Installation. All Refrigerator / All Freezer VCRB5303 / VCRB5363 / CVCRB5303 / CVCRB5363 VCFB5303 / VCFB5363 /CVCFB5303 / CVCFB5363

Similar documents
Viking Installation Guide

Viking Installation Guide

Installation. Built-in Full Height Wine Cellar VCWB301

Viking Installation Guide

INSTALLATION INSTRUCTIONS

Installation GUIDE 5 SERIES. Professional Built-In Bottom-Freezer Refrigerator VCBB5363E / CVCBB5363E

INSTALLATION INSTRUCTIONS

Installation GUIDE 5 SERIES. Side-by-Side Refrigerator/Freezer VCSB5423 / VCSB5483 / FDSB5423 / FDSB5483 CVCSB5423 / CVCSB5483 / FDSB5423 / CFDSB5483

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Viking Installation Guide

Viking Installation Guide

Viking Installation Guide

Installation. Guide. Integrated Refrigerator / Freezer 7 SERIES VBI7360 / CVBI7360 FBI7360 / CFBI7360 MVBI7360 / CMVBI7360 MFBI7360 / CMFBI7360

INSTALLATION INSTRUCTIONS

Viking Installation Guide

Installation Guide. Built-in French Door Bottom-Freezer Refrigerator

Viking Installation Guide

Installation. Guide. 7 SERIES Professional TurboChef Speedcook Double Oven VDOT730

Installation Guide. 15 W./24 W. Undercounter Refrigeration

Installation Guide. 15 W./24 W. Undercounter Refrigeration U L. Viking Range Corporation. 111 Front Street. Greenwood, Mississippi USA

Installation. Counter-Depth Freestanding French Door Bottom-Mount Refrigerator/Freezer

Installation Instructions 36 Inch Refrigerator

Viking Installation Guide

Viking Installation Guide

Viking Installation Guide

Installation. Built-In Electric Cooktop. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation. Professional Built-In Electric Warming Drawers (Indoor and Outdoor Models)

Viking Installation Guide

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Installation. 15 W. / 24 W. Undercounter Refrigeration

Viking Installation Guide

Installation. 3 Series Built-In Electric Cooktop RVEC330 / CRVEC330 RVEC336 / CRVEC336 RVEC345 / CRVEC345

Installation Guide. 15 W. Undercounter/Freestanding Nugget Ice Machine U L. Viking Range, LLC. 111 Front Street

Installation. 15 W. Undercounter/Freestanding Ice Machine FGIM515 / CFGIM515 FPIM515 / CFPIM515

INSTALLATION INSTRUCTIONS ELECTRIC DRYER

Installation GUIDE 5 SERIES. Warming Drawer VWD527 VWD530

GE Monogram. Installation. Instructions. Stainless Steel Bottom Mount Built-In Refrigerators. Models ZICS36N RH ZICS36N LH

Viking Installation Guide

Viking Installation Guide

GUIDE. Installation 5 SERIES. Built-In Electric Cooktops Built-In Induction Cooktops

Undercounter Refrigeration

Viking Installation Guide

36 Inch Built-In Refrigerator

Installation Instructions

Installation Guide. Built-In Electric Cooktops Built-In Induction Cooktops

Installation Instructions

Viking Installation Guide

PRO 48 INSTALLATION INSTRUCTIONS

Installation Instructions

Installation GUIDE 6 SERIES. Built-in Electric Single and Double Wall Ovens MVSOE630 / CMVSOE630 MVDOE630 / CMVDOE630

Viking Installation Guide

Installation Instructions Built-In Refrigerator

Viking Installation Guide

Installation Instructions

Installation Guide. 5 Series Professional Built-In Electric Single and Double Ovens 7 Series Professional Built-in Electric Double French Door Oven

Installation. Freestanding 30 Gas Self-Clean Sealed Burner Range

Installation Guide. 5 Series VGC and VGSU Built-In Gas Cooktops

Viking Installation Guide

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

Viking Installation Guide

Installation. 3 Series Freestanding 30 Dual Fuel Self-Clean Sealed Burner Range

Installation. Professional Freestanding Sealed Burner Gas Ranges VGCC530 / VGCC536 / VGCC548 / VGCC560 CVGCC530 / CVGCC536 / CVGCC546 / CVGCC560

Viking Installation Guide

200 IG qxd 1/2/2004 7:55 AM Page S E R I E S I N S T A L L A T I O N G U I D E

Installation. Professional Freestanding Dual Fuel Ranges VDSC530 / VDSC536 / VDSC548 / VDSC560 CVDSC530 / CVDSC536 / CVDSC548

DESIGN CLASS FUNCTION

29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS DRYER SAFETY

Installation Instructions

GUIDE. Installation. Tuscany Freestanding Dual Fuel Ranges

Installation. Professional Freestanding Open Burner Ranges VGIC5301, CVGIC5301, VGIC5361, CVGIC5361

