SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

Similar documents
SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

FLOAT BATTERY CHARGERS

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

LORAIN CIP 4890/48120 DC Power System

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

LORAIN CSP DC Power System

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

SECTION AUTOMATIC TRANSFER SWITCHES

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Installation Guide for models:

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

Spectron LSN (Life Safety Network) Suggested Specifications

FDF Foam Pump Controllers Features

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Installation Guide for models:

Remote NAC Power Supply D7038

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

B. Section Transfer Switches: Automatic transfer switch.

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

Public Safety DAS Annunciator Panel

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

DIESEL Engine Fire Pump Controllers Features

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

Commercial and Light Industrial Fire Alarm Control Panel

ESSEX ENGINEERING CORPORATION

Loadstar AC/DC Systems

Model 4001 Series Single Channel Controller

ECC-50/100C. Emergency Command Center

Pioneer-R16 Gas Monitor Operator s Manual

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

www. ElectricalPartManuals. com GADD MKIII Ground Fault Indication System Instruction Manual Ground Fault Protection

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

Dale Power Solutions Ltd

La Marche Manufacturing Company A36D. Battery Charger / Power Supply. Installation and Operation Manual

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

Installation, Operating and Maintenance Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Sierra Series 900 Single & Dual Channel System. Instruction Manual

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

LC2200 Level Controller Installation and Maintenance Instructions

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

SECTION POWER SUPPLIES AND DISTRIBUTION

MR-2602 Two Zone Fire Alarm Control Panel

Utility Battery Chargers DC Power Systems Custom Design

SECTION AUTOMATIC TRANSFER SWITCHES

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

Series. Access Power Controllers. Installation Guide

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

UC700 EMERGENCY TRANSFER SYSTEM SPECIFIER S HANDBOOK. 40 Dale Street West Babylon, NY Ph: Fx:

631RF Amp Power Supply

RE-PR3-E-27 3-Phase Panel Mount 27kW

Constant voltage charger. Type UP 610. »We store the world's energy« Network

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

Constant voltage 3-phase rectifier.

ANALOX 3000 Carbon Monoxide Monitor

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Fire Control/Communicator

AL800ULADA. NAC Power Extender. Installation Guide

TECHNICAL DATA OBSOLETE

www. ElectricalPartManuals. com GADP Ground Fault Indication System Instruction Manual Ground Fault Protection

CONTENTS AUTOMATIC TRANSFER SWITCHES

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

- 4 12VDC or 24VDC VDC or 24VDC - Eight (8) Fused Outputs - Eight (8) PTC Outputs. Installing Company: Service Rep.

July 14, 1999 DF C-100.

Table of Contents. Protective Relays

POWERPATH PS-8 (105531) PS-8E (100263) PS-6 (105530) PS-6E (100262)

Securitron Magnalock Corporation S. 51 st St., Ste. 102 Phoenix, AZ Phone: (800) MAGLOCK

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

DIESEL Engine Fire Pump Controllers Features

Across-the-Line SERIES MP300 Combined Manual and Automatic

CHAPTER 20 SERVICE EQUIPMENT

Soft Start Series MP700 Solid State, Reduced Voltage

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

Model PAD-3 Distributed Power Module NAC Expander Installation, Operation, and Maintenance Manual

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Transcription:

SCR/SCRF SERIES FLOAT BATTERY CHARGERS Industry s First Choice for Time-Tested Proven Reliability Single-Phase Input Three-Phase Input Applications for: Utility & General Industry Switchgear Engine starting Emergency lighting Alarm systems Railroad service UPS Communications & Telecommunications Radio Telemetering Microwave Telephone Computers & Control Systems Uninterruptible power systems

