WARNING VL-220CZGV-E. 1. Safety Precautions LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) Contents. Eng-1. English

Similar documents
MA Remote Controller PAR-31MAA

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

GUG-01SL-E GUG-02SL-E GUG-03SL-E

GUG-01SL-E GUG-02SL-E GUG-03SL-E

CITY MULTI Control System and Mitsubishi Air Conditioners Wireless Remote Controller PAR-SL100A-E

HC8301. Lossnay. Models: LGH-150RVXT-E LGH-200RVXT-E LGH-250RVXT-E. Operating Instructions

OPERATING MANUAL. AIR CONDITIONER Duct Type. Indoor Unit ARTG36LH ARTG45LH ARTG54LH ARTG60LH PART NO KEEP THIS MANUAL FOR FUTURE REFERENCE

USER S MANUAL. Wired Remote Controller MWR-WS00. System Air Conditioner ESPAÑOL FRANÇAIS ITALIANO PORTUGUÊS DEUTSCH EΛΛHNIKA RUSSIAN

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

WIRED REMOTE CONTROLLER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Residential-Use Lossnay

OPERATING MANUAL AIR CONDITIONER DUCT TYPE. ART Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

AIR CONDITIONER OPERATING MANUAL. Duct type. Indoor Unit ARTG45LDTA ARTG54LDTA ARTG60LDTA KEEP THIS MANUAL FOR FUTURE REFERENCE. PART No.

Installation/Instruction Manual

Owner s Manual VN-M150HE VN-M250HE VN-M350HE VN-M500HE VN-M650HE VN-M800HE VN-M1000HE VN-M1500HE VN-M2000HE. Air to Air Heat Exchanger

WIRED REMOTE CONTROLLER

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

R410A. AIR CONDITIONER DUCT TYPE / ART Series OPERATING MANUAL. REFRIGERANT This Air Conditioner contains and operates with refrigerant R410A.

KSD-35 DR11 KUE-35 DVN11

Installation Instructions

SYSTEM Inverter Air Conditioners

OPERATION MANUAL. System Inverter Air Conditioners FXNQ20A2VEB FXNQ25A2VEB FXNQ32A2VEB FXNQ40A2VEB FXNQ50A2VEB FXNQ63A2VEB

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

OPERATING MANUAL UTY-RNNYM P/N English

Operating Instructions

HEAT & COOL MODEL (REVERSE CYCLE)

USER S MANUAL AQV09J Series AQV12J Series AQV18J Series AQV24J Series

JT-SB116JH-G-NA JT-SB116JH-W-NA

User Manual HEAT RECOVERY VENTILATORS 1000 HE HE HE HE HE HE COMPACT 5585 COMPACT READ AND SAVE THESE INSTRUCTIONS.

Operation Manual - PC-ARF - P IMPORTANT:

DAIKIN ROOM AIR CONDITIONER. Operation Manual

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

WIRED REMOTE CONTROLLER

Owner s Manual. Indoor Unit MMK-AP0073H2UL MMK-AP0093H2UL MMK-AP0123H2UL MMK-AP0153H2UL MMK-AP0183H2UL MMK-AP0243H2UL AIR CONDITIONER (MULTI TYPE)

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

Air-Conditioners. Indoor unit PSA-RP KA OPERATION MANUAL. English

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

CONTENTS SAFETY PRECAUTIONS. En-1 DANGER! CAUTION!

Operating Instructions

250mm dia straight pipe length SP4 SP3. Air volume

SPLIT TYPE

CASSETTE TYPE. AUT Series FUJITSU GENERAL LIMITED AIR CONDITIONER OPERATING MANUAL P/N KEEP THIS MANUAL FOR FUTURE REFERENCE AM PM

SU MO TU WE TH FR SA AM PM

Service Manual This Service Manual is written for the after sail service department, especially for the fix and maintenance workers.

