COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET

Similar documents
LABEL PLEASE NOTE: ALL APPLICATIONS AND SITE PLANS MUST BE COMPLETED IN BLACK OR BLUE INK ONLY

MECHANICAL EXHAUST VENTILATION SYSTEMS OPERATIONAL GUIDELINES-REVISED 2003

Commercial Kitchen Exhaust Requirements Kitchen Exhaust for Food Service Operations

CALIFORNIA DEPARTMENT of FORESTRY and FIRE PROTECTION OFFICE OF THE STATE FIRE MARSHAL UL 300

Design & Construction Standards, Revised January

Lombard Fire Department Bureau of Fire Prevention COMMERCIAL HOOD & DUCT SYSTEMS

Kitchen Ventilation Hood Permit Application

Bold items are particular to the City of Euless

2012 ICC Commercial Kitchen Hoods

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

REQUIREMENTS FOR HOOD PLANS

International Fire Code 2006 Requirements for Construction Plan Reviews of Commercial and Multi-Family Structures

Minimum Information Required to Process your Special Occasion Application. Parking area Access to site

MECHANICAL EXHAUST VENTILATION SYSTEMS FOR RETAIL FOOD FACILITIES. Design, Calculations, and Operational Guidelines

Mobile Vendors Bulletin

SACRAMENTO FIRE DEPARTMENT FIRE PREVENTION DIVISION FIRE DEPARTMENT DEVELOPMENT SERVICES UNIT CONTRATOR INFORMATION PACKET

2015 ICC Commercial Cooking Systems

Rancho Cucamonga Fire Protection District Prevention Bureau Standard

MSYS 4490 AC Systems

FIRE ALARM SYSTEMS INFORMATION PACKET. Des Moines Fire Department Fire Prevention Bureau

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

To expedite the plan review and inspection processes, please refer to the information below.

MOBILE FOOD VENDING Food Trucks & Trailers

D. Reference Standards (Utilize latest editions available):

CITY OF LONG BEACH Department of Development Services BUILDING AND SAFETY BUREAU FIRE ALARM / ELECTRICAL FIRE PLAN REVIEW CHECKLIST

AUTOMATIC FIRE SPRINKLER SYSTEMS

September 30, Dear Fire Suppression System Contractor/Designer:

ISO INTERNATIONAL STANDARD. Ships and marine technology Fire-extinguishing systems for protection of galley cooking equipment

Ships and marine technology Fireextinguishing. of galley cooking equipment

SANDUSKY FIRE DEPARTMENT Fire Prevention Bureau. Dear Prospective Food Vendor:

FIRE & LIFE SAFTEY STANDARD

Low Wall Back Shelf Exhaust Canopy

MINOOKA FIRE PROTECTION DISTRICT Fire Prevention Bureau Fire Inspector Rodney Bradberry

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Rocky Mountain Fire Protection District 4390 Eldorado Springs Drive Boulder, CO

Project Name: Project Address: Installer Name: Installer Address: Date of Inspection:

Types of Detection. Fusible Link Detection - Most Common

You are required to READ ALL PAGES. of this application

GLENDALE FIRE DEPARTMENT FIRE MARSHAL S OFFICE

Anticipated Date and Time for Completion of Break-Down:

CHAPTER 5: EXHAUST SYSTEMS

CORPUS CHRISTI FIRE PREVENTION MOBILE FOOD VENDOR REQUIREMENTS

Second Revision No. 1-NFPA 17A-2016 [ Section No ] Submitter Information Verification. Committee Statement. 1 of 14 6/22/2016 3:15 PM

Fire Suppression Installation (R-102) for AVI Hoods & XLT Ovens

Dear Concessionaire,

NFPA 101 Life Safety Code Culture change 2012

CLARK COUNTY FIRE DEPARTMENT Fire Prevention Bureau

Fire/Life Safety Policy

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

New Construction Fire Inspection Process

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2009

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Tents and Temporary Membrane Structures Packet

Land Use and Environmental Service Agency (Code Enforcement) Mechanical Q&A 2009

Temporary LPG Heat for Construction Sites Information Packet

Valuation: # of Plans Submitted: # of pages: Type of Work (select one): New Addition Existing System/Modification Project Name: Scope of Work:

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Commercial Remodel/ Add On Rules and Regulations

Temporary LPG Heat for Construction Sites Work At Risk and Inspection Information Packet

Chapter One Commercial Kitchen Fires

STATE FIRE MARSHAL S REQUIRED FIRE PROTECTION SYSTEMS NARRATIVE REPORT

Moreno Valley Fire Department Fire Prevention Bureau. New and Existing Fire Alarm & Signaling Systems Guideline

Tents and Temporary Membrane Structures Permit Procedure

COMMERCIAL KITCHEN FIRE SAFETY

SAF-BCF SECOND REVISIONS WITH STATEMENTS

Design & Construction Standards, Revised January

NASSAU COUNTY FIRE PROTECTION PERMIT APPLICATION

Brighton Area Fire Authority

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

30 DAY TEMPORARY TENT APPLICATION ON EXISTING COMMERCIAL PROPERTY

Kitchen Fire Suppression Systems Post-Event Analysis

Fire Sprinkler Submittal Requirements and Acceptance Testing

ALARM SYSTEMS AND EVACUATION PLANS SELF INSPECTION CHECKLIST

9 E. Scarborough Park Concession Stand and Restroom And / Or Lake Kirby Park Softball Fields Restroom Addition

NFPA 96, 2017 REVIEW SUMMARY

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

BULLETIN. Permitting Tips (11/10)

Clark County Department of Building & Fire Prevention 4701 West Russell Road, Las Vegas, NV (702) FAX (702)

FIRE ALARM APPLICATION CITY OF MADISON HEIGHTS

D. The work addressed in this section consists of a fire protection system, which may include coordination with one or more of the following:

Minimum Standards for Engineers Practicing Fire Protection Engineering in the State of Oklahoma September 14, 2016

CODE ENFORCEMENT AND CERTIFICATION OF INSPECTORS FOR PUBLIC SCHOOLS, CHARTER SCHOOLS AND JUNIOR COLLEGES

Commercial Rules and Regulations

Department of Planning & Community Jefferson Station 1526 E. Forrest Avenue Suite 100 East Point, GA 30344

H BUTCH BROWNING FIRE MARSHAL BUILDING REHABILITATION

First Revision No. 49-NFPA 17A-2015 [ Detail ] Submitter Information Verification. Committee Statement 7/30/2015 1:35 PM

RULES OF DEPARTMENT OF COMMERCE AND INSURANCE DIVISION OF FIRE PREVENTION CHAPTER FIRE PROTECTION SPRINKLER SYSTEM CONTRACTORS

FIRE PREVENTION OFFICE Placer Hills Fire Protection District NEW PROJECT GUIDELINES

South Elgin & Countryside Fire Protection District

Fire Prevention Coffee Break Training. February 2016

Narrative Reports As Regulated by 780 CMR, Section 903.0

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION CHECKLIST

YORK COUNTY DEPARTMENT OF FIRE SAFETY BUILDING PLAN REVIEW REQUIREMENTS

Plan Submittal Checklist

XRRS Specification Fire Ready Hood

Oklahoma. 265: Incorporated national codes and standards The following national codes and standards are incorporated by reference:

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

Application for Certification for an Alarm System Contractor

TRI-LAKES MONUMENT FIRE PROTECTION DISTRICT

Burnsville Fire Department 100 Civic Center Pky, Burnsville, MN Fire Marshal: FAX:

Transcription:

COMMERCIAL KITCHEN SUPPRESSION SYSTEMS INFORMATION PACKET Colorado Springs Fire Department Division of the Fire Marshal October 2013

