Today's world of increasing

Similar documents
A Guide to Safe Electronic Weighing in Hazardous Locations

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Understanding Hazardous Locations Concepts

Overview of Hazardous Locations as They Relate to Solenoid Valves

Beamex. Calibration White Paper. Calibration in hazardous areas

Installation guide for hazardous areas

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Fire Alarm System Accessories

Fire Alarm System Accessories

Hazardous Area Classifications and Protections

Beamex Calibration White Paper. Calibration in hazardous areas

Products Solutions Services CT287. Hazardous Area Classifications and Protection Systems

INSTRUCTION & SERVICE MANUAL

Specifying Temperature Sensors for Hazardous Areas

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Guide for hazardous areas

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

UL HAZARDOUS LOCATIONS SERVICES

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

4) Intrinsic Safety Certification

ATEX, NOMENCLATURE AND CODING

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Page 1 Copyright by the Fieldbus Foundation All rights reserved.

Hazardous Area Classification in Oil & Gas Industry. A Fire Prevention Tool

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

ATEX, NOMENCLATURE AND CODING

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

HOW TO FIND THE RIGHT DEVICE FOR YOUR FACILITY

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

Instrumentation Products and Applications

Intrinsically Safe Solutions

Safety instructions VEGADIS DIS61.CC/O** VEGADIS DIS81.CC/O******

Intrinsically Safe or Explosionproof? Understanding the technology

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

National Fire Protection Association. 1 Batterymarch Park, Quincy, MA Phone: Fax:

INSTRUCTION MANUAL. SIL 3 - SIL 2 IIB Group Power Supply for Hazardous Area Equipment DIN-Rail Model PSD1001C PSD1001C

[ TECHNOLOGY ] and does this definition affect a burner.

Certificate of Compliance

Guide to Hazardous Location Approvals:

Intrinsic Safety. Intrinsically Safe Solutions. Accurate Weighing in Hazardous Areas

Smoke detection in hazardous areas:

Certificate of Compliance

Annubar Flowmeter Series

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

Hazardous area descriptions

Model D12-IR. Digital Gas Transmitter...

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

Intrinsically Safe Transmitters, Option Code 2n

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

Commercial and Light Industrial Fire Alarm Control Panel

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Introduction to Hazardous Electrical Location Classifications

D SYSTEM CONTROL DWG. APPROVED BY. OrCAD 6 ROSEMOUNT 2410

Tank Gauging System Special Safety Instruction

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

MICROpeL 75 Combustible Gas Sensor Part Number: PM

standards: standards:

S T R I T T & P R I E B E I N C.

ORDER CODES T-642B 76T82- D10 77T-662C. CODE DESCRIPTION 38 3/16 6HN 1/2" x 1/2" NPT steel hex nipple 1" "E" length 48 1/4 68 3/8

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

AGENDA. NEC Code-Making Panel 14. Report on Comment Meeting. November 28-December 1, Redondo Beach, CA

Guide to Intrinsically Safe Portable Radios

Explosion-protected network cameras Safety first

Hazardous Area Zirconia Oxygen Systems

SBEx-4 BISTATE SEPARATOR 1, 2, 3 or 4 channels in rail housing (TS35, 22,5mm width)

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

MODULAR INTEGRATION OF PROCESS EQUIPMENT PACKAGES FOR OIL AND GAS FACILITIES

specifically for explosion prone areas can substantially reduce the risk of combustion.

Certificate of Compliance

PURGE/PRESSURIZATION SYSTEM

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Explosion-proof Duct Heaters

Certificate of Compliance

Intrinsically Safe Flame Detector Installation Guide

YTA Series Temperature Transmitters [Style: S3] EN :2006, -11:2007, -26:2007. Supply circuit: Ui=30 V, Ii=165 ma,

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Certificate of Compliance

Numerical Standards Listing

Numerical Standards Listing

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

ACHIEVING REDUNDANT INTRINSICALLY-SAFE FIELDBUS SEGMENTS FOR FISCO & ENTITY DEVICES

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

GG-LEL2 COMBUSTIBLE GAS SENSOR. Installation and Operation Manual

Installing Foundation Fieldbus H1 in Hazardous Areas. Presented By: Jim Peterson Sr. Applications Engineer MTL/USA

