Planting Irrigation

Similar documents
Facility Fire-Suppression Water-Service Piping

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

SECTION DRY-PIPE SPRINKLER SYSTEMS

WET-PIPE SPRINKLER SYSTEMS

A. This Section includes the following domestic water piping specialties:

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

Division 23 - HVAC Switzerland Beallsville K-12. Section HYDRONIC PIPING SECTION HYDRONIC PIPING PART 1 - GENERAL

SECTION HYDRONIC PIPING

NATURAL GAS PIPING

B. Related Sections: The following Sections contain requirements that relate to this Section.

MLA Architects Pierz Public Schools ISD #484 Healy High School Multi-Purpose & Choir Additions Pioneer Elementary School Class Room Addition Pierz, MN

SECTION DOMESTIC WATER PIPING SPECIALTIES

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

SPRINKLERS TABLE OF CONTENTS

REFRIGERANT PIPING

Ratio Architects, Inc. Section Refrigerant Piping

North Hanover Township School District North Hanover Township, New Jersey

VALVES SECTION 15100

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION REFRIGERANT PIPING

B. Standard-Pressure Standpipe Piping: Fire-suppression standpipe piping designed to operate at working pressure 175 psig (1200 kpa) maximum.

ADDENDUM #3 DATE: August 8, 2018 Page 1 of 1. The Curators of the University of Missouri

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

ACADEMIC SUCCESS CENTER THE COLLEGE AT BROCKPORT STATE UNIVERSITY OF NEW YORK PROJECT NO

D-11 OUTLINE SPECIFICATION FOR HTHW (ABOVE GRADE) HYDRONIC PIPING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 21 FIRE SUPPRESSION

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

1.02 SUMMARY A. This Section includes piping and specialties for combined potable-water and fire-protection water service outside the building.

Valve Pressure and Temperature Ratings: Not less than indicated and as required for system pressures and temperatures.

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

B. Utility-furnished products include water meters that will be furnished to the site, ready for installation.

PROJ. NO SECTION REFRIGERANT PIPING

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

A. Standard-Pressure Piping System Component: Listed for 175-psig minimum working pressure.

MASTERSPEC Full Length

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

University of Delaware

B. Shop Drawings: Detail fabrication of pipe anchors, hangers, special pipe support assemblies, alignment guides, expansion joints and loops,

THE JAMES RUSHTON EARLY LEARNING AND FAMILY SUCCESS CENTER #2616 ISSUE FOR CONSTRUCTION

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following sanitary drainage piping specialties:

Fire Pump Specification

WATERSTONE ASSISTED LIVING AND MEMORY CARE

SECTION (15530) - REFRIGERANT PIPING

SECTION (15530) - REFRIGERANT PIPING

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

1. Product Data for Prerequisite EQ 1: Documentation indicating that units comply with ASHRAE 62.1, Section 5 - "Systems and Equipment.

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION PREACTION SPRINKLER SYSTEMS

A. This Section includes the following fire-suppression piping inside the building:

Copyright 2016 AIA MasterSpec Full Length 09/16 PRODUCT MASTERSPEC LICENSED BY AVITRU, LLC TO VICTAULIC COMPANY.

REFRIGERANT PIPING SYSTEM

Council Bluffs, Iowa Division TOC 1 TABLE OF CONTENTS DIVISION 21 FIRE SUPPRESSION

Engineering Specifications

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 21 FIRE SUPPRESSION

Flow Control for Fire Protection

Lee s Summit West High School Boiler #3 Replacement SECTION CONDENSING BOILERS

SECTION LABORATORY and DE-IONIZED WATER SYSTEMS STANDARD CONSTRUCTION STANDARD

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

SECTION WET-PIPE SPRINKLER SYSTEMS

SECTION HEATING AND AIR CONDITIONING PIPING SYSTEMS. A. Provisions of Division 01 apply to this section. 1. Chilled Water System.