Installation Instructions 30 French Door Built-in Wall Ovens

2008 DOUBLE DRAWER UNDER COUNTER REFRIGERATOR / FREEZER PRODUCTS

Installation Instructions

Tuscany Freestanding Dual Fuel Ranges

Installation Instructions. Instructions de montage. Instrucciones de instalación HC

BUILT-IN MICROWAVE OVEN INSTALLATION INSTRUCTIONS 24" (61.0 cm), 27" (68.6 cm), 30" (76.2 cm)

Installation Instructions

Viking Installation Guide

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Installation Instructions

Installation. Professional Built-In Electric Single and Double Ovens. Professional Built-In Electric Single and Double French Door Ovens

INSTALLATION INSTRUCTIONS UNDERCOUNTER DISHWASHERS

Installation Instructions

EF36, IF36 PLANNING GUIDE. 36 Wide Built-In Refrigerator. (1.3 cm) 1/8. Opening Dimensions

ICE MAKER Use & Care Guide. Table of Contents... 2

Viking Installation Guide

Installation. Leveling

Washer. 120~volt 60-Hz. IhilPORTANT: Read and save these instructions. Parts supplied:

Viking Installation Guide

Installation. Professional Freestanding Ranges

Installation Instructions

Liebherr's engineering excellence in Germany provides the largest selection of freezers, refrigerators and wine refrigerators worldwide.

Installation Instructions

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions

Installation Instructions

Transcription:

Installation All Refrigerator / All Freezer VCRB5303 / VCRB5363 / CVCRB5303 / CVCRB5363 VCFB5303 / VCFB5363 /CVCFB5303 / CVCFB5363

Table of Contents Warnings & Important Information _ 2 Professional Dimensions & Specifications (30 & 36 ) _ 4 Dimensions & Specifications (30 & 36 with flush mount trim) _ 6 Cutout Dimensions (30 ) _ 8 Anti-Tip Dimensions (30 ) 9 Cutout Dimensions (36 ) 10 Anti-Tip Dimensions (36 ) _ 11 Dimensions & Specifications (Dual 30 / Dual 30 & 36 ) 12 Dimensions & Specifications (Dual 30 / Dual 30 & 36 with flush mount trim) _ 16 Cutout Dimensions (Dual 30 ) 20 Anti-Tip Dimensions (Dual 30 ) _ 21 Cutout Dimensions (Dual 30 & 36 ) 22 Anti-Tip Dimensions (Dual 30 & 36 ) _ 23 Cutout Dimensions (Dual 36 ) 24 Anti-Tip Dimensions (Dual 36 ) _ 25 Cabinet Information 26 Cabinet Information (with flush mount trim) 28 Custom Side Panel Dimensions 30 Custom Side Panel Dimensions (with flush mount trim) 31 General Information 33 Unpacking & Moving 34 Flush Mount Side Trim Installation 35 Installation _ 35 Hinge Adjustment 36 Kickplate Installation 38 Door Stop Adjustment 39 Final Installation 39 Performance Checklist 41 Control Panels _ 42 Service & Registration _ 43 Your safety and the safety of others is very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol. This symbol alerts you to hazards that can kill or hurt you and others. All safety messages will be preceded by the safety alert symbol and the word DANGER or WARNING. These words mean: DANGER You will be killed or seriously injured if you don t follow instructions. WARNING You can be killed or seriously injured if you don t follow instructions. All safety messages will identify the hazard, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed. 2

IMPORTANT Please Read and Follow! Make sure that incoming voltage is the same as unit rating. An electric rating plate specifying voltage, frequency, wattage, amperage, and phase is attached to the product. To reduce the risk of fire, electric shock, or injury to persons, installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards, including fire-rated construction. The installer should leave these instructions with the consumer who should retain them for local inspector s use and for future reference. A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances. The required use of a GFI is normally related to the location of a receptacle with respect to any significant sources of water or moisture. Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the requirements below. If the use of a GFI is required, it should be: Of the receptacle type (breaker type or portable type NOT recommended) Used with permanent wiring only (temporary or portable wiring NOT recommended) On a dedicated circuit (no other receptacles, switches or loads in the circuit) Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended) Rated for Class A (5 ma +/- 1 ma trip current) as per UL 943 standard) In good condition and free from any loose-fitting gaskets (if applicable in outdoor situations) Protected from moisture (water, steam, high humidity) as much as reasonably possible It is your responsibility to: comply with installation specifications and dimensions. properly install unit. remove any moldings or decorative panels that prevent the unit from being serviced. make sure that you have these materials (not provided with your unit), which are necessary for proper installation: 1/4 (6 mm) copper tubing with shutoff valve 6 #8 x 3 (7.6 cm) wood screws (longer screws may be required) 1 Saddle valve (do not use self-piercing feature of the valve) assure that floor will support unit, door panels and contents (approximately 1200 pounds [540 kg]). provide a properly grounded electrical outlet. assure that location will permit appliance doors to open 90 minimum. WARNING WARNING ELECTRICAL SHOCK HAZARD Disconnect power or turn power disconnect switch to OFF position before removing top grille. Failure to do so can result in death or electrical shock. Most of the unit s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface. TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Use two or more people to move and install appliance. Failure to do so can result in death or serious injury. 3