Circulation Heaters Selection Guidelines

DB5 Intrinsically Safe Sounder Type DB-5

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Numerical Standards Listing

IECEx Certificate of Conformity

Model 144H. Product Data Sheet , Rev DB February Content

Relays for use in hazardous locations. Class I, Division 2 and ATEX

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Model 3300 Technical Support and Installation Manual

Transcription:

Applying Intrinsic Safety Today's world of increasing process control in potentially explosive atmospheres has forced designers and engineers to specify more efficient and effective ways of protecting personnel from harm and property from damage. Since its initial introduction nearly 50 years ago, intrinsic safety has evolved into a complete system solution including remote I/O (inputs and outputs). What Is Intrinsic Safety? Intrinsically safe equipment is defined as equipment and wiring which is incapable of releasing sufficient electrical or thermal energy under normal or abnormal conditions to cause ignition of a specific hazardous atmospheric mixture in its most easily ignited concentration. 1 This is achieved by limiting the power available to (and used or generated by) the electrical equipment in the hazardous area to a level below that which will ignite the hazardous atmosphere. The following industries are known to have hazardous locations: chemical, munitions, petrochemical, auto (paint spray booths), grain, waste water, printing, distilling, pharmaceutical, brewing, cosmetics, mining, plastics and utilities. What authority allows the user to utilize intrinsic safety? Normally, the user s insurance carrier and/or government authority having jurisdiction require that the system be approved by a recognized approval authority. In North America, the following organizations develop and publish documents and standards dealing with intrinsic safety: the National Fire Protection Agency (NFPA), the Canadian Standards Association (CSA), Underwriters Laboratories (UL), Factory Mutual (FM), National lectric Code (NC), and the Instrument Society of Measurement and Control (ISA). Typically, I.S. products are tested and Approved or Listed by Factory Mutual Research Corporation or Underwriters Laboratories, Inc. The Canadian Standards Association is the predominant approval authority of Canada. Many international standards for intrinsic safety exist throughout the world. The most influential of these is the uropean Committee for lectrotechnical Standardization (CNLC). The CNLC standards are a single set of documents agreed upon by all of the member nations, mainly the uropean Community nations of Western urope. There are several test laboratories authorized to issue approvals of intrinsic safety equipment to CNLC standards. A CNLC certification is valid in all CNLC member nations. When installing electrical equipment in a hazardous area, extensive regulations must be observed. In North America, these regulations must be verified in each province, state or city since individual locations can differ in their installation and/or application of intrinsic safety. The same is true in urope where regulations are subdivided into uropean (U) and national requirements. The uropean standards define the general specifications and the detailed guidelines for methods of protection against explosion. The national requirements primarily contain installation requirements. In the past, the U.S. and Canada have relied on classification of hazardous areas by Classes, Divisions and Groups. Although this system is still in use, North America is gradually beginning to adopt a classification system based on Zones as standardized in many countries of the world (those accepting International lectrotechnical Commission (IC) or CNLC standards). The chart on the next page compares common specifications of xplosion Protection for the uropean Union and North America. Note 1: xcerpt from ISA-RP12.6 A129

Type of Hazard Classification by Classes, Divisions and Groups xplosive mixtures of air with: Class I: gases or vapors Class II: dusts Class III: fibers or flyings Classification by Zones xplosive mixtures of air with flammable gases or vapors. Group I: Mines where methane may be present Group II: Places with potentially explosive atmosphere other than mines susceptible to methane Degree of Hazard Division 1: An explosive concentration of the hazardous material may be continuously, intermittently or periodically present under normal operating conditions. Zone 0: An explosive air/gas mixture is continuously present or present for long periods. Zone 1: An explosive air/gas mixture is likely to exist under normal operating conditions for short periods. Division 2: An explosive concentration of the hazardous material is present only under fault conditions and if such a condition occurs, it will exist only for a short period. Zone 2: An explosive air/gas mixture is not likely to occur under normal operating conditions and if such a condition occurs, it will exist only for a short period. Ignition by Spark xplosive atmospheres are grouped according to their ignition capabilities. Representative atmospheres are: Group A: acetylene Group B: hydrogen Group C: ethylene Group D: propane Group : metal dust Group F: carbon dust Group G: flour, starch, grain xplosive gases are grouped according to their ignition capabilities. Representative gases are: Group I: methane Group IIC: hydrogen, acetylene Group IIB: ethylene Group IIA: propane Ignition by Hot Surface Hazardous area apparatus is classified according to the maximum surface temperature produced under fault conditions at an ambient temperature of 40 C (or as otherwise specified). T1: 450 C T2: 300 C T2A*: 280 C T2B*: 260 C T2C*: 230 C T2D*: 215 C T3: 200 C T3A*: 180 C T3B*: 165 C T3C*: 160 C T4: 135 C T4A*: 120 C T5: 100 C T6: 85 C *North America only Gas Characteristics Information regarding gas grouping by ignition energy and gas ignition temperatures are contained in: -NFPA 497M, Manual for Classification of Gases, Vapors and Dusts for lectrical quipment in Hazardous (Classified) Locations -CSA No. C22-1 -NC Article 500 -British Standard Code of Practice for lectrical Apparatus and Associated quipment for use in xplosive Atmospheres (other than Mining Application), BS5345: Part 1 Basic requirements for all parts of the code A130