Owner s Manual Super-Slim Four-Way Cassette

Installation and user manual

Operating Instructions High-spec Wired Remote Controller

READ AND SAVE THESE INSTRUCTIONS

Owner's Manual TABLE OF CONTENTS

Fujitsu OPERATING MANUAL Air Conditioner DUCT TYPE

53 KNL / 53 QNL OWNER S MANUAL

Ducted air conditioner Operating Manual

Compact Cassette Type

Inverter Split-type Room Air Conditioner

30-pint Dehumidifier User Guide

Dehumidifier. Instruction Manual. Model DH-320/A

ULTRA LOW TEMPERATURE FREEZER. User Manual

Dehumidifier. Instruction Manual

Owner s Manual AIR CONDITIONER (MULTI TYPE) Outdoor Unit. Model name: <Heat Pump Model> For commercial use MCY-MAP0401HT MCY-MAP0501HT MCY-MAP0601HT

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Owner s Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

OWNER'S MANUAL R-410A Duct Free Split System Air Conditioner and Heat Pump

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

MULTI-SPLIT SYSTEM AIR CONDITIONER / HEAT PUMP. YN-M Series. Inverter++ Models. Two, Three, Four, and Five Zones (Dual, Triple, Quad, and Quint Multi)

AIR CONDITIONER OWNER S MANUAL. Please read this manual carefully before operating your set and retain it for future reference.

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

HEAT RECOVERY VENTILATORS MODELS HRV 90H-V ECM, 90H-V

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Coway Air Purifier AP-1008BH/CH

Owner s Manual CS

PORTABLE AIR CONDITIONER

GUF-100RDH3. Model name The picture is shown GUF-50RDH3. Notice: The term of validity is for a year from the issued date.

AIR CONDITIONER (MULTI TYPE) Owner s Manual. Outdoor Unit. Model name: Heat Pump Model MCY-MHP0406HT-E MCY-MHP0506HT-E. English. For commercial use

User manual AG-WT10. Indoor unit air/air heat pump UHB GB

VIGÖR HRV PLUS AND VIGÖR ERV

USER S MANUAL AQV09V A Series AQV12V A Series AQV18V A Series AQV24V A Series

Coway Air Purifier AP-1008DH

Bosch Split-Type Ductless Air Conditioner / Heat Pump

IMPORTANT INSTRUCTIONS READ & SAVE

NEXXOS INVERTER USER MANUAL

OPERATION MANUAL. Air Conditioners FXAQ20PV1 FXAQ25PV1 FXAQ32PV1 FXAQ40PV1 FXAQ50PV1 FXAQ63PV1. MODELS Wall-mounted type. English. Deutsch.

Operating Instructions Air Conditioner

Air Conditioner. user manual. imagine the possibilities. Wired Remote Control MWR-WH02. This manual is made with 100% recycled paper.

Reverse Cycle Split System Air Conditioner

OPERATING MANUAL AIR CONDITIONER CASSETTE TYPE. AUT Series KEEP THIS MANUAL FOR FUTURE REFERENCE FUJITSU GENERAL LIMITED P/N

AIR CONDITIONER OPERATING MANUAL. Cassette type. Indoor Unit AUTG30KRLA AUTG36KRLA AUTG45KRLA AUTG54KRLA. PART No

Operation manual. Split system air conditioners FDXM25F3V1B FDXM35F3V1B FDXM50F3V1B FDXM60F3V1B. Operation manual Split system air conditioners

Monsoon RS400. Operating Instructions Mode d emploi Bedienungsanleitung Manual de Instrucciones Istruzioni per il funzionamento Gebruiksaanwijzing

HEAT RECOVERY VENTILATORS MODELS AVS HRV EKO 1.5, AVS CONSTRUCTO 1.5V, NOVOFIT 1.0 AND ENERGY RECOVERY VENTILATOR MODEL AVS ERV EKO 1.