CubeSmart Gulf Breeze Storage AUTOMATIC FIRE SPRINKLER SYSTEM

SECTION FIRE-SUPPRESSION SYSTEMS

Flow Control for Fire Protection

SECTION FIRE-SUPPRESSION PIPING

SECTION BASIC MATERIALS AND METHODS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

FIRE PROTECTION. 1. Vertical fire pumps shall not be used at the University.

Wayne State University WSU Project No Chatsworth Tower Apts. Misc. Bldg. Upgrades DSD Project No

DESIGN GUIDELINES SPLIT TYPE AIR TO AIR HEAT PUMPS PAGE 1 of 6

DIVISION 21 FIRE PROTECTION ISSUE DATE REVISION

WATERSTONE ASSISTED LIVING AND MEMORY CARE COMMON WORK FIRE SUPPRESSION BATON ROUGE, LOUISIANA SECTION

A. This Section includes pipe and fitting materials, joining methods, special-duty valves, and specialties for the following:

. ECTION METERS AND GAGES

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

PROJECT NAME: DPW Idaho State University Liberal Arts Building Chiller Replacement

Copyright 2016 AIA MasterSpec Full Length 09/16 PRODUCT MASTERSPEC LICENSED BY AVITRU, LLC TO VICTAULIC COMPANY.

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION SECTION DESIGN REQUIREMENTS

D-8 OUTLINE SPECIFICATION FOR HTHW HEAT EXCHANGERS

SECTION SLEEVES AND SLEEVE SEALS FOR FIRE-SUPPRESSION PIPING

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

TECHNICAL. Series 18. Pump Packages

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

HVAC BASIC MATERIAL AND METHODS 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

DIVISION 21 FIRE SUPPRESSION SECTION FIRE PROTECTION SPECIALTIES

END OF SECTION

SECTION SPRINKLER SYSTEMS

SECTION ELECTRICAL GENERAL PROVISIONS

A. General provisions and other plumbing systems are specified in other Sections of Division 22.

1.2 CODES AND REGULATIONS A. Sprinkler system design, equipment, materials, devices, and installation shall conform to the following:

West District Library Section Campeau Drive, Ottawa SPRINKLER SYSTEMS City of Ottawa Project No. CR Page 1 of 8

DIVISION 21 FIRE SUPPRESSION FIRE SUPPRESSION GENERAL PROVISIONS .1 PREPARATION OF CONTRACT DOCUMENTS

NITROGEN-GENERATING SPRINKLER CORROSION INHIBITING SYSTEM

Transcription:

University of New Hampshire University of New Hampshire Scholars' Repository Division 32 Exterior Improvements Chapter 5 Technical Construction and Renovation Standards 1-25-2013 328400 - Planting Irrigation Sandra Hickey sandra.hickey@unh.edu Follow this and additional works at: http://scholars.unh.edu/pdch_5_32 Recommended Citation Hickey, Sandra, "328400 - Planting Irrigation" (2013). Division 32 Exterior Improvements. 13. http://scholars.unh.edu/pdch_5_32/13 This Article is brought to you for free and open access by the Chapter 5 Technical Construction and Renovation Standards at University of New Hampshire Scholars' Repository. It has been accepted for inclusion in Division 32 Exterior Improvements by an authorized administrator of University of New Hampshire Scholars' Repository. For more information, please contact nicole.hentz@unh.edu.

328400 - Planting Irrigation This article is available at University of New Hampshire Scholars' Repository: http://scholars.unh.edu/pdch_5_32/13

SECTION 32 8400 PLANTING IRRIGATION 1.1 SUMMARY A. Section Includes: 1. Piping. 2. Manual valves. 3. Automatic control valves. 4. Automatic drain valves. 5. Sprinklers. 6. Quick couplers. 7. Controllers. 8. Boxes for automatic control valves. 1.2 PERFORMANCE REQUIREMENTS A. Irrigation zone control shall be automatic operation with controller and automatic control OR manual operation with manual valves. B. Location of Sprinklers and Specialties: Design location is approximate. Make minor adjustments necessary to avoid plantings and obstructions such as signs and light standards. Maintain 100 percent irrigation coverage of areas indicated. C. Delegated Design: Design 100 percent coverage irrigation system, including comprehensive engineering analysis by a qualified professional engineer, using performance requirements and design criteria indicated. D. Minimum Working Pressures: The following are minimum pressure requirements for piping, valves, and specialties unless otherwise indicated: 1. Irrigation Main Piping: 200 psig (1380 kpa). 2. Circuit Piping: 150 psig (1035 kpa). 1.3 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. 1.4 PIPES, TUBES, AND FITTINGS A. Comply with requirements in the piping schedule for applications of pipe, tube, and fitting materials, and for joining methods for specific services, service locations, and pipe sizes. PLANTING IRRIGATION 32 8400-1

