Policy # MI_WASH Department of Microbiology. Page Quality Manual TABLE OF CONTENTS APPENDIX I STERILIZATION AND GLASS WASHING TECHNICAL MANUAL...

Similar documents
Autoclaves. Steam Autoclaves

Freestyle 2000 Cleaning

EZ9Plus & EZ11Plus Instructions on: Operating

SPIRAL PLATE COUNT METHODS (Raw Commingled Cow Milk) IMS #4. [Unless otherwise stated all tolerances are ±5%] GENERAL REQUIREMENTS

Enteral Pump Instructions for Use To Assemble When the low

FunTime Palace Popper 16oz Hot Oil Popcorn Machine

PERFORM Operating Document

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

PICNet CONFERENCE 2013

Steam sterilizer AHS-75-DRY

Operating instructions

Operations Manual. Part Number: For Research Use Only

A) Take your VMI Cleaner Disc and place the label side down onto loading tray.

CLINOCLAV steam sterilizer AH-21 L

ACME DIAGNOSTICS STANDARD OPERATING PROCEDURE

NS1000E Installation & Troubleshooting

TBR 40 1 GD Blood Refrigerator Instruction Manual. for BLOOD STORAGE REFRIGERATORS MODEL TBR 40 1 GD. (40 x 500ml Blood Bag Capacity)

5 Maintenance. A November

ESTEEM AUTOCLAVE SLIDING SINGLE DOOR:-

CM4-S(t) COMPUTER OPERATION (PROGRAMMED FOR POPEYE S) Programming key. Figure 1: CM4-S Computer with tactile switches.

Service Manual for X9.5 and Older Models

Formax FD 305 Personal Desktop Document Folder

Pharmawiki.in. Principle of HOT AIR OVEN (Dry heat sterilization)

Test Tube Rack. Test Tube

Instruction Manual for the Revolutionary Science Saniclave

CODE OF PRACTICE. No 11 CLEANING OF EQUIPMENT AND PREMISES

Using the Lely Robot Sampler CanWest DHI Robot Manual

OPERATION & MAINTENANCE MANUAL

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Safety Lab Goggles are required! Apron is optional!

ULTIMA series USER MANUAL

Glass and Dishwashers AMX / AUX Series

Experimental Procedure

Approval Block. Prepared by: Signature Date. Margaret Crouse 02 MAY Reviewed by: Signature Date. Brian Flynn 02 MAY 2014

WARNING. Do not put your hands in the ink cartridge slot, otherwise the needle inside the slot may cause injury. CAUTION

1 L Rotary Vacuum Evaporator Instruction Manual

Glass and Dishwashers. BarAid 500/800. Installation and. Starting from Serial No.:

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

Operator s Manual. The FREEDOM ROCKER. Contents. Congratulations!

Glassware Washers. WM Series. Efficient washing results for laboratory glassware

CASTLE 8666 LABORATORY GLASSWARE WASHING ACCESSORIES

Installation and Setup

APPENDIX 4. Thank you for choosing the Biomega BioClave steam sterilizer. HYDRAULIC DRAWING

CER-1 & CER-2 Installation & Testing Instructions

QuickStart Guide. Automated Support Removal System. PostProcess Technologies, Inc. REV C

February P Xerox 8265/8290/8365/8390 Wide Format Color Printer Hints and Tips

SimpleVIS Viscometer Reference Guide P

π H-7241 AIR CUSHION MACHINE PARTS uline.com BOX CONTENTS

Glass and Dishwashers AMX / AUX Series

NUMBER: R&C-ARF-4.0 ISSUED: REV. A: REV. B: REV. C: REV. D: REV. E: 2.1. Frequency of Contact and Non-Contact Bedding Changes:

STERILMATIC DIGITAL ELECTRIC STERILIZER INSTALLATION - OPERATION - MAINTENANCE STM-ED STM-EDX MODELS

LabClave.Com OPERATION & MAINTENANCE MANUAL. Horizontal Autoclave Model: Z-LABCLAVE-01-1 S/N

Conical Fermenter. Instructions

I N ST. MODEL 2912PS AUTOMATIC SLICER... with Portion Scale 701 S. RIDGE AVENUE TROY, OHIO

Shaking Hot Tubs. Orbital / Reciprocating Shaking Water Bath Liter 115V S 28 Liter 115V Liter 230V

requirements can be equipped with an additional product temperature control probe, and with a printer.

