Temperature characterisation of LPG sensors for monitoring deterioration in reinforced concrete

Similar documents
Fiber Optic Sensor technology for Non-optical parameter measurement

Long-Range Displacement Sensor Based on SMS Fiber Structure and OTDR

Detection of Solvents using a Distributed Fibre Optic Sensor

Chapter 1. Introduction

Long-distance remote simultaneous measurement of strain and temperature based on a Raman fiber laser with a single FBG embedded in a quartz plate

Optical fiber Bragg grating based intrusion detection systems for homeland security

Programmable logic controller based Fibre Bragg Grating in-ground intrusion detection system

Reinforced FBG Sensors Serve Demanding Applications

Based Fiber Optic Sensors

Use of fiber optic technology for relative humidity monitoring in RPC detectors

Optical Fiber Sensing Technology: Basics, Classifications and Applications

Fibre Optic Sensors: basic principles and most common applications

Transport research opportunities and needs: What can fibre optics do for us? Stephen James Engineering Photonics

Fiber optic distributed pressure sensor for structural monitoring applications

Link loss measurement uncertainties: OTDR vs. light source power meter By EXFO s Systems Engineering and Research Team

RAMAN SCATTERING AND OTDR BASED DISTRIBUTED SENSOR FOR TEMPERATURE MONITORING APPLICATIONS

High Spatial Resolution Distributed Fiber Optic Technique for Strain and Temperature Measurements in Concrete Structures

Characterization of High Speed Optical Detectors for Purpose of OM4 Fibre Qualification: Selective Mode Detection

Luna Technologies Webinar Series. New Rayleigh-Based Technique for Very High Resolution Distributed Temperature and Strain Sensing

Health Monitoring System Using FBG-Based Sensors for a 12-Story Building with Column Dampers.

A Fresnel Reflection-Based Optical Fiber Sensor System for Remote Refractive Index Measurement Using an OTDR

STRUCTURAL HEALTH MONITORING OF UNDERGROUND INFRASTRUCTURE

Integration of distributed strain and temperature sensors in composite coiled tubing

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

Tatsuya Yamaguchi, Hiroshi Ohno, Yu Matsumoto, Taiyo Matsumura, Yukitaka Shinoda, Takashi Ono Nihon University, Tokyo, Japan

This document is a preview generated by EVS

Two-Pipe Fiber Bragg grating Temperature Sensor Applied in Cable Trench and Cable Pit

High-resolution Photon Counting-OTDR Based Interrogation of Multiplexing Broadband FBG Sensors

Application and Use of Distributed Temperature Sensing (DTS) Technology in Transmission Cables

Omnisens DITEST TM FIBER OPTIC DISTRIBUTED TEMPERATURE & STRAIN SENSING TECHNIQUE

Sensing Technology. A company of the BRUGG Group

Overview of fiber optic sensing system: BOTDR and its applications

Integrated optical fiber shape senor modules based on twisted multicore fiber grating arrays

INTERNATIONAL TELECOMMUNICATION UNION SERIES L: CONSTRUCTION, INSTALLATION AND PROTECTION OF CABLES AND OTHER ELEMENTS OF OUTSIDE PLANT

The Optical Time Domain Reflectometry and the Fusion Splicer Laboratory exercise

Distributed Temperature Sensing

OPTICAL TIME DOMAIN REFLECTOMETRY (OTDR) Dr. BC Choudhary Professor, NITTTR, Chandigarh

Fibre Optic Basics FIA Summer Seminar 2014

Compact Raman spectrometer system for low frequency spectroscopy

Distributed Rayleigh scatter dynamic strain sensing above the scan rate with optical frequency domain reflectometry

Multitel develops components and full instruments for in-vitro and in-vivo diagnostics in the biomedical, food and drug sectors.

