Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

Similar documents
INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

PRYCO, INC. FUEL CONTROL

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

ESSEX ENGINEERING CORPORATION

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Operating Instructions

Features. Omni2 Door Warning Sign Alarm Annunciator DATASHEET. Model C1190B Door Warning Sign

For more information, please visit or call toll free at

Operating Instructions

LEAKMONITOR MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND USER OPERATION MANUAL

Installation, Operating and Maintenance Manual

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

SERIES VAC Microprocessor-Based Direct Spark Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION. Export Information (USA)

FlashGuard 3000B Dual Lighting System Troubleshooting Guide

HOKKIM INTEGRATED AMF CONTROL BOARD MANUAL FOR MODELS: HAMF-8 AND HAMF-4

Sentry LIQUID LEVEL CONTROLLER MODEL 120 OPERATING MANUAL.

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

Operating Instructions

vibration switch

Construction Electrical

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

Product Manual. The `Safety Shoe (shown below):

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

D-TEK -MS Vehicle Loop Detector. Operating Instructions

BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES. READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION.

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

PSN-1000 & PSN 1000(E) Installation Manual

DSGH. Radiation-Based Detector with GEN2000 Electronics for Density Measurement QUICK REFERENCE GUIDE

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

Unit 3 Machine Composition

Battery Fail Monitoring System

Commercial and Light Industrial Fire Alarm Control Panel

MD12-2 Vehicle Loop Detector

Pump Logic User Manual CB-1000 P/N ILK-CB1000-1

ACCURATE ELECTRONICS INC

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Model 17A00 Expansion Enclosure

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

21-light Remote Annunciator. Owner s Manual

SECTION LOW VOLTAGE LIGHTING CONTROLS

INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

ENGINEERED PARKING SYSTEMS MODEL 3416D

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

Stancor Duplex Oil-Minder System Submittal SE Volt Single Phase Duplex SE-100 Pumps with Floats and Oil-Minder Probe

Pump-Down Controller MODEL 4052

TECHNICAL DATA OBSOLETE

PO Box 827 Hawley, MN (218) Fax (218)

Model 4880 Status Output Display Module Manual

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Intelligent Security & Fire Ltd

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Installation Instructions

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

Excel-EN Conventional Fire Control Panel

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

MPT Electric Fire Pump Controller

INPUT / OUTPUT MINI MODULES

End To End Optical Beam Smoke Detector. Additional Information

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

Model A1600 Series Annunciator

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

I/O ZONE 560/583 AND OPERATION MANUAL

PS6 SERIES. Installation PS6 SERIES. Power Supplies c/w Fire Panel Interface, EOL Trigger and Standby Power Option

Electric Coils. Blower Coils. Product Information

MODEL ORP/pH Digital Controller

Installation Instructions for W2H Series Signals

Gas Safety Products. Installation, operating and maintenance. Merlin 1000S+i Gas & Electric Utility Controller. Rev: 03 Date:

Incident resolution workflow

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

DIGITAL LIGHT CONTROLLER

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

LMS-188-4P-BMS 4 POINT DIGITAL MONITOR/ALARM WITH PROTOCOL CONVERTER OPERATING INSTRUCTIONS

Operation & Maintenance Manual

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL AH1000, BH1000, AND EH1000 SERIES ANNUNCIATORS

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

Pump-Up Controller MODEL 4062

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

PumpSaver ISS-105 IS Super Cell Installation Guide

WIRING DIAGRAM AND INSTRUCTIONS

ETSA380MF SHOWN WARNING. shall be used ONLY on approved vehicles. It is the sole responsibility of the user of these devices to ensure compliance.

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

MODEL 5100 VOTING LOGIC MODULE

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

631RF Amp Power Supply

ANALOX 3000 Carbon Monoxide Monitor

Conventional Fire Alarm System 2014 V1.2

Emerald 3000 MK3 GJD010 Lighting Controller

INSTALLATION INSTRUCTIONS TEC40 ELECTRONIC CONTROLLER

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Model 3300 Technical Support and Installation Manual

Transcription:

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX BACKUP PUMP CONTROL SYSTEM MODEL NUMBER BPC-3 November 22, 1999 Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA 01460-1431 USA Telephone: 978-486-9800 Facsimile: 978-486-0170