Instruction Manual. Bottle Cooler. Models HBC-50 (-S) HBC-65 (-S) HBC-80 (-S) HBC-95 (-S) hoshizakiamerica.com. Issued: Revised:

Indoor Unit (2 Series)

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

PEH-8,10WYB. Air-Conditioners INDOOR UNIT. For use with R410A OPERATION MANUAL

Using the Remote Control Unit

SYSTEM Inverter Air Conditioners

Transcription:

English LOSSNAY HEAT RECOVERY VENTILATOR (RESIDENTIAL USE) MODEL VL-220CZGV-E Instruction Manual For user Contents 1. Safety Precautions 1-2 2. Features 2 3. Preparations Before Use 3 4. Names and Functions of Parts 3 5. How to Use 4-12 6. Maintenance 13-14 7. Troubleshooting 15 16 9. After-Sales Service 16 Do not attempt to install the product by yourself. (Safety and proper functions of the product may not be assured.) to use it correctly and safely. 1. Safety Precautions The following symbols denote the type and degree of danger resulting from incorrect handling. Incorrect handling of the product may result in serious injury or death. WARNING Prohibited No water exposure No disassembly Cannot be installed in a bathroom Do not turn on or off the remote controller when corrosive gas has leaked. gas to explode. Do not use the product in hot places, in the direct sunlight and in smoky places. Refrain from immersing in water or splashing the product with water. Do not modify or disassemble the product using tools. Make sure that the product is not installed at a bathroom or other humid location. Failure to heed this warning may result in Make sure that the remote controller is not installed in a bathroom. Failure to heed this warning may result in Make sure that the product is grounded. About installing a ground, contact your dealer or an electrical contractor. Follow instructions Use 220 to 240 V AC power. damage to the circuit boards. Make sure that the outside air intake vent is located at a position where combustion gas or other similar exhaust is not sucked in. Be sure to turn off the remote controller and the circuit breaker on the power board before cleaning and maintenance. If an abnormality occurs (for example, when you smell burning), stop operation, and turn off the circuit breaker on the power board. If an abnormality or malfunction occurs, immediately stop use of the product. Contact an electrical contractor to work electrical wiring. Make sure that the product is installed at a horizontal. Make sure that an outdoor hood, that makes it less likely for rain water, snow or small animals (e.g. bats) from entering, is installed at the ends of supply air and exhaust ducts. If the product will not be operated for a long period of time, be sure to turn off the circuit breaker on the power board. Eng-1

1. Safety Precautions (continued) Prohibited Follow instructions CAUTION Do not use the Lossnay unit at locations where toxic gas or gas containing corrosive components such as acids, alkaline, organic solvents, or paints is generated. Failure to heed this warning may result in malfunction. Do not place objects under the product. Dew condensation water may drip. During cleaning and maintenance, do not climb on an unstable stand. Injury may result if you tumble down. Make sure that drain piping is installed at the discharge outlet. Wear gloves during cleaning and maintenance. Failure to heed this warning may result in injury. that has built up inside sometimes drips. So, them with both hands so that they are not tilted. Securely install the parts after cleaning and maintenance. Injury may result if the parts should fall. Incorrect handling of the product may result in injury or damage to property or household effects. Follow instructions Do not spray the Lossnay unit, wall switch, or supply air/ exhaust grille with a insecticide, hair, or cleaning spray. Failure to heed this warning may deform or damage parts. This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. (This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.) Requests on Use malfunction. Wipe off any water droplets. not a malfunction. Wipe off any water droplets. parts. This is not a malfunction. Wipe off any water droplets. sometimes sense from the air vent. - Operating noise may be a cause of concern directly underneath the product. 2. Features What is the LOSSNAY HEAT RECOVERY VENTILATOR? Effective ventilation routes can be achieved in the entire house by the supply air vent and the exhaust vent being installed at locations away from each other depending on the duct connection method. During heat exchanger operation reusing (heat collection) the warmth or coolness of the room which is discarded during ventilation. ensure energy savings. During By-pass operation * This function can be used only when the optional motorized damper (P-133DUE-E) is used. Eng-2

