Low GWP Refrigerants for Air Conditioning Applications

Similar documents
Low Global Warming Refrigerants For Commercial Refrigeration Systems

Low GWP Refrigerants for Air Conditioning and Chiller Applications

ANALYSIS OF LGWP ALTERNATIVES FOR SMALL REFRIGERATION (PLUGIN) APPLICATIONS

Performance of R-22, R-407C and R-410A at Constant Cooling Capacity in a 10

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Study of R161 Refrigerant for Residential Airconditioning

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

Air-Cooled Heat Exchanger Performance for R410A

R32 Compressor for Air conditioning and Refrigeration applications in China

Performance Measurement of R32 Vapor Injection Heat Pump System

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Evaluation of HCFC Alternative Refrigerants

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

R-404A Alternative with Low Compressor Discharge Temperature

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) â Summary of Phase II Testing Results

TEST REPORT #4. Travis Crawford Dutch Uselton. Lennox Industries Inc Metrocrest Drive Carrollton, TX 75006

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

Performance Comparison of Hydronic Secondary Loop Heat Pump and Conventional Air-Source Heat Pump ABSTRACT 1. INTRODUCTION

HFO-1234yf Performance in a Beverage Cooler

TEST REPORT #47. System Drop-in Test of R-32 and Refrigerant Blends ARM-71a, HPR2A, L-41-2 and DR-5A in a Five-Ton R-410A Rooftop Packaged Unit

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

Purdue e-pubs. Purdue University

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Comparison Of Hermetic Scroll And Reciprocating Compressors Operating Under Varying Refrigerant Charge And Load

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

A study of high efficiency CO2 refrigerant VRF air conditioning system adopting multi-stage compression cycle

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Control Method Of Circulating Refrigerant Amount For Heat Pump System

Comparison of Performance of a Residential Air- Conditioning System Using Microchannel and Finand-Tube

New High Performance, Low GWP Refrigerants for Stationary AC and Refrigeration

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

A Comparison Between Refrigerants Used In Air Conditioning

Understanding Applications for Alternative Refrigerants

TEST REPORT #53. System Drop-in Test of Refrigerant Blend DR-55 in a Five-Ton R-410A Rooftop Packaged Unit

Understanding Applications for Alternative Refrigerants

Effects of Frost Formation on the External Heat Transfer Coefficient of a Counter-Crossflow Display Case Air Coil

AHRI Low Global Warming Potential Alternative Refrigerants Evaluation Program (Low-GWP AREP) Summary of Phase I Testing Results

Understanding Applications for Alternate Refrigerants. Ron Bonear Emerson Climate Technologies

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Performance Comparisons Of A Unitary Split System Using Microchannel and Fin-Tube Outdoor Coils, Part I: Cooling Tests

Feasibility of Controlling Heat and Enthalpy Wheel Effectiveness to Achieve Optimal Closed DOAS Operation

SOLSTICE L40X (R-455A)

TEST REPORT #14. System Drop-In Test of Refrigerant Blend ARM-42a in an Air-Cooled Screw Chiller

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Refrigerant Glide and Effect on Performances Declaration

Experimental Investigation on the Performance of Ground-source Heat Pump with the Refrigerant R410A

Performance of CO2 Cycles with a Two-Stage Compressor

Oyelami S., Bolaji B. O.

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Dynamic Simulation of Liquid Chillers

Enhancement of the Separate Sensible and Latent Cooling Air-Conditioning Systems

Honeywell Refrigerant Update

Visualization of Evaporatively Cooled Heat Exchanger Wetted Fin Area

Systematic Study of the Solution Properties of Low Global Warming Potential R-404A Replacement Refrigerant Blends with Various Polyol Ester Lubricants

Effects of Non-Uniform Refrigerant and Air Flow Distributions on Finned- Tube Evaporator Performance

TEST REPORT #65. Compressor Calorimeter Test of Refrigerant L-41-2 (R-447A) in a R-410A Scroll Compressor

Development and Performance Measurements of a Small Compressor for Transcritical CO2 Applications

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

Oil Return Measurements In A Unitary Split System Air Conditioner Using Different Refrigerant Mixtures

