliance: in accordance with AS/NZS3100 240 V AC, 10 amps, 50 Hz Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218 MF049 MF049 MF049 GSCS20230 SAI GLOBAL AS4551 Made in USA Model No: ICBSRT486G Serial No: Gas type NG LPG Test point press. (kpa) 1.0 2.75 Injector sizes () RHF/CF 1.80 1.09 RHR/CR 1.80 1.09 Griddle 1.70 1.09 LHF 1.80 1.09 LHR 1.35 0.89 Total Consumption (MJ/h) 94.0 94.1 Electrical compliance: in accordance with AS/NZS3100 240 V AC, 10 amps, 50 Hz Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218 GSCS20230 SAI GLOBAL AS4551 Made in USA Model No: ICBSRT486G Serial No: Gas type NG LPG Test point press. (kpa) 1.0 2.75 Injector sizes () RHF/CF 1.80 1.09 RHR/CR 1.80 1.09 Griddle 1.70 1.09 LHF 1.80 1.09 LHR 1.35 0.89 Total Consumption (MJ/h) 94.0 94.1 Electrical compliance: in accordance with AS/NZS3100 240 V AC, 10 amps, 50 Hz Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218 GSCS20230 SAI GLOBAL AS4551 Made in USA Model No: ICBSRT486G Serial No: Gas type NG LPG Test point press. (kpa) 1.0 2.75 Injector sizes () RHF/CF 1.80 1.09 RHR/CR 1.80 1.09 Griddle 1.70 1.09 LHF 1.80 1.09 LHR 1.35 0.89 Total Consumption (MJ/h) 94.0 94.1 Electrical compliance: in accordance with AS/NZS3100 240 V AC, 10 amps, 50 Hz Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 +61 3 9600 2218 12

WOLF SEALED BURNER RANGETOP GAS SUPPLY REQUIREMENTS GAS LEAK TESTING Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off the gas valve and adjust connections. Then check connections again. Clean all the detergent solution from the rangetop. Never test for a gas leak with a match or other flame. 13

INSTALLATION INSTRUCTIONS ELECTRICAL REQUIREMENTS RECOMMENDED GROUND METHOD ELECTRICAL SHOCK HAZARD Plug into a grounded 3-prong adapter. Do not remove ground prong. Do not use an adapter. Failure to follow these instructions can result in electric shock, fire or death. IMPORTANT NOTE: If codes permit and a separate ground wire is used, it is recoended that a qualified electrician determine that the ground path is adequate. IMPORTANT NOTE: Check with a qualified electrician if you are not sure whether the sealed rangetop is properly grounded. IMPORTANT NOTE: Do not ground to a gas pipe. A 220-240 V AC, 50/60 Hz, fused electrical supply is required. A time-delay fuse or circuit breaker is recoended. It is recoended that a separate circuit serving only this appliance be provided. Electronic ignition systems operate within wide voltage limits, but proper ground and polarity are necessary. In addition to checking that the outlet provides 220-240 V AC power and is correctly grounded, the outlet must be checked by a qualified electrician to see if it is wired with correct polarity. This appliance, when installed, must be electrically grounded in accordance with local codes. IMPORTANT NOTE: For your personal safety, this sealed rangetop must be grounded. This sealed rangetop is equipped with a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in conformance with all local codes and ordinances. If a mating outlet is not available, it is the obligation of the customer to have a properly grounded, 3-prong outlet installed by a qualified electrician. IMPORTANT NOTE: If product is connected to a GFCI protected outlet, nuisance tripping of power supply may occur, resulting in loss of product operation. WIRING DIAGRAM The wiring diagram covering the electrical circuit is located on the inside left wall of the rangetop. 14

WOLF SEALED BURNER RANGETOP SURFACE BURNERS SEALED RANGETOP REMOVAL INITIAL LIGHTING The surface burners use electronic igniters in place of standing pilots. When the sealed rangetop control knob is pushed in and turned to the position, the system creates a spark to light the burner. This sparking continues until the electronic ignition senses a flame. If the burner fails to ignite after 10 seconds, return the knob to the position and attempt to ignite by turning the knob back to the position. Be sure to place the burner heads and caps on each burner base and position the burner grates over the burner bases and heads before lighting. To check operation of the surface burners, push in and turn each control knob to the position. The flame should light within four seconds. If the burners do not light properly, turn control knob to the position. Check that the burner heads and caps are in the proper position. Check that the power supply cord is plugged in and that the circuit breaker or house fuse has not blown. Check operation again, if the burners do not light properly at this point, contact a Wolf authorized service center. IMPORTANT NOTE: Initial lighting of the surface burners may take slightly longer, as air in the system must be purged before gas can be supplied to the burner. If it is necessary to remove the sealed rangetop for cleaning or service, shut off the gas supply. Disconnect the gas and electric supply. Remove the mounting brackets on the right and left side of the burner box and remove the sealed rangetop. Reinstall in the reverse order and check the gas connection for leaks. TROUBLESHOOTING IMPORTANT NOTE: If the sealed rangetop does not operate properly, follow these troubleshooting steps: Verify that power is being supplied to the sealed rangetop. Check that gas valves are turned to the ON position. Check the gas supply and electrical connections to ensure that the installation has been completed correctly. Follow troubleshooting procedures as described in the Wolf Sealed Burner Rangetops Use & Care Information. If the sealed rangetop still does not work, contact a Wolf authorized service center. Do not attempt to repair the sealed rangetop yourself. Wolf is not responsible for service required to correct a faulty installation. 15

