UL Systems. UL intelligent addressable systems Product Name

Similar documents
Cooper Fire Systems. UL Listed Range

ULCF3000 ULCF3000RM INSTALLATION MANUAL. Conforms to UL864 9th Edition. Assessed to ISO 9001:2008

Addressable Fire Alarm Control Panel

Sita200plus. 200detectors. Single loop analogue addressable System

C E R T I F I C AT LPCB I O N B O A R D P R E V E N T L O S S. Cooper Fire Systems

Conventional systems Product Name

EFBW series - BiWire Ultra control panel

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

FIRE ALARM SOLUTIONS THAT FIT YOUR NEEDS

GE Security EST Fire & Life Safety. Sophisticated io-series. Intelligent Life Safety Systems for small to mid-size buildings

System 800 Addressable Fire Detection & Alarm System

Conventional Fire Detection

MINERVA MZX125 Digital Addressable Fire Detection System

ID50series. intelligent fire alarm panels

good things in small packages

Intelligent 2 & 4 Loop Fire Alarm Control Panels

The CWSI System CALL WITH QUESTIONS. RELY ON OUR KNOWLEDGE. DEPEND ON OUR EXPERIENCE. (800)

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Fire Product Catalog

Multiple Input and Output Modules

Apollo Accreditation. Need further information? Visit

MINERVA MZX125. Digital Addressable Fire Detection System

Wireless Fire & Security Solutions. Fire Product Showcase

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Intelligent Single Loop Fire Alarm Control Panel

Addressable and Conventional Fire Protection

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Protec. Protec Algo-Tec TM 6100 Interactive Digital Addressable Fire Control System. Fire Detection - Addressable

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Innovative protection that combines power and flexibility

Fire detection and alarm

four Vigilon Compact Analogue Addressable Fire Detection & Alarm System 4/1

Intelligent Security & Fire Ltd

D7024 Fire Alarm Control Panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

intelligent fire alarm ID60series panels

ELECTRONIC SOUNDER STROBE Model : AVD-C407

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

Touch Screen 1 loop Addressable Fire Alarm Panel

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

1. POWERPATH Operation

Specification/ Data Sheet

MINERVA. Marine. Fire Detection. MX T2000 Panel Range. Features: MINERVA Marine Panel Range

MINERVA MX. 800 Series Ancillary Equipment

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Solution F2. Fire Alarm Control Panels one step ahead.

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Wireless Fire & Security Solutions. Fire Product Showcase

GE Security Vigilant Fire & Life Safety. Easy. V-Series Intelligent Life Safety Systems

4007ES Fire Control Panels

HILLS RELIANCE 4 ALARM SYSTEM 4 zone panel

FIRE DETECTION SYSTEMS. Product Guide

ADR Analog Addressable Fire Alarm Control Panel. Technical Manual. Control Panels. 3000En. En pdf

Intelligent addressable fire alarm control panel

Industries. As a premier global manufacturing company, we believe that great brands are

SAFEPATH SAFEPATH. Emergency communications system

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

IGD.CO.UK

FIRE DETECTION SYSTEMS. Product Guide

WORLD CLASS SOLUTIONS TO A UNIVERSAL CHALLENGE EST LIFE SAFETY PRODUCTS DETECTORS AND MODULES ... EDWARDS SYSTEMS TECHNOLOGY

Protec. Protec Algo-Tec TM 6500 Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network. Fire Detection - Addressable

Xenex Conventional Fire Detection & Alarm System

Installation, Operating and Maintenance Manual

SMALL SCALE SOLUTIONS

Wireless Fire Solutions

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

intelligent solutions

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

Protec. Protec Algo-Tec TM 6500 Open Protocol Interactive Digital Addressable Fire Control System with Algo-Tec 6600 Bridging Network

Conventional Fire Alarm Systems. ACCLAIM SERIES 10 Conventional Fire Alarm System ACCLAIM SERIES 10.