The Current Path of Refrigerants

Performance Comparison of R32, R410A and R290 Refrigerant in Inverter Heat Pumps Application

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Evaluation and Development of Air-conditioners using Low GWP Refrigerant

Sub-Critical Operation of the CO2 Expander/ Compressor

Experimental Investigation on Condensation Performance of Fin-and-Flat-Tube Heat Exchanger

TEST REPORT #43. System Drop-in Tests of Refrigerants L-41-1, L-41-2, and R-32 in Water-to- Water Heat Pump

TEST REPORT #32. System Soft-Optimized Test of Refrigerant D2Y60 in Air Source Heat Pump

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Efficiency of Non-Azeotropic Refrigerant Cycle

Wide-Boiling Refrigerant Mixtures - Technical and Commercial Challenges

Performance Study on A Window Type Air Conditioner Condenser Using Alternative Refrigerant R407C

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Development of an Open Drive Scroll Compressor for Transportation Refrigeration

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

Experimental Study of Fouling Performance of Air Conditioning System with Microchannel Heat Exchanger

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

The Development Of High Efficiency Air Conditioner With Two Compressors Of Different Capacities

TEST REPORT #6. Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Low-GWP Alternative Refrigerants Evaluation Program (Low-GWP AREP)

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

Improving Heating Performance of a MPS Heat Pump System With Consideration of Compressor Heating Effects in Heat Exchanger Design

TEST REPORT #34. Compressor Calorimeter Test of Refrigerant DR-7 in a R-404A Scroll Compressor

Recommendations to retrofit positive existing installations running with HFCs (R404A & R507) RETROFIT POSITIVE & MEDIUM REFRIGERATING SYSTEMS

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

DOE and EPA Impacts to Commercial Refrigeration

Performance Rating of Commercial and Industrial Unitary Air-Conditioning Condensing Units

Experimental Investigation of Closed Loop Oscillating Heat Pipe as the Condenser for Vapor Compression Refrigeration

Performance Analysis of a Miniature-Scale Vapor Compression System for Electronics Cooling: Bread Board Setup

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Low GWP Refrigerants for Air Conditioning Applications Samuel F. Yana Motta Honeywell International Inc, Buffalo, NY, USA, Samuel.YanaMotta@Honeywell.com Mark W. Spatz Honeywell International Inc, Buffalo, NY, USA, Mark.Spatz@Honeywell.com Ankit Sethi Honeywell International Inc, Buffalo, NY, USA, Ankit.Sethi@Honeywell.com Elizabet Vera Becerra Honeywell International Inc, Buffalo, NY, USA, Elizabet.VeraBecerra@Honeywell.com Follow this and additional works at: http://docs.lib.purdue.edu/iracc Yana Motta, Samuel F.; Spatz, Mark W.; Sethi, Ankit; and Vera Becerra, Elizabet, "Low GWP Refrigerants for Air Conditioning Applications" (2014). International Refrigeration and Air Conditioning Conference. Paper 1553. http://docs.lib.purdue.edu/iracc/1553 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