Epson Stylus. Pro GS6000 QUICK REFERENCE GUIDE

SUPPOSITORY MOLD RR 2159 Instruction Manual

Epson SureColor F9370 User's Guide

REVISION STATUS AMENDED PAGES. Initial release D. All

Safe Use of a Class II Biological Safety Cabinet

INSTRUCTION MANUAL Model: SU3022

Laboratory Glassware Washer G 7883

Glass and Dishwashers 402/452/502. (original instructions) (incl. Australian /502) Starting from Serial No.:

AMSCO C Series Small Steam Sterilizers 16 x 16" (406 x 406mm) 20 x 20" (508 x 508 mm)

USER MANUAL TOUCHCLAVE-LAB AUTOCLAVES

PERFORM Operating Document. Use and Maintenance of Undercounter High Temperature Dishwasher

Caution PROTECT YOUR FACTORY WARRANTY!

60+ NEED-TO-KNOW APPLIANCE MAINTENANCE TIPS

Microbiology. Sample collection, cultivation, and processing

Best Practice Guidelines For Cleaning, Disinfection and Sterilization of Critical and Semi-critical Medical Devices

Wash Baskets & Machine Accessories. For use in Miele Large Chamber Washers Models PG 8527 & PG 8528

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

KF-250 Knife Folding Machine

FD 2052 AutoSeal 12/2007 OPERATOR MANUAL FOURTH EDITION

2 in 1 steam and blend

LOADING EQUIPMENT. Always with you

Operating Manual "Mark II" Solid-State Digital Automatic Controlled Sterilizers


Altra Series Dampener

Betriebsanleitung Operating instructions Manuel d utilisation GS 402

Version 7 1/ LX

Version 7 1/ LXP

VS LD series vertical steam sterilizers

LABOKLAV. Autoclaves Made in Germany

User Manual for AirFlow Convection Oven

Page: Page 1 of 9 Author: Kristin Smith MAL Director: Dr. Peggy Borum FSHN Chair: Dr. Neil Shay

Advance Autoclave. Designed to give you more for your money with a high capacity for faster throughput: More features and benefits...

Purpose. Team Roles and Responsibilities. System Requirements. Instrument Processing Training

INSTRUCTION MANUAL HETO CBN 8 / 18 / C Cooling Baths ID: IM.doc Revision 1

Page 2 of 5. SOP SF SOP for Water Bath Maintenance

STERITITE INSTRUCTIONS FOR USE

PrimePour TM Operation Manual

INSTALLATION INSTRUCTIONS

WL380 QUICK START GUIDE

IWATA STUDIO SERIES MAXX JET AIR COMPRESSOR IS-1000

D3000. Installation and Operating Manual SAFETY D3000 SPECIFICATIONS PRODUCT DESCRIPTION

INSTALLATION MANUAL FOR MODELS: TERAZZA, TRACCIO, MILANO, CERRATO

CONTENTS. III. OPERATING INSTRUCTIONS... pg 7 LOADING DISPOSABLE SET (Figure 4)... pg 9. IV. INDICATORS AND ALARMS... pg 10

Instructions for set-up, use and cleaning. babybrezza.com 2017 Baby Brezza Enterprises LLC

Transcription:

Quality Manual Version: 1.1 CURRENT 1 of 13 Prepared by QA Committee Issued by: Laboratory Manager Revision Date: 4/14/2018 Approved by Laboratory Director: Annual Review Date: 5/1/2019 Microbiologist-in-Chief Uncontrolled When Printed TABLE OF CONTENTS AUTOCLAVE GETINGE NOVUSL - SMALL... 2 AUTOCLAVE GETINGE NOVUS1 LARGE... 5 DISHWASHER GETINGE T300... 8 HOT AIR OVEN MISDM4... 8 APPENDIX I STERILIZATION AND GLASS WASHING TECHNICAL MANUAL... 11 APPENDIX II INCUBATOR WASHING SCHEDULE... 12