3. Preparations Before Use Receive an explanation about operation procedures and the correct method of use to ensure safe operation. been temporarily stopped.) - During cleaning and maintenance may form on the product and other parts. So, switch the operation mode to temporarily stop operation, and open the windows. Inspection opening... It is required for maintenance on the product. This product is installed in house attics. Grills... (Example) English Remote controller 4. Names and Functions of Parts It holds the exhaust air from clogging. Release it to remove the locations) from the outside air that is Release it to remove the locations) removed Drain pan (supply air side) It holds dew condensation water that occurs inside the heat between the supply air and the exhaust. Drain outlet It is for discharging dew condensation water that has built up in the drain pan to outside the room. Eng-3

5. How to Use When using PZ-61DR-E Power supply System example Remote controller (System components) Operation Operate the product by the remote controller. Controller interface 5 6 6 ON/OFF lamp This lamp lights up in green while the unit is in starting up or when there is an error. The functions of the function buttons change depending on the screen. Refer to the button function guide that appears at the bottom of the LCD for the functions they serve on a given screen. When the system is centrally controlled, the button function guide that corresponds to the locked button will not appear. Function buttons 1 ON/OFF button 2 SELECT button Press to save the setting. 3 RETURN button Press to return to the previous screen. 4 MENU button Press to bring up the Main menu. 5 Backlit LCD Operation settings will appear. 2 3 1 4 7 8 9 0 Main display Lossnay Fan Auto Mode 12:00 Sun 7 8 9 0 7 8 9 0 Function guide Main menu Main Main menu 1/2 Timer Weekly timer Restriction Filter information Error information Main display:return button 7 Function button F1 Main menu: Press to move the cursor down. 8 Function button F2 Main display: Press to change the fan speed. Main menu: Press to move the cursor up. 9 Function button F3 Main display: Press to change the ventilation mode*. Main menu: Press to go to the previous page. 0 Function button F4 Main menu: Press to go to the next page. of time depending on the screen. * The mode can be switched only when the optional motorized damper (P-133DUE-E) is used. button) Eng-4

5. How to Use (continued) Display * All icons are displayed for explanation. English 798 1 Lossnay 12:00 Sun 2 6 5 Auto Fan Mode 3 4 0 4* 1 Remote controller name 2 Clock (See the Installation Manual.) Current time appears here. 3 Fan speed Fan speed setting appears here. 4 Button function guide Functions of the corresponding buttons appear here. * The mode appears only when the optional motorized damper (P-133DUE-E) is used. 5 Indicates when filter needs maintenance. 6 7 function is enabled. 8 9 Appears when performing operation to protect the equipment. 0 Ventilation mode Indicates the ventilation mode setting. * The mode appears only when the optional motorized damper (P-133DUE-E) is used. Eng-5

5. How to Use (continued) ON will start. OFF Fan speed Lossnay 12:00 Sun Press the F2 button to go through the fan speeds in the following order. Auto Fan Mode not displayed. Ventilation mode Lossnay 12:00 Sun Press the F3 button to go through the Ventilation mode in the following order. Auto Fan Mode * The mode can be switched only when the optional motorized damper (P-133DUE-E) is used. Display Function The mode is switched automatically between the heat exchanger mode and by-pass mode. the by-pass mode is used. Details on how to change the temperature mode. When the outdoor air temperature decreases to 8 mode is switched automatically to heat exchanger mode even if Ventilation mode was set. The indication on the remote controller remains as by-pass mode. (Freeze prevention) Eng-6

5. How to Use (continued) English Button operation 1 Main Main menu Initial setting Service Main display: 2/2 Clock setting is required before making the following settings. 2 Initial setting menu 1/2 Main/Sub Clock Main display Contrast Display details Main menu: Clock 3 yyyy / mm/ dd hh: mm 2014 / 01 / 01 00: 00 Select: Move the cursor to the desired item with the F1 or F2 minute. Increase or decrease the value for the selected item with the A confirmation screen will appear. Navigating through the screens To return to the previous screen... RETURN button Eng-7