Table of Contents PURPOSE... 3 SCOPE... 3 DEFINITIONS... 3 GUIDELINES... 3 I. INTRODUCTION.... 3 A. APPLICABLE CODES AND STANDARDS.... 3 B. ADMINISTRATIVE REQUIREMENTS.... 4 II. SUBMITTAL INFORMATION.... 4 A. MINIMUM REQUIREMENTS OF THE CSFD FOR SUBMITTAL.... 5 III. GENERAL INFORMATION AND REQUIREMENTS... 5 A. MONITORING.... 5 IV. SPECIFIC SYSTEM INFORMATION.... 5 A. APPLIANCES REQUIRING PROTECTION... 5 B. WET CHEMICAL EXTINGUISHING SYSTEMS... 6 C. DRY CHEMICAL EXTINGUISHING SYSTEMS... 7 V. INSTALLATION... 7 A. PERMITS... 7 VI. INSPECTIONS AND TESTING.... 8 A. VISUAL INSEPCTION... 8 B. SYSTEM OPERATIONAL TESTS... 8 C. MANUFACTURER DESIGN MANUAL... 8 D. INSTALLER CERTIFICATION... 8 REFERENCES AND LINKS... 8 ATTACHMENTS... 8 WORKING DRAWING SUBMITTAL CHECKLIST... 9 PERMIT APPLICATION... 10 Colorado Springs Fire Department Page 2 of 11 10/15/13

PURPOSE This information packet has been developed in an effort to provide the highest level of service to the customers of the CSFD. The major goal plan reviews conducted by the CSFD is to ensure the design of wet chemical commercial kitchen suppression systems meet the minimum requirements of the adopted codes and ordinances. To meet this goal, the submitted plans and supporting documentation must contain the information needed to conduct a thorough review. SCOPE This packet outlines the minimum requirements set forth in the International Fire Code, local amendments, and departmental policies and procedures as they relate to the installation of wet chemical commercial kitchen suppression systems. This packet is not intended to provide an all-inclusive listing of submittal and inspections requirements, as it would be virtually impossible to cover all situations. This packet only covers requirements set forth in the latest edition of applicable NFPA standards listed below. This packet does not cover any other type of suppression system. Also included in this packet is information covering items required to be included on the working drawings and supporting documents. DEFINITIONS CSFD NFPA RBD IFC Colorado Springs Fire Department National Fire Protection Association Regional Building Department International Fire Code GUIDELINES I. INTRODUCTION. A. APPLICABLE CODES AND STANDARDS. 1. 2009 International Fire Code and its local Amendments. 2. 2009 International Mechanical Code and local Amendments. 3. 2013 Edition of NFPA 17A Wet Chemical Extinguishing Systems. 4. 2011 Edition of NFPA 96 Ventilation Control and Fire Protection of Commercial Cooking Operations. 5. Colorado Springs City Ordinances. 6. CSFD Administrative Rulings/Interpretations. Colorado Springs Fire Department Page 3 of 11 10/15/13

B. ADMINISTRATIVE REQUIREMENTS. 1. Approved Contractors. All suppression contractors must obtain a Colorado Springs Fire Suppression Contractor s B License in order to design, install, add to, alter, service, repair, and inspect commercial kitchen suppression systems, in accordance with Pikes Peak Regional Building Code, Section 207. Please contact Regional Building Department, Contractor Licensing at 719-327-2884 for additional information. 2. Service Technicians. A Colorado Springs licensed Service Technician shall be on-site for all installations, additions, alterations, repair and inspections of commercial kitchen suppression systems. Service Technicians are required to pass a test and obtain approval from CSFD prior to overseeing any work on any commercial kitchen suppression system. 3. Code/Standard Editions. Commercial kitchen suppression systems shall meet the criteria of the adopted codes as amended and all applicable requirements of the most recent edition of the NFPA standards. NFPA standards are effective on the January 1 st of the year following the effective date printed in the standard. 3. Permits/Inspections. Required plan submittal with approvals, permits and associated inspections must be secured through CSFD. Plan approval and permits shall be secured prior to the start of any work. 4. Special Circumstances. Depending upon the scope of work, different types of submittals may be required; therefore you may want to contact the CSFD for any additional information. 5. Alternative Methods. If special building conditions and/or restrictions exist that may prohibit any of the requirements set forth in this packet from being met, approval from the CSFD for an alternate installation will be required. This alternate method must be approved before any installation of the system begins. 6. Additional Material and Information required to be provided by the contractor. Product information and specifications (cut sheets and or applicable design manual pages) shall be provided for all equipment installed or added to an existing system. 7. Revisions. All revisions shall be clouded and identified with a sequential numbering or lettering system, such as Revision A, B, etcetera or Revision 1, 2, etc. Revisions are date sensitive, thus each revised sheet must bear the date of the revision. II. SUBMITTAL INFORMATION. This section of the packet provides information as to documentation, in addition to the shop drawings, that shall be provided at the time of plan submittal. This documentation is required to assure the plan submittal package contains the necessary information for a complete plan review. Please refer to the checklist available at the end of this packet Colorado Springs Fire Department Page 4 of 11 10/15/13

