IF8000. Users Manual. Protocols. for Interferential Therapy

Similar documents
SharperImage.com T.E.N.S. Massager with Handheld Control Operating Manual

USER MANUAL. AccuMed AP210 Mini Electronic Pulse Stimulator AP210 USER MANUAL. V2.0.1 Revised: March 9, 2017

Sport EMS Toning Pads Instruction Manual

USER MANUAL Please read the user manual carefully before using the product

Dual Channels - TENS Electronic Pulse Massager Unit Model No.: MT-5180

Electronic Pulse Massager

MAINTENANCE INSTRUCTIONS

EXTERNAL CARDIAC AMBULATORY TELEMETRY

Electronic Pulse Massager E4 (HV-F128-E)

DR. CLARK FAR INFRARED HEATING PAD

Massaging Heating Pad

Shiatsu Foot Massager +heat +air

DR. CLARK FAR INFRARED HEATING PAD

uknead Bella (ND-8000) User Manual

The Ionzyme DFII System

IB-CB200GB _Layout 1 16/12/ :02 Page 1. Instruction Manual. Customer Service Number +44 (0) CB-200-GB

USER/MAINTENANCE INSTRUCTIONS IMPORTANT SAFETY

VIBRATION MASSAGE SEAT

The ORIGINAL. User manual for neck and shoulder massager NM-089 WITH THE ZIPPER PREMIUM

home use only in accordance with the instructions provided in this manual. Please read these instructions carefully and retain for future use

Ozone Waterfall Foot and Leg Spa Bath Massager

INSTRUCTION MANUAL USJ-101

INFRARED MASSAGER Instruction Manual

Model ST243. Instructions for Use & Warranty Information

MG 510 To Go D Klopf-Massagegerät r Прибор для похлопывающего Gebrauchsanweisung... 2 массажа G Tapping massager Инструкция по применению..

Patient Manual EcoStar

Ultrasonic Pain Relief Massager INSTRUCTION MANUAL

Massaging Heating Pad

Instruction Manual. Head & Eye Massager with Acupressure and Heat Compression.

HAND-HELD INFRARED MASSAGER

Find thousands more great ideas online

IMPORTANT SAFETY INSTRUCTIONS

QUANTUM 400/400H/400P Intersegmental Traction Table Service & Instruction Manual

ENGLISH. The following symbols are used in the operating instructions and on the type plate: Warning of risks of injury or health hazards.

OVER 100 CONTACT POINTS Thai Spa Massage Cushion Instruction Manual Item #GM Sakar International, Inc. All rights reserved.

IMPORTANT SAFETY INSTRUCTIONS

TWO YEAR LIMITED WARRANTY (Valid in USA only) Luxury Foot Spa FootREJUVENATOR. with Wet & Dry Massage Center

Service Centers: Conair Consumer Products Inc. 156 Parkshore Drive. Brampton, Ontario L6T 5M1

IMPORTANT SAFETY INSTRUCTIONS

Instructions for use / Alarm unit, Fiber optic cable & Sensor patch ENGLISH

#1 BRAND IN MASSAGE* HMC-500MASSAGECHAIR INSTRUCTION MANUAL AND WARRANTY INFORMATION TWO YEAR LIMITED WARRANTY HMC-500

LIMITED ONE YEAR WARRANTY

VibraSpa. 2 limited warranty. Luxury Foot Spa. TWO YEAR LIMITED WARRANTY (Valid in USA only) Instruction Manual and Warranty Information.

Neck and Shoulder Massager DEEP RELIEF FOR HARD-TO-REACH MUSCLES

Multi-Flo Model #1545-KT. Multi-Flo Model #1545-F

QUANTUM 400/400H/400P Intersegmental Table Service & Instruction Manual

User manual Whirlpool

Compression therapy device & accessories Model 701A User manual

S10 Deep-Kneading Shiatsu & Tapping Seat Topper

557X-558X Comfort Care & Cozy Comfort, Premier Recliner 567X-5680 XL Cozy Comfort & XL Cozy Comfort Swing-Arm, Premier Recliner

Model sam-12 Ultrasonic Diathermy Device. Directions for Use

Model sam-12 Ultrasonic Diathermy Device. Directions for Use

Achieva. Ve nt i l at or with Flow Acceleration Limit and Apnea Backup. User s Manual

Shiatsu Foot Massager. Instruction Manual KH385L-B

Table of Contents. isleep 20 users manual

Table of contents Warnings and Cautions... 2 Location of Parts, Controls and Indicators... 7 Foot Spa Operation... 9 Using the Foot Spa...

OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL

OSIM usqueez Lite. Calf and foot massager. Merrimack, New Hampshire USA

INSTRUCTIONS AND WARRANTY

Foot DETOKS device MODEL: C01. Brand: Sinica. Operating instructions. NOT SUITABLE FOR PREGNANT AND Persons having received Pacemakers

Guide, Quick Start, Short, X-100 System

General Skills. yes. Device controls, buttons, indicators, and connectors

Heart Rate Monitor MODEL: SE128 USER MANUAL

USB Warming Gloves with Carbon Fiber Heating Elements Model No. MH-1000

Malem MO7 Wireless Alarm + Record Wetness Sensor and Toilet Trainer

Shiatsu Neck and Shoulder Massager KNEADING MASSAGE FOR HARD-TO-REACH MUSCLES

HeartWare HVAD System. Patient Manual

Alarm Tone Generator Model AG17

INSTRUCTIONS AND WARRANTY

Cryolipolysis fat dissolving device manual

INSTALLATION INSTRUCTIONS FOR SERIES 9 INTERMITTENT PILOT IGNITION CONTROL

MG 21. Beurer GmbH Söflinger Str Ulm, Germany Tel.: +49 (0)731 / Fax: +49 (0)731 / Mail:

Checkout Procedure Manual

VitalWrap System. Users Manual

VitalWrap System. Users Manual

P1195 DUAL TOURNIQUET MONITOR

CNR-SW1 Manual v1.0. Canyon SportMaster

Pink Magnetic Elliptical Bike

MULTIFUNCTION ROBTIC AUTO VACUUM CLEANER. MODEL NO.: M-788 Auto Charging With Remote Controller, Mop And UV Lamp

Contraindications Positive airway pressure therapy may be contraindicated in some patients with the following preexisting

DYGIZONE GJD910 Lighting Controller & Enunciator

TYDOM 315. * _Rev.2* GSM domotics transmitter. 1. Presentation

INSTALLATION AND USER MANUAL

HANDS-ON MODULE 5. CLEANING FLOW-i V3.0

R410a Installation and fault finding training

BubbleSpa Ultra. Luxury Foot Bubbler

MG 260 HD 2in1. D Shiatsu-Sitzauflage. T Koltuk üstü shiatsu. Kullanım kılavuzu r Массажная накидка шиацу на. Gebrauchsanweisung G Shiatsu seat cover

MG 300 HD-XL. T Koltuk üstü shiatsu Kullanım kılavuzu D Shiatsu-Sitzauflage Gebrauchsanweisung... 2

Made in USA. Sunoptic Technologies 6018 Bowdendale Avenue Jacksonville, FL 32216, USA (904)

Flowtron ACS900. Instructions For Use. ...with people in mind INT1 Rev A - 05/2015

DMG 973. Gas Burner Safety Control. For 2-stage forced draught and combi oil/gas burners, facility to connect an air damper unit

PR-L2466W- PA. Operating Instructions. High Performance Refrigerator PR-L2466W-PA

USER MANUAL. roller Classic PRO. roller Time PRO. roller EVO III PRO. Product: roller Serial no.: Date of purchase: Point of sale

HMC-600MASSAGECHAIR INSTRUCTION MANUAL AND WARRANTY INFORMATION ONE YEAR LIMITED WARRANTY

HILLS Series LED Code Pad User Manual

MAGNETIC ELLIPTICAL TRAINER SF-E3416 USER MANUAL

Salamander User Guide

1 Appendix - Product Specifications

INSTALLATION AND USER MANUAL

humantouch.com use & care manual

Transcription:

IF8000 Users Manual & Protocols for Interferential Therapy

Contents: About the IF8000 3 Get Started with IF8000 4 Controls and features 4 Electrodes and skin care 6 Batteries 7 Protocols 8 Indications and contraindications 21 Trouble Shooting 26 Technical Specifications 27 Page 2

