IN NOURISHING SECURITY.

Similar documents
PROCool Electronic Panel

Electronic data logger, 10 channel, as per European standard EN 12830

Thermometers and temperature controllers

5-stage compressor racks + 2 converter outputs

The new generation of cold room solutions. CAMAlarm Alarm Alarm

PROPlus Basic / CAMCtrl Basic

DIMENS. MIN TYPICAL MAX A 71.0 (2.795) 71.0 (2.795) 71.8 (2.826) B 29.0 (1.141) 29.0 (1.141) 29.8 (1.173)

PROPlus 3PH BASIC Electronic Panel

Temperature and moisture controller for cold room store

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

Temperature and moisture controller for cold rooms

Dixell Installing and Operating Instructions release 7.0

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

Refrigerated air dryers

EC 6-295P220S001. smart guide 2 OPERATION. 2.1 How to turn the instrument ON/OFF. If you have to turn the instrument ON/OFF:

Introduction. OM-THA2

EasyTronic III MANUAL SERVICE

CAREL IR33+ CONTROLLER

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

Updated: 17/03/2010 ELECTROLUX. CAREL ir33. Quick reference Handbook. Ver. 1.1 Eng. Pag.1/12

ER52 - Evaporator Controller

XWA11V. Walk-In Temp / Door /Alarm / Light Module

Safety Temperature Limiter STL 50 Certified to DIN EN (replaces DIN 3440)

REMOTE CONTROL FOR CHILLER MYCHILLER

Advanced temperature controller for cold rooms

Operating Instructions XWA11V XWA11V. Walk-In Temp / Door /Alarm / Light Module

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

FX BLAST CHILLER ISO ISO 9001

OPERATION AND MAINTENANCE MANUAL

MODEL URS-1: FACTORY RETROFIT PROGRAM

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

INSTALLATION & USER MANUAL

ECH 985. Electronic controller for heat pumps used in residential hot water application

plug-in, electronic digital thermostat with defrost control User manual

Operating Instructions XWA11V. XWA11V-KIT Walk-In Temp / Door /Alarm / Light Module with Mounting Box and Wiring

VERTEX VT10 SERIES PID OPERATION MANUAL MICROPROCESSOR BASED PID CONTROLLER

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

TMEF Series. SKOPE Vertical Freezer. User Manual

Label Displayed temperature Pb1 if the P4 parameter is set to 0, 1 or 2, room temperature if the P4 parameter is set to 3, incoming air temperature

MasterCase. User Manual

PARAGON Commercial Refrigeration Controls

Gas Controller Module GC-06

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

CATALOGUE 2017 ELECTRICAL BOARDS FOR REFRIGERATION

AKOSoft.

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

Gas leak detection + trapped person alarm

Gas Leak Detection Alarm

JDDT1 - Single Stage Digital Thermostat

WH7016E Thermostat Product Manual

DIGITAL TEMPERATURE RELAY TR-100

SCAN200E USER S MANUAL

Controller for controlling one evaporator EKC 414A1 REFRIGERATION AND AIR CONDITIONING. Manual

TECHNICAL MANUAL CVM 3000 C 5030 CV/04-99 GB

Electronic expansion valve controller

Table of Contents SECTION PAGE

Technicians Manual Single Compressor

ST Wiring diagram. Product description. Four-stage controller. Order number

TH146-P-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Index. 1. General description of the application Types of units controlled Types of regulation Condensation...

OPERATING MANUAL Enertronic Control System 2

technical bulletin Control Link RSC Installation Instructions

User Manual Ichill 200 L/D (Firmware version 1.7)

IMPORTANT WARNINGS. Before installing or handling the appliance please carefully read and follow the instructions described in this manual.