Dimensions 30 All Refrigerator/All Freezer 3 19/32 (9.1 cm) 30 (76.2 cm) 29 (73.7 cm) 9 5/32 (23.3 cm) 36 All Refrigerator/All Freezer 3 19/32 (9.1 cm)) 36 (91.5 cm) 35 (88.9 cm) 9 5/32 (23.3 cm) 82 3/4 75 15/16 (192.9 cm) 26-1/2 (67.3 cm) (210.2 cm) min. to 84 1/16 (213.5 cm) max. 82 3/4 75 15/16 (192.9 cm) 26-1/2 (67.3 cm) (210.2 cm) min. to 84 1/16 (213.5 cm) max. 20 3/4 (52.7 cm) 22 3/16 (56.4 cm) 24 (61.0 cm) 20 3/4 (52.7 cm) 22 3/16 (56.4 cm) 24 (61.0 cm) 4

Specifications 30 All Refrigerator/All Freezer Description VCFB/CVCFB VCRB/CVCRB Overall width 30 (76.2 cm) Overall height from bottom 82-3/4 (210.2 cm) min. to 84-1/16 (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16 (56.4 cm) To front of top grille: 24 (61.0 cm) To front of handle endcap: 26-1/2 (67.3 cm) Cutout width 29-5/8 (75.2 cm) min. to 29-3/4 (75.6 cm) max. Cutout height 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max. Cutout depth 24 (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4 copper tubing inlet waterline; minimum 20 psi; N/A maximum 120 psi Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 17.8 cu. ft. (504 liters) Approximate shipping weight 550 lbs. (247.5 kg) 525 lbs. (236.3 kg) 36 All Refrigerator/All Freezer Description VCFB/CVCFB VCRB/CVCRB Overall width 36 (91.5 cm) Overall height from bottom 82-3/4 (210.2 cm) min. to 84-1/16 (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16 (56.4 cm) To front of top grille: 24 (61.0 cm) To front of handle endcap: 26-1/2 (67.3 cm) Cutout width 35-5/8 (90.5 cm) min. to 35-3/4 (90.8 cm) max. Cutout height 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max. Cutout depth 24 (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4 copper tubing inlet waterline; minimum 20 psi; N/A maximum 120 psi Overall interior dimensions Total capacity 19.2 cu. ft. (544 liters) 22.0 cu. ft. (623 liters) Approximate shipping weight 605 lbs. (272.3 kg) 590 lbs. (265.5 kg) 5

Dimensions 30 All Refrigerator/All Freezer with Flush Mount Trim 3 19/32 (9.1 cm) 30 (76.2 cm) 29 (73.7 cm) 9 5/32 (23.3 cm) 36 All Refrigerator/All Freezer with Flush Mount Trim 3 19/32 (9.1 cm) 36 (91.5 cm) 35 (88.9 cm) 9 5/32 (23.3 cm) 82 3/4 75 15/16 (192.9 cm) 26 1/2 (67.3 cm) (210.2 cm) min. to 84 1/16 (213.5 cm) max. 82 3/4 75 15/16 (192.9 cm) 26 1/2 (67.3 cm) (210.2 cm) min. to 84 1/16 (213.5 cm) max. 20 3/4 (52.7 cm) 23 3/8 (59.4 cm) 24 (61.0 cm) Note: Flush Mount Trim (PBIRFTKSS) purchased separately. 20 3/4 (52.7 cm) 23 3/8 (59.4 cm) 24 (61.0 cm) 6

Specifications 30 All Refrigerator/All Freezer with Flush Mount Trim Description VCFB/CVCFB Flush Mount VCRB/CVCRB Flush Mount Overall width 30 (76.2 cm) Overall height from bottom 82-3/4 (210.2 cm) min. to 84-1/16 (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8 (59.4 cm) To front of top grille: 24 (61.0 cm) To front of handle endcap: 26-1/2 (67.3 cm) Cutout width 30 (74.9 cm) Cutout height 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max. Cutout depth 24 (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product Maximum amp usage 9.1 amps 5.7 amps Inlet water requirements 1/4 copper tubing inlet waterline; minimum 20 psi; N/A maximum 120 psi Overall interior dimensions Total capacity 15.9 cu. ft. (450 liters) 17.8 cu. ft. (504 liters) Approximate shipping weight 550 lbs. (247.5 kg) 525 lbs. (236.3 kg) 36 All Refrigerator/All Freezer with Flush Mount Trim Description VCFB/CVCFB Flush Mount VCRB/CVCRB Flush Mount Overall width 36 (91.5 cm) Overall height from bottom 82-3/4 (210.2 cm) min. to 84-1/16 (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8 (59.4 cm) To front of top grille: 24 (61.0 cm) To front of handle endcap: 26-1/2 (67.3 cm) Cutout width 36 (91.4 cm) Cutout height 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max. Cutout depth 24 (61.0 cm) min. Electrical requirements 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product Maximum amp usage 9.5 amps 6.5 amps Inlet water requirements 1/4 copper tubing inlet waterline; minimum 20 psi; N/A maximum 120 psi Overall interior dimensions Total capacity 19.2 cu. ft. (544 liters) 22.0 cu. ft. (623 liters) Approximate shipping weight 605 lbs. (272.3 kg) 590 lbs. (265.5 kg) 7