About the IF8000 Interferential stimulation is used for a wide range of applications, generally with the purpose of either pain relief and/or muscle stimulation. Interferential stimulation differs from other types of electrical stimulation by its frequency and the principle of interference. A substantially higher frequency (4,000 Hz) than traditional stimulation (1-150 Hz), allows the applied stimulation to penetrate the skin with less resistance. The skin impedance is approximately 100 times less that of traditional TENS and NMES devices. The theory is that the more of the stimulation energy reaches the nerve and muscle fibers and hence becomes more productive. By applying two channels of 4,000 Hz stimulation in a cross pattern allows the center of the cross to beat with the interferential frequency (f1 minus f2). This is felt below the skin as a beating, pulsating feeling, when the interferential frequency is set below 20 Hz. Above 20 Hz the fast beating will just feel like constant stimulation. I/F (Interferential) stimulation is a constant stimulation and is indicated for symptomatic relief of chronic intractable pain, post-traumatic and post-surgical pain. A NMES (NeuroMuscular Electrical Stimulation) Mode is available for indications such as muscle re-education, relaxation of muscle spasms, prevention or retardation of disuse atrophy, immediate post-surgical stimulation of calf muscles to prevent venous thrombosis, increasing local blood circulation, and maintaining or increasing range of motion. In the NMES mode the stimulation comes on in six seconds intervals, thus allowing the muscle to rest from the contraction every six seconds. Important: This device must be ordered or prescribed by a licensed physician. Page 3

Get started with IF8000 Make sure the electrodes are placed properly on the skin (see Electrodes and Skin Care for details) and that the lead wires are properly connected. Turn on the unit by pressing ON for more than 1 second. A green or blinking light indicates that the leads and electrodes are properly connected and that the unit functions properly. Keep pressing until a comfortable level is reached, as indicated by your physician or therapist. To stop treatment, keep pressing until display and light goes out after 1 additional seconds ma will go to zero first). Thereafter remove the electrodes and place them on the plastic pad. Stimulation will continue for utes and automatically shut off thereafter unless the treatment timer is changed. During treatment the display will show Remaining Time left on upper line and Stimulation Level on lower line. The green light will be flashing with the set Interferential frequency (f.ex. 1 pulse per second.) Interferential stimulation at 4000 Hz consumes more energy than regular stimulation at lower frequency. It is therefore recommended to use the optional A/C adaptor for continued use. Controls and features. Turn unit ON and OFF: Press for 1 second to turn the unit on. The display will light up and the right LED will be flashing or constant green. Keep pressing to turn the unit off. It takes two additional seconds after reaching 0 ma to turn it off. If no controls have been touched for 60 seconds with level at or 60 seconds after timeout, the IF8000 will automatically turn off. Setting Stimulation Level: Use and controls to increase or decrease level. Do not use the PRG button. After 20 seconds the stimulation level is electronically locked as a safety feature to prevent the patient from unintentional increase in stimulation. To decrease, just press to reduce it by Page 4

at least 1 ma, which will unlock the safety feature. Thereafter you have 20 seconds to increase to desired level, before the lock is activated again. Any change in level or mode will unlock the level. Setting Interferential Frequency: Press PRG once and use or to increase or decrease the interferential frequency. Between 1 and 15 Hz the frequency can be felt as a beat in the center of the electrode arrangement, but above this the interferential frequency is too fast to be felt as an actual beat. Setting the Mode: Press PRG twice and use or to select the desired mode. I/F Mode: Stimulation is present constantly during the entire treatment time. Continuous. The I/F frequency remains as the preset. 1/1A. The I/F frequency changes abruptly between 30% below the preset and +60% above with each one second. 1/1R. The I/F frequency changes gradually between 30% below the preset and +60% above with each one second. 6/6A. The I/F frequency changes abruptly between 30% below the preset and +60% above with each six seconds. 6/6R. The I/F frequency changes gradually between 30% below the preset and +60% above with each six seconds. NMES Mode: Stimulation is applied for 6 seconds, then paused for 6 seconds. Commonly known as NeuroMuscular Electrical Stimulation. Up-ramp is 1 second and down-ramp is 0.5 second, fixed. NM C. The I/F frequency remains as the preset. NM 1/1A. The I/F frequency changes abruptly between 30% below the preset and +60% above with each one second. NM 1/1R. The I/F frequency changes gradually between 30% below the preset and +60% above with each one second. NM 6/6R. The I/F frequency changes gradually between 30% below the preset and +60% above with each six seconds. Page 5