Version: 1.1 CURRENT 2 of 13 AUTOCLAVE GETINGE NOVUSL - SMALL (MISDM1 small 20x20) I. Purpose To sterilize materials this must be free of organisms in order to be used e.g. growth media for bacteria, sterile pipettes and swabs, sterile saline, etc. II. Cycles Gravity Cycle (for wrapped and hard goods): Temperature: 121.0 o C Sterilization time: 45 minutes (default) may be changed if necessary touch temp button and use arrow up/down - then touch Acknowledge button. Dry Time: 12 minutes (default) may be changed if necessary touch temp button and use arrow up/down - then touch Acknowledge button. Liquids Cycle Temperature: 121.0 o C Sterilization time: 45 minutes (default) may be changed if necessary touch temp button and use arrow up/down - then touch Acknowledge button. Liquid Cool Time: 12 minutes (default) may be changed if necessary touch temp button and use arrow up/down - then touch Acknowledge button. Vacuum Cycle Not used Note: do not change any parameters with Setup button.

Version: 1.1 CURRENT 3 of 13 III. Operation 1. Turn power on (green knob) NOTE: The steam supply is always on. (If there is a problem with the steam supply the autoclave will still operate but will NOT complete the cycle. Check with Charge technologist). 2. Check that there is sufficient printer paper (no coloured stripes on paper strip). 3. Select desired cycle by pressing Next Cycle button. 4. Push door open knob at bottom right of door and load items (each item should have a piece of autoclave indicator tape attached). 5. Lift door up until it locks closed. 6. Press Start button 7. In case an error is noticed (eg. Wrong cycle, temperature, etc.), press Abort button and wait for display to return to Ready status. You may the correct the error and restart the cycle. 8. For Liquid cycle: Display will indicate Hot Liquids when the cycle is complete. For Gravity cycle: Display will indicate Complete when the cycle is complete. 9. Push door open knob (beware of hot steam) at bottom right of door and carefully remove hot items. 10. Check autoclave tape for darkened lines as a check on sterilization. 11. At the end of the day, turn power off (green knob). IV. Quality Control ATTEST spore ampoule 1. ATTEST spore ampoules (brown label for steam sterilization) are tested each week (Wednesday) to verify the autoclave is functioning properly. 2. Wrap ATTEST spore ampoule in a folded green towel. Secure the towel with autoclave tape. Label the tape with autoclave #1 or #2 and the sterilization time used. 3. Load the wrapped ATTEST spore ampoule and sterilize 4. When the cycle is complete, unwrap the ATTEST spore ampoule and label it with department (MICRO), autoclave #1 or #2 and the sterilization time used. 5. Complete a Microbiology requisition and take to Microbiology planting for accessioning. 6. The ATTEST spore ampoule will be processed by the QC bench technologist. Any positive ATTEST results will be reported to the Senior QA technologist for corrective action. QC Charts: Fill in daily and weekly QC Charts

Version: 1.1 CURRENT 4 of 13 Autoclave printout strips Save paper printout strips weekly (dated). Give to senior QA technologist monthly. V. Replace Printer Paper When coloured lines appear on the printer paper, replace it before operating the autoclave. 1. Carefully tear of old printout, label and save 2. Carefully remove cover from printer. 3. Carefully remove shaft that holds the paper roll from left side. 4. Tear of remaining paper from old roll. 5. Replace new roll on shaft an insert into printer. 6. Feed new paper into slot below the print-head until it comes through. 7. Replace cover VI. REPLACE PRINTER RIBBON 1. Carefully remove cover from printer. 2. Press on left side of the printer ribbon cartridge. The ribbon will pop out. 3. Replace with new cartridge by pressing on both ends of the cartridge. Be sure that the paper strip comes through the slot in the cartridge. 4. Replace cover VII. MAINTENANCE 1. The drain is cleaned weekly. Prepare a solution of Sodium triphosphate 1 tablespoon/l. 2. Remove the perforated metal cover from the autoclave. 3. Remove the drain screens (2) and rinse out any debris. 4. Using a large funnel, pour the Sodium triphosphate solution into the front drain until full. The solution will start to come out from the rear drain when the drain is full. 5. Replace drain screen and rack.

