HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Similar documents
TM-3100 Series Room Temperature Sensor

T125-E. Electric Fan Coil Thermostat. Product Bulletin. Operation. Appearance. Installation, Service and Maintenance

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

TRUERH Series HE-67xx Humidity Element with Temperature Sensor

Single pressure controls for Refrigeration, Air-conditioning and Heatpump applications

Relative Humidity Transmitters

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

F261 Series Fluid Flow Switches

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

CD-Px Series Duct Mount CO 2 Transmitters

ER52 - Evaporator Controller

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Duct Humidity/Temp Sensor

Series A36 3- and 4 Stage Thermostats for Refrigeration, Cooling, Heating, Ventilation and Air-conditioning. Feature and Benefits

TrueAlarm Analog Sensing

Outside Air Humidity & Temperature Sensor

Series A28 Two stage Thermostats. Feature and Benefits

WT-4000 Series Pneumatic-to-Direct Digital Control (DDC)

Duct Temperature Sensors

Hygro/hygrothermal transducers (hygrometric)

FTK+ Application. Types Available. Duct sensor for humidity and temperature. Datasheet

Location Requirements

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QPM21 Series Duct CO 2 and Air Quality Sensors

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

Using the Model 1500 Portable Chilled Mirror Hygrometer

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

A99B Series Temperature Sensors

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

EXAMPLES OF HOW TO ORDER

ER65-DRW Controller. Heating Applications. Product Bulletin. Heating Controller

EXAMPLES OF HOW TO ORDER

Room Humidity/Temp Sensor

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Using the DewTrak II Dew Point/ Humidity Transmitter

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

Johnson Controls Fan Coil Units and Direct Digital Controls

BC-HTO RELIABLE SENSING TECHNOLOGY

ACT2-CS Convenience Store Controller

DMFPM-2R MULTIFUNCTIONAL

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Process Automation. Sensors and Systems: Level Sensors Level Switches Overfill Prevention Pressure Sensors Temperature Sensors

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Hygro/hygrothermal transducers (hygrometric)

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

for relative humidity and temperature

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Series F61. Liquid Flow Switches. Feature and Benefits. T-body and Pipe-insert types available

P266 Series Single-Phase Condenser Fan Speed Control

DESIGN MANUAL MODEL GIR900 INFRARED COMBUSTIBLE GAS SENSOR

Beck. The differential pressure transmitter for air

User manual CTX 300 CO 2

W43A Humidistat. Features and Benefits

SIMRAD GD10PE IR GAS DETECTOR

I ntroduction. Series F61. Liquid Flow Switches. Feature and Benefits

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

THM80X Series Operation Manual Industry Degree Temp. & Humidity Transmitter V 0.1

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

Carbon Monoxide CO Transmitter ADT-X3-1110

GCS Multipoint Carbon Dioxide Gas Concentration Sampler

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

SEC Signature Process Gas Analyzer

Duct Air Quality Sensors

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

Series P215LR/BR Single/Dual Pressure Input Condenser Fan Speed Controllers For Single Phase Motors (incl. built-in RFI suppression filter)

TEC2100 Series Networked Thermostats

TrueAlarm Analog Sensing

SIARGO MEMS FLOW SENSING PRODUCTS MEMS Mass Flow/Clog Sensors VC Siargo Ltd. ISO 9001 ISO OHSAS 18001

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

PolyGard Single Point Controller SPC-X3-11XX for Toxic Gases and Oxygen

OPTISENS TUR 2000 Technical Datasheet

Accuracy by Design Products for the HVAC Professional

GG-H2S HYDROGEN SULFIDE GAS SENSOR. Installation and Operation Manual

S304 and S305 Dust Emission Monitors. User Manual. Distributor

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

TEC1100 Series Thermostats

PolyGard 2-channel Gas Controller MGC-03

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Zareba Sensepoint Pro

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Gas cooler series TC-Standard+

GETTING STARTED GUIDE NI RTD, 0 Ω to 400 Ω, 24 Bit, 400 S/s Aggregate, PT100

Transcription:

