Instruction manual SPU II Hard alarm output contacts

Similar documents
Instruction manual APU Hard alarm output contacts

Instruction manual ICU Hard alarm output contacts

Instruction manual 640 Securiterre

Installation guide 864 MTT Multi Thermo sensor Thermometer

Terminal Automation Solutions

Installation Guide SmartRadar FlexLine

Instruction manual 878 Panel Indicator

Enraf Servo Gauge 854 XTG

USER-MANUAL Tamson Cool Cube Immersion Cooler

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

Terminal Automation Solutions

Enraf Servo Gauge 854 ATG

Installation, operation & service manual. AlarmScout 961/962 line powered

OMC Ex interface unit. Manual. Version 1.2 August Author: Observator Instruments

Telemetry Communications Device. Installation Guide. Interface for the Emizon managed network. Issue 1: February 2008

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

KFP-CF Series Operation Manual

Proservo NMS5- / NMS7-

PRODUCT CONFORMITY CERTIFICATE

FIRERAY 5000 range USER GUIDE

RMS/RPX Reader. User Manual

INSTALLATION AND OPERATING MANUAL

Silicon Pyranometer GSM xx

Danfoss gas detection unit Type GD Heavy Duty

CentreVu Call Management System. Release 3 Version 8 Alarm Origination Manager

4590 Tank Side Monitor. Service Manual. WM550 Communication Protocol. Software Versionv2.03 SRM011FVAE0808

UDC100 Universal Digital Controller Specifications

R Series Remote Annunciators and Expander Installation and Operation Guide

OilMatic Pro / 230 V AC

Ax60+ Multi-Gas. Service Manual

SITRANS. Temperature transmitter Functional safety for SITRANS TW. Introduction. General safety instructions 2. Device-specific safety instructions

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

C-Bus 2 Channel Bus Coupler with Remote LED Facility Installation Instructions

Technical Sheet. Heat recovery appliance Renovent Excellent 180 (Plus) Renovent Excellent 180 1

FlameGard 5 UV/IR HART

Operating Instructions

TTSIM-1A. TraceTek Sensor Interface Module with Relay. Installation/Operation Instructions. Installation Items (not supplied) Tools Required.

FlameGard 5 MSIR HART

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

ENRAF SERVO LEVEL GAUGE

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

REPEATER FS5200R INSTRUCTION MANUAL

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

T3/E3 Fiber Optic Line Drivers

FAZ 3000-DCF DCF module

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

Model 17A00 Expansion Enclosure

Intelligent Security & Fire Ltd

Functional Safety Manual June pointek CLS500/LC500

PowerVent. Installation manual (GB) English. Store this document in a safe place UK

21-light Remote Annunciator. Owner s Manual

TTSIM-2 TRACETEK SENSOR INTERFACE MODULE WITH LCD AND RELAY INSTALLATION/OPERATION INSTRUCTIONS

Electronic Emergency Telegraph. TG-1 and TG-1A

SECTION AUTOMATIC TRANSFER SWITCHES

600 Range Dialer Installation Manual. Version 1.0

BSR Addressable Fire Detection control panel. Installation operation manual

USER-MANUAL TC6B-10B-20B-TB

/8 DIN Level Indicator

Instruction manual. Digital Radar Motion Detector with Infrared Remote Control MWD BF. FEIG ELECTRONIC GmbH Lange Straße Weilburg/Lahn

TEMPERATURE CONTROLLER (STANDARD MODEL)

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

IRIS Touch 400 & 600 Range Installation Manual. Honeywell Galaxy Range. Version 2.0

Cerabar S PMC71, PMP71, PMP75

Model GPT 3 Freeze Protection Thermostat

Remote NAC Power Supply D7038

BIOBASIC USER MANUAL. Models: 210, 310 & 410

Moxa Proactive Monitoring User s Manual

Operating Instructions

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

ERD97P21-U Receiver. Installation/ Operation Manual C939M-D (7/00)

Multi-Gas-Controller MGC2

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

T7100D Microelectronic Conventional Thermostat

OPERATION MANUAL MODEL LC2000 COPYRIGHT 2017 PNEUMERCATOR CO., INC EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY 11788

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

Druck DPI 705/DPI 705 IS Series

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

OilSET Installation and Operating Instructions. Oil Separator Alarm Device with SET/DM3AL sensor

Manual. Industrial Air Curtain Model IF. English. Version 1.1

Alarm system For oil-water separator

Declaration of conformity maintenance record. No Revised date Contents Reasons Approval

Wind Alarm Instrument

Demand ventilation 2.0

Test Lamp for 210 series flame detectors Non EX

CALL FOR TENDER - MUNICIPALITY OF THE DISTRICT OF CLARE LITTLE BROOK, N.S.

Safety Instructions MS 10B ALARM UNIT MS 10B ALARM UNIT. Used symbols. Always observe this information to prevent damage to the device

Freeze Protection Thermostat TRACON MODEL GPT 3 Installation and Operation Manual

Software Version 2.01 LEVEL MONITOR MODEL 220

RPM1600 Series Room Pressure Monitors

CDL 210. Operating manual. CO2 Logger. Best.-Nr

Instruktions manual. At skræmme fugle med laser!