Version: 1.1 CURRENT 5 of 13 AUTOCLAVE GETINGE NOVUS1 LARGE (MISDM2 large 26x36) I. Purpose: To sterilize materials this must be free of organisms in order to be used e.g. growth media for bacteria, sterile pipettes and swabs, sterile saline, etc. II. Cycles Wrapped goods Cycle (for wrapped and hard goods): Temperature: 121.0 o C Sterilization time: 45 minutes (default) may be changed if necessary Key must be used to access this function. Press Cycle Value button and use arrow up/down to change. Dry Time: 12 minutes (default) may be changed if necessary Key must be used to access this function. Press Cycle Value button and use arrow up/down to change. Liquids Cycle Temperature: 121.0 o C Sterilization time: 45 minutes (default) may be changed if necessary Key must be used to access this function. Press Cycle Value button and use arrow up/down to change. Liquid Cool Time: 12 minutes (default) may be changed if necessary Key must be used to access this function. Press Cycle Value button and use arrow up/down to change. Hard goods Cycle Not used III. Operation 1. Turn power on (yellow button) (steam supply is always on). (If there is a problem with the steam supply the autoclave will still operate but will NOT complete the cycle. Check with Charge technologist). 2. Check that Printer On button is lit. 3. Check that there is sufficient printer paper (no coloured stripes on paper strip). 4. Select desired cycle by pressing Select Cycle button. 5. Push Door button to open the door. Load items (each item should have a piece of autoclave indicator tape attached).

Version: 1.1 CURRENT 6 of 13 6. Push and hold Door button until the door is fully closed (if you release the button too soon the door will open again). 7. Press Start button 8. In case an error is noticed (eg. Wrong cycle, temperature, etc.), press Abort button and wait for display to return to Cycle End status. You may the correct the error and restart the cycle. If the Fault light is lit, you must press it off to reset the autoclave and start over. 9. Display will indicate Cycle End when the cycle is complete. 10. Push Door button (beware of hot steam) on control panel and carefully remove hot items. 11. Check autoclave tape for darkened lines as a check on sterilization. 12. At the end of the day, turn power off (yellow button). IV. Quality Control ATTEST spore ampoule 1. ATTEST spore ampoules (brown label for steam sterilization) are tested each week (Wednesday) to verify the autoclave is functioning properly. 2. Wrap ATTEST spore ampoule in a folded green towel. Secure the towel with autoclave tape. Label the tape with autoclave #1 or #2 and the sterilization time used. 3. Load the wrapped ATTEST spore ampoule and sterilize 4. When the cycle is complete, unwrap the ATTEST spore ampoule and label it with the department (MICRO), date, autoclave #1 or #2 and the sterilization time used. 5. Complete a Microbiology requisition and take to Microbiology planting for accessioning. 6. The ATTEST spore ampoule will be processed by the QC bench technologist. Any positive ATTEST results will be reported to the Senior QA technologist for corrective action. QC Charts: Fill in daily and weekly QC Charts Autoclave printout strips Save paper printout strips weekly (dated). Give to senior QA technologist. V. Replace Printer Paper When coloured lines appear on the printer paper, replace it before operating the autoclave. 1. Carefully tear off old printout, label and save 2. Press the front panel of the printer in and release. The printer will pop out. Carefully slide the printer assembly out but not so far that it comes off its rail.

Version: 1.1 CURRENT 7 of 13 3. Carefully remove shaft that holds the paper roll from left side. 4. Tear of remaining paper from old roll. 5. Replace new roll on shaft and insert into printer. The paper should come off the top of the roll and under the black sensor. Feed new paper into slot below the print-head by turning the rubber roller with your fingernail until it comes through the slot in the printer cartridge. 6. Slide the printer assembly in gently until it snaps in place VI. Replace Printer Ribbon 1. Press on left side of the printer ribbon cartridge. The ribbon will pop out. 2. Replace with new cartridge by pressing on both ends of the cartridge. Be sure that the paper strip comes through the slot in the cartridge. VII. Maintenance 1. The drain is cleaned weekly. Prepare a solution of Sodium triphosphate 1 tablespoon/l. 2. Remove the interior rack using the special cart. 3. Remove the drain screen and rinse out any debris. 4. Using a large funnel, pour the Sodium triphosphate solution into the drain until full. 5. Replace drain screen and rack.

