Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use DLC proposes to include non-cutoff and semi-cutoff (or "open face") wall packs in the Technical Requirements Table under a new primary use. The requirements for this primary use will be similar to the existing Outdoor Wall-Mounted Area Luminaires primary use, with the exception of the full-cutoff requirement, with how the light output, efficacy, and ZLD requirements are evaluated. The luminaire shall be tested in the correct orientation according to its intended use. Efficacy will be evaluated by calculating the "Zonal Lumen Efficacy" by dividing the number of lumens in the 0-90 range by the watts consumed by the luminaire. This primary use will require a "zonal efficacy" consistent with the category requirements. The lumen and ZLD metrics will also be evaluated against only the lumens in the 0-90 zone. In addition, we will rename the current Outdoor Wall-mounted Area Luminaires category to Outdoor Full-Cutoff Wall-mounted Area Luminaires to distinguish between the two primary uses. The requirements for this primary use will be identical to the requirements for the existing Outdoor Wall-mounted Area Luminaires primary use. Please see the following pages for: 1. The Technical Requirements Table, V3.1 for Luminaires Page 2 2. Technical Requirements Table V3.1 Definitions Page 3 3. Primary Use Technical Requirements: Light Output and Zonal Lumen Distribution Page 5 DLC QPL TRT V3.1 Non-Cutoff and Semi-Cutoff Outdoor Wall-Mounted Area Luminaires DRAFT PROPOSAL Page 1 of 8
# Category 1 2 3 4 5 Outdoor 1. Technical Requirements Table, V3.1 - Technical Requirements: Luminaires General Application Outdoor Low Output Outdoor Mid Output Outdoor High Output Interior Directional Light Output (lm) Efficacy (lm/w) 250-5,000 65 5,000-10,000 DLC Standard Warranty (years) CCT / CRI / L 70 70 5700 / 5 65 / 105 50,000 DLC Premium* CCT / CRI / Efficacy Warranty L (lm/w) (years) 90 /L 70 100 10,000 75 110 250-4,500 45 5000 / 80 / 50,000 6 Troffer 1,500 85 110 Indoor 5 7 Display Case Linear Ambient 50-375 lm/ft 8 High-Bay 5,000 80 75 50 85 375 lm/ft 85 110 5700 / 70 50,000 110 Primary Use** DLC QPL TRT V3.1 Non-Cutoff and Semi-Cutoff Outdoor Wall-Mounted Area Luminaires DRAFT PROPOSAL Page 2 of 8 5 5 5700 / 65 / >36,000 / 50,000 5000 / 80 / >36,000 / 50,000 5700 / 70 / >36,000 / 50,000 Outdoor Pole/Arm-mounted Area and Roadway Luminaires Outdoor Pole/Arm-mounted Decorative Luminaires Outdoor Full-Cutoff Wall-mounted Area Luminaires Outdoor Non-cutoff and Semi-Cutoff Wall-mounted Area Luminaires Bollards Parking Garage Luminaires Fuel Pump Canopy Luminaires Landscape/Accent Flood and Spot Luminaires Architectural Flood and Spot Luminaires Stairwell and Passageway Luminaires Wall-wash Luminaires Track or Mono-point Luminaires Display Case Luminaires Horizontal Refrigerated Case Luminaires Vertical Refrigerated Case Luminaires 2x2 Luminaires for Ambient Lighting of Interior 1x4 Luminaires for Ambient Lighting of Interior 2x4 Luminaires for Ambient Lighting of Interior Direct Linear Ambient Luminaires Linear Ambient Luminaires w/ Indirect component High-bay Luminaires for Commercial and Industrial Buildings Low-bay Luminaires for Commercial and Industrial Buildings High-bay Aisle Luminaires Distribution See Primary Use Zonal Lumen Density Requirements below
2. Technical Requirements Table V3.1 Definitions This document summarizes the definitional changes that are part of the Technical Requirements Table V3.0. These definitions can also be found at http://www.designlights.org/content/qpl/productsubmit/categorydefinitions. Primary Use Designation Definitions: Outdoor Pole/Arm-Mounted Area and Roadway Luminaires. Typical street lights, parking lot lights. May be cobra-head