5. How to Use (continued) Function description Button operation 1 Main Main menu Initial setting Service Main display: 2/2 2 Initial setting menu Auto mode Administrator password Language selection 2/2 Main menu: 3 English Deutsch Italiano Svenska Select: Language selection Français Español Português Русский Move the cursor to the language you desire with the F1 the setting. screen will be displayed. Select a desired language. The system will not start-up without language selection. Language selection English Français Deutsch Español Italiano Português Svenska Русский Changes saved Main menu: A screen will appear that indicates the setting has been saved. Navigating through the screens To return to the previous screen... RETURN button Eng-8

5. How to Use (continued) Filter information English Lossnay 12:00 Sun will appear on the Main display when it is time to clean the filter. Fan Auto Mode Button operation 1 Main Main menu Timer Weekly timer Restriction Filter information Error information Main display: 1/2 2 Filter Filter information Please clean the parts above. Then press reset button. Main menu: Reset Press the F4 button to reset cleaning sign. 3 Filter Filter information Reset cleaning sign? button. Cancel OK 4 Filter information Cleaning sign reset A confirmation screen will appear. Main menu: Eng-9

5. How to Use (continued) Care of the remote controller wipe with a dry cloth to remove any remaining detergent. Do not use the following solvents. (They will change the quality and the color.) Main Main menu 1/2 Timer Weekly timer Restriction Filter information Error information Main display: Main Main menu 1/2 Timer Weekly timer Restriction Filter information Error information Main display: Timer Auto-Off time can be set to a value from 30 to 240 in 10-minute increments. Weekly timer Up to eight operation patterns can be set for each day. Error information When an error occurs, the following screen will appear. Check the error status, stop the operation, and consult your dealer. Error information 1/2 Error code 5101 Error unit LC(Lossnay) Model name VL-220CZGV-E Serial No. 01234567 Reset error:reset button Reset will appear. The model name and serial number will appear only if the information have been registered. Press the F1 or F2 button to go to the next page. Error information Contact information Dealer Tel 012-3456-7890 2/2 Contact information (dealer's phone number) will appear if the information have been registered. Reset error: Reset button Reset After-sales servicing of the remote controller unit should be ordered from the dealer from where this product was purchased. Eng-10

5. How to Use (continued) When using PZ-43SMF-E Power supply System example Remote controller (System components) Operation Operate the product by the remote controller. English A B C D H I E F G J K L M A Ventilation mode Displayed the ventilation mode status. Heat exchange By-pass Automatic ( ) * The mode appears only when the optional motorized damper (P-133DUE-E) is used. B Power Display on. C [TIMER] Display Displayed on-timer or off-timer duration. D [NOT AVAILABLE] Display the display of the function. or E Fan speed Display Displayed the selected fan speed. F [CHECK] Display Displayed together with the malfunctioning unit (3 digits) and an error code (4 digits). G [FILTER] Display Displayed when the accumulated operating time reaches at H [Ventilation mode] Button by-pass or automatic. * The mode can be switched only when the optional motorized damper (P-133DUE-E) is used. I [TIMER] Button Increasing 0:30 by pressing it once. J [ON/OFF] Button Switch for start and stop. K Operation lamp On during operation. Flashes when a malfunction occurs. L [Fan Speed] Button If this button is pressed when trying to switch the fan not change. M [FILTER] Button - When power is restored after an outage or when the models will return to the condition before the supply of power was interrupted. - Eng-11

5. How to Use (continued) Independent operation of the Lossnay unit: Operation Relevant button Relevant display items Sequence turns on. Setting the Ventilation mode * The mode can be switched only when the optional motorized damper (P-133DUE-E) is used. Selecting the fan speed the corresponding display will change in accordance with the sequence [HEAT EX.] (non-automatic) --> automatic) --> [AUTO]. current mode after three seconds have passed. Operation lamp Filter reset (Clear of the total operation time) Relevant button Relevant display items Sequence Press the FILTER button twice quickly, then FILTER indication will be disappeared. Double pressing Care of the remote controller Do not use the following solvents. (They will change the quality and the color.) where the product was purchased for more information. purchased. Eng-12

