FS1. User manual FLOAT LEVEL GAUGE. No ZAM-SERVIS s.r.o. Křišťanova 1116/14 Ostrava-Přívoz

Similar documents
INSTRUCTIONS FOR OPERATION

EU DECLARATION OF CONFORMITY

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Stira e Aspira M0S O08

DUR 40Ex Intrinsically Safe SMOKE DETECTOR

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

ATEX, NOMENCLATURE AND CODING

CRU-S Series Stainless Steel Condensate Recovery Unit

TIH 300 S / TIH 400 S / TIH 500 S / TIH 700 S / TIH 900 S / TIH 1100 S

FLAMMABLE GAS DETECTOR DAX 3F-C INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FC_MAN01_EN.indd Ver. V1R2

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

ATEX, NOMENCLATURE AND CODING

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

Ex SOLENOID / ALARM DRIVER. PRepower 5203B. Table of contents. Applications Safety instructions Technical characteristics...

VQ500 Series Combustible Gas Detector Elements

Matters Needing Attention of Electrical Equipment Installation Engineering in Hazardous Areas. Wang Qiaoli

1. GENERAL TECHNICAL INFORMATION

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

ORIGINAL OPERATING INSTRUCTIONS ASH VACUUM CLEANER / 18L

Approval of Ex (Electrical) Equipment for use/installation in Hazardous Areas.

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

WHAT WHITE PAPER IS POTENTIALLY EXPLOSIVE ATMOSPHERE CERTIFICATION AND WHY YOU. June 2010

OPERATION AND MONTAGE MANUAL ROOF FANS

AIRGOCLEAN 10 E OPERATING MANUAL AIR CLEANER TRT-BA-AIRGOCLEAN10E-TC-001-EN

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

TTV 1500 / TTV 3000 OPERATING MANUAL CONVEYING FAN TRT-BA-TTV TC EN

METAL CERAMIC FAN HEATER

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Guide to Explosion Protection and Plant Safety

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

testo 316-EX gas leak detector Instruction manual

Read this manual through carefully before installing/using the cleaner, paying special attention to the SAFETY INSTRUCTIONS

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

DXAPV3N. Air Purifier. With. Enviro-neutralising Technology DXAPV3N

OPERATING INSTRUCTIONS

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Installation, Operating and Servicing Instructions

ATM Lighting sp. z o.o

HYTEK ATEX APPROVED BUND ALARM

Inductive slot sensor

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Polti S.p.A. reserves the right to change equipment or accessory specification without prior notice.

Submersible Garden Pump USER'S MANUAL

MODEL: SP2nd (Portable Single Gas Detector) Operating Manual

INTRINSICALLY SAFE LIGHTING RANGE

IECEx Certificate of Conformity

LUCCI AIRFUSION BREEZE WALL FAN INSTALLATION OPERATION MAINTENANCE WARRANTY INFORMATION CAUTION READ INSTRUCTIONS CAREFULLY FOR SAFE

Survey of electrical equipment installed in hazardous areas on tankers

M-Switch Float Operated Liquid Level Switch

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

MAINS KLARGESTER SEPARATOR ALARM INSTALLATION & OPERATIONS MANUAL

MICROpeL 75 Combustible Gas Sensor Part Number: PM

instructions for use Air Purifier with ionizer _00/

SAFETY AND OPERATING MANUAL. Original Instructions 5.0

PLUG-IN PERSONAL CERAMIC FAN HEATER

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

AD.3.XG... Atex directive ch. I Page 22 Atex classification ch. I Page 23. Tab.1 Assembly ch. I Page 25

CRU 200 and 500 Series Condensate Recovery Unit Installation and Maintenance Instructions

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Reflux Extractor BM106. Impact Test Equipment Ltd & User Guide. User Guide

Junction boxes control boxes THU 93.1 THU 93.6 THU 94.1 THU 94.9 PTB 98 ATEX March 1999

Operating Instructions

The CENTURY. High Performance Oscillating Fan OWNER S GUIDE FOR MODELS 9002X & 9702X