Version: 1.1 CURRENT 8 of 13 DISHWASHER GETINGE T300 I. Operation 1. Before washing glassware, paper labels MUST be removed or they will clog the water spray openings. 2. Turn on power 3. Settings: Extended Wash selected (10 minute wash) 4. Press Start 5. Wait until first rinse finishes ( minutes), then 6. Add detergent (Suma Classic M7 Mechanical Warewashing Detergent) 300 ml to the bottom of the washer. 7. Press Start 8. Wash (10 minutes) MAINTENANCE 1. The drain is cleaned weekly. 2. Pull interior rack forward to allow access to the inside of the washer. 3. Remove the 2 rectangular stainless steel filter trays from the bottom right side of the washer interior. 4. Rinse any debris from the filter trays and replace into the washer. 5. The water spray tubes are cleaned with a cleaning wire monthly to remove any debris blocking the jets. OPERATION HOT AIR OVEN MISDM4 1. Used for drying glassware and metal items. 2. Power on press green button. 3. Set temperature (default 200 o C) with dial 4. Set time with arrow up/down

Version: 1.1 CURRENT 9 of 13 OPERATING THE POURMATIC TM MODEL MP 320 I. Procedure 1. Have agar sterilized and tempering in the water bath. 2. Make sure tubing is sterilized and ready to be used. 3. Label all petri plates that will be required with the proper name of agar. 4. Plug in the Pourmatic TM model MP-320. 5. Load petri plates clockwise leaving an empty slot before the beginning of pouring. 6. Assemble the sterile tubing by inserting the nozzle in place and tighten. 7. Wrap the tubing tightly around the wheel being careful not to pinch the tubing. 8. Place the cover plate over the tubing and tighten the screws. 9. Insert the other end of the tubing into the flask containing the agar and cover the flask with a Petri dish with a slice cut out. 10. The flask containing the agar must be on a green towel(s) to prevent heat loss. 11. Make sure the setting is at 99 12. Press the manual button to begin pouring into a catch plate to get rid of air and bubbles. 13. Change setting to 00 and press calibrate and measure amount of agar into a 25 ml graduated cylinder 14. The setting must be changed to the amount of agar obtained in the graduated cylinder. 15. Then press the normal button to finalize the calibration. 16. The pouring amount could be changed to the desired amount by changing the setting. 17. When all plates are poured run hot water through the tubing to wash out the agar or use hot sterile water between different types of agar. 18. Disconnect the tubing and prepare it to be sterilized for the next usage. Note:

Version: 1.1 CURRENT 10 of 13 If the Pourmatic TM model MP-320 stops and begins to beep it is resetting itself. After the beeping has stopped press the manual button to resume operation. One long and steady beep means the machine is cooling off after one complete cycle. Press the batch button to restart. A problem in the machine is indicated by a number of short beeps. The problem area will light up on the front panel. Locate the problem as soon as possible before the agar solidifies then press the reset button to proceed. If the reset button is pressed before the problem if fixed the light will go off but the problem will not be resolved. To temporarily stop the operation press the stand-by button. To start it up again press the reset button then the manual button only if there is a plate in the pouring slot. If there is no plate in the pouring slot then press the batch button to resume

Version: 1.1 CURRENT 11 of 13 APPENDIX I STERILIZATION AND GLASS WASHING TECHNICAL MANUAL Sterilization and Glass Washing Area Workflow

Version: 1.1 CURRENT 12 of 13 Incubator Washing Schedule APPENDIX II INCUBATOR WASHING SCHEDULE

Version: 1.1 CURRENT 13 of 13 Manual Section Name: Sterilization Manual Record of Edited Revisions Number / Item Date of Revision Signature of Approval Annual Review April 30, 2009 Dr. T. Mazzulli Annual Review July 20, 2010 Dr. T. Mazzulli Annual Review July 31, 2011 Dr. T. Mazzulli Annual Review July 31, 2012 Dr. T. Mazzulli Annual Review August 26, 2013 Dr. T. Mazzulli Merge individual manuals into 1 document June 23, 2014 Dr. T. Mazzulli Annual Review Annual Review June 23, 2015 Dr. T. Mazzulli Update UHN/MSH logo in header Annual Review June 23, 2016 Dr. T. Mazzulli Annual Review June 23, 2017 Dr. T. Mazzulli Annual Review April 3, 2018 Dr. T. Mazzulli