DuPont ISCEON 9 Series Refrigerants

Similar documents
DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

R-407A R-448A R-449A

DuPont FE-25 FIRE EXTINGUISHANT. Preferred Replacement for Existing Systems and the Choice for New Applications

The natural solution for domestic refrigeration

Chapter 2. Alternatives to HCFCs and their Characteristics

REFRIGERANT REFERENCE GUIDE

A: RS-45 is a non ozone depleting Drop-in replacement for R22 in most applications. A: RS-45 is a blend of R143a, R125, R134a and isobutane.

PAYING THE PIPER TABLE 1 NEOPRENE TYPE W SWELL RATES

Reference Document RD-0007-E GUIDELINES FOR THE UTILIZATION OF R-404A R-452A. Page 1 of Tecumseh Products Company LLC. All rights reserved.

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

Worldwide Marine and Offshore Services A GUIDE TO RS REFRIGERANTS FROM STAR INTERNATIONAL. Second Edition

Publication # RD-0003-E Rev 1, 10/17 SERVICE GUIDELINES HCFC R22 TO HFC REFRIGERANT BLENDS

FACT SHEET 6 Transport Refrigeration

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Scroll Chillers Transition from HCFC-22 to HFCs

Refrigerants & Cooling in renovation buildings

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

Retrofit Guidelines for DuPont ISCEON M029 (R-422D) Refrigerant

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

Flammability and the Low GWP Refrigerant Challenge

Guidance for Stationary Refrigeration & Air-Conditioning

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

EC Regulation No 842/2006 on certain fluorinated greenhouse gases

R-404A Alternative with Low Compressor Discharge Temperature

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Low GWP alternative refrigerants to R404A

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Overview of New Refrigerants and Expected Market Trends

Update on Refrigerant Blends

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

New Refrigerants & Selecting Capital Equipment

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Honeywell Refrigerant Update

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

Solstice 452A (R-452A) Reduced GWP and Discharge Temperature for Transport Refrigeration, Plug-Ins and Condensing Units

Effectively Managing the Transition to Lower GWP Refrigerants

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

natural refrigerants - global trends & developments

Making equipment decisions

The Current Path of Refrigerants

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

Update on Opteon Refrigerants

Scroll Chillers: Conversion from HCFC-22 to HFC-410A and HFC-407C

Suva refrigerants. Suva 134a (HFC-134a) for Mobile Air Conditioning. Technical Information. Introduction. Transition to HFC-134a

The complete approach to the care and management of A/C & refrigeration systems

Be sustainable while protecting your business

Refrigerant Changeover Guidelines HFC R-404A/R-407A/C/F to R-448A/R-449A. Leading the Industry with Environmentally Responsible Refrigerant Solutions

Reducing Refrigerant Leakage

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Energy Efficiency & Environmental News: CFC Replacements 1

Energy Saving & Eco-Friendly Refrigerant

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Refrigerants for commercial refrigeration applications

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

GEA Blu chillers. GEA BluAstrum, GEA BluGenium, GEA BluAir: A new generation of compact ammonia chillers

Gary Parker Refrigerants Product Manager

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Bulletin , March Electric Hot Gas Bypass Valves

Engineered for flexibility and performance

Refrigerants. Refrigerants with the Future in Mind

CHAPTER 1 INTRODUCTION

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

Harold Ag & Mobile Products

Thermodynamics I. Refrigeration and Heat Pump Cycles

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Walk-in Coolers & Freezers - OEMs, North America. Over

Honeywell Refrigerants. Retrofit Guidelines. R-404A/R-507A to: R-448A Solstice N40

Possibilities of the RAC sector transformation a technical perspective

The 10 th Three Associations Meeting JRAIA. The Japan Refrigeration and Air Conditioning Industry Association. August 31, 2016.

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - OEMs, Europe. Over

Refrigerant changeover guidelines

RAK THE OPTIMUM RANGE FROM REFCOOL THE ENERGY REVOLUTION. Industrial chillers - 0 to 200 kw

Refrigerants and lubricants

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Natural Refrigerants.

