SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

Similar documents
SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000

Model 7501/7501T/7501TH/7501T240/7501T240H Portable Eyewash/Portable Eyewash with Heater

Model 7500EB Portable Eyewash with Heater

MICRO CLEANER. OPERATOR MANUAL Advance MODEL /10 Rev E Document Number

C. EWFs shall deliver the quality and quantity of water that is satisfactory for emergency washing purposes.

IMPORTANT SAFETY INSTRUCTIONS WARNING: When using electric appliances, basic

SPEAKMAN SPEAKMAN SPECIFICATIONS

Contents. Eye/Face Washes... 3 Eyewashes... 3 Swing-Away Eyewashes... 4 Eyewash/Drench Hose Units... 4 Emergency Showers... 4 Safety Stations...

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Automatic Water System Pump SERIES

Superior Spa with Aqua-Aire

Cascade Comfort Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

TRAINING BULLETIN TOOLS 1 May 27, 2011 PRESSURIZED WATER EXTINGUISHER

BRAVO! 2-STATION HANDWASH SINK Operations & Maintenance Guide

7000BT Eye/Face Washes

Model 7603/7603T/7603T240 Portable Eyewash / Portable Eyewash with Heater

Cascade Contour Bathing Systems with Aqua-Aire Safe Operation & Daily Maintenance Instructions

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

SA gal, 6 min. Flush (Eng. inst.) 19 SAM gal, 6 min. Flush (Fr. inst.) 19

optimal safety and security at the workplace International Organization for Standardization H A ISO BUFEAU VERITAS Certification

Technical Data Sheet No. JS-SM-40 DOCUMENT TITLE 2.0 LITRE STORED PRESSURE WET CHEMICAL FIRE EXTINGUISHER

3-1/2 GALLON PARTS WASHER OPERATING INSTRUCTION AND PARTS MANUAL. Model # 4KTV9

EMERGENCY EYEWASH AND SHOWER TECHNOLOGY

Instruction Manual - Anti-Siphon Ejector Chlorine & Sulfur Dioxide 500 PPD (10 kg/h) Maximum Capacity

Gray Water Capacity. Pump Capacity (per stroke) Number of Single Dispenses. NOTE: All dimensions are subject to change due to environmental factors.

Hoshizaki America, Inc.

Table of Contents ICON KEY. Quick ship icon indicates product is available for shipment within 48 hours for quantities of 4 pieces or less.

Model 8730 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Outdoor Shower and Eyewash System General Area Classification & Class I Division 2

KC22/32 SERIES Sealless Non-Metallic Centrifugal Pumps Installation and Maintenance Instructions

Beverage Ice Chests DB, DBC, FB, FBC, 1522 & 2123

Page 1 of 18. Part# /5/2013

Job Hazard Analysis Analysis by:

OWNER S MANUAL COOL MOISTURE HUMIDIFIER 1.25 GALLON (4.7 LITERS) OUTPUT PER DAY* RCM-832N. *Output dependent on room temperature and humidity.

17 GALLON PROFESSIONAL RESTROOM CLEANER

SPEAKMAN SAFETY PRODUCTS Installation Instructions SEF-TW

SELF-CONTAINED FLAKER

Emergency Showers & Eye Wash Stations

User information. Cleaning/descaling and sanitizing

Emergency Eye Wash/Shower

Model /8300CRP-8309CRP Shower & Eye/Face Wash

2001 Smith Eastern Corporation

Setup. Important. Texture Spraying (material supplied from unit)

Installation & Operating Instructions

UMA-1020 Light Weight Suspended Ceiling Kit

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

Blue Caffé P hone Fax

EMERGENCY DRENCH SHOWER

INSTALLATION INSTRUCTIONS WARRANTY

SPEAKMAN SAFETY PRODUCTS Installation, Maintenance & Operation Instructions SEF-18XY, EYESAVER FAUCET with SENSORFLOW, Battery or AC POWER

TFC 400. OPERATOR MANUAL Clarke MODEL /09 Rev C Document Number

MODEL: LSS-280

20-GALLON PARTS WASHER OWNER S MANUAL

Penner Stationary Patient Lift Safe Operation & Daily Maintenance Instructions

OPERATION AND INSTRUCTION MANUAL NORCLEAN POWERED EDDY CURRENT VACUUM RECOVERY SYSTEM WITH WATER TRAP OPTION

INDUSTRIAL - SOLVENT PARTS CLEANER CM200 (115V OR 230V PUMP)