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

Analogue addressable devices

The new detector from Rafiki

SECTION FIRE ALARM SYSTEMS

Consultant Specification AGILE Wireless Fire Detection System

Scope. Warning sounders except specific requirements. Intercom Systems for Emergency Purposes. Sound Systems for Emergency Purposes

RELEASE DEVICE CONTROLS

The supplier and installer of the system should be approved by the local civil defence authority.

Intelligent Analog/Addressable Fire Alarm/Voice Integration Systems. IntelliKnight TM Series

ORENA BRAND CONVENTIONAL (ORENA Brand) CE

OH110, OP110, HI110. Automatic Fire Detectors. Automatic Fire Detector For collective and conventional detector lines

The EN54 Part 2 and 4 Fire System

MODEL B2 INSTALLATION MANUAL

ID3000 intelligent. fire alarm panel

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

AL600ULADA. NAC Power Extender. Installation Guide

Commercial and Light Industrial Fire Alarm Control Panel

Evolution Analogue Addressable Fire System

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Control Panels. Control Panels for Commercial Applications. Control panels provide the central processing

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

INDEX 1- Introduction The Control Pane...7l 4.1- The Control Panel 1 and 2 Loops The Control Panel 4 and 8 Loops...

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Transcription:

Product Name UL Systems Underwriters Laboratories Inc. (UL) is an independent product safety certification organisation, established in 1894, to develop standards and test procedures for products, materials, components, assemblies, tools and equipment. Chiefly dealing with product safety it also evaluates and certifies the efficiency of a company s business processes through its magnificent system registration programs. Since the launch of our UL Listed fire product range, several prestigious projects worldwide have been supplied including yatt Resort and Spa, Shangri-la at the Fort and Times Square projects in South East Asia and several major projects in the Middle East including a major projects within the prestigious Riyadh Financial District in the Kingdom of Saudi Arabia. The Eaton UL range is designed to provide a solution for all sizes of project, from the simple small stand alone system to the large multi panel networked system with PA/VA and BMS integration. 42 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015

Contents Contents UL listed fire systems range Panels ULCF3000 series panels 44 Devices Addressable sensors 46 Conventional detectors 48 orns and strobes 50 Pull stations 52 Interfaces 54 Micro interfaces 55 FIRE ALARM EQUIPMENT EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015 43

ULCF3000 series ULCF3000 series UL listed control panels ULCF3000RM (wall mount red metal) ULCF3000 (wall mount graphite) The ULCF3000 series panels are UL listed, high specification, wall or rack mounted fire panels. Combining sophisticated functionality with simple operation and aesthetically pleasing design, the panels are available in a number of loop configurations. Each panel is networkable with up to 126 other Eaton UL fire panels. The control panel has the ability to support complex cause and effect programming. A wide range of user controllable functions make the system ideal for a diverse range of projects, from industrial applications through to large multi-site commercial developments. Benefits Soft addressing Large versatile touchscreen user interface Integral printer (optional) Integral battery and power supply 2 x 12Ah batteries included Flexible distributed network capability Full range of compatible devices 4 notification appliance circuits (NACs) outputs 2 or 4 class A style 7 SLC loops PAS (Positive Alarm Sequence) FIRE ALARM EQUIPMENT 44 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015