SCR/SCRF BATTERY CHARGER OPTIONAL ACCESSORIES Alarm Relays for Remote Indication* Available with or without front panel alarm indicating lights AC Power Failure Alarm Provides alarm state when AC power fails or AC breaker is open DC Ground Detection Alarms Provides alarm state when a ground fault has occurred at either the + or output terminal High-Low DC Voltage Alarms Provides high alarm state when battery is being overcharged and low alarm state when battery is near end of discharge Charger Failure Alarm (No DC Current) Provides alarm state when charger output current is less than 2% of rated output for 30 seconds or more.will also activate with AC power failure and/or DC breaker or fuse open. Battery Discharging Alarm Provides alarm state when battery discharge current exceeds the charger recharge current End of Discharge Alarm Provides alarm state when battery has discharged to lowest system voltage limit DC Current Limit Alarm Provides alarm state when charger output current reaches the current limit setting Common (Summary) Alarm Provides a single alarm state when any one or all monitored alarm conditions exist on charger *Alarm circuits provide one (1) set of dry form C contacts (SPDT) wired to a terminal strip for customer termination. Alarm circuits with two (2) sets of dry form C contacts (DPDT) are available without indicating lights at additional cost. Standard relay contacts are rated for resistive loads of: 1A @ 120Vac, 2A @ 28Vdc, 1A @ 52Vdc, 0.1A @ 130Vdc. Auxiliary relays are available for use with alarm circuits when alarm load exceeds the standard contact rating. Auxiliary relay contacts are rated for resistive loads of: 5A @ 120Vac, 5A @ 28Vdc, 2A @ 52Vdc, 0.5A @ 130Vdc. CASM, Combined Alarm - Status Monitor* The following alarm relays are available combined together on a single board. Each relay has one (1) set of isolated, dry form C contacts (SPDT) wired to a terminal strip for customer connection.two (2) sets of form C contacts (DPDT) are available at additional cost, as are one (1) set of latching relays. High-Low AC Voltage Alarm Relay With high and low indicating lights, 15- second time delay on alarm, auto reset High DC Voltage Alarm Relay With indicating light,15-second time delay on alarm, auto reset Low DC Voltage Alarm Relay With indicating light,15-second time delay on alarm, auto reset Ground Detection Alarm Relay With (+) ground detection indicating light and ( ) ground detection indicating light, 15-second time delay on alarm, auto reset Charger Failure Alarm Relay With indicating light, 30-second time delay on alarm, auto reset Common Alarm Relay Summary alarm relay for any one or all alarms on this board. *Alarm contacts are rated for 0.5A @ 120V AC or DC. Indicating lights are red LED s front panel mounted. A lamp test switch is provided for verifying operation of indicating lights. Customer terminal strip is rated 15A @ 120V AC or DC to accommodate #14AWG maximum wire.this option may be ordered without ground detection for DC systems that are referenced to ground. DC Ground Detection for Local Indication Ground Detection Switch for Front Panel DC Voltmeter Indication Measures voltage from + or output terminals to common ground Ground Detection Indicating Lights with Ground Test & Lamp Test Switch Front panel lamps indicate + or output ground fault with switch in ground test position.in lamp test position both lights are verified as operational. Equalize Timers 0-72hr. Manual Equalize Timer w/ or w/o Float Equalize Indicating Lights Replaces float/equalize switch. Charger automatically switches from equalize to float at end of set time interval. 0-72hr. Line Failure Auto-Equalize Timer w/float Equalize Indicating Lights Charger is switched to equalize for a set time interval after power is interrupted for 10 seconds or more. Equipped with float reset and equalize override switches. 0-72hr. Current Limit Auto-Equalize Timer w/float Equalize Indicating Lights Charger is switched to equalize for a set time interval after charger is in current limit for 10 seconds or more. Equipped with float reset and equalize override switches. AC Fuse Two-pole AC fuse for single-phase, 3-pole AC fuse for 3-phase DC Circuit Breaker Two-pole DC breaker is installed with one-pole standard fuse: 5000 AIC, UL Listed 100A-Frame 10000 AIC, UL Listed 250 & 400A-Frame 14000 AIC, UL Listed 600 & 800A-Frame Optional higher AIC circuit breakers are available. Forced Load Sharing Chargers operating in parallel share load to within 2% of output current of each charger. High DC Voltage Charger Shutdown A contact closure from a high DC voltage alarm activates the shutdown circuit and charger output current goes to zero. Filtered Battery Eliminator Output ripple voltage is 30mVrms or 0.06% of nominal output voltage, whichever is higher, without battery connected. Input Lightning Arrestors Provides additional input protection against lightning-induced transients, ANSI 37.90A Surge Withstand Capability Additional surge protection to meet performance requirements of IEEE-472 SWC specification AC Input Voltmeter and/or Ammeter Front-panel, 2% accuracy, 3.5-inch case, 1% 3.5-inch case, 1% 4.5-inch case, switchboard or digital Additional Optional Accessories Special input voltages and frequencies Device nameplates Special paint Special high-interrupting capacity Fungus proofing (tropicalization) NEMA-4 or NEMA-12 cabinets (AIC) circuit breakers Drip-proof cabinet shields Special hypalon internal wiring, switchboard type 1% accuracy panel or switchboard meters Alarm buzzer Cabinet heater strips Export packing