Cutout Dimensions 30 All Refrigerator/All Freezer 24 (61.0 cm) See Anti-Tip board installation Electric Outlet Location 6 (15.2 cm) 9 (22.9 cm) 9 (22.9 cm) 82 7/8 (210.5 cm) min. anti-tip board & opening height 84 1/16 (213.5 cm) max. anti-tip board & opening height 73 3/8 (186.4 cm) Water Line Entry Area Note: Shown for All Freezer Only 30 (76.2 cm) Flush Mount only 29 5/8 (75.2 cm) 29 5/8 5/8 (1.5 cm) 7 5/8 (19.4 cm) 3 (7.6 cm) 6 3/4 (17.1 cm) (75.2 cm) min. to 29-3/4 (75.6 cm) max. 30 (76.2 cm) Flush Mount only 3 5/8 (9.2 cm) 10 3/4 (27.3 cm) 10 1/2 (26.7 cm) 5/8 (1.5 cm) 5/8 (1.5 cm) 1 (2.5 cm) Optional floor water line entry 8

Anti-Tip Dimensions 30 All Refrigerator/All Freezer Anti-Tip Location Two 2 x 4 mounting boards 3 (7.6 cm) x 3-1/2 (8.9 cm) 3 (7.6 cm) 23 (58.4 cm) 3 1/2 (8.9 cm) 79 3/8 (201.6 cm) min. to bottom of anti-tip board 80 1/2 (204.6 cm) max. to bottom of anti-tip board NOTE: If unit is installed deeper than 24 (61.0 cm),then shim behind the mounting board by the difference. Flush Mount Anti-Tip Location One 2 x 4 mounting board 1 1/2 (3.8 cm) x 3-1/2 (8.9 cm) 1 1/2 (3.8 cm) 23 (58.4 cm) 3 1/2 (8.9 cm) Bottom of anti-tip board is 3 7/8 (9.8 cm) below opening height. Note: Top of unit must be placed firmly under anti-tip board. NOTE: If unit is installed deeper than 24 (61.0 cm), then shim behind the mounting board by the difference. 9

Cutout Dimensions 36 All Refrigerator/All Freezer 24 (61.0 cm) See Anti-Tip board installation Electric Outlet Location 9 (22.9 cm) 6 (15.2 cm) 9 (22.9 cm) 82 7/8 (210.5 cm) min. anti-tip board & opening height 84 1/16 (213.5 cm) max. anti-tip board & opening height 73 3/8 (186.4 cm) Water Line Entry Area Note: Shown for All Freezer Only 36 (91.4 cm) Flush Mount only 35 5/8 (90.5 cm) 35 5/8 5/8 (1.5 cm) 7 5/8 (19.4 cm) 3 (7.6 cm) 6 3/4 (17.1 cm) (90.5 cm) min. to 35-3/4 (90.8 cm) max. 36 (91.4 cm) Flush Mount only 3 5/8 (9.2 cm) 10 3/4 10 1/2 5/8 (1.5 cm) 1 (2.5 cm) (27.3 cm) (26.7 cm) 5/8 (1.5 cm) Optional floor water line entry 10

Anti-Tip Dimensions 36 All Refrigerator/All Freezer Anti-Tip Location Two 2 x 4 mounting boards 3 (7.6 cm) x 3-1/2 (8.9 cm) 3 (7.6 cm) 29 1/2 (74.9 cm) 3 1/2 (8.9 cm) 79 3/8 (201.6 cm) min. to bottom of anti-tip board 80 1/2 (204.6 cm) max. to bottom of anti-tip board NOTE: If unit is installed deeper than 24 (61.0 cm), then shim behind the mounting board by the difference. Flush Mount Anti-Tip Location One 2 x 4 mounting board 1 1/2 (3.8 cm) x 3 1/2 (8.9 cm) 1 1/2 (3.8 cm) 29 1/2 (74.9 cm) 3 1/2 (8.9 cm) Bottom of anti-tip board is 3 7/8 (9.8 cm) below opening height. Note: Top of unit must be placed firmly under anti-tip board. NOTE: If unit is installed deeper than 24 (61.0 cm), then shim behind the mounting board by the difference. 11