B. Galvanized-Steel Pipe: ASTM A 53/A 53M, Standard Weight, Type E, Grade B. 1. Galvanized-Steel Pipe Nipples: ASTM A 733, made of ASTM A 53/A 53M or ASTM A 106/A 106M, Standard Weight, seamless-steel pipe with threaded ends. 2. Galvanized, Gray-Iron Threaded Fittings: ASME B16.4, Class 125, standard pattern. 3. Malleable-Iron Unions: ASME B16.39, Class 150, hexagonal-stock body with ball-and-socket, metal-to-metal, bronze seating surface, and female threaded ends. 4. Cast-Iron Flanges: ASME B16.1, Class 125. C. Ductile-Iron Pipe with Push-on Joint: AWWA C151, with push-on-joint bell and spigot ends. 1. Push-on-Joint, Ductile-Iron Fittings: AWWA C110, ductile- or gray-iron standard pattern or AWWA C153, ductile-iron compact pattern. a. Gaskets: AWWA C111, rubber. D. Soft Copper Tube: ASTM B 88, Type L (ASTM B 88M, Type B), water tube, annealed temper. 1. Copper Pressure Fittings: ASME B16.18, cast-copper-alloy or ASME B16.22, wrought-copper solder-joint fittings. Furnish wrought-copper fittings if indicated. 2. Bronze Flanges: ASME B16.24, Class 150, with solder-joint end. 3. Copper Unions: MSS SP-123, cast-copper-alloy, hexagonal-stock body, with ball-and-socket, metal-to-metal seating surfaces and solder-joint or threaded ends. E. Hard Copper Tube: ASTM B 88, Type L (ASTM B 88M, Type B), and ASTM B 88, Type M (ASTM B 88M, Type C), water tube, drawn temper. 1. Copper Pressure Fittings: ASME B16.18, cast-copper-alloy or ASME B16.22, wrought-copper solder-joint fittings. Furnish wrought-copper fittings if indicated. 2. Bronze Flanges: ASME B16.24, Class 150, with solder-joint end. 3. Copper Unions: MSS SP-123, cast-copper-alloy, hexagonal-stock body, with ball-and-socket, metal-to-metal seating surfaces and solder-joint or threaded ends. F. PE Pipe with Controlled ID: ASTM F 771, PE 3408 compound; SIDR 11.5 and SIDR 15. 1. Insert Fittings for PE Pipe: ASTM D 2609, nylon or propylene plastic with barbed ends. Include bands or other fasteners. G. PVC Pipe: ASTM D 1785, PVC 1120 compound, Schedules 40 and 80. 1. PVC Socket Fittings: ASTM D 2466, Schedules 40 and 80. 2. PVC Threaded Fittings: ASTM D 2464, Schedule 80. 3. PVC Socket Unions: Construction similar to MSS SP-107, except both headpiece and tailpiece shall be PVC with socket ends. PLANTING IRRIGATION 32 8400-2