Natural refrigerant trends in EU, Japan & North America

Gary Parker Refrigerants Product Manager

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

Air conditioning 23XRV

Go Beyond Cool. coldroom.danfoss.co.uk. Danfoss Solutions for Cold Rooms Installers/Contractors, Europe. Over

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

CFC ALTERNATIVES FOR REFRIGERATION : MORE THAN 2 YEARS OF FIELD TRIALS

Exhibition Hall 1. Fachprogramm. Technical Programme

HFC-227ea FIRE SUPPRESSION SYSTEM

Air Conditioning Repairs: Maintenance Required

Go Beyond Cool. coldroom.danfoss.com. Danfoss Solutions for Cold Rooms - Installers/Contractors, Europe. Over

AUTOFROST Technical Discussions

COMPARATIVE PROPERTIES AND EFFICIENCY OF R-421A FOR RETROFIT USE TO REPLACE R-22

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

AIRAH Victoria Refrigerants Update

Positively Innovative R32 R32. Instructions for Use and Handling

Effectively Managing the Transition to Lower GWP Refrigerants

HVACR Refrigeration

Transcription:

ISCEON 9 Series Refrigerants P R O D U C T I N F O R M A T I O N G U I D E Refrigerants. The Science of Cool. TM de Nemours International S.A. 2 Chemin du Pavillon P.O. Box 50 CH-1218 Le Grand-Saconnex Geneva, Switzerland Tel: +41 22 717 5111 Fax: +41 22 717 6169 E-mail: EU-info@dupont.com www.isceon.com/uk Copyright 2008. All rights reserved. The Oval Logo,, The miracles of science, The Science of Cool and ISCEON are registered trademarks or trademarks of or its affiliates. K-10785 9/08

pioneered much of the science that makes air conditioning and refrigeration possible. With over 75 years of proven leadership in s science and technology, we offer the broadest range of solutions for new and existing equipment, and we are committed to leveraging The Science of Cool to lead the search for new cooling solutions that improve comfort and enhance the quality of life around the world. This guide contains information on our full line of ISCEON 9 Series Refrigerants to help you select the best for your application. Additional product information is available on our website, or by contacting your local Refrigerants distributor. www.isceon.com/uk ISCEON 9 Series Refrigerants Efficient and cost effective, Non-ozone-depleting, HFC retrofit s for CFC and HCFC equipment. ISCEON MO29 Multi-purpose replacement for R-22 in direct expansion equipment (Air Conditioning and Medium/Low Temperature Refrigeration) ISCEON 39TC R-12 in centrifugal chillers ISCEON MO49Plus R-12, R-413A, R-401, R-409A in automotive air conditioning and stationary air conditioning/refrigeration ISCEON MO59 Best suited to replace R-22 in small A/C (<15kW) systems ISCEON MO79 Best suited as a replacement for : R502, R402, R403, R408 series blends ISCEON MO89 R-13B1 in very low-temperature refrigeration Efficient and cost-effective. Compatible with traditional and new lubricants. Avoid costly equipment replacement. Available from a name you can trust. Refrigerants. The Science of Cool. We ve worked hard to build a website that works as hard as you do with customized sections dedicated to OEMs, distributors, service technicians and end users for a better, more efficient way to explore cooling solutions. When you re looking for high-quality, high-performance cooling solutions from a trusted source, visit www.s.dupont.com 2 3

ISCEON MO29 ISCEON MO29 is one of the leading multipurpose replacements for R-22 in existing direct expansion water chiller systems, residential, commercial air conditioning and medium/low temperature refrigeration systems. R-422D R-22 Multi-purpose replacement for R-22 in direct expansion equipment (air conditioning, water chiller systems and medium/low temperature refrigeration). Non-ozone-depleting HFC retrofit s in most cases, no change of lubricant type is needed Enables continued use of existing equipment Close match to R-22 capacity and efficiency in most systems Lower discharge temperature vs. R-22-likely to prolong the life of the compressor in some systems ISCEON MO29 is compatible with traditional and new lubricants, including mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. See Product Information Bulletin and retrofit guidelines for additional information. ISCEON 39TC ISCEON 39TC is one of the leading, non-ozonedepleting HFC retrofit s for R-12 in centrifugal chillers. R-423A R-12 Centrifugal chillers designed for R-12 Non-ozone-depleting HFC retrofit s Retrofit typically requires a single lubricant change to polyol ester without additional flushing Avoids expensive engineering changes to existing chiller equipment Enables cost-effective, continued use of existing chiller equipment Provides required cooling capacity and comparable energy efficiency vs. R-12 Similar discharge temperature and pressure vs. R-12 For most systems, only one lubricant change to polyol ester during retrofit is required. ISCEON 39TC tolerates high residual levels of mineral oil in polyol ester; therefore, no system flushing is generally required after changing the original lubricant to polyol ester. See ISCEON 39TC Retrofit Guidelines for more details. 4 5