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

The Optical Scattering Calibration System at SNO+ IOP 2015

Investigation of the Potential Use of Blue Light in Forward Scattering Optical Smoke Chambers to Detect all UL217 Fires in the New Standard

Optical Measurement Solutions. Fiber Bragg Grating Technology

Design of the Fiber-optic Fence Warning System with Distributed Video Real-Time Display Function Qiang-yi YI and Zheng-hong YU *

A GEM-based detector for detection and imaging sparks and flames G. Volpe 1 and V. Peskov 2. Abstract

Paper 1-IS-35 / A NEW UV SENSOR METHOD FOR SEWER RENOVATION Page 1

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

Experiment Study in Optical Fiber Temperature Monitoring

Optical Fibres ELEC8350

Hot Water Making Potential Using of a Conventional Air- Conditioner as an Air-Water Heat Pump

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. YD/T Translated English of Chinese Standard: YD/T

Fiber Optic Sensors:

Case Study - Trains. Hong Kong, 2007

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

Development of optical fiber sensors for selected chemical and physical sensing applications

Optical Time Domain Reflectometry (OTDR)

Optical Fiber Sensors for Permanent Downwell Monitoring Applications in the Oil and Gas Industry

A Method for Fire Detecting by Volume and Surface Area Concentration Based on Dual Wavelengths

PC474 Lab Manual Wilfrid Laurier University 1

DEGRADATION OF OPTICAL FillERS AT CARBON-CARBON PYROLYSIS. Rockwell International Science Center P.O. Box 1085 Thousand Oaks, CA 91358

OPTICAL FIBER SOLUTIONS

Beam Loss Position Monitoring with Optical Fibres at DELTA

Contents Fibre Laser (and Sensor) Technologies

A study of Transient Performance of A Cascade Heat Pump System

Fibrlok II 2529 Universal Optical Fiber Splice

Intrusion Detection System based on Speckle Pattern change in Fiber Optic Sensors...Abdulkareem H. Dagher, Shehab A kadhim, Hawraa H.

An FT-NIR Primer. NR800-A-006

Firetuf OFC-UT-CST Fire resistant Armoured Central Tube Cable, variant in red

Sumitomo Fiber Specification SE-6** Non-Zero Dispersion Shifted Single-Mode Fiber. PureGuide SM Optical Fiber, TIA Type IVd. Issued: November 2003

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

Temperature dependent Components within the Pyroelectric Detector

PULLOUT CAPACITY OF HORIZONTAL AND INCLINED PLATE ANCHORS IN CLAYEY SOILS

Gas Temperature Measurements with High Temporal Resolution

OPTICAL TIME-DOMAIN REFLECTOMETER

DETECTION AND LOCALIZATION OF MICRO AND MULTIPHASE LEAKAGES USING DISTRIBUTED FIBER OPTIC SENSING

Fiber optic system for monitoring large earth structures

Experimental Study to Evaluate Smoke Stratification and Layer Height in Highly Ventilated Compartments

Effect of Foundation Embedment of PWR Structures in SSI Analysis considering Spatial Incoherence of Ground Motions

Piles subject to excavation-induced soil movement in clay

World Academy of Science, Engineering and Technology International Journal of Electronics and Communication Engineering Vol:2, No:6, 2008

NOVEL COMPACT SORPTION GENERATORS FOR HEAT PUMP APPLICATIONS

UVC Detection as a Potential for Alpha Particle Induced Air Fluorescence Localisation

Distributed Sensing Over Meter Lengths Using Twisted Multicore Optical Fiber with Continuous Bragg Gratings

OFS IV Optical Fibre System

New optical frequency domain differential mode delay measurement method for a multimode optical fiber

Development and Performance Assessment of a FRP Wrapped Balsa Wood Bridge Deck in Louisiana

Special Provision No. 683S28 December 2017

Return loss measurement of fiber optic components

Smart design for temperature-strain measurement using distributed fiber-optic embedded in laminated composites

Feasibility Study of Condensation Heat Exchanger with Helical Tubes for a Passive Auxiliary Feedwater System

High Sensitivity Explosives Detection using Dual-Excitation- Wavelength Resonance-Raman Detector

Sumitomo Fiber Specification SE-9** Non-Zero Dispersion Shifted (NZDF) Zero Water Peak Large Effective Area Single Mode Fiber

Interferometric optical time-domain reflectometry for distributed optical-fiber sensing

Consolidation Stress Effect On Strength Of Lime Stabilized Soil

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

Development of a Structural Health and Load Monitoring System and its Implementation into an Aircraft Flying Demonstrator