ULCF3000 series D2 D2 (mm) (mm) D1 (mm) D2 (mm) ULCF3000 397 497 75 130 ULCF3000RM 398 505 48 118 Compatible repeater panels The ULCF3000 has both a standard and a touchscreen repeater panel available. Ideal for larger sites, the repeater allows you to display the system information from multiple locations. Features ULCF3000PRG ULCTPR3000 Active or passive option No programming required * Multi language capability Allows networking with other Eaton fire panels Integral power supply *Except local text information Catalogue numbers 2 loop panel ULCF30002G 4 loop panel ULCF30004G 2 loop panel, integral printer ULCF30002GP 4 loop panel, integral printer ULCF30004GP 2 loop panel, network card ULCF30002GNC 4 loop panel, network card ULCF30004GNC 2 loop panel, integral printer, network card ULCF30002GPNC 4 loop panel, integral printer, network card ULCF30004GPNC 2 loop panel, red metal box ULCF30002GRM 4 loop panel, red metal box ULCF30004GRM 2 loop panel, integral printer, red metal box ULCF30002GPRM 4 loop panel, integral printer, red metal box ULCF30004GPRM 2 loop panel, network card, red metal box ULCF30002GNCRM 4 loop panel, network card, red metal box ULCF30004GNCRM 2 loop panel, integral printer, network card, red metal box 4 loop panel, integral printer, network card, red metal box Rack mounted 2 loop panel Rack mounted 4 loop panel Rack mounted 2 loop panel c/w network card Rack mounted 4 loop panel c/w network card Loop connected repeater panel Touchscreen network repeater panel ULCF30002GPNCRM ULCF30004GPNCRM ULR3000L2 ULR3000L4 ULR3000L2NC ULR3000L4NC ULCF3000PRG ULCTPR3000 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015 45

Devices - addressable sensors Sensors Our UL range has multiple options for intelligent addressable sensors. All sensors are designed for optimum functionality in mid-large sized builds. They are all soft addressed and have integral short circuit isolators. Addressable sensor base UCAB300 Optical smoke sensor ULCAP320 Photo-thermal sensor ULCAPT340 eat sensor ULCA330 Specifically designed for use with all of our UL addressable sensors, the UCAB base will be used in all builds. Suitable for most applications. Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. Responds quickly to fast clean burning fires. Maintains the advantage of optical sensors when detecting smouldering fires. Environments where the ambient conditions might cause false alarms with smoke detectors. Examples include areas with high levels of dust or fumes. Sensor detail Addressable base detail 46 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015

Devices - addressable sensors Performance eat Class ULCAP320 ULCAPT340 ULCA330 eat element rating N/A 135 F ROR + Fixed 135 F, Fixed 135, Fixed 194 F eat detector spacing N/A 50ft (heat alone operation) 50ft eat class N/A A2S A2R Dia D1 D2 Diameter (mm) (incl base) Depth (mm) (excl base) Depth (mm) (incl base) Optical 104 33 45 Photo-thermal 104 43 55 eat 104 43 55 Catalogue numbers Optical smoke sensor Photo-thermal sensor eat sensor Addressable sensor base ULCAP320 ULCAPT340 ULCA330 UCAB300 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015 47

Devices - conventional detectors Detectors Our UL range has multiple options for conventional detectors. All detectors have a removable detector chamber and drift compensation. The range of detectors for different applications allow for all build requirements to be met. As there is no UL certified conventional panel a ULMIU872 micro interface (page 55) is required in conjunction with a UL intelligent addressable panel to use conventional detectors. Optical smoke detector UCPD-2 Photo-thermal detector UCPT-2 Fixed heat detector (135 F) UCT-2 Additional heat detector options Suitable for most applications. Fastest response to slow burning or smouldering fires which give rise to large visible smoke particles. Responds quickly to fast clean burning fires. Maintains the advantage of optical sensors when detecting smouldering fires. Environments where the ambient conditions might cause false alarms with smoke detectors. Examples include areas with high levels of dust or fumes. UCTI-2: Fixed heat, 194 F detector UCR-2: Rate of rise & fixed heat 135 F UCRI-2: Rate of rise & fixed heat 194 F Performance eat class UCPD-2 UCPT-2 UCT-2 UCTI-2 UCR-2 UCRI-2 eat element rating N/A 135 F 135 F 194 F 135 F 194 F eat detector spacing N/A 50ft (heat alone operation) 50ft 50ft 50ft 50ft Mounting position Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas Ceiling in open areas 48 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015