A. MINIMUM REQUIREMENTS OF THE CSFD FOR SUBMITTAL. 1. Drawings/Plans. Drawings shall be submitted on sheets no less than 11 x 17 inches. Plans shall be scaled or suitably dimensioned and reproducible. Plans shall contain the following information and/or detail indicated in the checklist at the end of this packet. 2. Plan Review Number. Drawings shall be provided with CSFD Plan Review Number. This number is an eight digit numeric code located on the back of the Construction plans. Some projects are system work only so please indicate such and we will issue a plan review number. 3. Number of Drawing Sets. A minimum of 2 sets of drawings are required to be submitted to the CSFD and shall include the items found in the checklist provided with this packet. A maximum of three original sets may be stamped with our approval. 4. Cut Sheets/Specifications. A minimum of 1 set of manufacturer s product information shall be provided. This is to include information on all devices that are part of or being connected to, the commercial kitchen suppression system; such as piping, valves, control heads, nozzles, fusible links, etc. Any cut sheets showing multiple installation/protection methods shall have the specific method used highlighted. As an example, there are several nozzles used to protect fryers, the specific nozzle protection shall be highlighted. Please provide only those pages from the design manual that are applicable to the system. Stamped cut sheets will be returned to the contractor and must remain on the job site with the approved plans. CSFD accepts cut sheets on CD. The CD must have the individual cut sheets for the materials specific to the job. Note: we will not accept manufacturer s CD s! If the option to submit cut sheets via CD is chosen, the CSFD will stamp, date and initial the CD it is then the contractor s responsibility to provide the means of reviewing that disk upon the fire inspector s request. III. GENERAL INFORMATION AND REQUIREMENTS. A. MONITORING. Where a building fire alarm system is provided, commercial kitchen suppression systems shall be monitored by the building fire alarm system. Buildings provided with a waterflow alarm system shall also monitor the commercial kitchen suppression system. Buildings provided with a dedicated function system (such as elevator recall) that is not already monitored, are not required to monitor the commercial kitchen suppression system. The general rule of thumb is, if the building is provided with a monitored panel (other than burglar) the kitchen suppression system must also be monitored. IV. SPECIFIC SYSTEM INFORMATION. A. NEW! APPLIANCES REQUIRING PROTECTION. The adopted International Mechanical Code requires Type 1 hood installations to be provided over medium-, heavy- and extra-heavy-duty appliances. Light duty appliances that produce grease or smoke shall also be provided with a Type 1 Hood. Non-grease or smoke producing appliances exceeding 5860 Watts shall be Colorado Springs Fire Department Page 5 of 11 10/15/13

