FIRE SUPPRESSION RATING SCHEDULE ITEMS CONSIDERED AND ASSOCIATED POINTS OF CREDIT

Similar documents
The 2012 Fire Suppression Rating Schedule (FSRS)

Public Protection Classification (PPC ) Summary Report

ASHLAND. Kentucky. '. '.. I I I "t t

10.0 Apparatus and ISO Ratings

Fire Suppression Rating Schedule

RE: Tontitown Includes Tontitown Area FD FPSA, Washington County, AR Public Protection Classification: 4 Effective Date: August 1, 2013

Naples Fire-Rescue Department City Council Workshop February 19, 2013 Stephen R. McInerny II, Fire Chief

Chief Mark Crews gave a brief introduction regarding the Work Session and introduced Mr. Jack J. Krakeel to the Board.

WASHINGTON SURVEYING AND RATING BUREAU

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION.0900 PUBLIC PROTECTION CLASSIFICATIONS FOR FIRE DISTRICTS

CITY OF OWENSBORO OWENSBORO FIRE DEPARTMENT DEPLOYMENT ANALYSIS

FIREFIGHTER II: FIRE DEPARTMENT COMMUNICATIONS COMMUNICATIONS: SKILL SHEET #2 Define and Demonstrate Fire Department Radio Procedure

INCIPIENT FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

The City of Edmonton. Fire Rescue Service. Fire Rescue Service Review & Recommendations 2005

NATIONAL FIRE PROTECTION ASSOCIATION Fourth Survey of the Needs of the U. S. Fire Service

Published on MTAS MORe ( Home > Printer-friendly PDF > Estimating the Travel Time of Fire Apparatus

Public Protection Classification Summary Report

Required Materials For complete material(s) information, refer to

Talking about NFPA History of NFPA NFPA Standard 1710: Organization and Deployment of Fire Suppression Operations, EMS

REQUIREMENTS TO MEET THE 9S RATING FOR INITIAL CERTIFICATION/RE-INSPECTION OF FIRE DEPARTMENTS IN NORTH CAROLINA

Pro Board Assessment Methodology Matrices for NFPA 1001

Fire Department Anchorage: Performance. Value. Results.

I. It shall be the responsibility of the department officers to implement this operating guideline.

Whitestown Fire Department 5-Year Growth Plan

SUMMARY. Building receiving sprinkler credit: SPRINKLERED. Grade: 68. Percent of Building Sprinklered: 100% Sprinkler Demand Met: 91%

SCOTTS HILL, TENNESSEE

Township of North Kawartha. Report to Council Emergency Services Department

FIRE PROTECTION DIVISION PRIMARY FOCUS

11 NCAC 05A are repealed as published in 32:05 NCR as follows:

Branch Fire Rescue Services

The 2012 Fire Suppression Rating Schedule (FSRS)

Fire Flow Requirements Standard

ADDISON COUNTY FIREFIGHTERS ASSOCIATION MUTUAL AID SYSTEM STANDARD OPERATING GUIDELINES

Fire Flow Requirements Standard

Based on NFPA 1001: Standard for Fire Fighter Professional Qualifications, 2013 Edition.

Fire Service Considerations A Primer for Building and System Designers. Society of Fire Protection Engineers Fire Service Committee

FIREFIGHTER 1 COMPETENCY EVALUATION

Standardized Curriculum Form Ontario, Canada

9S / 9E Inspection Worksheets. The fire department should complete the following sheets prior to inspection date

DOD FIRE SERVICE CERTIFICATION SYSTEM LESSON PLAN 7. Fire Alarm and Communication

Centers for Regional Excellence. Downriver Fire Authority. Organization Committee Objective. Operations Committee Report 2007

DEPARTMENT SUMMARY. Personnel Services $ 7,780,971 $ 7,989,600 $ 7,707,680 $ 8,231,680. Operating Expenses 835, , , ,870

EASTERN ARIZONA COLLEGE Fire Department Operations II

CHAPTER 05 OFFICE OF STATE FIRE MARSHAL

MATRIX TO DETERMINE YOUR PRESENT POSITION IN MEETING N.F.P.A. 1720

Chapter 1 Test. Directions: Write the correct letter on the blank before each question.