H. PVC Pipe, Pressure Rated: ASTM D 2241, PVC 1120 compound, SDR 21 and SDR 26. 1. PVC Socket Fittings: ASTM D 2467, Schedule 80. 2. PVC Socket Unions: Construction similar to MSS SP-107, except both headpiece and tailpiece shall be PVC with socket or threaded ends. 1.5 PIPING JOINING MATERIALS A. Pipe-Flange Gasket Materials: AWWA C110, rubber, flat face, 1/8 inch (3.2 mm) thick unless otherwise indicated; full-face or ring type unless otherwise indicated. B. Metal, Pipe-Flange Bolts and Nuts: ASME B18.2.1, carbon steel unless otherwise indicated. C. Brazing Filler Metals: AWS A5.8/A5.8M, BCuP Series, copper-phosphorus alloys for general-duty brazing unless otherwise indicated. D. Solder Filler Metals: ASTM B 32, lead-free alloys. Include water-flushable flux according to ASTM B 813. E. Solvent Cements for Joining PVC Piping: ASTM D 2564. Include primer according to ASTM F 656. F. Plastic, Pipe-Flange Gasket, Bolts, and Nuts: Type and material recommended by piping system manufacturer unless otherwise indicated. 1.6 MANUAL VALVES A. Curb Valves: 1. Standard: AWWA C800. B. Curb-Valve Casing: 1. Standard: Similar to AWWA M44 for cast-iron valve casings. C. Shutoff Rods for Curb-Valve Casings: Furnish one or two steel, tee-handle shutoff rod(s) with one pointed end, stem of length to operate deepest buried valve, and slotted end matching curb valve for Project. D. Brass Ball Valves: a. Crane Co.; Crane Valve Group; Crane Valves. b. Crane Co.; Crane Valve Group; Jenkins Valves. c. DynaQuip Controls. d. Flow-Tek, Inc.; a subsidiary of Bray International, Inc. PLANTING IRRIGATION 32 8400-3

e. Hammond Valve. f. Jamesbury; a subsidiary of Metso Automation. g. Jomar International, LTD. h. KITZ Corporation. i. Legend Valve. j. Marwin Valve; a division of Richards Industries. k. Milwaukee Valve Company. l. NIBCO INC. m. Red-White Valve Corporation. n. RuB Inc. a. Standard: MSS SP-110. E. Bronze Ball Valves: a. American Valve, Inc. b. Conbraco Industries, Inc.; Apollo Valves. c. Crane Co.; Crane Valve Group; Crane Valves. d. Hammond Valve. e. Lance Valves; a division of Advanced Thermal Systems, Inc. f. Legend Valve. g. Milwaukee Valve Company. h. NIBCO INC. i. Red-White Valve Corporation. j. Watts Regulator Co.; a division of Watts Water Technologies, Inc. F. Iron Ball Valves: a. Standard: MSS SP-110. a. American Valve, Inc. b. Conbraco Industries, Inc.; Apollo Valves. c. KITZ Corporation. d. Sure Flow Equipment Inc. e. Watts Regulator Co.; a division of Watts Water Technologies, Inc. a. Standard: MSS SP-72. b. CWP Rating: 200 psig (1380 kpa). c. Body Design: Split body. d. Body Material: ASTM A 126, gray iron. e. Ends: Flanged. PLANTING IRRIGATION 32 8400-4

f. Seats: PTFE or TFE. g. Stem: Stainless steel. h. Ball: Stainless steel. i. Port: Full. G. Plastic Ball Valves: a. American Valve, Inc. b. Asahi/America, Inc. c. Colonial Engineering, Inc. d. Fischer, George Inc. e. Hayward Flow Control Systems; Hayward Industrial Products, Inc. f. IPEX Inc. g. Jomar International, LTD. h. KBI (King Bros. Industries). i. Legend Valve. j. NIBCO INC. k. Sloane, George Fischer, Inc. l. Spears Manufacturing Company. m. Thermoplastic Valves Inc. n. Watts Regulator Co.; a division of Watts Water Technologies, Inc. 2. Standard: MSS SP-122. H. Iron Gate Valves, Resilient Seated: 1. Standard: AWWA C509. I. Iron Gate Valve Casings: 1. Standard: AWWA M44 for cast-iron valve casings. J. Operating Wrenches for Iron Gate Valve Casings: Furnish one or two steel, tee-handle operating wrench(es) with one pointed end, stem of length to operate deepest buried valve, and socket matching valve operating nut for Project. 1.7 AUTOMATIC CONTROL VALVES A. Bronze, Automatic Control Valves: a. Buckner; a division of Storm Manufacturing Group Inc. b. Ceres Products Company. c. Champion Irrigation Products. d. Netafim USA. e. Superior Controls Co., Inc. f. Toro Company (The); Irrigation Division. PLANTING IRRIGATION 32 8400-5