ISCEON MO49Plus ISCEON MO49Plus is a cost-effective, non-ozonedepleting HFC retrofit for R-12 automotive and stationary air conditioning in direct expansion mediumtemperature stationary refrigeration systems. R-437A (pending) TM R-12, R-413A, HCFC-containing blends (e.g. MP39, MP66, R-409A) Automotive AC systems designed for R-12 Refrigeration systems, designed for R-12 including: food service supermarket display cases food storage and processing domestic refrigerators/freezers Provides cost-effective retrofits Non-ozone-depleting HFC retrofit in most cases, no change of lubricant type is needed Enables continued use of existing equipment ASHRAE safety classification of A1 (see AS-1 bulletin and MSDS) Provides up to 10% better cooling capacity vs. R-12 Provides similar to slightly lower energy efficiency vs. R-12 Lower discharge temperature vs. R-12 For R-12 automotive air conditioning systems, ISCEON MO49Plus is compatible with mineral oil in existing R-12 systems. In most cases, no change of lubricant type during retrofit is needed. For R-12 stationary medium-temperature refrigeration and air conditioning systems, ISCEON MO49Plus is compatible with traditional and new lubricants mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. Refer to ISCEON MO49Plus Retrofit Guidelines for more details. ISCEON ISCEON MO59 is an efficient and cost-effective, non-ozone-depleting HFC retrofit for R-22 in direct expansion air conditioning. Best suited to replace R-22 in small A/C (<15kW) systems R-417A R-22 MO59 Split air conditioning systems Note: for water chillers ISCEON MO29 is recommended Non-ozone-depleting HFC retrofit s in most cases, no change of lubricant type during retrofit is required Enables the continued use of existing equipment ASHRAE safety classification of A1 (see AS-1 bulleting and MSDS) Lower discharge temperature and pressure vs. R-22-likely to prolong the life of the compressor Has been shown to offer energy savings in some systems ISCEON MO59 is compatible with traditional and new lubricants, including mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. See the ISCEON MO59 Retrofit Guidelines for more details. 6 7

ISCEON MO79 ISCEON MO79 is one of the leading non-ozone depleting HFC s for replacing R-502 and R-402, R-403 and R-408 series HCFC-containing blends in commercial and industrial direct expansion refrigeration systems. R-422A R-22, R-502, HCFC-containing blends Best suited as a replacement for: R502, R402, R403, R408 series blends. Also R-22 in certain low temperature applications. -easier retrofit than R-404A and R-507 Non-ozone-depleting HFC retrofit s in most cases, no change of lubricant type during retrofit is required Enables continued use of existing equipment 20% lower Global Warming Potential (GWP) vs. R-404A and R-507 Provides improved cooling capacity over R-22 at many operating conditions with up to +15% at low-temperature conditions Provides comparable cooling capacity to R-404A and R-507 Field testing shows it can provide improved energy efficiency vs. R-22 Lower discharge temperature vs. R-22-likely to prolong the life of the compressor ISCEON MO89 ISCEON MO89 is a non-ozone-depleting HFC retrofit for R-13B1 in very low-temperature direct expansion refrigeration systems. None assigned R-13B1 Very low-temperature refrigeration (below 40 C to 70 C), including: freeze driers medical freezers environmental chambers Non-ozone-depleting HFC Compatible with traditional and new lubricants in most cases, no change of lubricant type during retrofit is needed After retrofit, can be topped off during service without removing the entire charge Provides cooling capabilities similar to R-13B1 ISCEON MO89 is compatible with traditional and new lubricants mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. See the ISCEON MO89 Retrofit Guidelines for details. ISCEON MO79 is compatible with traditional and new lubricants, including mineral oil, alkylbenzene and polyol ester. In most cases, no change of lubricant type during retrofit is needed. See the ISCEON MO79 Retrofit Guidelines for details. 8 9

Safe Handling Like the s they replace, ISCEON 9 Series Refrigerants are safe to use when handled properly. Because any can be hazardous when improperly handled, refer to the Material Safety Data Sheet (MSDS) for proper handling procedures. For additional safety information on ISCEON 9 Series Refrigerants, refer to bulletin Safety of Refrigerants (AS-1). For detailed information on the Properties, Uses, Storage and Handling (PUSH) of ISCEON 9 Series Refrigerants, refer to the appropriate PUSH bulletin. Product Availability ISCEON 9 Series Refrigerants are available from our global network of Refrigerant distributors. To find the local Refrigerant distributor nearest to you, visit www.isceon.com/uk Refrigerants Vision: The Science of Cool We will use our science and technology, market knowledge and global reach to provide sustainable materials and solutions to enhance personal comfort, enable food preservation, improve industrial processing and reduce environmental footprints. or call us at +41 22 717 5111 or fax at +41 22 717 6169 or e-mail at EU-info@dupont.com 10 11