Instruments Commonly Found in s: Switches Includes push buttons, selector switches, float switches, flow switches, proximity switches, limit switches, etc.) RTDs An RTD (resistance temperature detector) converts temperature into resistance. An example of a resistance change is.385 ohms/ C for a 100 Ohm platinum RTD. Thermocouples A thermocouple is a device used to sense temperature. It is inexpensive and with the various types available, covers a wide range of measured temperatures. Thermocouples are constructed of two dissimilar metals which generate a millivolt signal varying with temperature. I/P Converters This device is commonly known as an electro-pneumatic transducer or current/pressure converter. It converts a DC milliamp signal to a proportional pneumatic output signal. This pneumatic signal is commonly used to position a control valve. Transmitters A 2- or 3-wire transmitter is a device used in a control system which converts a process variable (i.e., temperature, level, pressure, flow, etc.) to a proportional electrical signal. The electrical output is a 0/4-20mA, 0/ 1-5V or 0/2-10V signal. Light mitting Diodes (LDs) Standard incandescent bulbs may not be used in explosive areas because of radiant heat, current requirements and the susceptibility of the bulb to breakage. LDs are an alternative that can be made intrinsically safe through the use of barriers. Solenoids A solenoid is an electrically actuated valve that allows full flow or no flow of gases or liquids. Standard 24 VDC solenoids may not be used in the hazardous area due to the coil's energy storing capacity. I.S. Solenoids In order to design a solenoid for hazardous areas and to obtain I.S. certification, one common procedure is to embed (2) diodes connected in parallel to the coil. These diodes are used to eliminate the potential arcing if a wire were to break in the hazardous area during operation. These diodes will suppress the arc and provide the solenoid with a low inductance rating. A131

Some I.S. solenoid manufacturers go a step further when installing diodes in their valves. They are installed as full wave bridge rectifiers which give the additional advantage of non-polarity sensitive valves. The diodes in series cause an additional voltage drop of approximately 1.4V (.7Vx2). This is very important when applying intrinsic safety barriers. Strain Gauges Strain gauges are used to measure stress or are used in load cells, scales and transducers to measure force, weight and pressure. The operation of a strain gauge is based on the premise that the electrical resistance of metal wire is changed when it is stretched or compressed. Potentiometers Potentiometers are adjustable resistors. The resistance value (ohms) changes with mechanical movement of the wiper. Audible Alarms Audible alarms (horns or buzzers) are devices sometimes used in hazardous areas to signal that an event has taken place. Typically, the choice of which barrier to use would be the same for audible alarms as it is for solenoids. Serial Communications Serial communication is the transfer of data in a sequence of bits, generally in the form of a low voltage signal (0-15V). The most common serial communications protocol is RS-232. Fire Detectors A fire detector is used to detect flames in a hazardous environment. In the normal state, a low current (4-6mA) passes through the detector circuit. When an alarm condition occurs, higher current (15-20mA) flows through the circuit. An end-of-line resistor distinguishes between detector normal state and a broken wire between detector and barrier (a broken wire means zero current flow). What is a simple apparatus? The approval agencies recognize devices known as simple apparatus. A simple apparatus does not generate or store more than the following: 1.2V 100mA 20µJ 25mW This type of device does not need certification from a third party. ven though a device is considered a simple apparatus, it must be connected to an intrinsic safety barrier. xamples of simple apparatus are: A132