Danfoss gas detection units

ERC2 Control Instructions

CONTROLS MANUAL. CARRIERrtc basic & medium electronic control 48/50 EN/EH 50 HB/HF/NZ/NF. Original document

Process & TeMPerATUre UniversAl input DigiTAl MeTers

EVF815 Installer manual ver. 2.0 Code 144F815E204 EVF815

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

POCKET GUIDE 2011 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS

QUICK REFERENCE GUIDE SERIES IC100CX FW 1.8 (rel. 1.0)

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Controller for temperature control AK-CC 210

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

XC1008D -XC1011D- XC1015D and VGC810

DFZ. Cabin Control Description and operation

ST Wiring diagram. Product description. Standard temperature controller. Order number

DFZ. In Cab Control Description and Operation

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Laboratory Refrigerator/Deep Freezer TC 802

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

Standard Chiller Modular HP 1/4 Generic/Bitzer screw compressor and CAREL valve

EM300(LX) electronic digital indicator. Alarm (IF PRESENT) ON for active alarm; blinking for silenced alarm that is still present

Multi-Gas-Controller MGC2

Controller for temperature control EKC 202D1

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Please read this manual carefully before installation and use.

Danfoss gas detection units

MO n : 12JMC rév A

Packaged air conditioning unit condensed by air model RTC 07L to 30L. Technical information. Ref.: Y-R

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

Janfire Pellet Burner Boiler. for single / double burner management (Version 1.1)

MR3CCUHV Temperature/Defrost Control

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Transcription:

HOJA TÉCNICA 1400H171 Edición 02 (01 de 08) Electronic controllers for refrigeration R NEW leads the way Furthermore to control the CCPs Critical Control Points, in the HACCP Hazard Analysis Critical Control Points, it allows establish PREVENTIVE measures previously to lose CCPs control. Very useful for the SELF-CHECKING IN NOURISHING SECURITY. A major step forward in man-machine dialogue. Total information instantaneously available on the cycle, the refrigeration period and the defrost period. La gama más extensa para adaptarse a sus necesidades

HOJA TÉCNICA 1400H171 Edición 02 (02 de 08) signifies INNOVATION, quality and reliability emperature trend when it is out of regulation nformation on machine operating conditions emory of operation during last cycles THE CONTROLLER WITH INFORMATION OF THE HISTORICAL OPERATION THAT FACI- LITATES THE DIAGNOSTIC AND AVOIDS POSSIBLE FAILURES BEFORE IT TAKE PLACE: Instantaneous and total information on the cycle: Time elapsed from the last defrost. Time to go for the next defrosts. (%) in time inside rating conditions. Information on the cycle defrost period: Defrost duration time. Final defrosts temperature. Time to recover temperature after defrosting. Information on the cycle refrigeration period: Maximum temperature reached. Minimum temperature reached. (%) in time with the control relay (compressor) activated. Num. of connections per hour of the control relay (compressor). IT ALLOWS: The manufacturer: To establish the regulation conditions for the refrigeration equipment. The correct adjustment of parameters for each working condition. The user: Permanent SELF-CHECKING of the pre-set regulation conditions. Information on temperature trend. Control of the CCPs in the HACCP and set up PREVENTIVE measures. In installation and maintenance: Preventive maintenance and SELF-CHECKING up. Detection of changes in the working conditions. Detection of possible anomalies and avoidance of faults before they occur. Help in diagnosing the causes of a fault once it has occurred. COMMON FEATURES TO ALL AKOTIM: Information available is using access password. Comes with communications connector for PC. Parameters transfer. 3 digits and optional decimal point by program. Degrees, ºC or ºF, optional by program. 16A relay for compressor control. GENERAL TECHNICAL SPECIFICATIONS Temperature range: -50ºC to 99ºC (-58ºF to 211ºF) Sensors type (one included): NTC (AKO-149XX) Total accuracy (Sensor +controller): ±1ºC Relay 1 COOL (compressor or solenoid control): 16(4)A*, 250V, cosϕ=1, SPST Relay 2 R2 (defrost or fans in 2 relays versions): 8A*, 250V, cosϕ=1, SPDT Relay 2 DEF (defrost in 3 relays versions): 8A*, 250V, cosϕ=1, SPDT Relay 3 FAN (fans in 3 relays versions): 5A*, 250V, cosϕ=1, SPST Relay 4 ALARM (alarms in versions with A additional relay): 5A*, 250V, cosϕ=1, SPST Working ambient temperature: 5ºC to 40ºC Storage ambient temperature: -30ºC to 70ºC Installation category: II under CEI 664 standard Double insulation between power supply, secondary circuit and relay output.