shaped, shoebox, etc. Outdoor Pole/Arm-Mounted Decorative Luminaires. Commonly, in-town street lights, may be acorn-shaped, etc. Outdoor Full-Cutoff Wall-Mounted Area Luminaires. Typically walkway or security lights, affixed to building wall. May be box-shaped. Must have no up-light. Outdoor Non-cutoff and Semi-Cutoff Wall-Mounted Area Luminaires. Typically walkway or security lights, affixed to building wall. May be box-shaped. Up-light is allowed. Bollards. Architectural outdoor lighting fixtures comprising short, upright ground-mounted units, typically giving off light from the top or the sides, and used to illuminate walkways, steps, or pathways. Parking Garage Luminaires. Ceiling-mounted luminaires for use in parking garages. Fuel Pump Canopy Luminaires. Ceiling-mounted luminaires for use outdoors or in locations open to elements in gas station canopies. Landscape/Accent Flood and Spot Luminaires. Small, low-lumen, directional luminaires intended to highlight objects and areas in outdoor lighting. Manufacturers must follow NEMA guidelines for declaring beam spread. Architectural Flood and Spot Luminaires. Aimable, directional luminaires intended to highlight objects or building facades in outdoor lighting. Manufacturers must follow NEMA guidelines for declaring beam spread. Category is not intended for luminaires designed to light areas. Stairwell/Passageway Luminaires. Corner- or surface-mounted luminaires that provide lighting in stairwells and passageways. Luminaires must meet one of the following conditions: include integral controls, operate off of remote sensors where remote sensor is packaged together with the luminaire under a single model number, or be designed to operate off of remote sensors, where the luminaire and sensors are sold separately, but the luminaire has features enabling communication with a remote sensor. Controls must assure the luminaire reverts to lower-power, lower-light output state when there are no occupants in the vicinity. Wall-Wash Luminaires. Luminaires designed to illuminate walls in interior spaces. Track or Mono-Point Directional Luminaires. Usually ceiling-mounted tracks or fixed single head. Adjustable aim "cans". Complete LED fixtures (not replacement lamps in existing cans such as PAR 38 or MR16 lamps). Vertical Refrigerated Case Luminaires. Strip lights in refrigerator cases, vertically mounted along refrigerator case door mullions. Category covers only complete luminaires, with all necessary components, including specific driver/power supply. Replacement lamps are not currently eligible under this category. DLC QPL TRT V3.1 Non-Cutoff and Semi-Cutoff Outdoor Wall-Mounted Area Luminaires DRAFT PROPOSAL Page 3 of 8
Horizontal Refrigerated Case Luminaires. Strip lights in refrigerator cases, horizontally mounted along refrigerator case shelves or canopies. Category covers only complete luminaires, with all necessary components, including specific driver/power supply. Replacement lamps are not currently eligible under this category. Display Case Luminaires. Strip lights. Usually mounted horizontally at frame edges of glass case. Replacement lamps such as MR16 or PAR 38 lamps are not eligible. 1x4, 2x2, and 2x4 Luminaires for Ambient Lighting of Interior. Common recessed, suspended, or surfacemounted fixtures intended to provide ambient lighting in settings such as office spaces, schools, retail stores, and other commercial environments. Products submitted in these categories must meet the stated form factors with a tolerance of ±4 inches. Direct Linear Ambient Luminaires. Suspended-, surface- or recessed-mounted linear luminaires, no wider than 12", designed to provide direct ambient lighting in indoor spaces. Products may be designed to be installed end-to-end to create