TYPICAL SCR/SCRF BATTERY CHARGER INTERNAL CONSTRUCTION DETAIL STYLE 1A CABINET CONSTRUCTION 13 14 15 16 11 1 2 3 12 11 4 5 STYLE 1B CABINET CONSTRUCTION 18 6 14 12 13 15 16 11 4 1 2 11 3 19 21 22 23 24 7 8 10 9 5 6 1. DC AMMETER 2. DC VOLTMETER 3. AC POWER ON LIGHT 4. EQUALIZE ADJUST LIGHT 5. FLOAT ADJUST POT 6. EQUALIZE TIMER (optional) FLOAT EQUALIZE SWITCH (standard) 7. DC CIRCUIT BREAKER (optional) 8. DC FUSE(S) 9. AC CIRCUIT BREAKER 10. DC SURGE SUPPRESSOR 11. STATUS INDICATING LIGHTS & SWITCHES (optional) 12. POWER ISOLATION TRANSFORMER w/ac RECONNECTION T.B. 13. AC SURGE SUPPRESSORS 14. SCR RECTIFIER/HEAT SINK ASSEMBLY 15. POLARITY & BLOCKING DIODE ASSEMBLIES 16. FILTER CHOKE(S) 17. BLEEDER RESISTOR 18. FILTER CAPACITORS 19. ALARM RELAY(S) (optional) 20. ALARM CONTROL MODULES (optional) 21. CONTROL MODULE 22. CURRENT LIMIT ADJUST POT 23. INPUT LINE & GROUND TERMINALS (TB1) 24. OUTPUT TERMINALS (TB2) 25. REMOTE ALARM TERMINALS (TB3) 5 21 22 19 20 18 14 15 18 17 19 20 21 22 23 25 24 STYLE 2 CABINET CONSTRUCTION 3 11 2 6 1 4 11 16 17 7 8 9 10 7 8 9 10 12 13

HOPPECKE SCR/SCRF Series of industrial float chargers is designed to automatically control charging rates for a wide variety of battery types and to simultaneously provide full-rated output for both continuous and intermittent dc loads. The chargers are constant voltage devices with automatic current limiting.voltage regulation and current limiting are controlled by solid-state integrated circuitry to assure maximum performance in minimum space. The SCR/SCRF Series is ideally suited to utility, communications and other stationary charger applications. DESIGN FEATURES Component Selection Electronic and electrical components are substantially derated to assure long life and reliability.typical MTBF is100,000 hours minimum. Components are selected or designed to provide a system life expectancy in excess of 30 years. Modular Construction Control circuits, alarm circuits and electrical sub-assemblies are printed circuit board wired or modularized with plug and socket connections for easy serviceability. Standard Sub-assemblies Control modules and many electrical sub-assemblies are standardized across the entire range of charger sizes.this minimizes spare parts inventory and simplifies maintenance. Durable Front panels are recessed to prevent accidental damage to meters and controls. Standard cabinets are NEMA-1 enclosures of heavy-gauge phosphatized steel with an attractive, long-lasting acrylic enamel finish. Easy Troubleshooting A complete service manual, color-coded wiring, test-point identification and circuit-symbol labeling of internal components make troubleshooting easy. Ease of Adjustment Tap adjustments are not required. Output float voltage, equalize voltage, current limit and alarm levels are potentiometer adjustable. Ease of Access Internal components and connections are easily accessible and/or removable through a hinged front door that opens approximately 180 degrees for easy serviceability. Ease of Installation Cabinets are floor, wall or rack mountable and equipped with knockouts for cable or conduit entrance. Input, output and remote alarm connections are wired to easily accessible, internal terminal blocks. ENVIRONMENTAL SPECIFICATIONS Operating Ambient Temperature 32 F to 122 F (0 C to 50 C) without derating Storage Temperature -40 F to 185 F (-40 C to 85 C) Operating Altitude 3300 feet (1000 meters) above sea level without derating Relative Humidity 5% to 95% (without condensation) Audible Noise Less than 65dBA at any point 5 feet from any vertical surface of enclosure.typical values measure 55 to 60dBA at 100% load. Ventilation Units rated 300Adc output or less are convection cooled via NEMA-1 vent openings in cabinet. Units rated 400Adc output or greater have fan-assisted convection cooling with overheat-audible alarm and remotealarm contacts. (Automatic charger shutdown due to overheat is optional.)