6. Maintenance To keep the Lossnay functions in good condition periodically (at least once every six month or more frequently depending on the operating environment). Clean dirt or dust in the Drain pan (supply air side) periodically (at least once every six month or more frequently depending on the operating environment). English WARNING Be sure to turn off the remote controller and the circuit breaker on the power board before cleaning and maintenance. injury. CAUTION Wear gloves during cleaning and maintenance. Failure to wear gloves may result in injury. During cleaning and maintenance, do not climb on an unstable stand. Injury may result if you tumble down. Securely install parts after cleaning and maintenance. Injury could result if parts fall. How to remove parts case builds up in some operating environments. Remove spill or be splashed with dew condensation water. case Eng-13

6. Maintenance (continued) Clean at least once every 6 months. Either lightly tap with your hand or wipe off dust with a vacuum cleaner. How to clean drain pan (supply air side) Clean the drain pan (supply air side) with a vacuum cleaner if Drain pan (supply air side) sure that no dew condensation water on the drain pan. Replacement Filter (P-220F-E) (sold separately). disposal methods designated in the region where you live. application. Type Supply Air Filter (contains 2 sheets) Model Approximate Notes 1 year Can be replaced with P-220SHF-E (replacement) Cannot be cleaned Medium 2 years Can be replaced with (replacement) Exhaust Air Filter P-220EMF-E (contains 2 Clean approximately sheets) once every 6 months Standard Replacement Filter (contains 2 sheets) P-220F-E Can be washed with water and reused 4 times Can be replaced with Assembling and checking after cleaning and maintenance CAUTION Securely install parts after cleaning and maintenance. Injury could result if parts fall. disassembly procedure in reverse. case. the following: page 9 or page 12. performance or quality. unit. (Doing so results in dirt clogging the surface of the application if you are worried about small insects getting inside or small dirt or dust particles. Eng-14

7. Troubleshooting Take the following actions if trouble shown in the table below occurs. If trouble is not corrected even after taking the required action, or if trouble other than that indicated in the following table occurs, turn OFF the circuit breaker on the power board, and then contact your dealer or an electrical contractor. English Symptom Cause Action No operation Operating noise has increased turn on. Remove obstacles. Burbling noise from product being discharged. Change the ventilation unit mode to low operation. This noise. Dew condensation water in The volume of the operating noise is different in different rooms Sometimes air stops being Noise sometimes gets louder because of the Dew condensation water sometimes builds up in some operating environments. room. The unit is operating in the supply air intermittent mode. dealer or an electrical contractor. It is not a malfunction. It is not a malfunction. It is not a malfunction. The outdoor air temperature is low. It is not a malfunction. Supply air sometimes is cooled be the outside air. Automatic supply air stop function/automatic supply air intermittent operation function To prevent dew condensation forming on the Lossnay core and water droplets from adhering to the product when there is a drop in the temperature of the outside air, operation of the supply air fan is controlled to approximately the following temperatures. Supply air stop mode (continuous supply air stopped) Outdoor air temperature -5 C or lower Supply air intermittent operation (24-minute operation followed by a 6-minute stop) -5 C or more from outdoor air temperature of 0 C Continuous operation Outdoor air temperature 0 C or higher - The exhaust fan runs continuously regardless of outdoor air temperature. temperature. Eng-15

Model Electrical power supply Ventilation mode Heat recovery mode Fan speed Fan speed 4 Fan speed 3 Fan speed 2 Fan speed 1 Input power (W) 80 35 18.5 8.5 Air volume (m 3 230 165 120 65 64 46 33 18 External static pressure (Pa) 164 84 44 13 82 84 85 86 Noise (db) (Measured at 1.5 m under the centre an anechoic chamber) 31 25 19 14 31 9. After-Sales Service Consult with your dealer about the after-sales services We will retain the functional repair parts for six years after terminating production of the product. The functional repair part means a part which is necessary to maintain the function of the product. - Abnormal noise or vibration due to the motor reaching the end of its service life The following are consumables: - Motor Manufactured by: Eng-16