Dimensions Dual 30 All Refrigerator/All Freezer* 3 19/32 (9.1 cm) 30 30 (76.2 cm) (76.2 cm) 29 (73.7 cm) 30 30 (76.2 cm) (76.2 cm) 29 (73.7 cm) 9 5/32 (23.3 cm) 75 15/16 (192.9 cm) 82 3/4 26-1/2 (67.3 cm) (210.2 cm) min. to 84 1/16 (213.5 cm) max. 1 (2.54 cm) Between Units 20 3/4 (52.7 cm) 22 3/16 (56.4 cm) 24 (61.0 cm) *Shown with optional one-piece grille kit 12

Dimensions Dual 30 & 36 All Refrigerator/All Freezer* 29 (73.6 cm) 3 19/32 (9.1 cm) 30 (76.2 cm) 30 (76.2 cm) 36 (91.5 cm) 35 (88.9 cm) 9 5/32 (23.3 cm) 75 15/16 (192.9 cm) 82 3/4 26-1/2 (67.3 cm) (210.2 cm) min. to 84 1/16 (213.5 cm) max. 1 (2.54 cm) Between Units 20 3/4 (52.7 cm) 22 3/16 (56.4 cm) 24 (61.0 cm) *Shown with optional one-piece grille kit 13

Dimensions Dual 36 All Refrigerator/All Freezer* 3 19/32 (9.1 cm) 30 (76.2 cm) 36 (91.5 cm) 35 (88.9 cm) 30 36 (76.2 cm) (91.5 cm) 35 (88.9 cm) 9 5/32 (23.3 cm) 75 15/16 (192.9 cm) 82 3/4 26-1/2 (67.3 cm) (210.2 cm) min. to 84 1/16 (213.5 cm) max. 1 (2.54 cm) Between Units *Shown with optional one-piece grille kit 20 3/4 (52.7 cm) 22 3/16 (56.4 cm) 24 (61.0 cm) 14

Specifications Dual All Refrigerator/All Freezer* Description (2) 30 Units (1) 36 & (1) 30 Unit (2) 36 Units Overall width 60 (152.4 cm) 66 (167.6 cm) 72 (182.9 cm) Overall height from bottom 82-3/4 (210.2 cm) min. to 84-1/16 (213.5 cm) max. Overall depth from rear To front edge of side trim: 22-3/16 (56.4 cm) To front of top grille: 24 (61.0 cm) To front of handle endcap: 26-1/2 (67.3 cm) Cutout width 59-5/8 (151.4 cm) 65-5/8 (166.7 cm) 71-5/8 (181.9 cm) Cutout height 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max. Cutout depth 24 (61.0 cm) min. Electrical requirements (2) 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product Maximum amp usage 30 Freezer 9.1 amps per unit 30 Refrigerator 5.7 amps per unit 36 Freezer 9.5 amps per unit 36 Refrigerator 6.5 amps per unit Inlet water requirements 1/4 copper tubing inlet waterline; minimum 20 psi; (All Freezer only) maximum 120 psi Overall interior dimensions 30 Freezer 15.9 cu. ft. (450 liters) 30 Refrigerator 17.8 cu. ft. (504 liters) 36 Freezer 19.2 cu. ft. (544 liters) 36 Refrigerator 22.0 cu. ft. (623 liters) Approximate shipping weight 30 - Freezer 550 lbs. (247.5 kg) each; Refrigerator 525 lbs. (236.3 kg) each 36 - Freezer 605 lbs. (272.3 kg) each; Refrigerator 590 lbs. (265.5 kg) each *For installation of two units side-by-side, a separate grille kit accessory must be purchased. 15

Dimensions Dual 30 All Refrigerator/All Freezer with Flush Mount Trim* Note: Flush Mount Trim Kit (PBIRFTK) purchased separately 3 19/32 (9.1 cm) 30 29 (73.7 cm) (76.2 cm) 30 (76.2 cm) 29 (73.7 cm) 9 5/32 (23.3 cm) 75 15/16 (192.9 cm) 26-1/2 (67.3 cm) 82 3/4 (210.2 cm) min. to 84 1/16 (213.5 cm) max. 1 (2.54 cm) Between Units 20 3/4 (52.7 cm) 23 3/8 (59.4 cm) 24 (61.0 cm) *Shown with optional one-piece grille kit 16

Dimensions Dual 30 & 36 All Refrigerator/All Freezer with Flush Mount Trim* Note: Flush Mount Trim Kit (PBIRFTK) purchased separately 29 (73.6 cm) 3 19/32 (9.1 cm) 30 (76.2 cm) 30 (76.2 cm) 36 (91.5 cm) 35 (88.9 cm) 9 5/32 (23.3 cm) 75 15/16 (192.9 cm) 82 3/4 26-1/2 (67.3 cm) (210.2 cm) min. to 84 1/16 (213.5 cm) max. 1 (2.54 cm) Between Units 20 3/4 (52.7 cm) 23 3/8 (59.4 cm) 24 (61.0 cm) *Shown with optional one-piece grille kit 17