ELECTRICAL SPECIFICATIONS AC Input Standard transformers are available with taps for nominal voltages as listed below. Single-Phase Voltages: 120/220 240V 47 63Hz 480V 57 63Hz 120/208 240V 47 63Hz(optional) Three-Phase Voltages: 208 240V 57 63Hz 380 416V 47 63Hz 480V 57 63Hz Chargers are wired and circuit protected for one nominal input voltage and frequency to be specified at time of order. Output Regulation ±0.5% of DC voltage setting maintained with input line variations of -12%, +10% voltage and/or ±5% frequency ±0.5% of DC voltage setting maintained with load variations from no load to full load ±1.0% of DC voltage setting maintained against the combined variations of line, load and temperature Output Transient Response & Recovery ±5.0% max. of DC voltage setting maintained with step load changes from 20% to 100% load Recovery to ±2.0% of DC voltage setting typically 200msec Recovery to steady state DC voltage setting typically 500msec Overshoot of DC voltage setting is not present at turn-on due to softstart feature. Output Current Limit The electronic current limiting circuitry is factory set at 110% of rated output. It is continuously adjustable from 90% to 120% of rated load. Output Ripple and Electrical Noise* Unfiltered (SCR Series): Output ripple voltage is less than 10% RMS for single-phase input SCR units. Output ripple voltage is less than 3% RMS for three-phase input SCR units. Filtered (SCRF Series): Output ripple voltage is 30mVrms or less for all SCRF units. Electrical voice band noise is less than 32dBrnC using C- message weighting network. *Measured when connected to a battery with an 8-hr., Amp-Hour rating of 4 times the full load current rating of the charger. Random Parallel Operation SCR/SCRF Series Chargers may be random parallel operated with other chargers of similar regulation and current limit characteristics. Equal load sharing by two SCR-SCRF chargers requires the addition of the forced load sharing option. Battery Eliminator Operation SCR/SCRF Series Chargers will operate as DC power supplies without batteries. Addition of the Filtered Battery Eliminator option will reduce ripple, when used as a battery eliminator, to the greater of 0.06% or 30mV. VDC Nominal Float Adjustment Range (VDC) SCR/SCRF Battery Charger DC Output Table Equalize Adjustment Range (VDC) ADC Size Cell Available (1) Lead-Acid Cell Capability (3) (No. of Cells) Ni-Cd Cell Capability (3) (No. of Cells) 1φInput 3φInput Normal Reduced VPC Normal Reduced VPC 12 10.5-14.5 11.3-16 6 to 100 60 to 100 5-6 8-10 24 23-30 24.5-32 6 to 100 50 to 600 11-13 17-20 21 48 46-60 48-64 6 to 100 50 to 600 22-26 27 34-40 42 130 115-140 124-150 6 to 50 25 to 600 55-62 63 86-94 98 260 230-280 245-300 6 to 25 16 to 300 110-124 126 172-188 196 (1) The discrete Adc sizes offered within the ranges listed above are: 6, 12, 16, 20, 25, 30, 35, 40, 50, 60, 75, 100, 125, 150, 175, 200, 250, 300, 400, 500, 600Adc. All sizes are rated at 100% load. Some current ratings are not available on certain chargers. Consult factory or current price list for exact offerings. (2) Based on Lead-Acid Float of 2.15 to 2.25V/Cell and equalize of 2.25 to 2.4V/Cell. (3) Based on Ni-Cd Float of 1.35 to 1.45V/Cell and Equalize of 1.50 to 1.60V/Cell.