1.0 PURPOSE This document establishes the performance and design requirements for the Triplex Backup Controller 2.0 APPLICABLE DOCUMENTS None 3.0 REQUIREMENTS 3.1 GENERAL DESCRIPTION The Triplex Backup Pump Control System (BPC-3) is a system, which automatically controls up to three pumps. It is primarily intended to be a backup pump controller in lift stations and other pump down applications. The BPC-3 can also function as a primary float switch controller. It has three possible modes of operation, two backups and one primary. It automatically selects the appropriate mode of operation. When operating as a backup controller it would only call for a pump if the primary controller failed to maintain the wet well level within normal operating limits. If the backup controller senses that the level has exceeded the primary control upper limit then it will take over and operate the pumps. When the backup controller takes over control it sets an alarm relay and lamp which will not clear until the backup controller is manually reset. The backup controller can function with either one or two float switches when in backup mode. When operating as a primary controller it uses four float switches to control the pumps and has an optional high alarm float input. 3.1.1 SINGLE FLOAT BACKUP MODE In this mode a single high float is suspended in the wet well above the main controllers operating range. If the primary controller should be unable to maintain the level below this point the float switch will close and the backup controller will be activated in the single float backup mode. When this happens the alarm relay will be closed and the alarm light will be illuminated. One of the pump control relays will close calling one of the pumps. After a delay of 8 seconds the second pump control relay will close calling the second pump. After another 8 second delay the third pump is called. The controller then waits for the level to pump down to a point where the float switch opens. After the high float switch opens the pumps remain on for a period of time selected by the delay time switches on the backup controller. After the delay has elapsed the three pumps will turn off. The alarm relay and lamp will remain energized. The backup controller will then wait for the high float to again close and repeat the above operation except that the three pumps will be called in a different order ( alternated ) to equalize pump wear. The delay time can be selected using eight switches on the backup pump controller for a time between 0 and 255 seconds ( 4.25 min.).

3.1.2 DUAL FLOAT BACKUP MODE In this mode two floats are suspended in the wet above. the primary controllers operating range. These floats are a high alarm float and an off float If the primary controller fails to maintain control, the level will rise and close the lower float ( off float ). As the level continues to rise it reaches and closes the high alarm float which causes the backup controller to set the alarm relay and call the three pumps ( 8 seconds apart). The pumps stay on until the level is pumped down to the point that the off float opens again and the pumps turn off. The alarm relay and lamp, however, stay on. Each cycle the pumps are alternated to equalize pump time. This mode has the advantage that both the on and off points can be selected by the position of the two floats. 3.1.3 PRIMARY FLOAT SWITCH CONTROLLER MODE The backup controller can also function as a primary float switch controller. This mode is a standard float switch controller with a high alarm. In this mode the pumps are controlled by four float switches ( off, lead, lag1, and lag2 ). As the level rises it closes the off float first. As it continues to rise the lead float is closed which starts one of the pumps. If the level continues to rise it will reach the lag1 float and call the second pump. If the water level continues to rise it will reach the lag2 float and call the third pump. The controller assures that at least 8 second have elapsed between pump calls. The pumps remain on until the level has been pumped down to the point where the off float opens. Each cycle the pumps are alternated. In this mode if the level reaches the high float then the alarm relay and lamp are energized but will turn off when the level drops below the high float 3.2 SYSTEM OPERATION As described above. 3.3 REQUIREMENTS The Backup Controller is a microcomputer based device which has the following hardware features: 1. Five float switch inputs for the float switch modes. 2. Four relays for driving three motor starters, and the alarm. 3. Five indicator light emitting diodes (lamps). Three for the pumps, one for alarm and a blinking OK light for normal standby mode. 4. Eight switches for setting the delay time. 5. A 68HC11 microcomputer. 6. A power supply for system power. 7. A reset push button for clearing the alarm.

3.3.1 The five float switch inputs are all self powered and optically isolated. The floats are connected between the float common pin ( pin 4 ) and the individual float input. The floats must be all normally open ( closed when submerged ) type floats. The float switch inputs have the following specifications: Voltage when open Current when closed Isolation 12.0 VDC 1.5 Ma 2500 V rms 3.3.2 The Backup Controller System has four relays which have the following specifications: Contact rating Breakdown voltage Life 10 amps at 125 VAC 800 Volts RMS 100,000 minimum cycles at rated load 5,000,000 cycles unloaded 3.3.3 The Backup Controller System has 5 LED indicators which have the following functions: OK Flashes green when the system is operating normally and the backup controller has not been called. PUMP 1 Illuminates when pump 1 has been called by the backup controller PUMP 2 Illuminates when pump 2 has been called by the backup controller PUMP 3 Illuminates when pump 3 has been called by the backup controller ALARM Illuminates red when the backup controller has been called. 3.3.4 Eight switches have been included for setting the delay time for the single float backup controller mode. Figure 3 gives the details for setting these switches. 3.3.5. The controller has a reset push button which can be used to clear the alarm. 3.3.6 Input Power. The system is designed to operate on standard 115 VAC line power. It is fused, surge protected, and transformer isolated. The system has the following input power requirements Input Voltage 115 VAC +/- 15% Input Current.5 amps max Input power is transient protected. Transient protection is a metal oxide varistor. The power system is regulated.

3.4 CONNECTOR PIN DEFINITIONS All electrical connections to the controller are made through a 24 pin connector. PIN NO. FUNCTION 1 115 Volts A.C. power input 2 115 Volts A.C. power input 3 GROUND 4 FLOAT COMMON 5 HIGH ALARM RELAY normally open pin 6 HIGH ALARM RELAY common pin 7 HIGH ALARM RELAY normally closed pin 8 Pump 3 relay contact 9 Pump 3 relay contact 10 Pump 2 relay contact 11 Pump 2 relay contact 12 Pump 1 relay contact 13 Pump 1 relay contact 14 Ground 15 High float input 16 Lag2 float input 17 Lag1 float input 18 Lead float input 19 Off float input 20 (not used) 21 (not used) 22 (not used) 23 (not used) 24 GROUND