Dimensions Dual 36 All Refrigerator/All Freezer with Flush Mount Trim* Note: Flush Mount Trim Kit (PBIRFTK) purchased separately 3 19/32 (9.1 cm) 36 35 (88.9 cm) (91.5 cm) 36 (91.5 cm) 35 (88.9 cm) 9 5/32 (23.3 cm) 75 15/16 (192.9 cm) 26-1/2 (67.3 cm) 82 3/4 (210.2 cm) min. to 84 1/16 (213.5 cm) max. 1 (2.54 cm) Between Units 20 3/4 (52.7 cm) 23 3/8 (59.4 cm) 24 (61.0 cm) *Shown with optional one-piece grille kit (purchased separately) 18

Specifications Dual All Refrigerator/All Freezer w/flush Mount Trim* Description (2) 30 Units (1) 36 & (1) 30 Unit (2) 36 Units Overall width 60 (152.4 cm) 66 (167.6 cm) 72 (182.9 cm) Overall height from bottom 82-3/4 (210.2 cm) min. to 84-1/16 (213.5 cm) max. Overall depth from rear To front edge of side trim: 23-3/8 (59.4 cm) To front of top grille: 24 (61.0 cm) To front of handle endcap: 26-1/2 (67.3 cm) Cutout width 60 (152.4 cm) 66 (167.6 cm) 72 (182.9 cm) Cutout height 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max. Cutout depth 24 (61.0 cm) min. Electrical requirements (2) 115 volt, 60 Hz, 15 amp dedicated circuit; 3-wire cord with grounded 3-prong plug attached to product Maximum amp usage 30 Freezer 9.1 amps per unit 30 Refrigerator 5.7 amps per unit 36 Freezer 9.5 amps per unit 36 Refrigerator 6.5 amps per unit Inlet water requirements 1/4 copper tubing inlet waterline; minimum 20 psi; (All Freezer only) maximum 120 psi Overall interior dimensions 30 Freezer 15.9 cu. ft. (450 liters) 30 Refrigerator 17.8 cu. ft. (504 liters) 36 Freezer 19.2 cu. ft. (544 liters) 36 Refrigerator 22.0 cu. ft. (623 liters) Approximate shipping weight 30 - Freezer 550 lbs. (247.5 kg) each; Refrigerator 525 lbs. (236.3 kg) each 36 - Freezer 605 lbs. (272.3 kg) each; Refrigerator 590 lbs. (265.5 kg) each *For installation of two units side-by-side, a separate grille kit accessory must be purchased. 19

Cutout Dimensions Dual 30 All Refrigerator/All Freezer 24 (61.0 cm) See Anti-Tip board installation Electric Outlet Location 6 (15.2 cm) 9 (22.9 cm) 9 (22.9 cm) (210.5 cm) min. anti-tip board & opening height 73 3/8 (186.4 cm) 82 7/8 84 1/16 (213.5 cm) max. anti-tip board & opening height Water Line Entry Area Note: Cutout opening shown with All Freezer model on left. Reverse water line entry if All Freezer model is on right. 60 (152.4 cm) Flush Mount only 59 5/8 (151.4 cm) 60 (152.4 cm) Flush Mount only 5/8 (1.5 cm) 3 5/8 (9.2 cm) 7 5/8 6 3/4 (19.4 cm) (17.1 cm) 3 (7.6 cm) 59 5/8 (151.4 cm) 5/8 (1.5 cm) 10 3/4 (27.3 cm) Optional floor water line entry 10 1/2 (26.7 cm) 5/8 (1.5 cm) 1 (2.5 cm) 20

Anti-Tip Dimensions Dual 30 All Refrigerator/All Freezer Anti-Tip Location Two 2 x 4 mounting boards per unit 3 (7.6 cm) x 3 1/2 (8.9 cm) 23 (58.4 cm) 3 (7.6 cm) 23 (58.4 cm) 79 3/8 (201.6 cm) min. 3 1/2 (8.9 cm) to bottom of anti-tip board 80 1/2 (204.6 cm) max. to bottom of anti-tip board Note: If unit is installed deeper than 24 (61.0 cm), then shim behind the anti-tip bracket by the difference. Flush Mount Anti-Tip Location One 2 x 4 mounting board per unit 1 1/2 (3.8 cm) x 3 1/2 (8.9 cm) 23 (58.4 cm) 1 1/2 (3.8 cm) 23 (58.4 cm) Bottom of anti-tip board is 3 7/8 (9.8 cm) below opening height. Note: Top of unit must be placed firmly under anti-tip board. 3 1/2 (8.9 cm) Note: If unit is installed deeper than 24 (61.0 cm), then shim behind the anti-tip bracket by the difference. 21