HOJA TÉCNICA 1400H171 Edición 02 (03 de 08) TABLE OF REFERENCES AND OPTIONS: Panel DIN rail mounting mounting Power Supply 50/60Hz 230V~±10% 12V ±20% 120V~+8%-12% 230V~±10% 12V ±20% 120V~+8%-12% 1 Relay defrosts by 1 compressor stops AKOTIM-11 AKOTIM-14 AKOTIM-17 AKOTIM-21 AKOTIM-24 AKOTIM-27 2 Relays compressor + AKOTIM-12 AKOTIM-15 AKOTIM-18 AKOTIM-22 AKOTIM-25 AKOTIM-28 1+2 defrosts or fans 3 Relays 1+2+3 compressor defrosts + fans + AKOTIM-13 AKOTIM-16 AKOTIM-19 AKOTIM-23 AKOTIM-26 AKOTIM-29 The versions with 2 and 3 relays have an additional input for temperature sensor that permits the defrost end by temperature. Adding A to the reference means plus an additional 4 ALARM relay. Adding R to the reference means plus real time clock. Adding T to the reference means plus independent temperature (input for sensor). Adding E to the reference means plus digital input. Adding B to the reference means plus internal acoustic alarm buzzer. Examples:AKOTIM-12RB signifies AKOTIM-12 plus real time clock, plus internal acoustic alarm buzzer. AKOTIM-12ARTEB signifies AKOTIM-12 including the 5 options. FUNCTION AKOTIM WITH OPTIONAL INFORMATION Programming this function in P2 of parameters you can display (limitable by password L5) the data of the last complete 4 cycles Hd. It allows to technician the detection of changes in the working conditions and possible anomalies in avoidance failures and help in diagnosing the causes of a fault once it has occurred. To the user allows a permanent following of the preset working conditions and information on temperature trend when it is out of the rating. Instantaneous and total information on the cycle: tot Time elapsed from the last defrost (hours). top Time to go for the next defrost (hours). PrE Percentage time inside rating conditions (%). Information on the cycle refrigeration period: thp Maximum temperature reached (ºC/ºF). tlp Minimum temperature reached (ºC/ºF). PCo Percentage time with the control relay (compressor) energised (%). nac Number of connections per hour of the control relay (compressor) (Num./hour). L1 tfd tor L4 FR TEMPERATURES / TIMES <L3 L3 Information on the cycle defrost period: tod Defrost duration time (minutes). tfd Final defrost temperature (ºC/ºF). tor Time to recover temperature after defrosting (minutes). Parameters: L1 Parameter of maximum temperature admitted in refrigeration period. L2 Parameter of minimum temperature admitted in refrigeration period. L3 Parameter of maximum partial time admitted outside rating conditions. L4 Parameter of maximum time admitted to recover temperature after defrosting. tc Partial time with control tor relay (compressor) energised tfd L4 n FR L3 FR Number of connections in a complete cycle thp L1 FR Partial time outside rating conditions PR Refrigeration period time Graphic representation of the AKOTIM concepts in one example of complete cycle: L2 L3 FR tlp 1 2 3 4 n 1 L2 In the calculations for s PrE, nac and PCo the controller apply the formulas: PR - FR (min) PrE = x 100 PR (min) PR Hd tc1 tc2 tc3 tot tod L4 PR Hd Complet Cycle tc4 top WORKING COMPRESSOR + DEFROST Zone where the working conditions are correct with the pre-set ones. Out of this zone the controller displays the temperature flashing with the messages UP if the tendency is to rice or dn if the tendency is to lower. tcn tod Hd L4 PR nac = n PR (h) tc (min) PCo = x 100 PR (min)