placed under Type 1 hoods. Additionally, fire suppression systems shall be provided where a Type 1 hood is installed. 1. Medium Duty appliances. Medium duty cooking appliances include electric, discrete element rangers (with or without oven) electric and gas hot-top ranges, electric and gas griddles, electric and gas double-sided griddles, electric and gas fryers (including open deep fat fryers, donut fryers, kettle fryers and pressure fryers), electric and gas conveyor pizza ovens, electric and gas tilting skillets (braising pans) and electric and gas rotisseries. 2. Extra-Heavy Duty Appliances. Extra heavy duty appliances include appliances utilizing solid fuel such as wood, charcoal, briquettes, and mesquite to provide all or part of the heat source for cooking. 3. Heavy Duty Appliances. Heavy duty cooking appliances include electric and gas underfired broilers, electric and gas chain (conveyor) broiler, gas open burner ranges (with or without an oven), electric and gas wok ranges, and electric and gas over-fired (upright) broilers and salamanders. 4. Light Duty Appliances: Light duty appliances include gas and electric ovens, (including standard, bake, roasting, revolving, re-therm, convection, combination convection/steamer, countertop conveyorized baking/finishing, deck and pastry), electric and gas steam-jacketed kettles, electric and gas pasta cookers, electric and gas compartment steamers (both pressure and atmospheric) and electric and gas cheesemelters. B. WET CHEMICAL EXTINGUISHING SYSTEMS. 1. Plans shall be scaled or suitably dimensioned and reproducible. Plans shall contain the information and/or detail indicated in the checklist included at the end of this packet. (NFPA 17A:6.3) 2. Fuel and/or electrical power supply shall be arranged to shut off all cooking equipment AND electrical receptacles located under the hood when the suppression system is actuated. Any receptacles that could be used to power appliances located under the hood shall also be shut down. Shutoff devices shall require manual resetting. (IFC 904.11.2) 3. Where two or more hazards can be simultaneously involved in fire by reason of proximity, the hazards shall be protected by either multiple systems installed to operate simultaneously or one system designed to protected all hazards that can be simultaneously involved. (NFPA 17A:5.6) 4. Exhaust fans are required to remain on, while make-up air is shut down. (IFC 904.11.6.4) 5. Moveable cooking appliances shall be provided with a means to ensure that it is correctly positioned in relation to the appliance discharge nozzle during cooking operations. (NFPA 17A:5.6) 6. At least one manual pull station shall be provided for each system and shall be located in a path of egress (IFC 904.11.1) at least 10- to 20-feet from the kitchen exhaust system. Colorado Springs Fire Department Page 6 of 11 10/15/13

Multiple pull stations shall be provided with signage as to what system they are connected to and/or what appliances/hazards they protect. 7. All deep-fat fryers shall be installed with at least a 16-inch space between the fryer and surface flames from adjacent cooking equipment and not less than 3' from solid fuel cooking equipment. As an alternative a steel or tempered glass baffle may be installed at a minimum of 8-inches in height between the fryer and surface flames of the adjacent appliance; if the fryer and the surface planes are at different horizontal planes, the 8-inch height shall be measured from the higher of the two appliances. (NFPA 96:12.1) 8. Fusible links shall be provided within each exhaust duct opening and above each protected cooking appliance in accordance with the manufacturer s listing (NFPA 17A: 5.6.1) 9. A class K portable fire extinguisher is required for all commercial kitchens equipped with wet chemical fire suppression systems. Extinguishers shall be within 30-feet of appliances as measured along an unobstructed path of egress. Solid fuel cooking appliances may have additional requirements, please refer to 2009 IFC 904.11.5. C. NEW! DRY CHEMICAL EXTINGUISHING SYSTEMS. 1. New Installations are required to meet the testing requirements of UL-300 and shall be listed and labeled for the application. 2. Existing dry chemical systems and pre-ul300 wet chemical systems protecting commercial cooking operations are required to be modified, upgraded or replaced to meet UL 300 requirements where changes in the cooking medium (i.e. from animal fats to vegetable oils), positioning of cooking equipment, or the replacement of cooking equipment occur in existing commercial cooking systems, the extinguishing systems shall comply with the applicable provisions of the adopted IFC. (IFC 904.11.6.1) V. INSTALLATION. A. PERMITS. 1. The installation of the commercial kitchen suppression system is not to commence, including any pre-piping until the working plans have been reviewed and approved by CSFD and a permit secured on site. 2. Permits for fire suppression systems expire one year after date of issue. A 30-day grace period is allowed to renew the permit. After the grace period expires, if inspections have been conducted in the past 13 months, new plans and permit is not required to be submitted. If the grace period has expired and no inspections have occurred in the past 13 months, new plans shall be submitted. 3. When modifications are made to an existing system that does not involve the changing of tank size a permit is not needed. Work such as re-piping for a new appliance arrangement does not require a permit. Any abandoned pipe or conduit from a previous installation shall be removed from within the hood, plenum and exhaust duct. Penetrations and holes resulting from the removal of conduit or piping shall be sealed with Colorado Springs Fire Department Page 7 of 11 10/15/13