HT-1300 Series Temperature and Humidity Duct Sensor Product Bulletin Specifically designed for HVAC application, the HT-130x-UD1 sensor is a highly accurate and reliable for measuring relative air humidity and temperature. The enclosure minimizes installation cost and provides outstanding protection against contamination and condensation, thus ensuring flawless operation. The HT-130x-UD1 employs the new humidity/temperature sensor with excellent long-term stability and resistance to pollutants. Long term performance is granted by the PTFE membrane fitted to the standard protection cap, suitable for most common HVAC applications. The standard protection cap can be replaced with a series of alternative protection caps specially designed for harsh environments. In combination with a long calibration experience, the HT-130X-UDx provides a humidity measurement accuracy of ±2,5%. HT-1300 Power Supply 15...35 VDC / 24 VAC Flexible application Humidity Accuracy 2.5% RH from 10 to 95% RH Suitable for a wider range of applications Temperature Outputs 0...10 VDC or Pt1000 Suitable for any field controllers Protection Caps for harsh enviroment HT-130x-UD1 Duct probes length 200 mm Easy to install. No expert required HT-130x-UD1 Protection Class IP65 It can be mounted in several environments HT-1300-CAP-10x Protection Caps For a longer term of optimal performance in harsh environments Calibration Certificate Each product is calibrated against factory standards traceable to international standard units

Calibration Certificate Each sensor is delivered with a Calibration Certificate which certifies that the product is manufactured in compliance with the latest technical standards. All used materials and components have passed the quality assurance system. Manufacturing, calibration and quality testing are performed according to the Quality Assurance System. The products are calibrated against factory standards traceable to international standards units administrated by the national metrology institutes like NIST, PTB, NBL, BEV or other recognized national standard laboratories. For engineering samples and repair parts extent of certification is restricted to test result only. 2

Installation The installation of electrical wiring must conform to local codes and carried out by authorized personnel only. Users should ensure that all Johnson Controls products are used safely and without risk to health or property. The HT-130x-UD1 series duct humidity sensors are intended to provide input to equipment under normal operating conditions. Where failure or malfunction of an HT-130x-UD1 series duct humidity sensors could lead to an abnormal operating condition that could cause personal injury or damage to the equipment or other property, other devices (limit or safety controls) or systems (alarm or supervisory) intended to warn of, or protect against, failure or malfunction of the HT-130x-UD1 sensors must be incorporated into and maintained as part of the control system. To avoid damage to the HT-130x-UD1 sensors, do not mount the unit in a harsh locations where high concentrations of corrosive vapors, O 2, or Dust are present. To mitigate the effect in the harsh environments please select the appropriate Protection caps in the HT-1300 Accessory section. Wiring Instructions For wiring follow the instructions below: All wiring must be in accordance with local regulations and national rules. Do not attempt field repairs. If the transmitter is not operating properly, even though it is wired connectly, it should be replaced. 24VAC/DC 1 8 24VAC/DC 1 GND 2 7 Pt1000 GND 2 RH% 0...10V 3 6 RH% 0...10V 3 T 0...10V 4 5 T 0...10V 4 HT-1301-UD1 HT-1302-UD1 HT-1306-UD1 3

HT-1300 Accessory The choice of appropriate filter cap is essential for the long-term performance of the sensor in a harsh environments where pollution, dust, gases or sterilization process with H 2 O 2 (hydrogen peroxide) can reduce the life of the humidity sensor. Protection Caps for harsh environments Filter Type Item code Construction Features Application HT-1300-CAP-103 Material: sintered stainless steel For high mechanical stress and strong pollution. Industrial process control Agriculture Pores size: 10μm T range: -40 180 C Life stock barns Length: 33 mm (1.30 ) (-40...356 F) Unsuitable for condensing Response time t 10/90 : 30s Environment HT-1300-CAP-105 Material: PTFE sintered Pores size: 50μm Length: 33 mm (1.30 ) For very dirty, oily environment. T range: -40 180 C (-40...356 F) Response time t 10/90 : 14s Industrial process control Chemical industry Swimming pool Very polluted environment Unsuitable for condensing HT-1300-CAP-106 Body: polycarbonate Filter: stainless steel wire mesh. Pores size: 30μm Length: 33 mm (1.30 ) For low mechanical stress and low pollution level. T range: -40 120 C (-40...248 F) Response time t 10/90 : 15s Climate control HVAC Dryers an Humidifiers For high RH / condensing environment HT-1300-CAP-115 Material: PTFE sintered Pores size: 50μm Length: 33 mm (1.30 ) Catalytic filter for H2O2 environment. T range: -40 180 C (-40...356 F) Response time t 10/90 : 14s Pharmaceutical Biotech Sterilization with H 2 O 2 ote: Operating range is limited to the max operating range of the sensor. The standard cap provided with the HT-130x is polycarbonate body with PTFE membrane with pores size: 1μm for an excellent protection against fine dust in common dusty environments like most common HAVC and BAS applications. Response time t 10/90 : 15s. 4