A Method for Predicting the Matric Suction of Unsaturated Soils with Soil Color Recognition

Transcription:

Temperature characterisation of LPG sensors for monitoring deterioration in reinforced concrete O'FLAHERTY, Fin <http://orcid.org/0000-0003-3121-0492>, GHASSEMLOOY, Zabih, MANGAT, Pal <http://orcid.org/0000-0003-1736-8891> and DOWKER, K. Available from Research Archive (SHURA) at: http://shura.shu.ac.uk/8340/ This document is the author deposited version. You are advised to consult the publisher's version if you wish to cite from it. Published version O'FLAHERTY, Fin, GHASSEMLOOY, Zabih, MANGAT, Pal and DOWKER, K. (2003). Temperature characterisation of LPG sensors for monitoring deterioration in reinforced concrete. In: ILCDES 2003: Integrated Lifetime Engineering of Buildings and Civil Infrastructures. Rotterdam, In-house, 1001-1006. Copyright and re-use policy See http://shura.shu.ac.uk/information.html Research Archive http://shura.shu.ac.uk

Temperature Characterisation of LPG Sensors for Monitoring Deterioration in Reinforced Concrete F.J. O'FLAHERTY Senior Lecturer f.j.oflaherty@shu.ac.uk Z. GHASSEMLOOY Professor z.f.ghassemlooy@shu.ac.uk P.S. MANGAT Professor p.s.mangat@shu.ac.uk K.P. DOWKER Formerly Research Assist. paul.dowker@hsl.gov.uk His main research interests are in the field of maintenance and repair of reinforced concrete infrastructure. He has numerous publications to date on this topic. He is a Chartered Engineer and a member of the Institution of Engineers of Ireland. Main research interests are in the areas of high-speed optical network systems, optical wireless communications and optical fibre sensors. He has published extensively to date in these fields. He is a Chartered Engineer and a member of IEE and IEEE. He has published extensively in the fields of fibre reinforced concrete and performance of reinforced concrete repair. He is member of ACI and RILEM technical committees. He is a Chartered Engineer and member of the ICE and IStructE. His research is centred on the development of Long Period Gratings (LPGs) for use as sensors. He is currently employed by the Health & Safety Executive in Sheffield. Summary Optical fibre technology is increasingly being used to monitor stresses and strains in structural members, thus leading to the development of intelligent structures. A research project is currently underway to further expand on the development of optical strain sensors by developing sensors for deterioration monitoring in reinforced concrete. A prototype sensor based on long period fibre gratings (LPGs) is being produced that will detect chemical changes within the concrete and on the steel reinforcement surface, thus indicating initiation of corrosion. Novel coatings will be adhered to the surface of the LPG which react with chemical changes and corrosion inducing substances at the steel/concrete interface thus changing the optical properties of the LPG. The paper presents the results of preliminary tests to characterise the LPG for temperature variations. The purpose of the tests is twofold: firstly, to determine if the LPG is sensitive to a varying external medium and secondly, to compensate for the effects of temperature in the working sensor. It is shown that the temperature coefficients for the LPGs considered do not vary too much if water is used as the external medium instead of air. It is also shown that the temperature response of LPGs can be both positive and negative. Low order resonance bands are shown to be as sensitive to temperature changes as high order bands. Finally, the importance of keeping LPGs taut when testing is emphasised as results are affected by bend-induced spectral changes. Keywords: Long period gratings, sensors, temperature, concrete deterioration 1001