Devices - conventional detectors Conventional detector base CB2E The CB2E has been specifically designed for compatibility with our UL range of conventional detectors. It can be be used in all builds with conventional detectors. Catalogue numbers Dia D1 D2 2 wire detector, optical UCPD-2 2 wire detector, opto-heat UCPT-2 2 wire detector, fixed heat 135 f UCT-2 2 wire detector, fixed heat 194 f UCTI-2 Diameter (mm) (incl base) Depth (mm) (incl base) Optical 104 45 33 Photo-thermal 104 55 43 eat 104 55 43 Depth (mm) (excl base) 2 wire detector, rate of rise and fixed heat 135 f 2 wire detector, rate of rise and fixed heat 194 f Standard detector base UCR-2 UCRI-2 CB2E EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015 49

Devices - horns and strobes orns and strobes Our UL range incorporates a variety of audio and visual notification devices. Each device has up to 48% savings in current draw compared to similar products. The whole range is easy to install and has voltage test points for quick troubleshooting and easy spot checking, saving time on both installation and maintenance. all mount horn NR Ceiling mount horn NC all mount horn strobe/synchronised strobe SR/STR Ceiling mount horn strobe/synchronised strobe SC/STC The horns are ideal for retrofit jobs, limited space environments and pre-existing wire configurations. The horns are ideal for retrofit jobs, limited space environments and pre-existing wire configurations. ith the range of settings for both audio and visual purposes, these products are effectively 9 models in 1 appliance. ith this functionality, and both ceiling and wall mount options available, it will meet almost any build requirements. The synchronised option enhances both the sound and light output by keeping the outputs of multiple devices in sync. D Dia D (mm) (mm) D (mm) Diameter (mm) Depth (mm) all mount horn NR 133 116 56 Ceiling mount horn NC 166 34 all mount horn strobe/ synchronised strobe SR/STR 131 131 110 Ceiling mount horn/ synchronised strobe SC/STC 166 34 50 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015

Devices - horns and strobes all mount outdoor synchronised strobe RSSP-2475-FR Ceiling mount outdoor synchronised strobe RSSP-2475C-F The outdoor synchronised strobes are UL certified to meet adverse weather conditions. They are perfect for builds where outdoor indication is required. These units use a universal, common mounting base making them ideal for retrofit jobs, limited space environments and pre-existing wire configurations. Catalogue Numbers D all mount horn NR Ceiling mount horn NC all mount horn strobe SR (mm) (mm) D (mm) RSSP* 131 131 110 *Both wall mount and ceiling mount variants Ceiling mount horn strobe all mount synchronised strobe Ceiling mounted synchronised strobe all mount outdoor synchronised strobe Ceiling mount outdoor synchronised strobe Exposed conduit, surface mount back box (RED) Concealed conduit surface mount back box (RED) SC STR STC RSSP-2475-FR RSSP-2475C-F PSBB PSBB + PKIT EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015 51

Devices - pull stations Pull stations The addressable pull stations are constructed of high quality, die cast metal for long lasting performance. The range consists of the UL listed MPS range of pull stations and the UL listed fast response input initiating module (ULMCIM-C). Single action addressable pull station UMPS-100/ UMPS-100P Single action conventional pull station SG42BK2 Indoor/weatherproof pull station for use with addressable systems (UMPS-100/UMPS-100P). A dual action model is also available (UMPS-200, not shown), where the push bar rotates inward allowing the pull handle to be grasped in a one handed motion. Cost effective conventional version of the single action pull station, must be used in conjunction with ULMIU872. Back box ordered seperately. Pull station detail Catalogue numbers D Single action pull station, supplied with back box (addressable) eatherpoof single action pull station Double action pull station UMPS-100 UMPS-100P UMPS-200 Micro zone monitor unit Micro single channel input unit (recognised as callpoint) Conventional single action pull station (back box ordered seperately) ULMIU872 ULMCIM-C SG42BK2 (mm) (mm) D (mm) 118 80 80 Conventional double action pull station (back box ordered seperately) Back box for conventional, surface mounting Back box for conventional, weatherproof SG42BK1 SGB32S SGB-32C 52 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015

