Infrared Thermometer

Similar documents
Infrared Thermometer. Getting Started

62 MAX/62 MAX + Infrared Thermometer

MT4 MAX/MT4 MAX + Infrared Thermometer

62 MAX/62 MAX + Infrared Thermometer

562/563. Infrared Thermometers

64 Max IR Thermometer

Users Manual. Visit us at

Users Manual. Infrared Thermometer

62 MAX/62 MAX + Infrared Thermometer. Users Manual

3R, 3G 5R, 5G Point Laser Levels

64 Max IR Thermometer

Users Manual. Air Velocity Meter

6R, 6G 180R, 180G. Users Manual. Point and Line Lasers. Line Laser Levels

700G Series. Pressure Gauge. Safety Information

62 MAX/62 MAX + Infrared Thermometer

Precision Infrared Thermometer. Users Manual

62 MAX/62 MAX + Infrared Thermometer. Users Manual

Precision Infrared Thermometer. Users Manual

100 Ft. LASER DISTANCE METER

Manual Instructions IR Measuring Instrument GIM 1840 ST60 / ST80

Supplement. Title: 365 Users Supplement Issue: 8 Part Number: Issue Date: 7/16 Print Date: August 2010 Page Count: 6 Revision/Date:

IRT2 Dual Laser IR Thermometer - User Guide

Dual Laser InfraRed (IR) Thermometer

User's Guide. Pinless Moisture/Humidity Meter with Memory + IR Thermometer. Model MO295

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Mini InfraRed (IR) Thermometer with Type K Input and Laser Pointer

High Temperature InfraRed Thermometer with Laser Pointer

User's Guide. Pinless Moisture/Humidity Meter + IR. Model MO290

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

User Guide InfraRed (IR) Thermometer with Wireless Datalogger, Type K input & Laser Pointer MODEL 42560

Visit us at testo 835 Infrared and contact thermometer

Non-Touch Thermometer. User Manual. ARC Devices Ltd.

Dual Laser InfraRed (IR) Thermometer

INCU II. Users Manual. Incubator Analyzer

HXL. Operating instructions

C0-210 Carbon Monoxide Probe

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

NON-TOUCH THERMOMETER User Manual

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

I/R Thermometer Gun 12:1

OWNERS MANUAL OPERATION GUIDE

Table of Contents Title Page Introduction Contacting Uni-Trend Safety Information Features Display Buttons and Connector How the Thermometer works.

KM300 Carbon Monoxide Detection System Installation Manual

Pinless Moisture/Humidity Meter with Memory + IR Thermometer

IR D USB INFRA RED THERMOMETER

CA876 INFRARED K-THERMOMETER WITH LASER ENGLISH. User Manual. Auto OFF

ZP2 Series Operation Manual

Corning LSE Digital Dry Bath Heater

VT1101M VT1102M IFS Fiber Module Installation & Operation Instructions

Infrared Thermometer with 12:1 Distance-to-Sight Ratio and Temperature Alarm

IR Speed Dome. Quick Guide UD.6L0201B1357A01

IFS Fiber Module Installation & Operation Instructions

Microprocessor Digital Thermometer

R2310. Infrared Thermometer. Instruction Manual

Mold Alert... Operation Manual P0270

CONGRATULATIONS. on your purchase of a Viridian Reactor, the most advanced sighting device available. Technology on your new Reactor

u Do not use the appliance if any part is damaged or defective. u Do not short battery terminals. u Do not charge batteries.

NON-CONTACT VOLTAGE DETECTOR WITH ADJUSTABLE SENSITIVITY AND IR THERMOMETER USER S MANUAL

Digital Heat Block User Manual

Corning LSE 6L Digital Water Bath

IFS Fiber Module Installation & Operation Instructions

IFS Fiber Module Installation & Operation Instructions

TruVision IR Turret Camera TVT-2202/TVT-4202 Installation Guide

KFP-CF Series Operation Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL THL1

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

IFS Fiber Module Installation & Operation Instructions

THL2. Temperature/Humidity USB Datalogger INSTRUCTION MANUAL

Thermometer with Probe model 00891A

IFS Fiber Module Installation & Operation Instructions

Operator s Manual. IP-100 Immersion Probe Cooler

Forehead Infrared Thermometer

Customers must fill in and mail the warranty card in order to activate the warranty.