About This Report. Risk Id: 32 NC N Church St Charlotte NC Mecklenburg County Last Update: 3/1/2015 On-Site Survey: 3/1/2015

DEPARTMENTAL GUIDELINES CHAPTER 6 TACTICAL OPERATIONS

SERFF Tracking #: ISOF State Tracking #: Company Tracking #: AL-2012-FSRS

FIRE FIGHTER II APPLICATION PENNSYLVANIA VOLUNTARY FIRE SERVICE CERTIFICATION PROGRAM NFPA Edition

MISSION VISION CHIEF S EXPECTATIONS AT YOUR SERVICE

TABLE OF CONTENTS Part 6 Legal Basis for Fire Safety Planning... 2

Adoption of The 2007 Dallas Fire Code

Leland Township Fire & Rescue Staffing and Deployment Analysis

WELCOME TO ROSEVILLE UNIVERSITY

Cisco Safety Solutions for Education

Fire Suppression Introduction Contact Information

Essentials of Fire Fighting, Fourth Edition Transition Guide. Chapter 1: The History of the Fire Service (Essentials, Chapter 1)

STONY HILL RURAL FIRE DEPARTMENT OPERATING GUIDELINES

As firefighters dismounted their apparatus, they recognized the life hazard that was presented. WNYF 2 nd issue 1967

Performance Metrics for First Responder Locating/Tracking Technologies

SOUTHERN AFRICAN EMERGENCY SERVICES INSTITUTE NPC Registration No. 2014/162285/08. Fire Fighter 1 - NFPA 1001, 2008

Building Emergency Response Scenario

5.8 PUBLIC SERVICES FIRE PROTECTION AND EMERGENCY SERVICES

Thomasville fire rescue

FRS 101 INTRODUCTION TO FIRE SERVICE 45 CLOCK HOURS 3 CREDIT HOURS. Course Title Lecture/Skill Total Fractional Credit

NATIONAL COMPETENCY STANDARD

Technician I Kyle Wilson Line of Duty Death April 16, Marsh Overlook Structure Fire Investigative Report

COUNTY OF BERGEN DEPARTMENT OF PUBLIC SAFETY LAW AND PUBLIC SAFETY INSTITUTE POLICE, FIRE & EMS ACADEMIES 281 Campgaw Road Mahwah, N.J.

Rapid Intervention Team

Rescues individuals in danger from fire, vehicle accidents, industrial accidents and other situation requiring extraction.

FIREFIGHTER II MANIPULATIVE SKILL OBJECTIVES

DCN: COMMUNICATIONS MANUAL CHAPTER 1 January 1, 1997 ALARM TRANSMISSION SYSTEMS

SPARTA, TENNESSEE. Fire Management Study. January 2012

SURREY FIRE SERVICE. Construction Fire Safety Plan Bulletin

Fire Department Orientation / Organization

CHAPTER 05 - OFFICE OF STATE FIRE MARSHAL SUBCHAPTER 05A - FIRE AND RESCUE SECTION GENERAL PROVISIONS

FIREFIGHTER/ENGINEER

INTERNATIONAL ASSOCIATION OF FIRE FIGHTERS

St. Vincent s Health System Page 1 of 6

San Ramon Valley Fire Protection District GREEN SHEET

U.S. FIRE DEPARTMENT PROFILE THROUGH 2009

PART I - SAFETY BULLETINS #9, 10 & 13 & EVOLUTIONS #6, 8 & 9:

UAF Police Department Emergency Communication Center USAGE AND SERVICE REPORT. December 31, 2011

Westbury Fire Department: Hose Company 2 Drill 7/24/14 Thinking Beyond the Obvious or the Norm

EASTERN ARIZONA COLLEGE Fire Department Operations I

Assignment Sheet Apply the NIMS-ICS Model to an Emergency Scene

INTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

FIR 3305, Fire Protection Structure and Systems Course Syllabus. Course Description. Course Textbook. Course Learning Objectives.

NFPA Fire Fighter I (Including Entry Level Fire Fighter) Task Book

Fire Signal Receiving Centres vs. Proprietary Fire Signal Receiving Centres CAN/ULC-S561 ALAN CAVERS ULC

Additional Materials: Instructor s PowerPoint, Question Files

FIREFIGHTER 1 COMPETENCY EVALUATION

Public Input No. 4-NFPA [ Section No. 4.2 ] Statement of Problem and Substantiation for Public Input. Submitter Information Verification

ADVANCED EXTERIOR FIRE BRIGADE MEMBER MANIPULATIVE SKILL OBJECTIVES GENERAL

Humboldt No. 1 Fire Protection District

NFPA Self Assessment Manual

FIRE SAFETY PLAN. BUILDING NAME: Pathobiology / AHL BUILDING NUMBER: 089. DATE: 15-August-10 FPO #2

Cedar Hammock Fire Rescue Standard Operational Guidelines FIRE WATCH. General. Requirements for a Fire Watch

Transcription:

FIRE SUPPRESSION RATING SCHEDULE ITEMS CONSIDERED AND ASSOCIATED POINTS OF CREDIT A. COMMUNICATIONS ITEM POINTS OF CREDIT TOTAL POINTS OF CREDIT 1. Telephone service, listing in directory and recording facilities 2. Operators (dispatchers) 3. Alarm dispatch circuits, radio and emergency power facilities 2.0 3.0 Total Points of Credit Communications 10.0 B. FIRE DEPARTMENT 1. Engine companies and equipment 2. Reserve engine companies and equipment 3. Pumping capacity 4. Ladder/service companies and equipment 5. Reserve ladder/service companies and equipment 6. Distribution of companies and equipment 7. Manpower 8. Training 9. Public Fire Control Activities* 10.0 1.0 1.0 4.0 1 9.0 2.0* Total Points of Credit Fire Department * This item is credited as Bonus Credit C. WATER SUPPLY 50.0 1. Supply works, fire flow delivery and hydrant distribution 2. Size, type and installation of hydrants 3. Inspection and condition of hydrants 3 2.0 3.0 Total Points of Credit Water Supply 40.0 MAXIMUM TOTAL POINTS OF CREDIT FOR ALL ITEMS 100.0