g. Weathermatic. Cast-bronze body, normally closed, diaphragm type with manualflow adjustment, and operated by 24-V ac solenoid. B. Plastic, Automatic Control Valves: a. Buckner; a division of Storm Manufacturing Group Inc. b. Ceres Products Company. c. Champion Irrigation Products. d. Dig Corporation. e. Greenlawn Sprinkler Company. f. Hit Products Corporation. g. Hunter Industries Incorporated. h. Irritrol Systems. i. Nelson, L. R. Corporation. j. Netafim USA. k. Olson Irrigation Systems. l. Orbit Irrigation Products, Inc. m. Rain Bird Corporation. n. Superior Controls Co., Inc. o. Toro Company (The); Irrigation Division. p. Weathermatic. Molded-plastic body, normally closed, diaphragm type with manualflow adjustment, and operated by 24-V ac solenoid. 1.8 AUTOMATIC DRAIN VALVES A. Description: Spring-loaded-ball type of corrosion-resistant construction and designed to open for drainage if line pressure drops below 2-1/2 to 3 psig (17 to 20 kpa). 1.9 SPRINKLERS A. General Requirements: Designed for uniform coverage over entire spray area indicated at available water pressure. B. Plastic, Exposed, Impact-Drive Rotary Sprinklers: a. Champion Irrigation Products. b. K-RAIN Manufacturing Corporation. c. Nelson, L. R. Corporation. d. Orbit Irrigation Products, Inc. e. Senninger Irrigation, Inc. PLANTING IRRIGATION 32 8400-6

a. Construction: ABS and corrosion-resistant metals. b. Mounting: Aboveground, exposed on riser. C. Plastic, Pop-up, Gear-Drive Rotary Sprinklers: a. Buckner; a division of Storm Manufacturing Group Inc. b. Champion Irrigation Products. c. Hunter Industries Incorporated. d. Irritrol Systems. e. K-RAIN Manufacturing Corporation. f. Nelson, L. R. Corporation. g. Rain Bird Corporation. h. Toro Company (The); Irrigation Division. i. Weathermatic. a. Body Material: ABS. b. Nozzle: ABS or Brass. c. Retraction Spring: Stainless steel. d. Internal Parts: Corrosion resistant. D. Plastic, Pop-up, Impact-Drive Rotary Sprinklers: a. Buckner; a division of Storm Manufacturing Group Inc. b. Ceres Products Company. c. Champion Irrigation Products. d. Nelson, L. R. Corporation. e. Toro Company (The); Irrigation Division. a. Case: ABS. b. Pop-up Height: Approximately 3 inches (75 mm). c. Sprinkler Construction: ABS and other corrosion-resistant metals. E. Plastic, Surface Spray Sprinklers: a. Ceres Products Company. b. Champion Irrigation Products. c. Hit Products Corporation. PLANTING IRRIGATION 32 8400-7

a. Body Material and Flange: ABS. b. Pattern: Fixed, with flow adjustment. F. Plastic, Surface, Pop-up Spray Sprinklers: a. Ceres Products Company. b. Champion Irrigation Products. c. Hit Products Corporation. a. Body Material and Flange: ABS. b. Pattern: Fixed, with flow adjustment. G. Plastic, Pop-up Spray Sprinklers: a. Buckner; a division of Storm Manufacturing Group Inc. b. Ceres Products Company. c. Champion Irrigation Products. d. Hit Products Corporation. e. Hunter Industries Incorporated. f. K-RAIN Manufacturing Corporation. g. Nelson, L. R. Corporation. h. Orbit Irrigation Products, Inc. i. Rain Bird Corporation. j. Toro Company (The); Irrigation Division. k. Weathermatic. a. Body Material: ABS. b. Nozzle: ABS or Brass. c. Retraction Spring: Stainless steel. d. Internal Parts: Corrosion resistant. e. Pattern: Fixed, with flow adjustment. H. Plastic Shrub Sprinklers: a. Buckner; a division of Storm Manufacturing Group Inc. b. Ceres Products Company. c. Champion Irrigation Products. d. Dig Corporation. e. Hunter Industries Incorporated. f. Orbit Irrigation Products, Inc. g. Senninger Irrigation, Inc. PLANTING IRRIGATION 32 8400-8