IFS Fiber Module Installation & Operation Instructions

Manual PCE-889 pyrometer

RS Pro Infrared Temperature Sensor

PIR Sensor. User s Guide

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

JOVY SYSTEMS RE User Manual Rev. 1.00

Ambient Weather WS-2063 Indoor Temperature and Humidity Monitor with Backlight User Manual

IFS Fiber Module Installation & Operation Instructions

Thermometer with Wired Sensor

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

No Touch Door Release Exit Sensor ACA-NTEB

Digital Refrigerant System Analyzer. MAXMIN Psi kpa Bar MPa C F R TIME P T UNITS

Humidity Monitor model 01080

Health Check Ear and Forehead Thermometer Model No.: Instruction Manual

LaserPoint srl - Via Burona, Vimodrone (Milano) - Italy Phone Telefax

With this symbol Gavita declares that this product complies with legal European requirements.

Installation Manual. THM-0100 Setpoint Thermostat Version THM HBX Control Systems Inc.

Model 1916-C/-R Hand-held Optical Power Meter

SEC Signature Process Gas Analyzer

User s Guide. OSXL685 and OSXL689. High Performance Infrared Thermometer. Shop online at

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Installation Guide

Filter Oven with Controller 101FRDC00-50 / 101FRDC00-CTRL

IFS Fiber Module Installation & Operation

WS-9117U-IT Wireless 915 MHz Temperature Station. Instruction Manual

Timer Wall Clock. Model: WT-8100U Quick Setup Guide BUTTONS

onlinecomponents.com

Transcription:

572-2 Infrared Thermometer PN 4307046 March 2013, Rev. 1, 08/13 2013 Fluke Corporation. All rights reserved. Specifications are subject to change without notice. All product names are trademarks of their respective companies.

LIMITED WARRANTY AND LIMITATION OF LIABILITY This Fluke product will be free from defects in material and workmanship for two years from the date of purchase. This warranty does not cover fuses, disposable batteries, or damage from accident, neglect, misuse, alteration, contamination, or abnormal conditions of operation or handling. Resellers are not authorized to extend any other warranty on Fluke s behalf. To obtain service during the warranty period, contact your nearest Fluke authorized service center to obtain return authorization information, then send the product to that Service Center with a description of the problem. THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED OR IMPLIED. FLUKE IS NOT LI- ABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CON- SEQUENTIAL DAMAGES OR LOSSES, ARISING FROM ANY CAUSE OR THEORY. Since some states or countries do not allow the exclusion or limitation of an implied warranty or of incidental or consequential damages, this limitation of liability may not apply to you. Fluke Corporation P.O. Box 9090 Everett, WA 98206-9090 U.S.A. 11/99 Fluke Europe B.V. P.O. Box 1186 5602 BD Eindhoven The Netherlands

Table of Contents Title Page Introduction... 1 Safety Information... 1 Thermometer Use... 6 Cable Connections and Battery Replacement.. 6 Menu Overview... 7 Specifications Summary... 9 i

572-2 Getting Started Manual ii

Introduction The 572-2 Infrared Thermometer (the Product) is for noncontact temperature measurement. The Product determines the surface temperature of an object by measuring the amount of infrared energy radiated by the object surface. A K-type thermocouple can be used with the Product for contacttemperature measurement. Safety Information A Warning identifies conditions and procedures that are dangerous to the user. A Caution identifies conditions and procedures that can cause damage to the Product or the equipment under test. Symbols used on the Product and in this manual are explained in Table 1. Warning To prevent possible electrical shock, fire, eye damage, and personal injury: Read all safety Information before you use the Product. Use the Product only as specified, or the protection supplied by the Product can be compromised. Do not use the Product around explosive gas, vapor, or in damp or wet environments. Do not use the Product if it operates incorrectly. 1

572-2 Getting Started Manual See emissivity information for actual temperatures. Reflective objects result in lower than actual temperature measurements. These objects pose a burn hazard. Do not look directly into the laser with optical tools (for example, binoculars, telescopes, microscopes). Optical tools can focus the laser and be dangerous to the eye. Do not look into the laser. Do not point laser directly at persons or animals or indirectly off reflective surfaces. Use the product only as specified, or hazardous laser radiation exposure can occur. Do not use laser viewing glasses as laser protection glasses. Laser viewing glasses are used only for better visibility of the laser in bright light. Do not open the Product. The laser beam is dangerous to eyes. Have the Product repaired only through an approved technical site. Have an approved technician repair the product. 2

Caution For safe operation and maintenance of the Product: Infrared Thermometer Safety Information Remove the batteries if the Product is not used for an extended period of time, or if stored in temperatures above 50 C. If the batteries are not removed, battery leakage can damage the Product. Replace the batteries when the low battery indicator shows to prevent incorrect measurements. Repair the Product before use if the batteries leak. Be sure that the battery polarity is correct to prevent battery leakage. Do not short the battery terminals together. Do not keep cells or batteries in a container where the terminals can be shorted. Do not put battery cells and battery packs near heat or fire. Do not put in sunlight. 3