long chains. Utilitarian "strip" style fixtures are also eligible under this category. Products intended specifically for cove lighting are not currently eligible under this category. Linear Ambient Luminaires with Indirect Component. Suspended-mounted luminaires or recessed luminaires, no wider than 12", designed to provide ambient lighting in indoor spaces, including an intentional lighting component that is indirect. Products may be designed to be installed end-to-end to create long chains, and may be described as indirect, semi-direct, semi-indirect, direct-indirect, indirect-direct, or general ambient, depending on intended lighting distribution. Utilitarian "strip" style fixtures are not eligible under this category. Products intended for cove lighting are not currently eligible under this category. High-Bay Luminaires for Commercial and Industrial Buildings. Pendant or surface-mounted fixtures specific for indoor high ceiling spaces (intended for ceilings 25'). Low-Bay Luminaires for Commercial and Industrial Buildings. Pendant or surface-mounted fixtures specific for indoor ceiling spaces (intended for <25'). High-Bay Aisle Luminaires for Commercial and Industrial Buildings. Pendant or surface-mounted fixtures specific for indoor high ceiling spaces (intended for ceilings 25'), in locations that require lighting of aisles. Retrofit Kits for Outdoor Pole/Arm-Mounted Area and Roadway Luminaires. Integrated-style kits that replace all reflectors and optical systems of existing luminaires. Screw-in "lamps" intended as HID replacements are not eligible at this time. Retrofit Kits for Outdoor Pole/Arm-Mounted Decorative Luminaires. Integrated-style kits that replace all reflectors and optical systems of existing luminaires. Screw-in "lamps" intended as HID replacements are not elgible at this time. Retrofit Kits for Large Outdoor Pole/Arm-Mounted Area and Roadway Luminaires. Integrated-style kits that replace all reflectors and optical systems of existing luminaires. Screw-in "lamps" intended as HID replacements are not eligible at this time. Retrofit Kits for Outdoor Wall-Mounted Luminaires. Integrated-style kits that replace all reflectors and optical systems of existing luminaires. Screw-in "lamps" intended as HID replacements are not eligible at this time. Retrofit Kits for Parking Garage Luminaires. Integrated-style kits that replace all reflectors and optical systems of existing luminaires. Screw-in "lamps" intended as HID replacements are not eligible at this time. DLC QPL TRT V3.1 Non-Cutoff and Semi-Cutoff Outdoor Wall-Mounted Area Luminaires DRAFT PROPOSAL Page 4 of 8
Retrofit Kits for Fuel Pump Canopy Luminaires. Integrated-style kits that replace all reflectors and optical systems of existing luminaires. Screw-in "lamps" intended as HID replacements are not eligible at this time. Integrated-Style Retrofit Kits for 2x2, 1x4, and 2x4 Luminaires for Ambient Lighting of Interior. Troffer retrofit kits that replace all reflectors and optical systems of the existing luminaire, effectively creating a completely new luminaire. Linear-Style Retrofit Kits for 2x2, 1x4, and 2x4 Luminaires for Ambient Lighting of Interior. Tube-shaped or strip-style retrofit kits for troffers. Products in this category do not replace the optical systems of the existing luminaire, and leave the basic form of the existing luminaire intact. Retrofit Kits for High-Bay Luminaires for Commercial and Industrial Buildings. Integrated-style kits that replace all reflectors and optical systems of existing luminaires. Screw-in "lamps" intended as HID replacements are not eligible at this time. Retrofit Kits for Low-Bay Luminaires for Commercial and Industrial Buildings. Integrated-style kits that replace all reflectors and optical