OPERATION AND MONTAGE MANUAL ROOF FANS

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

SFE 2311BK. EN Desktop Fan. Copyright 2017, Fast ČR, a.s

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

VL FOREVER 600 INOX - VL FOREVER 600

Portable Oxygen Monitor OX-07. (Type B) <No Gas alarm type> Operating Manual

Local air conditioner

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

ENGLISH INSTALLATION AND USER S MANUAL FRENCH NOTICE D INSTALLATION ET D UTILISATION ITALIAN MANUALE D ISTRUZIONE

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

750MM INDUSTRIAL PEDESTAL DRUM FAN

Manual for Ceiling Patio Heater

ATM Lighting sp. z o.o

Ireland. Australia. New Zealand

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

SHIATSU MASSAGE CUSHION

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Dräger X-am 7000 Multi-Gas Detection

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

OPERATING INSTRUCTIONS

NATIONAL RULES FOR ELECTRICAL INSTALLATIONS IN POTENTIALLY EXPLOSIVE ATMOSPHERES. ET 105:2001 (Second Edition)

SUPPLEMENT REPORT No.: XPL/13600/

Operation Manual Airbrush Compressor AH28A ARTICLE 34247

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Translation of the assembly instructions with operating instructions and technical appendix

PERSONAL COMBUSTIBLE GAS DETECTOR

Suits all KPF849 models

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Transcription:

User manual FLOAT LEVEL GAUGE No. 201 29 This User manual includes: Instructions for assembly, installation, commissioning, use, operation, settings, maintenance and servicing, disassembly, disposal and technical conditions. Keep this manual for future use! 25.5.2017 User manual 1/9

ontents User manual...3 Use...3 Description and function...3 aution!...4 Installation and assembly...4 Operating instructions...4 Maintenance...4 Repairs and spare parts...4 Delivery, transport and storage...4 Fire safety, ecology, disposal, recycling...5 Manufacturer and service organization...5 Related standards, regulations and documents...5 Technical parameters...6 Appearance...7 Dimension Drawing...8 25.5.2017 User manual 2/9

User manual This User manual includes instructions for assembly, installation, commissioning, use, operation, setting, maintenance and servicing, disassembly and disposal, and technical specifications. All workers installing, putting into operation, operating, maintaining and servicing the unit must be demonstrably familiarized with these operating instructions. Keep this manual for future use. Use The float level gauge is intended for switching on/off control and signalling circuits depending on liquid level. Thanks to its construction, it can be used in heavy duty industrial conditions in environments with high relative humidity; it can be immersed also in mechanically polluted liquids with the specific density up to 1.4 g/cm 3 in the temperature range from +1 to 80 o. It can be used for all inflammable liquids. It is made with IP68 protection and is also designed for potentially explosive atmospheres with occurrence of methane in IM2 Ex ia Mb design according to ČSN EN 60079-1, 60079-11 for underground mines. The device can be used in the gas and monitoring system for level monitoring. Description and function The float level gauge (Fig. 2) is made as a waterproof case hanging on a wire. There is a switching mechanism inside the case. For level gauging application in potentially explosive atmospheres with occurrence of methane, the float level gauge is housed in a special enclosure. After it is immersed in a liquid, the float level gauge turns over due to the upward hydrostatic pressure and weights, and the microswitch connects or disconnects contacts. The required difference for overturning the float is from 160 to 180 mm. On Level difference Off Fig. 1. Float level gauge principle 25.5.2017 User manual 3/9