1670, Page 1 Low GWP Refrigerants for Air Conditioning Applications Ankit SETHI 1*, Samuel YANA MOTTA 2, Elizabet VERA BECERRA 3, Mark W. SPATZ 4 Honeywell International, Buffalo Research Laboratory, Buffalo, NY, USA 1 Ankit.Sethi @Honeywell.com 2 Samuel.YanaMotta@Honeywell.com 3 Elizabet.VeraBecerra@Honeywell.com 4 Mark.Spatz@Honeywell.com * Corresponding Author ABSTRACT Refrigerants with low environmental impact have been developed as replacements for R22 and R410A in stationary air conditioning applications. Two low global warming potential (GWP) refrigerants, L-20 and L-41 have been evaluated in representative residential equipment. This study discusses the performance of R22 replacements at high ambient temperatures (warm climate) and potential design changes. Replacements of a common HFC refrigerant R410A are discussed for use in water heating heat pumps. In addition, replacements for R22 and R410A are also discussed for positive displacement chiller applications. Theoretical and experimental results are discussed in detail showing the benefits of using these new fluids Keywords: Low GWP Refrigerants, Water Heating Heat Pumps, Positive Displacement Chiller 1. INTRODUCTION Refrigerants that are in common use today, hydro fluorocarbons (HFCs), have the benefits of high energy efficiency, safety in use, properties that enable the design of cost effective systems, and from an environmental perspective they have no impact on stratospheric ozone. Despite these attributes, the air conditioning and refrigeration industry is now looking for replacements due to the growing global concerns around climate change, since many of these refrigerants have relatively high global warming potentials. New molecules with the positive attributes of both high thermal performance and low environmental impact, in addition to a mosaic of other essential characteristics, are currently in development. These materials maintain the high level of system efficiency we are accustomed to with HFC refrigerants but with significantly lower global warming impact than current refrigerants. They also exhibit significantly lower flammability characteristics than the much more flammable hydrocarbons. Since 2013, there has been strong push towards the phase out of hydro chlorofluorocarbons (HCFCs) like R22 in the Middle East countries due to the directives of the Montreal Protocol phase out plan for Article 5 countries. Along with this certain Gulf Countries like Saudi Arabia have implemented new stringent efficiency requirements for residential air conditioners. HFC refrigerants like R407C and R410A are being evaluated as R22 replacements in these countries. However, performance of these refrigerants deteriorates at high ambient temperatures which are observed in these countries for a significant part of the year. Since there are no such immediate alternatives available, there has been a heightened focus on evaluating refrigerants with low GWP. Utilizing these refrigerants can help these countries to directly move on to the low GWP platform without going through HFCs. In light of these developments, this paper will discuss the experimental results for replacements for R22 in a ductless mini-split air conditioner with focus on performance at high ambient temperatures. Evaluation of two refrigerants, a HFC R407C and a low global warming refrigerant L-20 is presented. Air to water heat pumps (hydronic systems) are very commonly used in Europe for domestic hot water. A large proportion of hydronic systems in Europe use R410A as a refrigerant. The latest F-gas directives provide indication on restricting the use of refrigerants having high global warming potential. Hence, there is a keen interest in low GWP R410A replacements suited for these systems. A theoretical analysis of the replacements of R410A in hydronic systems is presented. Positive displacement chillers

1670, Page 2 are often used in air conditioning applications. This study will discuss properties and performance of potential replacements for refrigerants R22 and R410A in positive displacement chillers employing DX heat exchangers. 2. STATIONARY AIR CONDITIONING FOR HIGH AMBIENT CONDITIONS 2.1 Testing of Mini-Split Air Conditioner An experimental investigation of a ductless split (mini-split) cooling only system was carried to evaluate R22 replacements for high ambient conditions. The system was originally designed to operate with R22. The system has a nominal capacity of 7.0 kw and nominal COP of 3.0. The test conditions were based on ISO standard 5151 [1] and are shown in Table 1.The system has a fixed speed rotary compressor with fin-tube heat exchangers as outdoor and indoor coils with internally micro-finned tubes. A capillary tube is used as an expansion device. Two R22 replacements, R407C and a HFO based low GWP blend L-20 were evaluated. L-20 is a refrigerant blend with a GWP under 300 that is mildly flammable with a provisional ASHRAE flammability classification of 2L. Figure 1 shows a schematic of the test facility. All tests were performed inside environmental chambers equipped with instrumentation to measure both air-side and refrigerant-side parameters. Refrigerant flow was measured using a coriolis flow meter while air flow and capacity was measured using an air-enthalpy tunnel designed according to industry standards [2],[3]. The humidity of the air was measured using dew point meters with an accuracy of ±0.2 ºC. All primary measurement sensors were calibrated to ±0.15ºC for temperatures and ±0.04 kpa for pressure. 2.2 Performance A drop-in test was performed for both L-20 and R407C with a capillary tube resized for each refrigerant. L-20 had a drop-in capacity and efficiency of 97% and 96% respectively compared to R22. The indoor and outdoor heat exchangers were modified without addition of any heat transfer area in order to obtain improved performance with L-20. Table 2 shows some key properties of refrigerants at ISO T1 condition. L-20 offers more than 80% reduction in GWP over R22 and R407C. The suction and the discharge pressures and the discharge temperature of L-20 are similar to R22 indicating it to be a suitable replacement. The mass flow rate of L-20 is 20% lower than R407C leading to lower pressure drop in the heat exchangers and thereby improving system efficiency. The performance of L-20 and R407C in the improved system was compared to the baseline R22 at different ambient temperatures as shown in Table 3. The performance of L-20 matches R22 across the entire range of ambient temperatures. At high ambient conditions, the performance of L-20 is similar to R22 due to similar critical temperatures. L-20 reduces the direct emissions substantially due to lower GWP (295) and lower charge (85%). Hence, L-20 should be considered a low GWP refrigerant option for systems like the one tested that are designed to use either R22 or R407C and applied in locations that can safely use a mildly flammable refrigerant. 2.3 System Design for L-20 In order to obtain better performance with L-20 several changes were made in the system originally designed for R22. The circuitry of indoor and outdoor heat exchangers was modified, without addition of any additional heat exchange area, to account for the glide of L-20 and obtain better matching of temperature profiles of the air and the refrigerant. Figure 2 shows the evaporator circuitry in the original system and the modified system. A more restrictive capillary tube is needed for L-20 compared to the R22 system to obtain improved performance. Since, the mass flow rate of L-20 is about 80% of R22, further improvement in system performance is possible by using smaller diameter tubes or by reducing the number of circuits.