HOJA TÉCNICA 1400H171 Edición 02 (04 de 08) DISPLAYING AKOTIM INFORMATION Level 1 Menus and s ALS Level 2 Alarms menu (if any is activated) AE Extern alarm activated of the digital input P9 = 2 AH The Sensor 1 temperature exceeds that programmed in A1 AL The Sensor 1 temperature is lower than that programmed in A2 Ar Low-charge clock battery or non-programmed clock alarm. If over 36h is disconnected the clock needs new programming. Ad Alarm activated if defrost ends by maximum time and A8 = 1 tid Level 2 AKOTIM information menu (if programmed in P2 and not limited by L5) Hd1 Cycle 1 Information, last complete Level 3 Values of each cycle (flashing with concept) Min. Max. thp Maximum temperature reached in refrigeration period ºC/ºF -50 +126 tlp Minimum temperature reached in refrigeration period ºC/ºF -50 +126 PCo Percentage time with the control relay (compressor) energised 0% 100% nac Number of connections per hour of the control relay (compressor) 0 99 PrE Percentage time inside rating conditions 0% 100% tfd Final defrost temperature ºC/ºF -50 +126 tod Defrost duration time 0min 99min tor Time to recover temperature after defrosting 0min 99min EP Level 3 exit Hd2 Cycle 2 Information, anterior at 1 Hd3 Cycle 3 Information, anterior at 2 Hd4 Cycle 4 Information, anterior at 3 tot Time elapsed from the last defrost 0h 99h top Time to go for the next defrost 0h 99h EP Level 2 exit Pb1 Sensor 1 (S1-TEM of control) during 25 seconds Pb2 Sensor 2 (S2-DEF of evaporator) during 25 seconds (if programmed P4) Pb3 Sensor 3 (S3 Independent of control) during 25 seconds (if programmed P4) EP Level 1 exit MENUS, PARAMETERS AND MESSAGES Level 1 Menus re Level 2 REFRIGERATION (Compressor) control parameters C0 Sensor 1 calibration (Offset) ºC/ºF -20 0 +20 C1 Sensor 1 differential (Hysteresis) ºC/ºF 1 2 20 C2 Set point upper limit ºC/ºF XX 99 126 (it cannot be set above this ) C3 Set point lower limit ºC/ºF -50-50 XX (it cannot be set below this ) C4 Compressor protection delay time: 0 0 1 0 = OFF/ON (from the last to switch-off) 1 = ON (at switch-on) C5 Protection delay time 0min 0min 99min ( for the option selected by parameter C4) C6 COOL relay (compressor) status with faulty sensor 1 0 1 2 0 = OFF 1 = ON 2 = OFF/ON (to programmed in C7 and C8) C7 COOL relay (compressor) ON, time in case of sensor 1 failure 0min 10min 99min If C7 = 0 and C8 0, the relay will always be OFF de-energised C8 COOL relay (compressor) OFF, time in case of sensor 1 failure If C8 = 0 and C7 0, the relay will always be ON energised 0min 5min 99min def Level 2 DEFROST (electric heat / hot gas bypass) control parameters d0 Elapsed time between 2 starts 0h 6h 99h d1 Maximum duration 0min 30min 99min (if not ended by temperature will do by time) d2 Type of message during defrost: (0 = display current temp.) 0 2 2 (1 = display defrost start temp.) (2 = display message def) d3 Maximum time of message added at end of defrost 0min 5min 99min d4 Final defrost temperature by sensor 2 (if programmed in P4) ºC/ºF -50 8 126 In 2 relays versions operates if P6 = 0 d5 Defrost start-up on equipment switch-on: 0 0 1 (0 = first defrost according d0) (1 = first defrost according d6) d6 Defrost start-up delay on equipment switch-on if d5=1 0min 0min 99min d7 Defrost type: 0 = Electric heat 1 = Hot gas bypass 0 0 1 Defrost by air in 2 relays versions P6 and F3 must be programmed d8 Time calculation between defrost periods: 0 0 1 (0 = Total real time) (1 = Compressor operation sum) d9 Drip time, compressor stop and FAN/R2 relay off when defrost ends 0min 1min 99min In 2 relays versions R2 operates in any case of P6