aution! 1. The device must not be used where there is a risk of mechanical damage or risk of chemical damage of the supply cable or case of the level gauge! 2. In case of mine applications, the level gauge is allowed to be connected only to intrinsically safe circuits! 3. The maximum length of the supply cable must be selected so that the values of o L o specified in the certificate of the used follow-up unit are not exceeded. Installation and assembly 1. At surface applications, protection against electric shock for the device is ensured by supplying from a safety transformer and by IP68 protection. The level gauge wire is fixed to the tank above its maximum level. In special cases when the difference of levels comes up to 5 m, it is recommended to place the level gauge behind a partition, which calms the flow of liquid, or to fix it to the tank wall. 2. For level gauging application in potentially explosive atmospheres with occurrence of methane, the float level gauge is placed in a special enclosure (see Fig.), which is to be fixed to the timbering of mine roads where we want to gauge flooding of mine roads. Operating instructions After installed, the device operates unattended. Maintenance The device is maintenance-free. However, it is necessary to check the surface of the gauge and if supply wire for integrity. It is recommended to have the unit checked by personnel from the manufacturer or a relevant authorised representative once a year. Repairs and spare parts All repairs and spare parts are provided by the manufacturer. Delivery, transport and storage Order code: for mine Float level gauge including special structure The delivery includes: This User manual A copy of the Declaration of onformity The product itself All components must be transported with attention to reduce potential shocks and vibrations. Store 25.5.2017 User manual 4/9

in dry places at temperatures from 0 to 40 in one layer. Fire safety, ecology, disposal, recycling Do not expose to open flame; harmful substances are produced by burning. When operated properly, the product has no harmful effects on the environment and ecology. After expiration of the lifetime, return the product to the manufacturer for disposal. The address is listed below. After expiration of the lifetime, the electrical and electronic equipment may not be disposed of as ordinary municipal waste. The product must be forwarded to a relevant collection point for proper processing, regeneration and recycling of the electrical and electronic equipment. For more information about the collection point and recycling of this product, please contact the local authorities, a municipal waste management company at your place or the dealer where you purchased this product. Manufacturer and service organization ZAM - SERVIS s.r.o. Křišťanova 1116/14, 702 00 Ostrava Přívoz, phone: 596 135 422 e-mail: zam@zam.cz Related standards, regulations and documents LVD: ČSN 33 2000 4 41 Low voltage electrical installations Electric installations Part 4: Safety hapter 41: Protection against electric shock. ČSN EN 60529 ČSN EN 61558-2-1 ed2 ČSN EN 60 730-2-16 ATEX: ČSN EN 60079-0 ČSN EN 60079-11 Degrees of protection provided by enclosures (IP ode) Safety of power transformers, power supply units Part 2-1: Particular requirements for separating transformers for general use Part 2: Particular requirements for automatic electrical water level operating controls of the float type for household and similar applications Explosive atmospheres Part 0: Equipment General requirements Explosive atmospheres Part 11: Equipment protection by intrinsic safety i. 25.5.2017 User manual 5/9

Technical parameters ZAM-SERVIS s.r.o. Křišťanova 1116/14 Ostrava-Přívoz 702 00 Nominal supply voltage Surface: 48 V from safety transformer Nominal current Surface 2 A/D, 4 A/A Mine Supply voltage U i 30 V A/D Input power P i 3.07 W Inductance L i 0 apacity i 0 Service life 12 000 engagements Weight 1.3kg Dimensions ase diameter 75 mm, length 123 mm Design I M2 Ex ia Mb 25.5.2017 User manual 6/9

Appearance Level gauge & supply cable Level gauge fastening structure Fig. 2 detector appearance 25.5.2017 User manual 7/9

Dimension Drawing ZAM-SERVIS s.r.o. Křišťanova 1116/14 Ostrava-Přívoz 702 00 Supply cable attachment Tiltable cover Reinforcement holder Float Holes Vessel body Fig. 3 Fastening frame installation 25.5.2017 User manual 8/9

DKD11-IO 22 20 21 X1 19 18 15 16 17 DKD11-IO 22 20 21 19 X1 18 17 16 15 Fig. 3 Exaple connection with DKD11-IO, basic connection and with the rollover control. DKD11-ABV 12 DKD11-ABV X2 10 9 8 5 6 4 1 2 20 X1 18 17 12 10 9 8 X2 6 5 4 1 2 20 X1 18 17 Fig. 3 Exaple connection with DKD11-ABV, basic connection and with the rollover control. 25.5.2017 User manual 9/9