INSTALL ATIO N INSTR UCTION S IF YOU N EED SER VICE For service in your area, contact either your Wolf dealer or visit the Showroom Locator section of our website, wolfappliance.com to find the regional distributor by country. When calling for service, you will need the sealed rangetop model and serial numbers. Both numbers are listed on the rating plate, located on the underside of the sealed rangetop. Refer to the illustration on page 6 for location of the rating plate. CONTACT INFORMATION Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 Phone 03 9600 2218 subzero-wolf.com.au The information and images in this book are the copyright property of Wolf Appliance, Inc., an affiliate of Sub-Zero, Inc. Neither this book nor any information or images contained herein may be copied or used in whole or in part without the express written permission of Wolf Appliance, Inc.,an affiliate of Sub-Zero, Inc. Wolf Appliance, Inc. all rights reserved. 16

Wiring Diagrams ICB Sealed Burner Rangetop (ICBSRT) Series WIRING SCHEMATIC Model: ICBSRT304 - This wiring information is provided for use by qualified service personnel only. - Disconnect appliance from electrical supply before beginning service. - Be sure all grounding devices are connected when service is complete. - Failure to observe the above warnings may result in severe electrical shock. 10 VDC SOLENOID 230V 50 CYCLES N IN L1 IN GROUND S1 S2 S3 CNTRL, IGNTR, VALVE 4 PT SW1 SW2 SW3 SW4 SW5 SW6 LINE NOT USED NEUTRAL GND 3-GRN/YLW S4 GAS VALVE GAS VALVE NOT USED NOT USED 4-GRN/YLW 2-WHT 1-BLACK 7-ORANGE 6-ORANGE CAPPED CONNECTOR RIGHT REAR S3 LEFT REAR S1 RIGHT FRONT S4 LEFT FRONT S2 RIGHT FRONT SWITCH SW4 RIGHT REAR SWITCH SW3 LEFT FRONT SWITCH SW2 14-BLACK LEFT REAR SWITCH SW1 8-BLUE 16-BLACK 17-BLACK 18-BLACK 11-BLUE 9-BLUE 10-BLUE 5-WHITE 15-BLACK #820376 Revision A October, 2011 7-2

ICB Sealed Burner Rangetop (ICBSRT) Series Wiring Diagrams WIRING SCHEMATIC Model: ICBSRT484CG - This wiring information is provided for use by qualified service personnel only. - Disconnect appliance from electrical supply before beginning service. - Be sure all grounding devices are connected when service is complete. - Failure to observe the above warnings may result in severe electrical shock. 21-BLK RIGHT FRONT SWITCH SW4 11-BLUE 7-ORN 10 VDC SOLENOID 230 V 50 CYCLES N IN L1 IN GROUND 3-GRN/YEL 1-BLK 6-ORN 2-WHT RIGHT REAR S3 RIGHT FRONT S4 19-BLK 20-BLK RIGHT REAR SWITCH SW3 CAPPER CONNECTORS JUMPER 10-BLUE CHARBROILER S5 S1 S2 S3 S4 S5 4-GRN/YEL GRIDDLE DIRECT SPARK IGNITOR MODULE 18-BLK 2 VDC INDICATOR LED GRIDDLE THERMOSTAT 26-BLK/ORN SW1 SW2 SW3 SW4 SW5 SW6 CONTROL, IGNTR, VALVE 5 PT LINE NOT USED NEUTRAL GND GAS VALVE GAS VALVE NOT USED NOT USED 5-WHT 14-BLK 15-BLK LEFT REAR S1 LEFT FRONT S2 16-BLK 17-BLK LEFT FRONT SWITCH SW2 LFT REAR SWITCH SW1 8-BLUE 9-BLUE 29-BLK 10 VDC SOLENOID 27-GRN/YEL 28-BLK 25-WHT 24-ORN J4 SPARK1 23-ORN 10 9 8 7 6 5 4 3 2 1 13-BLUE CHARBRLR SWITCH SW5 12-BLUE GND DIRECT SPARK IGNITOR MODULE 7-7 #820376 Revision A October, 2011

Wiring Diagrams ICB Sealed Burner Rangetop (ICBSRT) Series WIRING SCHEMATIC Model: ICBSRT484F - This wiring information is provided for use by qualified service personnel only. - Disconnect appliance from electrical supply before beginning service. - Be sure all grounding devices are connected when service is complete. - Failure to observe the above warnings may result in severe electrical shock. 21-BLK RIGHT FRONT SWITCH SW4 11-BLUE 7-ORN 10 VDC SOLENOID 230 V 50 CYCLES N IN L1 IN GROUND 3-GRN/YEL 1-BLK 6-ORN RIGHT REAR S3 FRENCHTOP SWITCH SW5 S1 S2 S3 S4 RIGHT FRONT S4 S5 12-BLUE 19-BLK 20-BLK RIGHT REAR SWITCH SW3 CAPPER CONNECTORS 10-BLUE 13-BLUE 2-WHT JUMPER 4-GRN/YEL FRENCHTOP S5 SW1 SW2 SW3 SW4 SW5 SW6 CONTROL, IGNTR, VALVE 5 PT 18-BLK LINE NOT USED NEUTRAL GND GAS VALVE GAS VALVE NOT USED NOT USED CAPPER CONNECTORS LEFT REAR S1 LEFT FRONT S2 17-BLK LEFT FRONT SWITCH SW2 9-BLUE 5-WHT 14-BLK 16-BLK LEFT REAR SWITCH SW1 15-BLK 8-BLUE #820376 - Revision A - October, 2011 7-8

Sub-Zero Group Australia Pty Ltd Level 10, 469 La Trobe Street Melbourne Victoria 3000 Phone +61 3 9600 2218 subzero-wolf.com.au M F 0 5 1 74