HOJA TÉCNICA 1400H171 Edición 02 (05 de 08) MENUS, PARAMETERS AND MESSAGES Level 1 Menus FAn Level 2 FANS (evaporator) control parameters F0 Fan stop temperature by sensor 2 (if programmed in P4) ºC/ºF -50 4 126 F1 Sensor 2 (F0) differential for switching the FAN/R2 relay ºC/ºF 1 2 50 A1 and A2 differential 2 relays versions R2 operates if P6 = 1 and P4 = 2/3 F2 Stop fans if compressor stops? (0 = no) In 2 relays versions R2 operates if P6 = 1 (1 = yes) 0 0 1 F3 Fan status during defrost (0 = stopped) (1 = running) 0 0 1 F4 Start-up delay after defrost (operates if it is higher than d9) 0min 3min 99min F5 Stop fan if door opens? (0 = no) (1 = yes) (door if P9 = 1) 0 0 1 AL Level 2 ALARMS (Visual, acoustic or relay) control parameters A1 Maximum, ºC above the Set Point in sensor 1 ºC/ºF 0=off 0=off 126 A2 Minimum, ºC below the Set Point in sensor 1 ºC/ºF 0=off 0=off 126 A3 Start-up temperature alarm delay (if programmed in A1, A2) 0=off 0=off 120min A4 Temp. alarm delay from end of defrost 0=off 0=off 99min A5 Temp. alarm delay from the temperature at which they operate 0=off 30min 99min A6 Temp. alarm delay from digital input disable (door if P9 = 1) 0=off 0=off 126min A7 Temp. alarm delay from digital input enable (door if P9 = 1) 0=off 0=off 126min A8 Alarms if defrost ends by maximum time: (0 = no) (1 = yes) 0 0 1 A9 Relay 4 alarm polarity configuration: (0 = with alarm relay ON) (1 = with alarm relay OFF) 0 0 1 CnF Level 2 GENERAL STATUS parameters P1 Delay for all function on power supply switch on 0min 0min 99min Programmed parameter block: P2 (0 = Unblocked, inf. AKOTIM disabled) (1 = Blocked, inf. AKOTIM disabled) 0 0 3 (2 = Unblocked, inf. AKOTIM enabled) (3 = Blocked, inf. AKOTIM enabled) P3 Initial parameters: 0 0 1 (1=yes, configure to Def and exit programming if P2 = 0) P4 Connected sensors: (1 = Sensor 1) (2 = Sensor 1 +Sensor 2) (3 = Sensor 1 +Sensor 2 +Sensor 3) (4 = Sensor 1 +Sensor 3) 1 1 4 P5 Address for equipment with communication 0 0 126 P6 Relay 2 (R2) function in 2 relays versions: 0 0 1 (0 = defrost by electric heat) (1 = fan control) P7 Temperature display mode: (0 = Whole in ºC) (1 = One decimal in ºC) (2 = Whole in ºF) (3 = One decimal in ºF) 0 0 3 P8 Displayed sensor: (1 = Sensor 1) (2 = Sensor 2) (3 = Sensor 3) 1 1 3 P9 Digital input configuration: (0 = disabled) (1 = door) (2 = external alarm) 0 0 2 P10 Contact with open door or enabled alarm: (0 = open) (1 = closed) 0 0 1 P11 Transfer parameters: (0 = disabled) (1 = send) (2 = receive) 0 0 2 P12 Program version (information) rtc Level 2 REAL TIME CLOCK parameters d10 1st defrost hour start time 0 off 23 d11 2nd defrost hour start time 0 off 23 d12 3rd defrost hour start time 0 off 23 d13 4th defrost hour start time 0 off 23 d14 5th defrost hour start time 0 off 23 d15 6th defrost hour start time 0 off 23 r1 Clock configuration: Hour 0 XX 23 r2 Clock configuration: Minute 0 XX 59 tid Level 2 AKOTIM information parameters L1 Maximum temperature admitted in refrigeration period ºC/ºF C3 126 126 L2 Minimum temperature admitted in refrigeration period ºC/ºF -50-50 C2 L3 Maximum partial time admitted outside rating conditions 0min 0min 99min L4 Maximum time admitted to recover temperature after defrosting 0min 0min 99min L5 Access password for AKOTIM parameters and information 0 0 126 EP Programming or level exit MESSAGES Fixed - Indicates defrost is being carried out. In order to display def when defrosting, def it is essential that parameter d2 is set to option 2. E1 Fixed - Sensor 1 failure (open circuit, crossed, temp.> 110ºC or temp.<-55ºc) E2 Flashing with temperature - Sensor 2 failure (open circuit, crossed, temp.> 110ºC or temp.<-55ºc) E3 Flashing with temperature - Sensor 3 failure (open circuit, crossed, temp.> 110ºC or temp.<-55ºc) E5 Fixed - Incorrect sensor configuration (see P4, P8) EE Fixed - Memory failure UP Flashing with temperature - Temperature outside AKOTIM rating conditions and increasing. dn Flashing with temperature - Temperature outside AKOTIM rating conditions and decreasing.