1 Introduction Optical fibre technology involves the transmission of light through a transparent fibre waveguide of plastic or glass. By controlling the light source, a signal representing information is transmitted through the optical fibre from the signal source to the receiver. The optical signal features distinct amplitude, phase, frequency or polarisation characteristics. Generally, an optical fibre consists of a glass fibre core surrounded by some form of cladding and protective coating and may carry one (single-mode) or many modes (multi-mode) of lightwave (Figure 1). Typical core diameters range from 5 to 50 µm, with cladding and coating diameters of 125 and 150 µm respectively [1]. Λ Figure 1 Schematic diagram of the LPG fibre sensor Optical fibres are classified as intrinsic if the effect of the measurand on the light being transmitted takes place in the fibre. The sensor is considered extrinsic if the fibre carries the light from the source and to the detector, but the modulation occurs outside the fibre. optic sensors may be divided into two main categories: intensiometric and interferometric. Intensiometric sensors are simply based on the amount of light detected through the fibre [2]. An interferometric sensor is based on the detection of changes in the phase of light emerging out of a single mode fibre. Long period gratings written in optical fibres are becoming increasingly important in fibre optics communications and optical sensing. LPGs were first presented by Versangkar et al [3] as optical filters in 1995. LPGs are made by illuminating photosensitive fibres with intense UV light in order to create a periodic increase in the refractive index of the core along the length of the fibres. The fundamental mode travelling in the core is diffracted by the gratings and is excited to cladding modes which are quickly attenuated. Hence, loss bands or resonance bands are observed in the transmission spectrum. For an LPG of a given periodicity and index modulation, the wavelengths at which the loss bands appear depend on the ambient temperature among other factors. Hence, the temperature characteristics of LPGs are very important in both communication and sensing applications. Optical fibre technology has been used extensively in the past for structural strain monitoring, partly due to the size of the fibre which does not affect the properties of the concrete in which they are embedded [2]. The ability to interrogate numerous sensors multiplexed along a single fibre permits an entire structure to be fitted with sensors with a manageable number of leads routed to central points. 2 Applications to Date There is widespread use of optical fibre technology in infrastructure monitoring to date, mainly for strain monitoring but more recently, they have been used to monitor corrosion in reinforced concrete structures. For example, fibre optic sensors have been embedded in several newly constructed civil structures, including bridges, buildings and dams yielding information about static and dynamic strain, temperature, wind or water pressure and structural health [2]. A multiplexed Bragg grating optical fibre monitoring system was designed and integrated at the construction stage in an experimental full scale laboratory bridge. The network of sensors was used to measure the strain throughout the bridge, with sensors bonded to the tension steel in the slab, and attached to the bottom flange of the girders [4]. With regards to corrosion monitoring, a multiple parameter sensing fibre optic sensor was embedded into roadway and bridge structures to provide an internal measurement and assessment of 1002

its health. The presence of corrosion was determined via colour modulation of the broadband. The input light emerges from the fibre at its end and if the fibre is in close proximity (<10 mm) to the corroding rebar, the light signal illuminates the rebar, is colour modulated with respect to the surface colour of the localised region of the rebar, and is reflected with some of the reflected signal injected back into the optical fibre. The colour modulated signal then travels back down the fibre and is sensed via standard spectroscopy. A colour shift in the input signal indicates that corrosion is present [5]. However, a significant downside to the effectiveness of this sensor is that it is difficult to ensure that the fibre is in the proximity of the rebar and the exit light is not obstructed by the constituents of the concrete. The fibres are small in size (typically less than 100 nm in diameter) and they present very small entrance and exit apertures. As such, it is difficult to launch and receive significant amounts of light when using these multimode optical fibres. 3 Experimental Procedure In this paper, 3 different LPGs were tested to establish their temperature characteristics. The LPGs are referred to as fibres A, B and C and the specifications of each are given in Table 1. s A and C each exhibited one loss band at 1551.2 and 1566.6 nm respectively when tested at 24 C, whereas Table 1 Specification of LPGs Type of Grating Period, Λ (µm) A Corning 700 1551.2 Resonance Wavelength in Air 24 o C (nm) B " 410 1304.0 & 1557.3 C " 700 1566.6 3.1 Temperature Response in Air two loss bands were observed at 1304.0 and 1557.3 nm for B. The temperature response of the LPGs was determined with either air or water as the ambient medium. In both cases the wavelength shifts was determined using an optical spectrum analyser (HP 86140A) which had two built-in LEDs centred at 1310 nm and 1550 nm. To determine the temperature response in air, the set-up shown in Figure 2 was adopted. s A, B and C were each tested in turn. The fibres were held straight between two holders with the gratings passing through an oven in the set-up (Figure 2). The temperature of the oven was controlled by varying the applied voltage using a stabilised power supply. The oven temperature Optical Spectrum Analyser Oven Figure 2 Experimental set-up for temperature response of LPGs in air 3.2 Temperature Response in Water Thermometer Stabilised Power Supply Gratings Holder was increased to 64 C and the corresponding locations of resonance bands were periodically recorded as the temperature dropped. A decrease in temperature was achieved by reducing the applied voltage to the power supply. Results are given in Section 4. The temperature response of the fibres in water was determined through the use of a water bath as shown in Figure 3. Again, the LPG was kept taut between two clamps with the gratings submerged in the hot water (maximum temperature 40 C). The resonance wavelengths were recorded as the water cooled to room temperature. Cold water was added to further reduce the temperature to 8 C. The wavelengths of the resonance bands were again periodically recorded using an optical spectrum analyser (OSA) as the temperature decreased and are presented in Section 4. 1003