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

Silicon UVAB Sensor E xxx

End To End Optical Beam Smoke Detector. Additional Information

WIO200 Water In Oil measuring instrument

Fire Control Panel FS5100

Original operating instructions Safety switch with guard locking AC901S AC902S

XGUARD-10/-5. LASER SCANNERS for industrial doors. User s Guide for product version 0600 and more

Model 3300 Technical Support and Installation Manual

USER-MANUAL TC

Transcription:

Instruction manual SPU II Hard alarm output contacts July 2009 Part no. 4416.223 Revision.1 Enraf B.V. P.O. Box 812 2600 AV Delft Netherlands Tel. : +31 15 2701 100 Fax : +31 15 2701 111 E-mail : enraf-nl@honeywell.com Website : www.honeywell.com/ps Instruction manual SPU II Hard alarm output contacts Page 1

Copyright 1999-2009 Enraf B.V. All rights reserved. Reproduction in any form without the prior consent of Enraf B.V. is not allowed. This manual is for information only. The contents, descriptions and specifications are subject to change without notice. Enraf B.V. accepts no responsibility for any errors that may appear in this manual. The warranty terms and conditions applicable in the country of purchase in respect to Enraf B.V. products are available from your supplier. Please retain them with your proof of purchase. Page 2

Preface Preface This manual is intended for technicians involved with the commissioning and service of the Honeywell Enraf Series 854 level gauges (models ATG & XTG) with the option hard alarm output contacts. For mechanical and electrical installation of the 854 ATG or 854 XTG, refer to the Installation guide 854 ATG and 854 XTG. Refer also to the list of related documents in the Appendix. A description preceding the technical procedures gives the technical information necessary to understand its functioning. It is recommended to read this description prior to performing any of the procedures. Safety and prevention of damage Refer to the Safety chapter in the Instruction manual of the 854 ATG or 854 XTG for the safety aspect of the instrument and for personal safety and the safety conventions. Legal aspects The information in this manual is the copyright property of Enraf B.V., the Netherlands. Enraf B.V. disclaims any responsibility for personal injury or damage to equipment caused by: Deviation from any of the prescribed procedures; Execution of activities that are not prescribed; Neglect of the general safety precautions for handling tools, use of electricity and microwave radiation. EC declaration of conformity This instrument is in conformity with the protection requirements of EC Council Directive 89/336/EEC. The CE conformity marking fulfils the provisions of EN 50081-2 Generic Emission Standard EN 50082-2 Generic Immunity Standard 73/23EEC Low Voltage Directive When installed, maintained and applied according to requirements as specified in this manual. Additional information Please do not hesitate to contact Honeywell Enraf or its representative if you require additional information. Instruction manual SPU II Hard alarm output contacts Page 3

Table of contents Table of contents Preface... 3 1 Introduction... 5 2 Commissioning... 6 2.1 Changing contact wiring from NC to NO... 6 2.2 Control items for relay output contacts... 7 3 Operation... 8 4 Trouble shooting... 9 Appendix Related documents... 10 Index... 11 Page 4

Introduction 1 Introduction The Honeywell Enraf series 854 ATG and XTG are servo based level gauges. These instruments are designed to accurately and reliably measure the product level and two additional interface levels in large storage tanks. One of the optional functions in both the level gauges is the hard alarm output contacts. The SPU II board (Servo Processor Unit) is then equipped with two alarm relays. The alarm relays can be used as level alarm output contacts or as digital output. The two relays are of the SPDT type and standard wired as normally closed (NC). If the normally open (NO) contact is required, the wiring at the SPU II board has to be changed from NC to NO (refer to figure 1.1). Figure 1.1 Relay contacts Operation of the relays Relays as hard alarm output contacts: Both relays can be linked to one of the four level alarms (HA, HH, LA, LL) which can be programmed in the 854 level gauge. For instance: relay 1 (RL1, contacts at terminals 5 and 6) operates on the high high level alarm setting (item HH). The linking is realized by software (item settings). The action on alarm condition (energized or de-energized) can also be obtained via a software (item setting). Relays as digital output: Another way of operating the relays is remote controlled. One item controls both relays. This has to be issued by the host or via the 847 PET (Portable Enraf Terminal). Instruction manual SPU II Hard alarm output contacts Page 5