ºC ºF SET ºC ºF SET ºC ºF SET HOJA TÉCNICA 1400H171 Edición 02 (06 de 08) FRONT PANEL FUNCTIONS Panel mounting models: LED ºC ºC ºF LED ºF LED COOL UP key LED FAN PRG LED DEF LED ALARM SET DOWN key DOWN key When pressed for at least 5 seconds, it displays the SET POINT temperature. DIN rail-mounting models: LED ºC LED COOL ºC ºF LED FAN LED DEF LED ALARM UP key LED ºF SET key DOWN key SET key When pressed for at least 5 seconds, it displays the SET POINT temperature. Common functions: UP key When pressed for at least 5 seconds, a manual defrost is started with programmed duration. In programming, it increases the being displayed. It cancels the alarms, but they remain displayed. Press once to entry in displaying menu. DOWN key In programming, it decreases the being displayed. It cancels the alarms, but they remain displayed. LED ºC permanent: It means displaying temperature in ºC. flashing: Set Point or parameter programming phase. LED ºF permanent: It means displaying temperature in ºF. LED COOL permanent: Refrigeration COOL relay (compressor) is energised. LED FAN permanent: Control FAN relay is energised. LED DEF permanent: Indicates DEFROST in operation. LED ALARM permanent: ALARM relay energised (or acoustic alarm). flashing: Alarm detected, relay de-energised, but display maintained. DISPLAYING AKOTIM INFORMATION Level 1 Menus and s Pb of temp. in sensors Press the key. The LED ºC will be flashing and in the display will appear the first menu ALS if any alarm is activated, follows tid of AKO- TIM menu if it is programmed in P2 and not limited by L5, follows the s Pb of the temperature in each sensor. Press the key to access the next display and the key to return the previous one. Press the keys to access at Level 2. Pressing keys in the last display EP the controller will return to the current temperature display status and the LED ºC will stop flashing. TEMPERATURE DISPLAY LEVEL 1 MENUS AND VALUES LEVEL 2 ALARMS AND CYCLES LEVEL 3 VALUES Level 2 Displaying alarms and selection of last cycles - When we are in the menu selected in Level 1, press the keys to display in ALS menu the type of alarm activated or select in tid menu the cycle of the 4 last ones that you wish information. Level 3 Values (flashing) - When we are in the cycle selected in Level 2, press the keys to display the information s. Press the key to access the next and the key to return the previous one. NOTE: If no key is pressed for 25 seconds in any of the previous steps, the controller will automatically return to the current temperature display status. PROGRAMACIÓN ADJUSTING THE SET POINT TEMPERATURE The factory default is 0 ºC. Press the DISPLAY SET 5 Sec. POINT key for at least 5 seconds, it displays the 5 Sec. current and the LED ºC start flashing. Press the or keys to adjust the SET POINT to the required Press the keys to set the new. TEMPERATURE SET POINT When this operation is PARAMETERS The parameters should only be programmed or modified by personnel who are fully acquainted with the operation and possibilities of the equipment where it is applied. Level 1 Menus - Press the + keys simultaneously for at least 10 seconds. The LED ºC will be flashing programming phase and in the display will appear the first menu re. - Press the key to access the next menu and the key to return the previous one. - Pressing keys in the last display EP the controller will return to the current temperature display status and the LED ºC will stop flashing. Level 2 Parameters - Press the keys in the menu selected, the first parameter of menu will appear in the display. - Press the key to access the next parameter and the key to return the previous one. - Pressing keys in the last display EP the controller will return to Level 1 of menus. Level 3 Values - To display the current of any parameter, select de required one and press the DIS- PLAY VALUE keys. Once it is displayed, it can be modified by pressing the or keys. - Press the AC- CEPT THE NEW keys to set the new. When this operation is carried out, the programming return to Level 2 (parameters). TEMPERATURE LEVEL 1 MENUS LEVEL 2 PARAMETERS VALUE LEVEL 3 VALUES 10 Sec. 10 Sec. EXIT PROGRAMMING NOTE: If no key is pressed for 25 seconds in any of the previous steps, the controller will automatically return to the current temperature display status without modifying any of the parameters s. DISPLAY SET POINT DISPLAY VALUE CHANGE SET POINT CHANGE VALUE NEW SET POINT NEW VALUE carried out, the display will return to the current temperature display status and the LED ºC stop flashing THE NEW THE NEW