EMERGENCY EQUIPMENT AXION MSR TM EYE WASH :: EYE/FACE WASH SHOWERS :: COMBINATION UNITS

Model /8320CRP Shower and Eye/Face Wash

Models: GW/R-T GW/R-2-T GW/R-3-T

OWNER'S SERVICE MANUAL NO INSPECTION, MAINTENANCE AND RECHARGE

TABLE OF CONTENTS FOR YOUR SAFETY

SimplyClear Pressurized Filter Product Manual

Aqua-Aire Sit-Bath System 6300 Installation / Assembly Instructions

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

HOSHIZAKI ICE DISPENSING BIN/ WATER DISPENSER MODEL DM-90A SERVICE MANUAL

Medical Equipment Washer Information & Setup

K Specifications. Max. Water Volume

4-GALLON MOBILE PARTS WASHER

Ligature Resistant Sensor Faucet Patent # US D635,386 #SAL-5011/SF370

TOP 15 :: EMERGENCY EQUIPMENT

INSTALLATION AND OPERATION. -, 3. -is INSTRUCTIONS FOR COOLAIR S EVAP-PAD COOLING SYSTEM. Coo/ah AMERICAN COOLAIR CORPORATION

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

K Specifications. Max. Water Volume

The Drink-Aide The NEW look of independence

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

MODEL: NSD10020 PACKING DIAGRAM \ _\ CARDBOARD (2) CORD COVERS AND PART--+- i----1 :ASTING POLYFOAM UMP. c=j-transformer AND L_J LIGHT

Model 8780 INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS. Tempering Skid General Area Classification & Class I Division 2. No.

SuperKlean Washdown Products

PolyMax H2-24 Dutch Bucket System

Industrial - Remote Reservoir Parts Cleaner Operator's Manual. Read and understand all labels, MSDS, and this instruction manual before use.

INSTALLATION AND INSTRUCTION MANUAL

Model SD2318. Stainless Steel Kitchen Sink INSTALLATION INSTRUCTIONS DIMENSIONS FEATURES

Iron Air Charge MangOx 2510 SXT Installation & Start Up Guide

CBT LW MAINTENANCE GUIDE

Important Safeguards (For your safety, please follow the instructions below.) Specification. Warning. Thermal mixing valve faucet.

I N ST R UC T I ON MODEL 2612 & 2712 SLICERS MODELS 2612 ML ML FORM (12-98) 2612 SLICER

BioMaster 250/350/600 BioMaster Thermo 250/350/600

Installation Instructions for. WaterMaster Series Fountains

Installation Instructions for. WaterMaster Series Fountains

RiteTemp. Evaporative Cooler. Information Brochure (internal) RiteTemp. RiteTemp. Date: 03/30/05. Cool-Air 5051

Upholstery and Drapery Cleaner. Operator and Parts Manual. Model No.: gal Extractor. MNL32506 Rev. 00 (08-98)

AN AXION TM EYEWASH...

PART # FOR PARTS SEE PAGE 4-2, 4-3

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

S19314 Series. Combination Drench Shower and Halo Eyewash or Eye/Face Wash. Recommended Option:

EVAPORATIVE AIR COOLER SERVICE MANUAL

TR Shower Panel. Operating manual. Hygiene Equipment Designed for People. Serial Number:

American Hydro Systems

F-CLASS MODEL M6L WET CHEMICAL FIRE EXTINGUISHER Installation, Operation, Recharge and Maintenance Manual

FAILURE TO ADHERE TO THESE WARNINGS CAN RESULT IN FIRE, SERIOUS INJURY, ELECTRICAL SHOCK AND/OR DEATH. Technical Service

Reliability is a beautiful thing TM MODULAR FLAKER F-800MAH(-C) F-800MWH(-C) INSTRUCTION MANUAL

Transcription:

SPEAKMAN GRAVITYFLO PORTABLE EYEWASH SE-4000 TM INSTALLATION AND OWNER S MANUAL C O N T E N T S I. Introduction II. Product Dimensions III. Installation IV. Operation in Emergency Situation V. Periodic Cleaning & Maintenance VI. Replacements Parts KEEP THIS MANUAL WITH EMERGENCY FIXTURE U.S. Patent No. 5,216,765 Meets ANSI Z358.1 for portable eye wash units and ANSI A117.1-2003 for barrier free design