Commissioning 2 Commissioning For information how to program items, refer to the instruction manual series 854 ATG level gauge, the instruction manual series 854 XTG level gauge or to the instruction manual 847 Portable Enraf Terminal. For connection of the external wiring circuit, refer to the installation guides of the series 854 ATG or 854 XTG. 2.1 Changing contact wiring from NC to NO Refer to figure 2.1. If the alarm contact wiring has to be changed into normally open, proceed as follows: 1 Switch off main power from the 854 level gauge; 2 Open the electronic compartment cover; 3 Remove PCB retaining screw and slide locking latch on the XPU(-2) board to the right and remove the XPU(-2) board; 4 On the SPU II board, change over the wiring at the at terminal strips CN1 and CN2 from NC to NO; 5 Re-install the XPU(-2) board, slide locking latch to the left and place PCB retaining screw; 6 Close the electronic compartment cover; 7 Apply mains power. Figure 2.1 Alarm relays on SPU II board SPU II in 854 ATG SPU II in 854 XTG CN1 - CO black wire, marked 5, to terminal 5 brown wire to terminal 5 CN1 - NO / NC black wire, marked 6, to terminal 6 brown wire to terminal 6 CN2 - CO black wire, marked 7, to terminal 7 grey wire to terminal 7 CN2 - NO / NC black wire, marked 8, to terminal 8 grey wire to terminal 8 Page 6

Commissioning 2.2 Control items for relay output contacts The following two items needs to be set (checked) for the proper operation of the alarm relays on the SPU II board. Item Name Description W1= Protection level 1 Enter protection level 1. RY= Relay alarm mode Six characters; default setting: HA - LA -. The six characters are represented as: A1, A2, M1, A3, A4, M2. Characters A1, A2 and M1 controls relay 1; characters A3, A4 and M2 controls relay 2. This item defines to which alarm the relays are linked. A1, A2 (A3, A4) Relay 1 (2) linked to: HH High high level alarm HA High level alarm LA Low level alarm LL Low low level alarm RC Relay set-up for remote control (via item RN) NM Relay not mounted M1 (M2) A Relay 1 (2) alarm mode: Relay will always be active if: alarm level is reached - Relay will only be active if: alarm level is reached and there is no test status active. W Relay will only be active if: alarm level is reached and there is no test status active and there is no water dip measurement active. RZ= Relay mode Four characters; default setting: DEDE. The four characters are represented as: B1, B2, B3, B4. Characters B1 and B2 operates on relay 1; characters B3, and B4 operates on relay 2. This item defines operation modes of the relays. B1 (B3) E D B2 (B4) E D Relay 1 (2) operation mode: normally energized normally de-energized Relay 1 (2) fail mode: energize relay on gauge fail de-energize relay on gauge fail EX Exit Exit protection level 1. Instruction manual SPU II Hard alarm output contacts Page 7

Operation 3 Operation The two alarm relays can be remotely controlled by the host or by means of the 847 PET (Portable Enraf Terminal). Item RN (relay command) controls both alarm relays. Item Name Description RN= Relay command Eight characters. The eight characters are represented as: C1, T1, T2, T3, C2, T4, T5, T6. C1, T1, T2 and T3 for relay 1; C2, T4, T5 and T6 for relay 2. Date item RN is used for remote control of the relays. C1 (C2) Relay 1 (2) command: A activate relay D de-activate relay K acknowledge alarm - don t change T1, T2, T3 (T4, T5, T6) Relay 1 (2) time data field: 000-999 Time setting in seconds for activate command only. If the time field is set to 000, the relay is continuously activated. For other commands, dummy values must be specified (e.g. RN=K000-000). Note: The acknowledge command can only be given if the relays are set-up for level alarm operation; the other command can only be given as the relays set-up for remote control (refer to item RY). The actual relay status can be checked by data item RX (relay status): Item Name Description RX Relay status Two characters. The first character (B1) is related to relay 1; the second character (B2) is related to relay 2. B1 (B2) Status of relay 1 (2) K acknowledge alarm A activated relay D deactivated relay T time setting is active F relay fail N relay is not mounted (and not checked) Page 8

Trouble shooting 4 Trouble shooting The 854 ATG and 854 XTG are self diagnostic instruments. Detected errors will be shown as status information on the display (854 ATG only), or can be requested as an item by the PET (or host). Item ES (error SPU request) contains the SPU II error code. The following two SPU error codes refer to the operation of the alarm relays: 0851 Relay 1 fail Relay 1 has not been mounted (check item RY), or relay 1 fails to operate (check with item RX; change relay 1). 0852 Relay 2 fail Relay 2 has not been mounted (check item RY), or relay 2 fails to operate (check with item RX; change relay 2). Instruction manual SPU II Hard alarm output contacts Page 9

Appendix Appendix Related documents Title Part No. Installation guide 854 ATG Level Gauge 4416.225 Installation guide 854 XTG Level Gauge 4416.276 Instruction manual series 854 ATG level gauge 4416.220 Instruction manual series 854 XTG level gauge 4416.275 Instruction manual 847 Portable Enraf Terminal 4416.210 Page 10

Index Index Error SPU request... 9 ES... 9 NC... 5, 6 NO... 5, 6 Normally closed... 5, 6 Normally open... 5, 6 Relay alarm mode... 7 Relay command... 8 Relay mode... 7 Relay status... 8 RN... 8 RX... 8, 9 RY... 7, 9 RZ... 7 Safety... 3 SPU II board... 6 Instruction manual SPU II Hard alarm output contacts Page 11

Page 12 Notes