Dimensions (in mm) 46 101 ~205 80.6 Ø 12 60 ±0.3 Ø >16 mm 6 90 ±0.3 Ø >13 Conduit knockout ~205 5 19 Cable gland M16x1.5 5

Ordering Codes HT-1300 Plant Humidity sensors Codes HT-1301-UD1 Humidity Working Range Humidity Output Humidity Accuracy Temperature Working Range Temperature Output HT-1302-UD1 10...95 % 0...10 VDC 2,5 % 0...40 C 0...10 VDC Supply Voltage -15...60 C 0...10 VDC 15-35 VDC HT-1306-UD1-15...60 C Pt1000 HT-1300 Accessories Filter Caps for harsh environments Codes Description Application HT-1300-CAP-103 Stainless Steel Sintered Filter cap For industrial, Agriculture, barns or 24 VAC ±20% HT-1300-CAP-105 PTFE Sintered Filter Cap For chemical and very polluted environment HT-1300-CAP-106 Polycarbonate body with Stainless Steel wire mesh Filter Cap For Cap Dryers and Humidifiers HT-1300-CAP-115 Catalytic Filter in PTFE Filter Caps For Pharm, Biotech, High Oxygen concentration, Sterilization with H 2 O 2 Standard Filter Cap replacement Codes HT-1300-CAP-103 Description Kit of 10 pcs: Mounting Flange, Cable Gland, Screws/Fishers, Gasket, and standard protection Cap, PTFE Membrane for Dusty and Building Automation applications. 6

Technical Specifications Sensor HT-1301-UD1 HT-1302-UD1 Power Supply 15-35 VDC or 24 VAC ±20% Relative Humidity HT-1306-UD1 Analog Output 0 to 100% RH Working Range Accuracy at 20 C 0-10 V - 1mA < l L < ma 10...95 RH ± 2.5% RH Temperature Dependency Typ. ±0.03% RH / C Temperature Analog Output * 0-10 V Pt1000 T-Accuracy at 20 C ±0.3 C EN60751 Class A (±0.15 C + 0.002* T C) Output Analog Passive * Output scaling see "Ordering Codes" table Current Consumption Analog With DC power supply typ. 5 ma With AC power supply typ. 13 ma Connection Screw terminals, max 1.5 mm 2 Housing / Protection Class Polycarbonate (UL listed) / IP65 Cable Gland M16 x 1.5 Sensor Protection Electromagnetic Compatibility Temperature Ranges Operating Temperature Storage Temperature Compliance Standard Cap - PTFE Membrane filter Protection Caps for harsh environment optional EN61326-1 EN61326-2-3-15...60 C (5...140 F) -25...60 C (-13...140 F) Johnson Controls, Inc., declares that these products are in compliance with the essential requirements and other relevant provisions of the EMC Directive 2004/108/EC The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from misapplication or misuse of its products. Building Efficiency Headquarters: Milwaukee, Wisconsin, USA Branch Officies: Principal Cities World-wide Metasys and Johnson Controls are registered trademarks of Johnson Controls, Inc. All other marks herein are the marks of their respective owners. Copyright 2015 Johnson Controls, Inc. All rights reserved. Any unauthorized use or copying is strictly prohibited. www.johnsoncontrols.com