I. INTRODUCTION SE-4000 GRAVITYFLO by Speakman s GRAVITYFLO Eyewash is an engineering triumph. Ergonomically designed and barrier-free, the GRAVITYFLO reservoir body is one-piece molded from light, durable, high-density polyethylene. Its bright blue color provides high visibility during an emergency. Unique, high efficiency spray heads of contoured rubber give through eye and face coverage. The quick opening, reliable value is representative of Speakman s commitment to excellence. The graceful design incorporates an easy-carry molded-in handle grip. GRAVITYFLO is ideally suited for use in a variety of Locations: industrial plants, laboratories, or at any site Without a portable or permanent plumbed-in water source. GRAVITYFLO can also be used as a temporary back-up device for plumbed-in stations which are temporarily out of service. Additionally, this unit can be used for first aid while in transit to a hospital during emergency situations. Speakman s GRAVITYFLO Eyewash is designed to exceed the ANSI recommended flow for a portable eyewash. Model SE-4000 makes emergency protection instantly available when required. CAUTION: This Eyewash container should only be used with portable water and/or Eyewash solutions intended for portable units. II. PRODUCT DIMENSIONS Capacity: 16-21 (US) gallons portable water. Meets ANSI Z358.1 for portable eyewash units. All dimensions +/- 1/4", and subject to change without Notice.

III. INSTALLATION READ THIS SECTION COMPLETELY BEFORE INSTALLING The following is a step-by-step sequence of how to install and maintain your Speakman SE-4000 GRAVITYFLO Eyewash. The SE-4000 comes complete with: FIG. 1 NOTE: Tubular bracket can also be mounted flush to wall surface, providing adequate reinforcement and wall supports are installed. Spacer block not required when flush mount installation is chosen. Caution: The Eyewash SE-4000 weighs approximately 185 lbs. When filled with 21 gallons of water. A clear area at each Eyewash station should be at least 48 by 48 and should allow either a forward or parallel approach by a person using a wheelchair. (See Fig. No. 3) IMPORTANT: When fastening or mounting the SE-4000 to a wall, make sure that the wall construction is suitable to hold a vertical load of 300 lbs. The SE-4000 comes complete with a tubular wall bracket and hardware to mount the bracket. The tubular bracket must be fastened securely to the wall studs as shown in Fig. No. 1. Where concrete or other composition wall constructions are involved, consult a building contractor for the correct fastening and mounting hardware to install the tubular wall bracket. Installation height for the SE-4000 should be 33 to 45 from floor to eyewash spray heads (to meet ANSI Z358.1). See Fig. No. 2. 3. Position tubular wall bracket as shown in Fig. No. 1 and secure with four (4) 1/4" lag screws provided. When drilling into tile, masonry, concrete, or other hard materials, wear safety goggles to prevent eye injuries. 4. Insert SE-4000 down into the tubular wall bracket as shown in Fig. No. 2. Make sure that overhangs on left and right hand side of plastic Eyewash container rest securely on tubular side arms. 1. Clean inside of tank and flush system with clean water. Rinse thoroughly. (For periodic cleaning and maintenance see Section V of this manual.) FIG. 2 2. Select a suitable location. Do not allow your GRAVITYFLO product to freeze or become overheated. We recommend the emergency Eyewash unit be in an accessible location that requires no more than 10 seconds to reach and within a travel distance of no more than 100 ft. from the hazard (to meet ANSI Z358.1). The area around the Eyewash should be well-lighted. *NOTE: Where physically challenged people in wheelchairs use this product it may be necessary to lower the installation height to between 32 and 34 for ease of use.

FILLING INSTRUCTIONS FIG. 3 1. The SE-4000 has a total fill capacity of 21 US gallons for maximum performance. In the interest of safety, Speakman Company recommends that the unit be filled to capacity of 21 US gallons at all times. For a more detailed understanding of fill capacity and gallons per minute flow see Chart Figure No.5 2. Start with a clean eyewash container. 3. Fill the eyewash tank with 21 gallons of clean, potable water. 4. When measuring depth level of fluid in tank, measure from the neck of the tank and refer to the Eyewash chart for desired information. See Fig. No. 5. 5. Install drain plug and fill unit to desired capacity. (See Filling Instructions) 6. Pull down on rubber hand grip to insure water flows to Eyewash heads. Return to closed vertical position. 7. Date and replace Testing Record Tag and affix Tamper Evident Tie to the small plastic clip fastened to the top cap of the SE-4000. See Fig. No. 4. 5. Speakman also provides an optional Fluid Level Cap Gauge (SE-4200). This gauge allows the service maintenance engineer to quickly see the number of gallons of flushing fluid in the tank. It also assists during filling and mixing of eyewash solution. FOR INFORMATION ON THE FOLLOWING SEE FIG. No. 5: a) Running time in minutes b) Volume of tank in US gallons c) Functional performance of Eyewash d) Weight of product in Ibs. FIG. 4 For Eyewash solutions, see Section V of manual. FIG. 5