systems of existing luminaires. Screw-in "lamps" intended as HID replacements are not eligible at this time. Replacement Lamps ( plug and play ) (UL Type A). Four- and two-foot tubes ; designed to replace four- or two-foot fluorescent lamps, respectively. Products in this category employ lamp holders to connect to the fixture being retrofitted and are designed to be plug and play replacements for fluorescent lamps. That is, products in this category can operate off the existing fluorescent ballast, and do not require mechanical or electrical changes to the fixture. Note that due to testing considerations, at this time only products that can operate off electronic instant start ballasts are eligible. Replacement lamps designed to operate off existing magnetic ballasts, or off other types of electronic ballasts, are not eligible. (see Replacement Lamps page for more detail on testing requirements) Internal-driver/Line Voltage Lamp-Style Retrofit Kits (UL Type B). Four- and two-foot tubes designed to replace four- or two-foot fluorescent lamps, respectively. Products in this category employ lamp holders to connect to the fixture being retrofitted, but do not operate off the existing fluorescent ballast. These products require rewiring of the existing fixture to bypass the ballast and send line voltage directly to the lamp holders. (see Replacement Lamps page for more detail on testing requirements) NOTE** Internally-driven lamps that can operate either off a fluorescent ballast or off line-voltage will be denoted as Dual Mode on the QPL. Products must be tested under worst-case operating condition. External-driver Lamp-Style Retrofit Kits (UL Type C). Four- and two-foot tubes designed to replace four- or two-foot fluorescent lamps, respectively. Products in this category employ lamp holders to connect to the fixture being retrofitted, do not operate off the existing fluorescent ballast, and require rewiring of the existing fixture to replace the ballast with an external driver. The lamp holders are then wired to receive only the low-voltage electricity that is supplied by that external driver. Note that due to testing considerations, only one- or two-lamp four-foot lamp systems, or one- and three-lamp two-foot lamp systems are eligible. Development of provisions for systems with alternative numbers of lamps operating off single drivers is under consideration. (see Replacement Lamps page for more detail on testing requirements) Dual Mode Internal Driver (UL Type A and Type B). Four- and two-foot tubes designed to replace four- or two-foot fluorescent lamps, respectively. Products in this category have the ability to operate off the existing fluorescent ballast and also have the ability to operate off of line voltage if the troffer is rewired to bypass the ballast. These products connect to the troffer using standard pinbase connections to the lamp holders. Note that at this time only products that can operate off electronic instant start ballasts are eligible. Products that are designed to operate off magnetic or non-instant start electronic ballasts are not eligible. (see Replacement Lamps page for more detail on testing requirements) DLC QPL TRT V3.1 Non-Cutoff and Semi-Cutoff Outdoor Wall-Mounted Area Luminaires DRAFT PROPOSAL Page 5 of 8