Typical SCR/SCRF Series O Motive Power Systems SCR/SCRF BATTERY CHARGER STANDARD ACCESSORIES AC On Indicating Light Green front panel indicator AC Input Circuit Breaker Single-Phase Input: Two-pole, 7500 AIC, UL Listed 100A-Frame Three-Phase Input: Three-pole, 7500 AIC, UL Recognized 100A-Frame Three-pole, 25000 AIC, UL Listed 225A-Frame Three-pole, 30000 AIC, UL Listed 400A and 600A-Frame DC Output Fuses Two-pole, fast-acting, currentlimiting rectifier type AC and DC Surge Suppressors MOV Type AC Withstand: 240Vac or less: 1500Vpk - 1.2x20 µsec pulse Over 240Vac: 3000Vpk - 1.2x20 µsec pulse DC Withstand: All DC outputs: 4000Vpk - 2x10 µsec pulse Typical internal construction detail showing combined alarm-status charger monitor option DC Output Ammeter and Voltmeter Front panel, 2% accuracy, 3.5-inch case Manual Float/Equalize Switch Front panel toggle switch Float and Equalize Adjustment Potentiometers Two front panel mounted, lockable adjustment potentiometers Current Limit Adjustment Potentiometer Internally mounted, with easily accessible adjustment DC Output Blocking Diode Standard SCR/SCRF Series feature prevents battery from discharging back through the filter and rectifier when charger is off due to AC power failure or charger malfunction. DC Output Protection Diode Prevents damage to charger and battery due to reversed polarity connections Color-Coded Internal Wiring 600 Volt, color-coded, polyvinylchloride (PVC) wiring is standard. UNREGULATED AC INPUT, 1 OR 3 AC INPUT CIRCUIT BREAKER INPUT SURGE PROTECTION POWER ISOLATION TRANSFORMER SCR/DIODE RECTIFIER BRIDGE FILTE (S AC ON INDICATING LIGHT R REMOTE ALARM SIGNAL HI LOW AC or AC POWER FAILURE ALARM (optional) CONTROL POWER INTERNAL HVDC ALARM SIGNAL CHARGER SHUTDOWN (optional) CONTROL (TRIGGER) MODULE w/current LIMIT ADJUSTMENT

Typical SCR/SCRF Performance Curves 2.5 2.4 2.3 2.2 2.1 2.0 1.9 1.8 Equalize Calcium Float Antimony Float Conversion Efficiency Single-Phase Charger 100 90 80 70 60 50 40 30 Vdc/cell 1.7 1.6 0 10 20 30 40 50 60 70 80 90 100 110 120 % Load Current limit adjustment % Efficiency 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 % Load Vdc/cell Output Regulation Ni-Cd Batteries 1.7 1.6 Equalize 1.5 1.4 Float 1.3 1.2 1.1 1.0 0 10 20 30 40 50 60 70 80 90 100 110 120 % Load Current limit adjustment % Efficiency Conversion Efficiency Three-Phase Charger 100 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 100 110 120 % Load ne-line Circuit Diagram R SECTION CRF only) REVERSE CURRENT POLARITY PROTECTION OUTPUT FUSE PROTECTION DC OUTPUT CIRCUIT BREAKER (optional) OUTPUT SURGE PROTECTION REGULATED DC OUTPUT EMOTE ALARM SIGNALS HI LOW VOLTAGE ALARMS (optional)* REMOTE ALARM SIGNAL REMOTE ALARM SIGNAL REMOTE ALARM SIGNAL CHARGER FAILURE ALARM (optional)* GROUND DETECTION ALARM (optional)* COMMON or SUMMARY ALARM (optional)* INTERNAL ALARM SIGNAL(S) FLOAT/EQUALIZE SELECTION (TIMER is optional) CURRENT SENSE VOLTAGE SENSE & ADJUSTMENT *These alarm options are available together as a single circuit board. See combined alarm-status charger monitor on optional accessories page.