1670, Page 3 Table 1: Mini-Split AC Test Conditions Cooling Mode Test Indoor Ambient Outdoor Ambient Condition Db WB DB WB C C C C T1 27 19 35 24 T3 29 19 46 24 T3 max 32 13 52 31 OUTDOOR ROOM Air-Flow Measuring Nozzles Blower (coupled to a VFD) Blower (coupled to a VFD) Air Sampling (outlet) INDOOR ROOM Temperature Grids Compressor Flow Meter Temperature Grids Condenser Air Inlet Torque Meter Elect. Motor Air Inlet Evaporator Air Sampling (inlet) Figure 1. Schematic of Test Facility Table 2: Refrigerant Properties at ISO T1 condition Refrigerant GWP T crit Pres. ( o P C) suction P discharge Ratio T dis. dp cond dp evap Mass Flow R22 1760 96 100% 100% 100% 82 100% 100% 100% L-20 295 90 100% 107% 107% 83 66% 88% 81% R407C 1624 86 97% 110% 113% 76 82% 123% 99% Table 3: Performance comparison of R22 alternatives Refrigerant L-20 R407C Condition Capacity % of R22 COP % of R22 T1 (35/27) 99% 98% T3 (46/29) 100% 100% T3(H) (52/32) 101% 100% T1 (35/27) 97% 93% T3 (46/29) 98% 95% T3(H) (52/32) 99% 96% Charge % of R22 85% 94%

1670, Page 4 Original Modified Air Flow Figure 2. Evaporator Circuitry 3. AIR-TO-WATER HEAT PUMP APPLICATIONS (HYDRONIC SYSTEMS) These types of heat pumps are used for floor heating or similar applications. Current systems employ R410A as refrigerant. Typical operating conditions [1] require the water delivered at 35ºC (standard rating) with a temperature difference of 5ºC after passing through the floor heating system. Outdoor ambient temperature varies from 7ºC (standard rating) to -15ºC (lowest rating value). 116% L41 Efficiency L20 efficiency R32 Efficiency 225 114% R32 T-discharge 200 % of R410A 112% 110% 108% 106% 104% 102% L41 T-discharge L20 T-discharge R410A T-discharge Maxim. Disch. Temp. 130 C Prefer. Disch. Temp. 120 C 175 150 125 100 75 50 Discharge Temperature ( C) 100% 25 98% 0-35.0-30.0-25.0-20.0-15.0-10.0-5.0 0.0 5.0 10.0 15.0 Evaporating Temperature ( C) Figure 3. Standard system results