HOJA TÉCNICA 1400H171 Edición 02 (07 de 08) PARAMETERS TRANSFER AKO-14916 Tabletop server which is connected by means of the AKO-80018, 230/12V, to the power supply. Permit to transfer parameters previously recorded in one server AKO-14918, to the other controllers AKOTIM (panel mounting) without these having to be powered. AKO-14918 A portable server without supply to which, the parameters programmed in powered units AKOTIM can be copied. The parameters may then be transferred from the sever to other identical powered units. 230V Supply AKO-80018 AKO-14918 AKO-14918 AKO-14916 Transfer Transfer Power supply AKOTIM (panel mounting) Programming AKOTIM (panel or DIN rail mounting) PC COMMUNICATION The controllers AKOTIM are provided with a communications connector, permit data transmission and reception using the standard MODBUS protocol and to carry out management from PC software. This makes a centralised system for display, logging, alarms, remote teleprocessing... AKO-80021 RS232/ converter module RS232 PC type computer AKO-5003 Software for controllers and data loggers using a PC type computer. On request software with: AKO data loggers with MODBUS communications protocol and output External alarms by telephone, fax or internet. Display boards. CMOS Power management. PLC management. AKO-14917 CMOS/ converter module AKO controllers with MODBUS communications protocol Remote teleprocessing. CMOS Up to 126 units and 1200m length. When over 32 units are installed the appropriate AKO-80024 repeaters are needed.

HOJA TÉCNICA 1400H171 Edición 02 (08 de 08) ACCESSORIES Front protector DIMENSIONS Panel mounting 37 33 79 AKO-14910 In transparent plastic for panel mounting units Sheath for housing sensors in tanks 11 28,5 75 61,5 10 23 140 70,5 Ø8 Gas 1/2 thread DIN rail mounting AKO-155908 Stainless steel material Power supply transformer 47 Ø3 34 90 58 50,5 45 Power supply converter AKO-15590 120-230/12V, 3VA 70 Sensor extension cable 58 90 AKO-15589 14 a 30V /12V, 5VA 17 58 AKO-15586 3 x 0.5mm 2 cable with insulation + copper braid + PVC sheath NTC sensors AKO-14901 AKO-14902 AKO-14903 AKO-14906 L=1.5m L=2.0m L=3.0m L=6.0m L 14 Ø6 Tapered probe NTC sensor Modified polyolefin sheath and cable Ø3 Ø5 100 mm 3 m AKO-14915 Stainless steel tapered probe with 3m silicone cable 190 mm AKO Electromecànica, S.A.L. Av. Roquetes, 30-38 08812 S. PERE DE RIBES (Barcelona) Tel. (34) 938 142 700 Fax (34) 938 934 054 Internet: www.ako.es e-mail: ako@ako.es Apartado (P.O. Box), 5 08800 VILANOVA I LA GELTRÚ (Spain) 351400171 REV. 01 2.003 D.L.: B-32.594-03 Nos reservamos el derecho de suministrar materiales que pudieran diferir levemente de los descritos en nuestras hojas técnicas.