Product Name EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015 53

Devices - interfaces Interfaces e supply an extensive range of interfaces to support our UL control panels. Interfaces allow for a wide variety of installations to be simplified without the use of specialist or customised equipment. For assistance deciding which interfaces will benefit you the most, contact our technical support team; techsupport@cooperfire.com 4 ay Sounder Controller Unit ULCSC354 Zone monitor unit ULCZMU352 Shop monitor unit ULCSUM355 Spur isolator unit ULCSI350 The unit connects a zone of suitable conventional detectors and a separate zone of conventional callpoints (if required) to an addressable panel. It allows for easier connection to existing conventional detection zones, as long the devices used are compatible. The unit connects a zone of suitable conventional detectors and a separate zone of conventional callpoints (if required) to an addressable panel. It allows for easier connection to existing conventional detection zones, as long the devices used are compatible. The shop monitor unit is designed to allow small units with conventional fire systems to be fully integrated with a main intelligent addressable fire system. It is ideal for connecting individual shop units into a main shopping centre system. The spur isolator unit enables a spur of intelligent addressable devices to be connected to a main analogue loop. This simplifies the installation of remote parts of buildings or system extensions. 3 channel I/O unit ULCIO351 230V ac relay unit ULCMIO353 D D The 3 channel input/output unit enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The inputs are fully monitored for open and short circuits. Enables simple interfacing between the fire system and other equipment such as nurse call systems or access control systems. The ability of the output unit to switch mains also makes the unit ideal for plant control or mains powered door holders. The input is monitored for open and short circuits so can be used for fire input applications such as monitoring sprinkler flow switches. (mm) (mm) D (mm) Interface units 129 180 60 4 way sounder controller unit 300 300 74 54 EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015

Devices - micro interfaces Micro interfaces hilst our standard UL interfaces are designed to be installed in the position required on the loop, our range of micro interfaces can sit within a panels enclosure. Micro single channel output units ULMCOM/ULMCOM-S Micro single channel input units ULMCIM/ULMCIM-C Micro zone monitor unit ULMIU872 D The Micro Single Channel Output Unit (ULMCOM) is suitable for switching low voltage (24V dc at 1A maximum), via a set of non latching relay contacts. It is also suitable for switching VAC control circuits, plant shutdown control circuits, fire door closure etc. The ULMCOM-S is identified by the panel as a sounder. The Micro Single Channel Input Unit (ULMCIM) is suitable for monitoring a set of normally open, volt free contacts such as sprinkler system flow switches and auxiliary panel fire/fault signals. Other examples include non-fire input signals such as flow valve open contacts, generator start up, fire door closed etc. The ULMCIM-C is identified by the panel as a call point and is designed for use with pull stations. The Micro Zone Monitor Unit (ULMIU872) is suitable for monitoring a zone of up to 20 UL approved conventional detectors. (mm) (mm) D (mm) 65 35 18.5 Please be aware, we offer an enclosure for our micro interfaces, see p35. Catalogue numbers 4 way sounder controller unit ULCSC355 Zone monitor unit ULCZMU352 Shop monitor unit ULCSUM355 Spur isolator unit ULCSI350 3 Channel input/output unit resets on reset ULCIO351 3 Channel input/output unit rests on silence alarms ULCIO351S 120V/230V ac relay u.nit ULCMIO353 Micro zone monitor unit Micro single channel output unit (recognised as output unit) Micro single channel output unit (recognised as sounder) Micro single channel input unit (recognised as input unit) Micro single channel input unit (recognised as callpoint) Mini module box unit (empty box) ULMIU872 ULMCOM ULMCOM-S ULMCIM ULMCIM-C ULBU EATON - FIRE AND VOICE ALARM SYSTEMS CF-CC2556 January 2015 55