Classifying Forced Outages Transmission Maintenance Procedure No. 5

Similar documents
TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing

A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing

Standard PRC Protection System Misoperation Identification and Correction

TRANSMISSION ENGINEERING STANDARDS SUBSTATIONS

Community Wildfire Safety Program. June 26, 2018

A. Introduction 1. Title: Transmission and Generation Protection System Maintenance and Testing

Standard PRC Protection System Misoperation Identification and Correction

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

FACILITIES PLANNED UTILITY OUTAGES POLICY

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Appendix B. FRCC regional application of the term transmission Protection Systems

TECHNICAL SPECIFICATION

Standard PRC-005-4(X) Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

Standard PRC 004 5(i) Protection System Misoperation Identification and Correction

Improvements in Transmission Control Center Alarm Management Practices

CAN/ULC-S1001, INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION & LIFE SAFETY SYSTEMS Simon Crosby, LEL, CET, CFPS October 21, 2015

Standard PRC-005-3(i) Protection System and Automatic Reclosing Maintenance

UNDERSTANDING ELECTRICAL SAFETY RISKS

Standard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

PRC (I) August 9, Authored by

Standard PRC Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

STCP 02-1 Issue 005 Alarm & Event Management

Emergency Action Plan

Planned, Limited Notice and Emergency Outage Guidelines

Standard PRC-005-X Protection System, Automatic Reclosing, and Sudden Pressure Relaying Maintenance

CONNECTION, ENERGISING, COMMISSIONING AND PERMANENT DISCONNECTION OF HIGH VOLTAGE APPARATUS

Preliminary Operations and Maintenance Plan Baron Winds Project

TECHNICAL REPORT IEC TR 62987

TELECOMMUNICATION EQUIPMENT LOCATED IN THE VICINITY OF PROPOSED DISTRIBUTION HV EARTHS

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

SCHEDULE 2 - EXHIBIT 1 DATED [ ] NATIONAL GRID ELECTRICITY TRANSMISSION PLC (1) and THE CONNECTION AND USE OF SYSTEM CODE

EMERGENCY PREPAREDNESS & RESPONSE PROCEDURE

Australian/New Zealand Standard

This is a preview - click here to buy the full publication

Staff Report and Recommendation

Fire System Impairment Policy

Policy and Specification for the Interface with Independent Distribution Network Operators Installations

National Grid / DG Installation Process Guide per NY SIR / July 2011 ver. 1.0

Australian/New Zealand Standard

Scope of Section 2. AS vs. Application Issues. Schedules & Log- Contents. Books

Fire Prevention Plan Program

4. Applicability: 4.1. Functional Entities: 4.2. Facilities:

4. Applicability: 4.1. Functional Entities: 4.2. Facilities: 5. Effective Date: See Implementation Plan

TABLE OF CONTENTS CHAPTER 5 SPECIAL OCCUPANCIES CHAPTER 1 GENERAL RULES... 19

WILDLIFE AND ASSET PROTECTION PRODUCTS

Standard PRC-005-3(X) Protection System and Automatic Reclosing Maintenance

National Grid / Supplement to Specifications for Electrical Installations / ESB ver Doc. File: ESB _ver3_

Case Study. A Geothermal Energy Generation Facility Embraces Infrared. Polymer Window Inspections. Overview: iriss.com

Appendix U.1 Bushfire Management Plan September 2011

Fire Protection System Impairment Procedure

UC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION

Implementing an Energized Electrical Work Program. SESHA Hill Country Chapter. Brett Jay Davis, PE Zephyr Environmental Corporation

INTERNATIONAL STANDARD

UNIVERSITY. Facilities Management

Research for the Development of Safety Standards

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

INTERNATIONAL STANDARD

What Utility Analytics means to Exelon

Distribution Control Center Operator Training

Supplementary Reference & FAQ. Draft

POWER SYSTEM INCIDENT REPORT: TRIP OF DOUBLE CIRCUIT MACKAY- COLLINSVILLE TEE - PROSERPINE 132 KV LINES AND STRATHMORE SVC ON 29 DECEMBER 2010

Supplementary Reference and FAQ

Luminaires Part 2-4: Particular requirements Portable general purpose luminaires

I. Scope: II. Environmental Health and Safety Fire Alarm System Impairment Program - Guideline Revision Date: April, 2018

PERFORMANCE METRICS FOR SAFE LASER OPERATIONS AT SLAC NATIONAL ACCELERATOR LABORATORY 1 Paper # 203

June 4, 2014 VIA ELECTRONIC FILING. Ms. Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, D.C.

Radiation Emitting Devices Research X-ray Safety Program

New York s Electric Reliability Monitoring Utility Performance

Supplementary Reference and FAQ - Draft

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

Fire Sprinklers Working Group Final Report

DONALD H. BERG, ARCHITECT

Application Note on Reading the Vigilohm IM400 Insulation Monitoring Device Installed in Conext Core XC and XC-NA Series Inverters

Monitoring of Electrical Equipment Failure Indicators and Alarming

Continuous, real-time detection, alarming and analysis of partial discharge events

Electrical Safety Program

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

ISO INTERNATIONAL STANDARD. Earth-moving machinery Field of vision of surveillance and rear-view mirrors Part 2: Performance criteria

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Chapter 1 General...9 Article 100 Definitions...11 Article 100 Questions Article 110 Requirements for Electrical Installations...