Discrete Inputs Limit, Pressure, Float, Flow and Temperature switches Push buttons Analog Inputs Thermocouples RTDs Discrete Outputs LDs What Are Zener Diode Barriers? Zener diode barriers limit the energy to the hazardous area to a level below that which could ignite a specific air/gas mixture. This is accomplished by protecting against the following faults: 1.Shorting of wires connected to the hazardous area side of the barrier. 2.Grounding of wires connected to the hazardous area side of the barrier. 3.Misconnection or failure of the power supply allowing an unsafe voltage to be applied to the safe area side of the barrier. The barrier will prevent unsafe levels of voltage current from passing into the hazardous area as a result of these conditions. A schematic diagram of a zener diode barrier is shown below with a resistor for current limitation, a fuse which opens in the case of excessive current and redundant zener diodes which limit the voltage to a safe level. The Alternative to Zener Diode Barriers Transformer Isolation While zener diode barriers provide suitable protection, operate properly and are cost effective, inherent characteristics require close attention to the installation. Transformer Isolated Barrier 1.A high integrity intrinsic safety ground is required to be connected to the ground electrode. There must be no more than one ohm of resistance in this line. 2.A regulated power supply should be utilized. This will prevent the possibility of the voltage rising too high, causing the zener diodes to conduct and the fuse to open, or falling too low preventing the minimum operating voltage from reaching the field device. 3.Process control loops cannot totally float above ground. Therefore, it is possible to obtain electrical noise on the control signal. 4.If the protective fuse should open, it cannot be replaced and the barrier must be discarded. Resistor Resistor Z-diodes Z-Diodes I.S. Ground A133

Because of these considerations, we have designed a different type of barrier known as a Transformer Isolated Barrier (TIB). It is designed to address each of the disadvantages of zener barriers. A simplified diagram is shown on the previous page. A TIB contains a zener barrier for the voltage and current limitation. However, it does not utilize an I.S. ground. The transformer in a TIB provides a high degree of isolation between the primary and secondary windings, therefore, the ground connection is unnecessary. Advantages of Transformer Isolated Barriers vs. Zener Diode Barriers 1.Transformer isolated barriers do not require a high integrity I.S. ground since the transformer isolates the hazardous area connections from the non-hazardous area connections. 2.Regulated power supplies are no longer necessary. A voltage regulator circuit is used to allow a wide supply voltage range without interruption of the process or damage to the barrier. 3.Any process control loops (milliamp or millivolt signals) connected to a TIB will remain floating, unlike zener barriers that ground one side of the signal or at best provide a quasi-floating system. 4.TIBs can be repaired, unlike zener barriers that are encapsulated in epoxy. 5.TIBs contain current limiting circuitry that will not allow the protective barrier fuse to open in the case of a short circuit condition. 6.TIBs are designed for specific applications (transmitter, solenoid, switching input, thermocouple, etc.), allowing easy system design. Faults The major objection to using zener diode barriers is that they must be connected to an I.S. ground. This is absolutely necessary to keep a fault in the safe area from reaching the hazardous area. Resistor Z-diodes AC/DC Power Supply Control Transformer Fault Current Path I.S. Ground Faults In a TIB, the fault current will flow through the primary of the transformer. Once the current has reached a sufficient level, the fuse will open, preventing the fault condition from reaching the hazardous area. Resistor Z-diodes AC/DC Power Supply Control Transformer Incoming Power Distribution A134

When to Use Transformer Isolated Barriers There are several good reasons to consider TIBs: When installation of a high integrity I.S. ground is impractical, costly or even impossible. When regulated power supplies are too expensive. When the potential of signal noise due to ground loop problems is undesirable. When the cost of replacing zener barriers due to installation problems (misconceptions and shorted wires) exceeds the initial cost of TIBs. When the total loop resistance (including barrier, interconnecting cable and safe area load) exceeds the specifications of the transmitter (transmitter applications) or controller card (I/P applications). When uncertainty arises during the design of the system due to unfamiliarity with applying barriers. TIBs are not without a downside. Generally, TIBs cost more than zener barriers and in some cases, need a separate power supply. However, they may be connected in parallel so that one power supply may feed many TIBs. ntity Parameter Matching Transmitter quipment Approval Methods There are two methods used by approval authorities to ensure an intrinsically safe system. Although they may be called by different names by each authority, the two methods can be described as system approvals or parametric approvals. 1. System Approvals The system approval method is one in which specific field devices are examined in combination with specific barriers. No other field device or barrier may be substituted unless specifically examined by the approval authority. 2. Parametric (ntity) Approvals The parametric approval method is one in which each piece of equipment is evaluated separately and assigned a set of safety parameters. The field device may then be connected to a barrier with compatible safety parameters, sometimes known as entity parameters. Tolerable Fault Voltage (V MAX ) Tolerable Fault Current (I MAX ) Internal Unprotected Capacitance (C i ) Internal Unprotected Inductance (L i ) V I MAX MAX i C L i V I C oc sc a L a Barrier Fault Voltage ( V oc ) Fault Current ( I sc ) Allowable Capacitance ( C a ) Allowable Inductance ( L a ) A135 The hazardous area instrument is given the following entity parameters: U i ; V max Maximum allowable voltage under fault conditions I i ; I max Maximum allowable current under fault conditions C i Internal unprotected capacitance L i Internal unprotected inductance