1670, Page 5 Low ambient temperatures represent a challenge for the performance (capacity, efficiency) and reliability (discharge temperature) of the system. Most compressor manufacturers have a maximum temperature limit of 130ºC with a preferred value of 120ºC. [4] A thermodynamic evaluation was carried out for two types of systems: 1) A typical system with a standard compressor, 2) An advanced system equipped with a vapor injected compressor. A vapor injected compressor is used in a system to extend the operating envelope by improving efficiency and reducing discharge temperature. Refrigerants considered were R410A as baseline, R32, L-41 and L-20. Figure 3 shows results for a standard compressor system. Condensing temperature was kept constant at 45ºC to represent a standard rating of 35ºC with 10ºC TD. Evaporating temperatures were varied from 10ºC to -30ºC which with a 6ºC TD would represent outdoor ambient temperatures of 16ºC to -24ºC. Compressor isentropic efficiency was assumed as 60%. The results show all refrigerants providing reasonable efficiency with an advantage for L-20 (4% better than R410A) over L-41 and R32 (2% better than R410A) in that order. Further examination of discharge temperature shows R32 limited to an evaporation temperature of -2ºC (4ºC outdoor), while L-41 goes down top - 10ºC (-4ºC outdoor) and L-20 follows closely R410A with -20ºC (-14ºC outdoor). L-20 seems to be a choice that would extend significantly the operating envelope. L41 Efficiency L20 efficiency R32 Efficiency 116% 225 114% R32 T-discharge 200 % of R410A 112% 110% 108% 106% 104% 102% L41 T-discharge L20 T-discharge Maxim. Disch. Temp. 130 C R410A T-discharge Prefer. Disch. Temp. 120 C 175 150 125 100 75 50 Discharge Temperature ( C) 100% 25 98% 0-35.0-30.0-25.0-20.0-15.0-10.0-5.0 0.0 5.0 10.0 15.0 Evaporating Temperature ( C) Figure 4. Evaluations for a vapor injected system Further evaluations of a vapor injected system are shown in figure 4. Additional assumptions were needed so we used compressor isentropic efficiencies of 60% for each stage, while the heat exchanger effectiveness was of 80%. The performance of L-20 is significantly better than R410A and any other alternative (4% to 8%), while L-41 is better than R410A (1% to 4%), and R32 matches R410A. Additional examination of discharge temperature shows R32 limited to an evaporation temperature of -5ºC (1ºC outdoor), while L-41 goes down to an evaporation temperature of -16ºC (-10ºC outdoor). L-20 follows closely R410A with evaporation temperature limited to -28ºC (- 22ºC outdoor). These initial evaluations show L-20 as having the largest potential not only to match operating envelope but to give superior performance. 4. POSITIVE DISPLACEMENT CHILLER APPLICATIONS A performance analysis was carried out for an air cooled 20 ton (70 kw) chiller using a lumped parameter modeling approach for the heat exchangers. The water inlet and outlet temperatures were assumed to be 12 o C and 7 o C respectively. The analysis was performed at an ambient air temperature of 35 o C. The evaporator superheat and condenser subcooling were set at 5.5 o C. An assumption was made that the volumetric and isentropic efficiencies were the same for all refrigerants. Performance results obtained for R410A alternatives with our analysis are shown in Table 4. Performance results obtained for an alternative to R407C with are depicted in Table 5.