4. Applicability: 4.1. Functional Entities: 4.2. Facilities: 5. Effective Date: See Implementation Plan

Electrical Safety Compliance: NFPA 70E

NY LCC Data Specification

AS 2419 OVERVIEW OF PROPOSED CHANGES. Gary Nenadovich Director G N Consulting

IMO. Resolution A.951(23) Adopted on 5 December 2003 (Agenda item 17) IMPROVED GUIDELINES FOR MARINE PORTABLE FIRE EXTINGUISHERS

TECHNICAL REPORT IEC TR Electronic display devices Part 3-2: Evaluation of optical characteristics Mura. colour inside. Edition 1.

PART 8 - Miscellaneous Services 3rd Revised Sheet 1 SECTION 8 - Other Miscellaneous Services Replacing 2nd Revised Sheet 1

Australian Standard. Water mist fire protection systems System design, installation and commissioning AS

INTERNATIONAL STANDARD

PART 4 ELECTRICAL STANDARDS

ELECTRICAL BULLETIN

Town of Cochrane Policy

Australian/New Zealand Standard

INTERNATIONAL STANDARD

ORDINANCE NO. Establishing Fire and Life Safety Requirements for Existing Multi-Family Residential Buildings Classified as Group R, Division Occupancy

Noblesville Alternative Transportation Plan 2015

Australian/New Zealand Standard

Enclosures Appendix 1: Draft Golders Green Station Planning Brief. Summary

Transcription:

Classifying Forced s Transmission Maintenance Procedure No. 5 Version 4 Effective Date 10/17/2017 Approved by: Transmission Maintenance Coordination Committee 10/17/2017 CAISO Public

Classifying Forced s REVISION HISTORY VERSION NO. APPROVED DATE EFFECTIVE DATE REVISED BY DESCRIPTION 1.0 9/7/2000 9/7/2000 TMCC Procedure Adopted 2.0 7/21/2005 7/21/2005 TMCC Revised to align with TCA Appendix C rewrite in 2004 3.0 1/24/2014 1/24/2014 TMCC Updated Table 1 bullets No. 8 and 9 to reflect TMCC approval of revised availability metric streamline method. 4.0 10/17/2017 10/17/2017 TMCC Updated company logo and revised format to align with corporate standard Grid Assets CAISO Public Revision History

Classifying Forced s TABLE OF CONTENTS 5.1 PURPOSE... 1 5.2 SCOPE... 1 5.3 SAFETY... 1 5.4 DESCRIPTION CLASSIFICATIONS... 2 5.6 CONTACTS... 2 Grid Assets CAISO Public Table of Contents

Classifying Forced s 5.1 PURPOSE This procedure supports efforts to accurately interpret and report Forced (IMS) data used to calculate Availability Measures as described in Appendix C. 5.2 SCOPE To accurately calculate Availability Measures, Appendix C definitions must be applied. Unlike Appendix D, Appendix C classifies an event as an (IMS) if it interrupts power flow between terminals. This distinction is significant because Appendix C definitions properly reduce the number of events classified as Forced s (IMS). For example, a Station (IMS) may still be recorded as a Forced (IMS), but, it shouldn t be recorded as a Transmission Line Circuit Forced (IMS) unless the event actually interrupts power flow in the associated Transmission Line Circuit. Similarly, when a piece of equipment is taken out of service, either scheduled or unscheduled, this event is not considered an (IMS) for the purposes of calculating Availability Measures, provided it does not interrupt the flow of power between terminals 5.3 SAFETY The ISO and PTOs want to encourage the safe operation of the ISO grid. Therefore, it is their intention to encourage safe work practices. The concern of reducing the number of Forced s (IMS) should not affect the safety of personnel or the general public. Grid Assets CAISO Public Page 1

Classifying Forced s 5.4 DESCRIPTION CLASSIFICATIONS Table 1 illustrates some common events and indicates how each should be classified when preparing Availability Measures reports. Table 1 Examples of Classification for Common Events No. Description Classification 1 Request for cutout on a reclosing relay. 2 Circuit breakers, switches and buses taken out of service, provided power flow can be maintained between Line terminals. 3 Line Section is in outage condition with one breaker energized and not part of the clearance. Terminal with this breaker was de-energized, provided no power was flowing through it. 4 Transmission Line Circuit terminates into a series transformer and transformer experiences an outage that interrupts power flow. 5 PTOs RAS causes outage condition on its Transmission Line Circuits. 6 Line Section is in outage condition and ISO determines request for extension to last approved return date/time will compromise only grid reliability. 7 Line Section is in outage condition and ISO determines request for extension to last approved return date/time impacts safety or will not compromise grid reliability. 8 Late notification on Transmission Line Circuit outage request and the request does not impact safety. 9 Late notification on Transmission Line Circuit outage request and the request impacts safety. Forced Forced Forced Forced 5.6 CONTACTS For questions regarding subject matter covered in this procedure, please contact the Director of Grid Assets, California ISO. Grid Assets CAISO Public Page 2