Setting the Treatment Time: Press PRG three times and use or to select the desired Treatment Time. Keep pressing to set a Continuous Treatment Time. Compliance data: Press PRG four times and use to display the usage time in minutes and number of times used, when prompted by text in display. Only stimulation levels above 5 ma are recorded as usage time. The compliance meter can be reset by pressing to show prompt in display and thereafter press twice to reset both parameters to zero. Return to factory settings: Press PRG five times and display will prompt the choice to reset all parameters to factory settings. This is particularly useful if the user is unsure if the settings are correct and is a good starting point for variations. Factory settings are: Frequency: 1Hz Mode: Continuous I/F Electrodes: 4 Change electrode configuration (2 or 4): Press PRG six times and use when prompted to change between the two configurations. Electrodes and skincare Proper skin care will help make the use of this device more comfortable and trouble-free. Prior to treatment, wash the areas where the electrodes will be placed with mild soap and water, rinse and dry the skin thoroughly. If necessary, remove excess body hair. The IF8000 is intended to be used with re-usable, self-adhesive electrodes. Extended number of uses can be obtained by adding water to the adhesive surface immediately after each use and placing them on the plastic pad. They will regain their conductivity and adhesiveness as compared to leaving them dry. Sterile electrodes may be required for some post-op applications. Page 6

Batteries One 9 volt Alkaline battery is used. The battery compartment on the back of the device opens by sliding the cover downwards. Please ensure to dispose the used batteries properly. Rechargeable batteries are not recommended as they only have a short usage time and are not charged while in the device. Page 7

Place one electrode from left channel (black) over the lower palm of the hand. This may require some trial and error to find when the stimulation is felt in the area of pain. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Press PROGRAM once more and use to set Mode to NM6/6R. Freq 15 Hz Mode NM 6/6R Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Right View (Same Hand) Left View (Same Hand) Page 8

Recommended twice a day. Place 4 electrodes as shown with the black leads opposite to each other. (Sterile electrodes may be required for post-op protocol) Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Page 9

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Page 10

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 100 Hz. Freq 100 Hz Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Use to set level to comfortable strength. The timer will count down from and shut off after. Page 11

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Page 12

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Page 13

Place the 2 electrodes as shown with the black leads opposite to each other. Place the 2 electrodes with the gray leads as shown (red). Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Right View (Same Foot) Left View (Same Foot) Page 14

Place 4 electrodes as shown with the black leads opposite to each other. Place the 2 electrodes with the gray leads as shown (red). Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Left View (Same Foot) Right View (Same Foot) Page 15

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Right View (Same Arm) Left View (Same Arm) Page 16

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Right View (Same Leg) Left View (Same Leg) Page 17

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode to NM6/6R. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Page 18

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 100 Hz. Freq 100 Hz Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Use to set level to comfortable strength. The timer will count down from and shut off after. Page 19

Place 4 electrodes as shown with the black leads opposite to each other. Press to turn the unit on. Use to set level to a strong, but comfortable strength. (xx ma). The timer will count down and shut off after. Press PROGRAM once and use to set Freq. to 15 Hz. Freq 15 Hz Press PROGRAM once more and use to set Mode tonm6/6r. Press PROGRAM five (5) times more (or leave the controls for 10 seconds). Mode NM 6/6R Use to set level to a strong, but comfortable strength. The timer will count down from and shut off after. Page 20

Indications, contraindications, precautions, safety and warnings. Safety References Zynex Medical (Zynex) is only responsible for the safety, reliability and function of the device when repairs, adjustments and changes have been carried out by persons authorized by Zynex for such work and the device is used according to the user manual. Repairs and technical safety tests shall only be carried out by trained personnel. Indications This Zynex device has been designed for muscle re-education, prevention of retardation of disuse atrophy, increase local blood circulation, maintain or increase range of motion, relaxation of muscle spasms, edema reduction. Symptomatic relief of chronic intractable pain, post-traumatic and post-surgical pain. (IF Mode) Relaxation of muscle spasms. Prevention of retardation of disuse atrophy. Increasing local blood circulation. Muscle re-education. Immediate post-surgical stimulation of calf muscles to prevent venous thrombosis. Maintaining or increasing range of motion. This stimulator should only be used under supervision for adjunctive therapy for the treatment of medical diseases and conditions. Contraindications The device must not be used on patients with cardiac pacemaker. The device must not be used with stimulation over carotid sinus nerves. The stimulation must not be applied transcerebrally. The device must not be applied with undiagnosed pain syndromes until etiology is established. This stimulator should not be used on patients with cardiac demand pacemakers. Electrodes should not be placed so that current will be applied to the carotid sinus (neck) region or transcerebally (through the head). This stimulator should not be used whenever pain syndromes are undiagnosed, until etiology is established. (In I/F Mode) Page 21