h. Toro Company (The); Irrigation Division. i. Weathermatic. a. Body Material: ABS or other plastic. b. Pattern: Fixed, with flow adjustment. 1.10 QUICK COUPLERS A. Description: Factory-fabricated, bronze or brass, two-piece assembly. Include coupler water-seal valve; removable upper body with spring-loaded or weighted, rubbercovered cap; hose swivel with ASME B1.20.7, 3/4-11.5NH threads for garden hose on outlet; and operating key. 1.11 CONTROLLERS A. Manufacturers: 1. Buckner; a division of Storm Manufacturing Group Inc. 2. Champion Irrigation Products. 3. Hit Products Corporation. 4. Hunter Industries Incorporated. 5. Irritrol Systems. 6. K-RAIN Manufacturing Corporation. 7. Nelson, L. R. Corporation. 8. Netafim USA. 9. Orbit Irrigation Products, Inc. 10. Rain Bird Corporation. 11. Superior Controls Co., Inc. 12. Toro Company (The); Irrigation Division. 13. Weathermatic. B. Description: 1. Controller Stations for Automatic Control Valves: Each station is variable from approximately 5 to 60 minutes. Include switch for manual or automatic operation of each station. 2. Exterior Control Enclosures: NEMA 250, Type 4, weatherproof, with locking cover and two matching keys; include provision for grounding. a. Body Material: Enameled-steel sheet metal, Stainless-steel sheet metal or Molded plastic. b. Mounting: Freestanding type for concrete base or Surface type for wall. 3. Interior Control Enclosures: NEMA 250, Type 12, dripproof, with locking cover and two matching keys. PLANTING IRRIGATION 32 8400-9

a. Body Material: Enameled-steel sheet metal, Stainless-steel sheet metal or Molded plastic. b. Mounting: Freestanding type for concrete base or Surface type for wall. 4. Control Transformer: 24-V secondary, with primary fuse. 5. Timing Device: Adjustable, 24-hour, 14-day clock, with automatic operations to skip operation any day in timer period, to operate every other day, or to operate two or more times daily. a. Manual or Semiautomatic Operation: Allows this mode without disturbing preset automatic operation. b. Nickel-Cadmium Battery and Trickle Charger: Automatically powers timing device during power outages. c. Surge Protection: Metal-oxide-varistor type on each station and primary power. 6. Moisture Sensor: Adjustable from one to seven days, to shut off water flow during rain. 7. Wiring: UL 493, Type UF multiconductor, with solid-copper conductors; insulated cable; suitable for direct burial. a. Feeder-Circuit Cables: No. 12 AWG minimum, between building and controllers. b. Low-Voltage, Branch-Circuit Cables: No. 14 AWG minimum, between controllers and automatic control valves; color-coded different from feedercircuit-cable jacket color; with jackets of different colors for multiple-cable installation in same trench. c. Splicing Materials: Manufacturer's packaged kit consisting of insulating, spring-type connector or crimped joint and epoxy resin moisture seal; suitable for direct burial. 8. Concrete Base: Reinforced precast concrete not less than 36 by 24 by 4 inches (900 by 600 by 100 mm) thick, and 6 inches (150 mm) greater in each direction than overall dimensions of controller. Include opening for wiring. 1.12 BOXES FOR AUTOMATIC CONTROL VALVES A. Plastic Boxes: 1. Description: Box and cover, with open bottom and openings for piping; designed for installing flush with grade. B. Drainage Backfill: Cleaned gravel or crushed stone, graded from 3/4 inch (19 mm) minimum to 3 inches (75 mm) maximum. END OF SECTION 32 8400 PLANTING IRRIGATION 32 8400-10