572-2 Getting Started Manual Caution To avoid damage to the Product or the equipment under test, protect them from: EMF (electro-magnetic fields) from arc welders, induction heaters, etc. Static electricity Thermal shock (caused by large or abrupt ambient temperature changes. For highest accuracy, allow 30 minutes for Product to stabilize before use). See Figure 1 for the safety markings. Laser Aperture Figure 1. Safety Markings hdp01.eps 4

Symbol C Celsius Table 1. Symbols Explanation Hazardous voltage. Risk of electrical shock. Infrared Thermometer Safety Information Risk of danger. Important information. See manual. Warning. Laser. F Fahrenheit Conforms to European Union directives. Battery This product complies with the WEEE Directive (2002/96/EC) marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste. Product Category: With reference to the equipment types in the WEEE Directive Annex I, this product is classed as category 9 "Monitoring and Control Instrumentation product. Do not dispose of this product as unsorted municipal waste. Go to Fluke s website for recycling information. Battery Conforms to relevant South Korean EMC Standards. Conforms to China Metrology Certification. 5

572-2 Getting Started Manual Thermometer Use To take a temperature reading, point the Product at the desired object and pull the trigger. You can use the laser pointer to aim the Product. You may also insert the K-type thermocouple probe for contact measurement. Warning To avoid electrical shock or personal injury, do not connect the external contact probe to live electrical circuits. Cable Connections and Battery Replacement To connect the USB cable and Thermocouple to the Product, and to change the batteries, see Figure 2. AA (+) hdv04.eps Figure 2. Cable Connections and Battery Replacement 6

Infrared Thermometer Menu Overview Note To prevent incorrect readings, do not do a temperature measurement of an earthed conductor while the Product is connected to a PC that is earthed by a three-phase grounding plug. Menu Overview There are many settings that can be changed by using the menu. Table 2 is a top-level description of the menu. Push the Menu button to advance the menu to the next level. Figure 3 shows the LCD and menu interface. The Users Manual explains the menus in full detail. Figure 3. Menu Navigation hdp02.eps 7

572-2 Getting Started Manual Table 2. Top-Level Menu Description Level Left Softkey 1 Save 2 Mem 3 MnMx 4 F/ C 5 6 Setup Description Save reading to memory Review / delete memories Enables Min/Max Toggle between C and F Lock the Product on - Turn off backlight - Change Time/Date - Change Language Center Softkey Menu Right Softkey Light Description Adjust bright backlight Menu ε Set emissivity Menu Menu Menu Menu Avg Alarm Laser Enable Avg/Diff Set and enable alarms Toggle the laser on/off 8

Specifications Summary Infrared Thermometer Specifications Summary See Users Manual on CD for full specifications. IR Temperature -30 C to 900 C (-22 F to 1652 F) Range Accuracy 0 C: ± 1 C or ± 1 % of reading, whichever is greater ( 32 F: ± 2 F or ± 1 % of reading, whichever is greater) -10 C to <0 C: ±2 C( 14 F to <32 F: ±4 F) <-10 C: ±3 C (<14 F: ±6 F) K-Type Thermocouple Input -270 C to 1372 C (-454 F to 2501 F) Temperature Range K-Type Thermocouple Input Accuracy <-40 C: ±(1 C + 0.2 /1 C) -40 C: ±1 % or 1 C, whichever is greater <-40 F: ±(2 F + 0.2 /1 F) -40 F: ±1 % or 2 F, whichever is greater Distance:Spot (90 % energy) Laser sighting Emissivity Data storage 60:1 Dual laser, output <1 mw Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials 99 points 9

572-2 Getting Started Manual Communication USB 2.0 Operating Altitude 2000 meters Storage Altitude 12,000 meters Relative Humidity 10 % to 90 % RH non-condensing up to 30 C (86 F) Operating Temperature 0 C to 50 C (32 F to 122 F) Storage Temperature -20 C to 60 C (-4 F to 140 F) Power Battery Life Standards and Agency Approval Electromagnetic Compatibility 2 AA Batteries 8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (Thermometer continuously on) EMC: meets IEC61326-1: Portable Safety Compliance: IEC 60825-1, Class 2 Implement Standard: Q/SXAV 16 Applies to use in Korea only. Class A equipment; (Industrial Broadcasting & Communication Equipment) [1] [1] This product meets the requirement for industrial (Class A) electromagnetic wave equipment and seller or user should take notice of it. This equipment is intended to use in business environment and is not to be used in homes. 10