Cutout Dimensions 24 (61.0 cm) See Anti-Tip board installation Dual 30 & 36 All Refrigerator/All Freezer Electric Outlet Location 6 (15.2 cm) 9 (22.9 cm) 9 (22.9 cm) 82 7/8 (210.5 cm) min. anti-tip board & opening height 73 3/8 (186.4 cm) 84 1/16 (213.5 cm) max. anti-tip board & opening height Water Line Entry Area Note: Cutout opening shown with All Freezer model on left. Reverse water line entry if All Freezer model is on right. 66 (167.6 cm) Flush Mount only 65 5/8 (166.7 cm) 66 (167.6 cm) Flush Mount only 7 5/8 6 3/4 (19.4 cm) (17.1 cm) 5/8 (1.5 cm) 3 (7.6 cm) 65 5/8 (166.7 cm) 3 5/8 (9.2 cm) 5/8 (1.5 cm) 10 3/4 (27.3 cm) Optional floor water line entry 10 1/2 (26.7 cm) 5/8 (1.5 cm) 1 (2.5 cm) 22

Anti-Tip Dimensions Dual 30 & 36 All Refrigerator/All Freezer Anti-Tip Location Two 2 x 4 mounting boards per unit 3 (7.6 cm) x 3 1/2 (8.9 cm) 79 3/8 (201.6 cm) min. 29 (73.7 cm) 3 (7.6 cm) 23 (58.4 cm) to bottom of anti-tip board 3 1/2 (8.9 cm) 80 1/2 (204.6 cm) max. to bottom of anti-tip board Note: If unit is installed deeper than 24 (61.0 cm), then shim behind the mounting boards by the difference. Flush Mount Anti-Tip Location One 2 x 4 mounting board per unit 1 1/2 (3.8 cm) x 3 1/2 (8.9 cm) Bottom of anti-tip board is 3 7/8 (9.8 cm) below opening height. Note: Top of unit must be placed firmly under anti-tip board. 29 (73.7 cm) 1 1/2 (3.8 cm) 23 (58.4 cm) Note: Dimensions shown for 36 AF/AR model on the left. Reverse mounting boards if units are installed on the right. 3 1/2 (8.9 cm) Note: If unit is installed deeper than 24 (61.0 cm), then shim behind the mounting boards by the difference. 23

Cutout Dimensions Dual 36 All Refrigerator/All Freezer 24 (61.0 cm) See Anti-Tip board installation Electric Outlet Location 6 (15.2 cm) 9 (22.9 cm) 9 (22.9 cm) 82 7/8 (210.5 cm) min. anti-tip board & opening height 73 3/8 (186.4 cm) 84 1/16 (213.5 cm) max. anti-tip board & opening height Water Line Entry Area Note: Cutout opening shown with All Freezer model on left. Reverse water line entry if All Freezer model is on right. 72 (182.8 cm) Flush Mount only 71 5/8 (181.9 cm) 72 (182.8 cm) Flush Mount only 5/8 (1.5 cm) 7 5/8 6 3/4 (19.4 cm) (17.1 cm) 3 (7.6 cm) 71 5/8 (181.9 cm) 3 5/8 (9.2 cm) 5/8 (1.5 cm) 10 3/4 (27.3 cm) Optional floor water line entry 10 1/2 (26.7 cm) 5/8 (1.5 cm) 1 (2.5 cm) 24

Anti-Tip Dimensions Dual 36 All Refrigerator/All Freezer Anti-Tip Location Two 2 x 4 mounting boards per unit 3 (7.6 cm) x 3 1/2 (8.9 cm) 79 3/8 (201.6 cm) min. 29 (73.7 cm) 3 (7.6 cm) 29 (73.7 cm) to bottom of anti-tip board 3 1/2 (8.9 cm) 80 1/2 (204.6 cm) max. to bottom of anti-tip board Note: If unit is installed deeper than 24 (61.0 cm), then shim behind the mounting boards by the difference. Flush Mount Anti-Tip Location One 2 x 4 mounting board per unit 1 1/2 (3.8 cm) x 3 1/2 (8.9 cm) Bottom of anti-tip board is 3 7/8 (9.8 cm) below opening height. Note: Top of unit must be placed firmly under anti-tip board. 29 (73.7 cm) 1 1/2 (3.8 cm) 3 1/2 (8.9 cm) 29 (73.7 cm) Note: If unit is installed deeper than 24 (61.0 cm), then shim behind the mounting boards by the difference. 25