The safety barrier is given the following entity parameters: U 0 ; V oc Open circuit voltage - maximum voltage that can be transferred to the hazardous area under fault conditions. I 0 ; I sc Short circuit current - maximum current transferred to the hazardous area under fault conditions. C 0 ; C a Maximum allowable capacitance that can be connected to the barrier including interconnecting wiring (C cable ). L 0 ; L a Maximum allowable inductance that can be connected to the barrier including interconnecting wiring (L cable ). Wiring Practices* Intrinsically safe wiring must be separated from non-intrinsically safe wiring in order to prevent the transfer of unsafe levels of energy to the hazardous area. The following are a few recommended practices. In the hazardous area, all intrinsically safe and non-intrinsically safe wiring must be separated by the same methods suggested for the safe area. However, the following requirements must also be followed: 1.In enclosures containing multiple intrinsically safe circuits, the terminals for connection must have a spacing of at least 6mm or a grounded or insulated partition between the circuits. 2.Devices like limit switches or pressure switches must not contain a non-intrinsically safe circuit in addition to an intrinsically safe circuit unless: A. It is enclosed in a separate compartment, or B. It is separated by 50mm spacing or contains a grounded metal or insulated partition. 3.When conduit or raceway is utilized to enclose intrinsically safe wiring, it must be sealed or vented in order to prevent the transfer of hazardous atmosphere to a safe area. In the non-hazardous area, intrinsically safe and non-intrinsically safe wiring must be separated by one of the following methods: 1.Raceway or conduit 2.Grounded metal or insulated partition between the intrinsically safe and non-intrinsically safe wiring 3.Airspace of at least 50mm (2 inches) between intrinsically safe and non-intrinsically safe wiring and the wires must be tied down to prevent loosening and shorting together. The same methods are used for intrinsically safe and non-intrinsically safe terminals. General Requirements Intrinsically safe wiring must be identified, preferably by color coding of light blue, if no other wiring is light blue. If light blue is used on non-intrinsically safe wiring, the intrinsically safe wiring can be marked by other means, such as tagging. This alternate means, however, must be visible after installation. Wiring xamples The pictures shown on the following page show barriers mounted in enclosures and wired in unsafe and safe examples. *These sections are to be used as guidelines or recommendations only. For rules and more detailed practices, refer to National lectrical Code, NFPA 70 Article 500, ISA-RP12.6-1995 or N 50 020. A136

Unsafe Wiring Wired Correctly Unsafe Wiring In Picture #1, the hazardous and safe area wiring are too close together (<50mm). Therefore, it is unsafe. Wired Correctly As shown in Picture #2, both sets of wiring are properly tied down and the distance between the safe and hazardous area wiring is >50mm. Therefore, the installation is considered safe. 1 2 Unsafe Wiring In Picture #3, both conduit entrances are on the same side of the enclosure. Once again, the wiring is too close together and is considered unsafe. Wired Correctly Picture #4 shows that either the tie-down method of the wiring or installing a partition (either grounded metal or insulated) is considered safe. 3 4 Unsafe Wiring Picture #5 shows the barriers connected to a field wiring terminal strip. Because there is not proper distance between the safe and hazardous area wiring (<50mm) on the terminal strip, it is not considered safe. Wired Correctly In order to properly wire this enclosure safely, a partition must be installed between the safe area and hazardous area terminals as shown in Picture #6. 5 6 A137