listed or equivalent liquidtight sealing devices. If a hood and resulting system are taken down and re-installed, then an inspection is required to confirm control functions and interlock function as intended. Please call Construction Services to discuss your situation. (NFPA 96:10.2.7). 4. If a new hood is being installed, a permit will be required for the modifications to the fire suppression system. 5. Maintenance is defined as the work necessary to keep equipment operable or to make repairs. Replacement of fusible links or repairing damaged components is considered maintenance and does not require a permit. VI. INSPECTIONS AND TESTING. Systems shall undergo an acceptance test witnessed by CSFD. It shall be the duty of the installing contractor to schedule the inspection with their assigned inspector (IFC 901.5). It shall be unlawful to occupy any portion of a building or structure until the required systems have been tested and approved by the CSFD (IFC 901.5.1). A. VISUAL INSPECTION. Piping shall be visually inspected to verify proper materials and installation methods. Nozzles shall be provided with caps to prevent grease, debris or other foreign materials form entering the piping system. Nozzles shall be located per the manufacturer s specification for proper protection of appliances. B. SYSTEMS OPERATIONAL TESTS. A puff test will be required, so please be prepared with the necessary equipment. Please check with your assigned fire inspector for additional information. C. MANUFACTURER S DESIGN MANUAL. The current design manual shall also be available for reference if need be. D. INSTALLERS CERTIFICATION. A completed copy of the completed Dry/Wet Chemical Installer Certification shall be provided at the time of final inspection. REFERENCES AND LINKS Colorado Division of Fire Safety Web site. http://dfs.state.co.us Administrative Rulings and IFC Amendments can be found on the CSFD web site at http://www.springsgov.com/page.aspx?navid=1093 ATTACHMENTS Working Drawing Submittal Checklist Permit Application Colorado Springs Fire Department Page 8 of 11 10/15/13

Title Block shall contain the following: Plan Requirements Working Drawings Name of owner and occupant. Location including full street address as assigned by RBD Enumerations. Name, address, phone, FAX number and email address of installing contractor and designer. CSFD Plan Review number A scale including graphic representation OR suitably dimensioned. Detailed scope of work in narrative format Information required on Drawings: System Information: Type of Hood being protected - canopy, eyebrow, backshelf, etc. Type of Agent being used and amount provided Description of maximum number of flow points supported by the system, and the number of flow points used Description and location of nozzles Size, length and arrangement of connected piping - may be combined with an isometric view Maximum length of pipe, fittings permitted and/or any volume limitations. Location and function of detection devices (fusible links) Equipment schedule or bill of materials. Plan view of the kitchen layout to include exiting. Isometric view of piping to include the nozzles and appliances Details of each unique rigid pipe support configuration showing method of securement to the pipe and to the building structure. Details of the method of container securement showing method to the container and to the building structure. Colorado Springs Fire Department Page 9 of 11 10/15/13

Fire Department Office of the Fire Marshal Commercial Kitchen System Permit Application This form must be completed and attached to the front of plans Initial Review Re-Review Overtime Review 3 rd Party Review Company Name: Project Name: Project Address: Contact Person: Company Phone: Fax Number: E-mail Address: System Information: Hazard Protected: Commercial Cooking Other: Is the System: New Existing Scope of Work: New Installation Modify Existing Replacement Type of System: Wet Dry Other Information to be provided on the plans : CSFD Plan Review Number Equipment Data Sheets Project address Device Legend Designer Address Narrative Scope of Work Plans, Calculations, Cut Sheets signed sealed by RME Project is within the City of Colorado Springs Fire Jurisdiction I attest the above information is provided and accurate; I understand my plans will not be reviewed if any of the items were not provided. Comments: Signature: THIS PLAN IS READY FOR PICK-UP APPROVED/APPROVED AS CORRECTED DISAPPROVED/WITHDRAWN FEES DUE: Reviewer: Withee Embres Other Please do not call our office regarding plan review comments until after pickup and review by your office. Plan Review Status/Comments available online at:www.springsgov.com Follow Links Departments-Fire-Fire Code Enforcement- Plan Review Status-View Plan Review Status Office fo the Fire Marshal, Construction Services, 2880 International Circle Suite 200 Colorado Springs, CO 80910 Phone 719-385-5982 Fax 719-385-7385

** All plans remaining in our office more than 30 days will be discarded as abandoned. Colorado Springs Fire Department Page 2 of 11 10/15/13