1670, Page 6 Table 4: Positive Displacement Chiller Analysis R410A Alternatives Results Tevap ( o C) Tcond ( o C) P suction (kpa) P discharge (kpa) dp cond (kpa) dp evap (kpa) Mass Flow (kg/h) Capacity (kw) COP R410A 3.2 50.9 871.8 3165.4 70 20 1634 69.7 3.50 L-41 (Drop In) 2.9 51.5 717.5 2774.1 52.7 14.5 1130 62.6 3.60 Comparison -0.3 0.6 82.0% 87.6% 75.2% 72.5% 69.0% 89.8% 102.9% L-41 (Circuits mod.) 3.1 50.9 719.5 2747.7 72.3 19.5 1130 63.4 3.60 Comparison -0.1 0.0 82.5% 86.8% 103% 97.5% 69.0% 91.0% 102.9% L-41 (Comp. mod.) 2.7 51.8 710.1 2804.4 68.8 20.6 1256 69.7 3.5 Comparison -0.5 0.9 81.4% 88.6% 98.2% 103.0% 76.9% 100% 100% Since drop-in performance of L-41 into the R410A system showed a significant drop in mass flow rate and pressure drops, the number of circuits in the evaporator was decreased by 10% and in the condenser by 8% to increase the mass velocity for L-41. This led to increase in capacity and COP of the system due to improvements in the heat transfer. The capacity was fully recovered when the compressor displacement was increased by 13% and the number of circuits was decreased by 5% in the evaporator and by 3% in the condenser. Table 5: Positive Displacement Chiller Analysis R407C Alternatives Results Tevap Tcond P suction P discharge dp cond dp evap Mass Flow Capacity ( o C) ( o C) (kpa) (kpa) (kpa) (kpa) (kg/s) (kw) COP R407C 3.3 50.6 545.7 2173.0 70 20 1660 70.78 3.70 L-20 (Drop In) 2.9 50.8 519.9 2103.3 59.3 16.7 1332 69.84 3.70 Comparison -0.40 0.20 95.2% 96.7% 84.7% 83.5% 80.2% 99.0% 100.0% L-20 (Circuits mod.) 3.0 50.5 521.5 2093.7 71.2 19.9 1336 70.44 3.80 Comparison -0.30-0.10 95.6% 96.3% 101.7% 99.5% 80.5% 99.5% 102.7% Table 5 shows the evaluation of L-20 as replacement of R407C in a air-cooled chiller. Results show that as a drop-in replacement for R407C, L-20 has similar capacity and efficiency. Since, L-20 s flow rate is 80% of R407C, the number of circuits in the evaporator and the condenser was decreased by 5% to increase the mass velocity for L-20. This led to increase in capacity and COP of the system due to improvements in heat transfer. Re-circuiting the coils to obtain better matching of temperature profiles between air and refrigerant may lead to additional benefits for L- 20. 5. CONCLUSIONS Recently developed low global warming molecules may have potential applications in systems that currently employ low to medium pressure refrigerants, such as stationary commercial A/C systems. Our present analysis indicates that comparable performance to existing refrigerants may possibly be achieved in applications investigated in this paper without significant hardware modification. Experimental results suggest that without significant system modifications, L-20 can match the performance of R22 across the range of ambient temperatures observed in various countries in the Middle East. Hence, L-20 is a promising low global warming replacement for R22 in cooling-only systems designed to work in regions.

1670, Page 7 Theoretical results indicate that in hydronic systems, L-20 would be expected to have reasonable efficiency with an operating envelope very similar to R410A. Hence, L-20 seems to be an attractive R410A replacement in hydronic systems. Preliminary evaluations of higher pressure and medium pressure blends also show promise in positive displacement chiller applications, however there are trade-offs in performance, flammability, and GWP that need to be made. This initial work is encouraging but further work is needed to more fully explore these applications. This work would include, among other things, additional performance evaluations as well as conducting flammability risk assessments where appropriate. Nomenclature COP Coefficient of Performance T cond Condensing temperature dp cond Pressure drop in condenser T dis Compressor discharge temperature dp evap Pressure drop in evaporator TD Temperature difference between air and refrigerant saturation temperature P discharge Compressor discharge pressure T evap Evaporating temperature P suction Compressor suction pressure Critical temperature of refrigerant T crit REFERENCES [1] ISO 5151:2010(E), Non-ducted Air Conditioners and Heat Pumps Testing and Rating for Performance, 2010. [2] AHRI Standard 210/240-2008, Performance Rating of Unitary A/C and Air Source Heat Pump Equipment, Arlington, VA, 2008. [3] ASHRAE Standard 41.2, Standard Methods for Laboratory Airflow Measurements, American Society of Heating, Refrigerating and Air-Conditioning Engineers, 1992. [4] Copeland Application Engineering, AE4-1331R6 Copeland, Scroll Compressors, pp 6, February 2013 DISCLAIMER Although all statements and information contained herein are believed to be accurate and reliable, they are presented without guarantee or warranty of any kind, expressed or implied. Information provided herein does not relieve the user from the responsibility of carrying out its own tests and experiments, and the user assumes all risks and liability for use of the information and results obtained. Statements or suggestions concerning the use of materials and processes are made without representation or warranty that any such use is free of patent infringement and are not recommendations to infringe on any patents. The user should not assume that all toxicity data and safety measures are indicated herein or that other measures may not be require.