SCR/SCRF Battery Charger, Size, & Weight Data Table 12Vdc 24Vdc 48Vdc 130Vdc 260Vdc ** Ampere Rating* Single-Phase Input 6 70 1A 80 (36) 95 1A 90 (41) 170 1A 105 (48) 370 1B 125 (57) 670 2 230 (104) 12 135 1A 90 (41) 200 1A 105 (48) 330 1A 120 (54) 740 1B 160 (73) 16 180 1A 98 (44) 260 1A 115 (52) 440 1B 135 (61) 990 1B 210 (95) 1790 2 320 (145) 20 230 1A 105 (48) 320 1A 125 (57) 540 1B 160 (73) 1230 1B 220 (100) 25 290 1B 120 (54) 400 1B 135 (61) 680 1B 170 (77) 1540 1B 230 (104) 2790 3 490 (222) 30 340 1B 130 (59) 480 1B 150 (68) 810 1B 190 (86) 1850 1B 250 (113) 35 400 1B 135 (61) 560 1B 160 (73) 950 1B 210 (95) 2150 2 340 (154) 40 460 1B 145 (66) 640 1B 180 (82) 1080 1B 220 (100) 50 570 1B 160 (73) 800 1B 190 (86) 1350 2 245 (111) 3080 2 440 (200) 60 680 2 185 (84) 960 2 210 (95) 75 850 2 205 (93) 1200 2 245 (111) 2020 2 330 (150) 100 1130 3 280 (127) 1600 3 320 (145) 2700 3 440 (200) Three-Phase Input 16 1260 2 350 (159) 20 25 1260 2 300 (136) 1960 3 510 (231) 30 1510 2 330 (150) 35 1760 2 355 (161) 2750 3 560 (254) 40 2010 2 380 (172) 50 740 2 210 (95) 1230 2 255 (116) 2510 3 500 (227) 3920 3 590 (268) 60 600 2 215 (98) 880 2 240 (109) 1480 2 320 (145) 3010 3 520 (236) 75 750 2 240 (109) 1100 2 275 (125) 1850 2 350 (159) 3760 3 550 (249) 5880 4 890 (404) 100 990 3 315 (143) 1470 3 360 (163) 2460 3 460 (209) 5010 3 680 (308) 7840 4 1000 (454) 125 1840 3 425 (193) 3080 3 500 (227) 6260 3 750 (340) 150 2200 3 480 (218) 3690 3 540 (245) 7510 4 915 (415) 11800 5 1480 (671) 175 2570 3 510 (231) 4300 3 600 (272) 8760 4 1010 (458) 200 2940 3 550 (249) 4920 3 650 (295) 10100 4 1100 (499) 15700 5 1610 (730) 250 3670 3 600 (272) 6150 4 750 (340) 12600 5 1400 (635) 300 4400 4 710 (322) 7380 4 860 (390) 15100 5 1500 (680) 23600 5 1950 (885) 400 5870 4 780 (354) 9830 4 950 (431) 20100 5 1650 (748) 500 7340 4 850 (386) 12300 5 1350 (612) 25100 5 1820 (826) 600 8800 4 925 (420) 14800 5 1500 (680) 30100 5 1950 (885) *Heat loss in BTU/hr. is stated for nominal number of cells at float voltage and 100% dc load current. **Consult factory for ampere and voltage ratings up to 1000A and 600V. Ordering Information Specify: Charger model number: X SCR X XXX XXX X 1 or 3 phase input Omit for unfiltered, or add F for filtered 012, 024, 048, 130 or 260 nominal Vdc output 006 to 600 rated Adc output Omit if not required, or add E for filtered battery eliminator (SCRF units only) Nominal input (Vac) and frequency (Hz) Number and type of battery cells All optional accessories required on charger Consult factory for higher dc voltage output and dc current outputs. Specifications and performance data subject to change without notice. Cabinet Dimensions CABINET STYLE 1A 1B 2 3 4 5 TYPE MOUNTING Wall*** Wall*** Floor*** Floor Floor Floor DIMENSIONS (inches) H 15 26 1 4 37 3 8 49 62 80 W 18 1 4 19 20 3 8 32 42 58 D 12 1 8 15 1 2 14 3 4 24 24 30 ***Rack-mounting cabinet is optional for these styles. HOPPECKE Batteries Inc. 1960 Old Cuthbert Road, Suite 130, Cherry Hill, NJ 08034, U.S.A. Phone: 856-616-0032 Fax: 856-616-0132 Further information: www.hoppecke-us.com