IV. OPERATION WARNING: THIS EMERGENCY PRODUCT IS INTENDED ONLY FOR EMERGENCY FIRST AID FOR VICTIMS OF FLUID CHEMICAL OR SMALL SOFT PARTICULATE MATTER. THE VICTIM SHOULD SEEK QUALIFIED MEDICAL TREATMENT AS QUICKLY AS POSSIBLE. IT SHOULD BE NOTED THAT THE GRAVITYFLO EMERGENCY EYEWASH SHOULD NOT BE CONSIDERED A SUBSTITUTE FOR PRIMARY PROTECTIVE DEVICES. PERSONAL PROTECTIVE EQUIPMENT SHOULD BE WORN AS A DEFENCE AGAINST BOTH FLYING PARTICLES AND SPLASHING OF INJURIOUS LIQUIDS. IMPORTANT: The more quickly the victim can flush the eyes, the less risk there will be of eye injury. Seconds can make the difference in preventing serious eye of face injury. Instruct all employees in use of this emergency Eyewash unit to test weekly and make sure a minimum of 16 gallons of flushing fluids is in the tank. An individual should be assigned to check eyewash liquid level daily. All employees or potential users of this Eyewash should be reminded that this unit is for emergency use only; tampering with the unit or using it for nonemergency purposes may cause the unit to be empty when needed. 1. Pull down spray arms and lower face into stream of water solution. 2. Using thumbs and forefingers, hold eye lids open to allow affected tissue full exposure. Flush eyes for a minimum of 15 minutes. An injured person may require assistance in holding eye lids open. 3. Seek medical attention immediately. V. PERIODIC CLEANING & MAINTENANCE The Speakman GRAVITYFLO Portable Eyewash has been designed for years of trouble-free service. It is critical to keep this unit clean at all times. Daily Cleaning (Portable Water Solution) It may be necessary under certain conditions to replace the portable water on a daily basis where quality of water is suspect of where excessive Hot/Cold water temperature changes occur. Empty unit by removing side plug or allow water to run from spray heads by activating the valve. Another alternative is to siphon water with a hose. Weekly Cleaning & Disinfecting (Potable Water Solution) Add 1/2 cup (4 fl. oz.) of Clorox (liquid bleach) to the 21 gallons of potable water and mix thoroughly. Allow Clorox/water mixture to sit for 15 minutes, drain contents, and rinse several times thoroughly with clean potable water. This procedure will disinfect and clean the inside of the tank. Finally, refill the Eye/Face Wash container with clean potable water. A high pressure spray nozzle can also be used to clean the inside of tank, if necessary. For further information on Clorox, call them tollfree at 1-800-292-2200. Reminder Speakman Company recommends weekly testing for optimum performance and recording of results for maximum efficiency. Several test record tags are provided for this purpose. Cleaning Rubber Eye Guard Assembly Unscrew rubber eye guard assembly from threaded rubber arm grip using a counter-clockwise motion. During cleaning, seal threaded arms with plastic caps provided. Push back on rubber eye guard and remove spray head. Twist turn cap and base to disassemble. Scrub all components clean with hot soapy water and rinse thoroughly. Reassemble and replace on unit. Test water flow to be sure unit is operational. Important: Self-contained eyewash equipment shall be visually checked frequently to determine if flushing fluid needs to be changed or supplemented. Frequency of these inspections is dependent on environment conditions, but at a minimum weekly. Failure to conduct visual checks could lead to further injury.- Customer shall take precautions to help prevent the growth of potentially harmful bacteria in eyewash tanks. Either of the following procedures is recommended. Procedure 1: Use suitable Bacteriostatic preservative to help prevent growth of bacteria in eyewash tank. Eyewash tank should be drained, flushed and refilled with clean potable water and Bacteriostatic preservative added as directed by the preservative s manufacturer. Procedure 2: Drain, flush and refill units with clean potable water at least once every week unless site conditions require more frequent changing. Thoroughly cleanse tank at least once every month. See cleaning instructions for further information of cleaning unit.

VI. REPLACEMENT Part No. RPG07-0089 Cap Standard Description SE-4200 RPG38-0347 RPG20-1894 RPG05-0660 Cap Gauge level indicator Spray head assembly Complete valve Supply tube, Connector, and In-Line Strainer RPG99-0095 Tamper evident ties (pkg of 10) RPG99-0094 Test record tag (pkg of 10) TESTING RECORD EYE/FACE WASH DATE INITIALS DATE INITIALS DATE INITIALS DATE INITIALS SPEAKMAN PO Box 191 Wilmington, DE 19899 Phone: 800-537-2107 Fax: 800-977-2747 Visit us on the web at www.speakmancompany.com 92-0410 REV.-4 07-25-14