Our Mission: The Municipal Division of the Property Insurance Association of Louisiana has a two-fold mission. First, we assess the Fire Suppression capabilities in Louisiana. Second, we assess the effectiveness of Building Codes in use in Louisiana. Both of these areas provide factors to be applied in determining insurance rates for properties in Louisiana. Fire Suppression Information: The Fire Suppression Rating Schedule (FSRS) Needed Fire Flow Receiving and Handling Fire Alarms Fire Department Water Supply Divergence Needed Fire Flow: Needed Fire Flow is the amount of water required for fire suppression as determined for specific target buildings within each graded area. Calculating the Needed Fire Flow (NFF) Requirement is essential to determining adequacy of engine companies, adequacy of pump capacity, and the amount of water required for fire suppression. The NFF for any building is dependent on its construction materials, occupancy, exposures and communication factors. The 300 Section of the FSRS contains basics for calculating NFF. Prior to a field visit, the PIAL Field Representative will calculate the NFF for significant structures in each graded area. Because the FSRS uses a worst case scenario when determining each area s water supply needs, these NFF are then sorted from highest to lowest. Normally, 15 to 30 buildings are targeted for evaluation during each grading, but depending on the size of the area to be graded, more or fewer may be targeted.

Receiving and Handling Fire Alarms (10% of Available Credit) In the area governing Receiving and Handling Fire Alarms, the FSRS looks at several areas as follows: Telephone Service: This item reviews the facilities provided for the public to report fires, including the listing of fire and business numbers in the telephone directory and the number of emergency lines provided to the communications center. Telephone Operators: This item reviews the numbers of operators on duty at the communications center to handle fire calls. This is dependent on the emergency call volume of the PSAP. If the PSAP is able to provide a Call Detail Report (CDR) for the graded year, and if the CDR shows that there are an adequate number of operators on duty to answer the call to the NFPA 1221 Standard, then the number of operators on duty is deemed adequate no matter how many operators are on duty. If a CDR cannot be provided, then the Call Volume Matrix is used to determine the adequate number of operators needed to handle the annual call volume. Dispatch Circuits: This item reviews the dispatch circuit facilities used to transmit alarms to fire department members. Departments receiving more than 730 dispatches in the graded year require two independent dispatch circuits. In addition, the PSAP is evaluated for dispatching recording capabilities, emergency power arrangements, and testing programs. Fire Department (50% of Available Credit) In the area governing Fire Department, the FSRS looks at several areas as follows: Engine Companies: This item reviews the number of engine companies and the hose and equipment carried. Pump Capacity: This item reviews the total available pump capacity. Reserve Engines: This item reviews the number of reserve pumpers, their pump capacities, and the hose and equipment carried on each. Ladder/Service Companies: This item reviews the number of ladder and/or service companies, their location and equipment carried on each.

Reserve Ladder/Service Companies: This item reviews the number of reserve ladder and/or service companies, and the equipment carried on each. Distribution: This item reviews the percentage of built-upon area which has an adequately equipped, responding first-due engine company within 1 ½ road miles and an adequately equipped, responding ladder and/or service company within 2 ½ road miles. Company Personnel: This item reviews the average number of firefighters and company officers on duty with existing companies and the volunteer/off-duty response of firefighters responding to working fires. Training: This item reviews the training facilities and their use. Also reviewed is the hours trained in specific areas. Public Fire Control Activities: This item reviews the Public Fire Control Activities (Fire Prevention) and allows for Bonus Credit which may be added to the final grading of the Fire Department Section. Water Supply (40% of Available Credit) In the area governing Water Supply, the FSRS looks at several areas as follows: Water System: This item reviews the supply works, the main capacity, and hydrant distribution. In areas receiving Water Hauling Credit, the delivery rate is considered here. Hydrants: This item reviews the type of hydrants and method of installation as well as frequency of inspection and condition of the hydrants. Dry hydrants are included here when in service in the graded area.

Divergence Divergence is used to even out the Fire Department and Water System Credits. Because the Fire Department receives 50% of available credits while the Water Supply receives only 40% of available credits, the divergence factor puts them on a level playing field. As a result, a graded area with a fantastic fire department without an adequate water delivery system cannot receive a very high score. Conversely, a graded area with a fantastic water system without an adequate fire department to place the water on the fire also cannot receive a very high score. It is important to note here is that Receiving and Handling Fire Alarms does not affect the divergence factor.