Warnings In I/F Mode The safety of tens devices for use during pregnancy or birth has not been established. This device is not effective for pain or central origin. (This includes headache) This device should only be used under the continued supervision of a physician. This device does not have curative value. This device offers symptomatic treatment such as suppresses the sensation of pain which would otherwise serve as a protective mechanism. The user must keep the device out of the reach of children. Electronic monitoring equipment (such as ECG monitors and ECG alarms) may not operate properly when this device is in use. In NMES Mode: The long-term effects of chronic electrical stimulation are unknown. Stimulation should not be applied over the carotid sinus nerves, particularly in patients with known sensitivity to the carotid sinus reflex. Stimulation should not be applied over the neck or mouth. Severe spasm of the laryngeal and pharyngeal muscles may occur and the contractions may be strong enough to close the airway or cause difficulty in breathing. Stimulation should not be applied transthoracically in that the introduction of electrical current into the heart may cause cardiac arrhythmias. Stimulation should not be applied transcerebrally. Stimulation should not be applied over swollen, infected, or inflamed areas of skin eruptions, e.g. phlebitis, thrombophlebitis, varicose veins, etc. Stimulation should not be applied over, or in proximity to, cancerous lesions. Precautions For the I/F Mode: 1. Isolated cases of skin irritation may occur at the site of the electrode placement following long-term application. 2. Effectiveness is highly dependent upon patient selection by a person qualified in management of pain patients. Page 22

For the NMES Mode: 1. Safety of powered muscle stimulators for use during pregnancy has not been established. 2. Caution should be used for patients with suspected or diagnosed heart problems. 3. Caution should be used for patients with suspected or diagnosed epilepsy. 4. Caution should be used in the presence of the following: When there is a tendency to hemorrhage following acute trauma or fracture; Following recent surgical procedures when muscle contraction may disrupt the healing process: Over the menstruating or pregnant uterus; and Over the areas of the skin which lack normal sensation. 1. Some patients may experience skin irritation or hypersensitivity due to the electrical stimulation or electrical conductive medium. The irritation can usually be reduced by using an alternate conductive medium, or alternate electrode placement. 2. Electrode placement and stimulation settings should be based on the guidance of the prescribing practitioner. 3. This device should be kept out of reach of children. 4. This device should be used only with the leads and electrodes recommended for use by the manufacturer. 5. This device should not be used while driving, operating machinery, or during any activity in which voluntary muscle contractions may put the user at undue risk of injury. Adverse Reactions: Skin irritation and burns beneath the electrodes are potential adverse reactions. Page 23

Trouble-shooting. Problem Unit stays on even after treatment ends. Hold Off button down for 2 seconds to shut unit off else unit will shut off automatically after 5 minutes of no stimulation. Alternatively you can start a new treatment session now, without having to start from scratch. Can not increase level from its current setting. Turn level down 1 ma to unlock this safety feature then turn it up to the desired level/intensity. Intensity level is always locked after 20 seconds of no change of settings. Do not feel the traditional I/F beat in the center of the four electrodes. Check that the lead wires are connected correctly to the electrodes (red opposite to each other, black opposite to each other) Display shows electrode alarm. Check your electrodes, they must be fresh and stick well. Then check your electrodes again, possibly change to new electrodes. Then check that all four electrodes are connected to lead wires and that both lead wires are connected to the unit. Eventually put all four metal pins together to short-circuit the outputs that should make the electrode alarm go away and thereby prove that the problem IS the electrode quality. Page 24

Technical specifications: Carrier frequency: 4000 Hz nominal Modulation frequency: Continuous 4001-4150 Hz, freq. Shift modes 4001-4240 Hz Factory settings is 1 Hz. I/F Modes: Continuous, 1/1A, 1/1R, 6/6A, 6/6R NMES Modes: Continuous, 1/1A, 1/1R, 6/6R NMES parameters: I/F modes functional. On-time is 6 seconds, off-time is 6 seconds. Up-ramp is 1.0 sec. And down-ramp is 0.5 sec. Treatment timer: Continuous, 10-100 minutes, in 10 minutes steps. Factory setting is utes. Compliance meter: Records total usage time in minutes and number of times used. Can be reset. Dimensions: 4.5 x 2.5 x 0.9 in. Weight: 5 oz. Incl. Battery. Warranty: 3 Years manufacturers warranty on materials and workmanship. Accessories excluded. Page 25

P/N 300200 Rev 00 9990 Park Meadows Drive, Lone Tree, CO 80124 800-495-6670 www.zynexmed.com