Optical Spectrum Analyser Thermometer Water Water Bath Clamps Figure 3 Experimental set-up for temperature response of LPGs in water 4 Experimental Results and Discussions Gratings 4.1 Temperature Sensitivity in Air and Water The datum resonance wavelength for A was 1551.2 nm at 24 C (room temperature). The maximum air temperature employed was 64 C and the minimum was 24 C. The shift in wavelength due to a reduction in air temperature was recorded and is shown in Figure 4 (Graph α). A temperature coefficient of -0.2569 nm/ o C was obtained for A from the best fit equation of the line (the negative temperature response is explained later in the paper). wavelength shift (nm) 4 3 2 1 0-1 -2-3 -4-5 -6-7 -8-9 -10-11 -12 Graph ß medium used: water temp coefficient: -0.2429 nm/ o C Note:? at 24 o C: 1551.2 nm 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Graph α medium used: air temp coefficient: -0.2569 nm/ o C Figure 4 Wavelength shift in A due to temperature variations The same fibre (LPG A) was tested for temperature response with water as the ambient medium instead of air. The temperatures ranged between a high of 40 C and a low of 8 C. Graph ß (Figure 4) shows the temperature response of the LPG. The temperature coefficient was found to be -0.2429 nm/ o C which is similar to the temperature coefficient when tested in air. In practice, the index of refraction of most fluids reduces with an increase in temperature. Since LPGs are sensitive to external index changes [6], a wavelength shift due to the thermal-induced refractive index will occur and this will add to the temperature sensitivity of the grating. Therefore, a higher temperature coefficient for water would be expected. However, the change in temperature involved in this experiment was too small too cause any significant change in the two temperature coefficients. 4.2 Positive and Negative Temperature Responses The temperature experiment using air as a medium was repeated using LPG B and testing was performed in the 1550 nm region to allow comparisons to be made with the test results in air from LPG A. The air temperature ranged between 63.5 C and 24 C as shown in Figure 5 and Table 2. The temperature coefficient obtained from the best fit line in Figure 5 was +0.0595 nm/ o C. This positive temperature coefficient implies that the grating is operating in the normal region. However, the temperature coefficient obtained for LPG A (Figure 4, Graph α) was negative (-0.2429 nm/ o C) and this implies that LPG A was operating in the anomalous region at the wavelength considered [7]. 1004