3. Primary Use Technical Requirements: Light Output and Zonal Lumen Distribution Table 4: Primary Use Requirements Primary Use Letter Primary Use Designation Light Output (lm) Zone/Spacing Criteria Nominal Requiremen t Requirement with a Outdoor Pole/Arm-mounted Area and Roadway 0-90º 100% -1% 99% 1,000 Luminaires 80-90º 10% +3% 13% b Outdoor Pole/Arm-mounted Decorative Luminaires 1,000 0-90º 65% -3% 62% c Outdoor Full-Cutoff Wall-mounted Area Luminaires 300 0-90º 100% -3% 97% 80-90º 10% +3% 13% * Outdoor Non-cutoff and Semi-Cutoff Wall-mounted Area Luminaires 300* 80-90º* 10% +3% 13% d Bollards 500 90-110º 15% +3% 18% >110º 0% +3% 3% e Parking Garage Luminaires 2,000 60-80º 30% -3% 27% 70-80º 25% +3% 28% f Fuel Pump Canopy Luminaires 2,000 0-40º 40% -3% 37% 40-70º 40% -3% 37% g Landscape/Accent Flood and Spot Luminaires 250 (<1,000) 0-90º 85% -3% 82% h Architectural Flood and Spot Luminaires 1,000 0-90º 85% -3% 82% i Stairwell and Passageway Luminaires 750 0-90º 85%**** -3% 82% j Wall-wash Luminaires 575 0-90 60%*** -3% 57% k Track or Mono-point Directional Luminaires 250 0-90º 85% -3% 82% l Vertical Refrigerated Case Luminaires-center** 100 lm/ft 10-90º 95% -3% 92% m Vertical Refrigerated Case Luminaires-end*** 50 lm/ft 10-90º 95% -5% 90% n Horizontal Refrigerated Case Luminaires 100 lm/ft 0-90º 95% -3% 92% o Display Case Luminaires 50 lm/ft 0-80º 95% -5% 90% p 2x2 Luminaires for Ambient Lighting of Interior 2,000 DLC QPL TRT V3.1 Non-Cutoff and Semi-Cutoff Outdoor Wall-Mounted Area Luminaires DRAFT PROPOSAL Page 6 of 8
Primary Use Letter q r s t u v Primary Use Designation 1x4 Luminaires for Ambient Lighting of Interior 2x4 Luminaires for Ambient Lighting of Interior Light Output (lm) 1,500 3,000 Zone/Spacing Criteria Nominal Requiremen t Requirement with Linear Ambient Luminaires w/ Indirect Component 500 lm/ft 90-150 35% -3% 32% Direct Linear Ambient Luminaires 375 lm/ft 0-60 40% -3% 37% High-bay Luminaires for Commercial and Industrial Buildings Low-bay Luminaires for Commercial and Industrial Buildings 10,000 20-50º 30% -10% 20% 5,000 (<10,000) w High-bay Aisle Luminaires 10,000 y z aa ab Retrofit Kits for Outdoor Pole/Arm-mounted Area and Roadway Luminaires Retrofit Kits for Outdoor Pole/Arm-mounted Decorative Luminaires Retrofit Kits for Large Outdoor Pole/Armmounted Area and Roadway Luminaires Retrofit Kits for Outdoor Wall-mounted Area Luminaires 1,000 20-50º 30% -10% 20% 20-50º 50% -10% 40% 0-20º 30% -10% 20% 0-90º 100% -1% 99% 80-90º 10% 3% 13% 1,000 0-90º 65% -3% 62% 1,000 ac Retrofit Kits for Parking Garage Luminaires 2,000 300 0-90º 100% -1% 99% 80-90º 10% 3% 13% 0-90º 100% -3% 97% 80-90º 10% 3% 13% 60-80º 30% -3% 27% 70-80º 25% +3% 28% ad Retrofit Kits for Fuel Pump Canopy Luminaires 2,000 0-40º 40% -3% 37% 40-70º 40% -3% 37% DLC QPL TRT V3.1 Non-Cutoff and Semi-Cutoff Outdoor Wall-Mounted Area Luminaires DRAFT PROPOSAL Page 7 of 8
Primary Use Letter ae af ag ah ai aj ak Primary Use Designation Retrofit Kits for 2x2 Luminaires for Ambient Lighting of Interior (all Primary Use Retrofit Kits for 1x4 Luminaires for Ambient Lighting of Interior (all Primary Use Retrofit Kits for 2x4 Luminaires for Ambient Lighting of Interior (all Primary Use Retrofit Kits for High-bay Luminaires for Commercial and Industrial Buildings Retrofit Kits for Low-bay Luminaires for Commercial and Industrial Buildings Four-foot Linear Replacement Lamps (all Primary Use Two-foot Linear Replacement Lamps (all Primary Use Light Output (lm) 2,000 1,500 3,000 Zone/Spacing Criteria Nominal Requiremen t Requirement with 10,000 20-50º 30% -10% 20% 5,000 (<10,000) 1,600 lm (bare lamp) 3,000 lm (2 lamps in fixture) 800 lm (bare lamp) 2,000 lm (3 lamps in fixture) 20-50º 30% -10% 20% * requirements for non-cutoff and semi-cutoff wallpacks are within the 0-90 zone. I.e. luminaire must produce at least 300 lumens in this zone, and no more of 10% of lumens in this zone may be between 80-90 vertical angles. ** Bilateral, symmetric light distribution on two hemispheres *** One-sided, single hemisphere light distribution **** Bilateral for surface-mounted units, single hemisphere for corner-mounted units DLC QPL TRT V3.1 Non-Cutoff and Semi-Cutoff Outdoor Wall-Mounted Area Luminaires DRAFT PROPOSAL Page 8 of 8