Wavelength (nm) 1560.0 1559.5 1559.0 1558.5 1558.0 1557.5 Wavelength = 0.0595 ( o C) + 1555.8 1557.0 20 25 30 35 40 45 50 55 60 65 70 Figure 5 Temperature profile of LPG B in air (1550nm region) Table 2 Temperature results for LPG B in air (1550nm region) Temperature ( C) Resonance wavelength (1550nm region) 63.5 1559.6 56 1559.2 51 1558.7 35.5 1557.8 24 1557.2 Hence, it is shown that the temperature profile of LPGs can be both positive and negative depending upon the characteristics of the gratings at the wavelength considered. The temperature coefficient for LPG B (+0.0595 nm/ o C) is one order of magnitude lower that that for LPG A (- 0.2569 nm/ o C). Hence, LPG B is less affected by temperature variations and can therefore be used for purposes which require the LPG to remain unaffected by small changes in temperature. 4.3 Temperature Sensitivity of Different Resonance Bands A major advantage of LPGs is the presence of multiple resonance bands which can be used for multi-parameter sensing [7]. In the current investigation, LPG B exhibited two resonance bands at 1304.0 and 1557.3 nm and their response to variations in air temperature is presented. The temperature coefficient for LPG B when tested in air in the 1550nm band is +0.0595 nm/ o C as shown in Figure 5. Figure 6 shows the shift in the resonance wavelength at 1304 nm for the same fibre (LPG B) when also tested in air. The temperature coefficient obtained was +0.0505 nm/ o C Wavelength (nm) 1307.0 1306.5 1306.0 1305.5 1305.0 1304.5 1304.0 1303.5 1303.0 Figure 6 Temperature profile of coupling wavelength of LPG B in air (1310nm region) 4.4 Bend-Induced Spectral Changes Wavelength = 0.0505 ( o C) + 1302.9 20 25 30 35 40 45 50 55 60 65 70 (Figure 6) which is very similar to that obtained for the 1550nm resonance band (+0.0595 nm/ o C, Figure 6). This shows that lower order bands can be as sensitive to temperature variations as higher order bands. Hence, in multi-parameter sensing, lower order bands can be used to monitor temperature changes while higher order bands can be used to detect external index changes [7]. LPG C was used in the water bath to determine the response to temperature variations. The water temperature ranged between 27 o C and 48 o C. In this test, the LPG was not tensioned by the clamps. The response to temperature variations is shown in Figure 7. Referring to Figure 7, a linear relationship was evident at higher temperatures (between 33 o C and 48 o C). However, at lower temperatures (27 o C to 33 o C), two dips were observed on the spectrum analyser and the temperature response was no longer linear (Figure 7). This is probably due to bend-induced spectral changes which occurred when testing at lower temperatures. This depicts the importance of keeping the fibre taut when using LPGs. 1005

Wavelength (nm) 1576.0 1574.0 1572.0 1570.0 1568.0 1566.0 1564.0 1562.0 1560.0 1558.0 25 30 35 40 45 50 Figure 7 Graph of wavelength against temperature for C when tested in water 5 Conclusions The following conclusions are obtained from laboratory tests to characterise LPGs for temperature variations: the temperature coefficients for water and air are similar LPGs can exhibit both positive and negative temperature profiles depending on whether they are operating in the normal or anomalous region LPGs can be used for multi-parameter sensing since low order bands are as sensitive to temperature as high order bands LPGs should be taut when testing as bends in the fibre influence the measured wavelength 6 Acknowledgements The information presented in this paper is from a research project entitled 'Utilisation of LPG sensors for monitoring deterioration processes in reinforced concrete'. The authors wish to acknowledge the financial support provided by The Engineering and Physical Sciences Research Council (EPSRC). 7 References [1] Barnes, R.A., Mays, G.C., "Smartcrete - The use of Optic Sensors in concrete", BCA Annual Conference, Cardiff, UK. 8-9 July 1999, pp. 199-210 [2] Merzbacher, C.I., Kersey, A.D., Friebele, E.J., " Optic Sensors in Concrete: A Review". Smart Mater. Struct. 5, 1996, pp. 196-208. [3] Vengsarkar, A.M. et al, "Long-period fiber gratings as band-rejection filters", Journal of Lightwave Technology, 14, 1996, pp. 58. [4] Idriss, R.L., Kodindouma, M.B., Kersey, A.D., Davis, M.A. "Multiplexed Bragg Grating Optical Fiber Sensors for Damage Evaluation in Highway Bridges", Smart Mater. Struct. 7, 1998, pp. 209-216 [5] Fuhr, P.L., Huston, D.R., "Corrosion Detection in Reinforced Concrete Roadways and Bridges via Embedded Optic Sensors", Smart Mater. Struct. 7, 1998, pp. 217-288 [6] Patrick, H.J., Kersey, A.D., Bucholtz, F., "Analysis of the Response of Long Period Fiber Gratings to External Index of Refraction", Journal of Lightwave Technology, Vol. 16 No. 9, 1998, pp.1606-1611. [7] Bhatia, V., "Applications of Long-Period Gratings to Single and Multi-Parameter Sensing", Optics Express, Vol. 4 No. 11, 1999. 1006