Cabinet Information Professional models fit semi-flush in standard 24 (61.0 cm) deep cabinet openings. The door face protrudes 1-3/4 (4.4 cm) from the cabinet face. The handle protrudes an additional 2-1/2 (6.4 cm) into the room. Top View Wall 1 13/16 (4.6 cm) Space if 24 (61.0 cm) standard cabinet depth is used 3/4 (1.9 cm) Full end panel 24 (61.0 cm) Standard cabinet depth Countertop overhang Top View Wall Door 1-3/4 (4.4 cm) Offset 24 (61.0 cm) Standard cabinet depth 1 13/16 (4.6 cm) Space if 24 (61.0 cm) standard cabinet depth is used 3/4 (1.9 cm) Full end panel 5 16 (0.8 cm) Door 1-3/4 (4.4 cm) Offset 26

Cabinet Information Professional models fit semi-flush in standard 24 (61.0 cm) deep cabinet openings. The door face protrudes 1-3/4 (4.4 cm) from the cabinet face. The handle protrudes an additional 2-1/2 (6.4 cm) into the room. Top View Wall 1 13/16 (4.6 cm) Space if 24 (61.0 cm) standard cabinet depth is used 3/4 (1.9 cm) Full end panel 24 (61.0 cm) Standard cabinet depth Partial overlay cabinet door Door 1-3/4 (4.4 cm) Offset 27

Cabinet Information (With Flush Mount Trim) Models with flush mount trim fit flush in standard 24 (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2 (6.4 cm) into the room. Top View Wall 1 (2.5 cm) space if 25 (63.5 cm) cabinet depth is used 3/4 (1.9 cm) Full end panel 25 (63.5 cm) countertop depth 24 (61.0 cm) Standard cabinet depth Door Top View Flush Wall 1 (2.5 cm) space if 25 (63.5 cm) cabinet depth is used 25 (63.5 cm) 3/4 (1.9 cm) Full end panel Door Flush 28

Cabinet Information (With Flush Mount Trim) Models with flush mount trim fit flush in standard 24 (61.0 cm) deep cabinet openings with no protrusion into the room except the handle protrudes 2-1/2 (6.4 cm) into the room. Top View Overlapping cabinet doors Wall 3/4 (1.9 cm) space if 24 (61.0 cm) standard cabinet depth is used 3/4 (1.9 cm) Full end panel 24 (61.0 cm) Standard cabinet depth 24-3/4 (62.9 cm) Door Cabinet door Flush Top View Flush mount cabinet doors Wall 1 (2.5 cm) space if 25 (63.5 cm) cabinet depth is used 3/4 (1.9 cm) Full end panel 25 (63.5 cm) Cabinet depth Door Cabinet door Flush 29

Custom Side Panel Dimensions 3/16 (0.5 cm) Back filler panel 3/4 (1.9 cm) End panel 22-7/16 (57.0 cm) 6 (15.2 cm) 5/32 (0.4 cm) 22-7/16 (57.0 cm) 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max.* 82-7/8 6 (15.2 cm) (210.5 cm) min. to 84-1/16 (213.5 cm) max.* 22-1/4 (56.5 cm) Optional kickplate notch Dimensions determined by cabinets 22-1/4 (56.5 cm) * Depending on how high leveling feet are raised, and cabinet enclosure height. 30

Custom Side Panel Dimensions (With Flush Mount Trim) 21-3/4 (55.2 cm) Z-Bracket 1 (2.5 cm) 1/4 (0.6 cm) 3/4 (1.9 cm) End panel 21-3/4 (55.2 cm) 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max.* 82-7/8 (210.5 cm) min. to 84-1/16 (213.5 cm) max.* 24 (61.0 cm) Optional kickplate notch Dimensions determined by cabinets 24 (61.0 cm) * Depending on how high leveling feet are raised, and cabinet enclosure height. 31

General Information Area Requirements Verify the following: Unit can fit into residence and can be moved around corners and through doorways. Floors can support unit s weight plus food weight (approximately 1200 pounds [540 kg] per unit). Floors underneath appliance are level with surrounding finished floor. Rear wall is solid and is able to support two horizontally mounted 2 X 4s (included) bolted to two wall studs. The 2 X 4 board bolt heads must be flush with 2 X 4 to prevent obstruction. Remove anything attached to rear or side walls that can obstruct unit installation. Cutout dimensions are accurate. Electrical outlet is in correct location. Water line is in correct location. Do not install a refrigeration unit near a heat source, nor in a location where the surrounding temperature will fall below 60º F (16º C). It is required that a separate circuit serving only this appliance be provided. This appliance is equipped with a power supply cord having a 3-prong grounding plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong, grounding-type wall receptacle. Do not use an extension cord. If codes permit a separate grounding wire to be used, it is recommended that a qualified electrician determine that the grounding path is adequate. DO NOT ground to a gas pipe. Check with a qualified electrician if you are not sure the appliance is properly grounded. DO NOT have a fuse in the neutral or grounding circuit. Anti-Tip Requirements The anti-tip boards should be fastened into position prior to moving the unit into the opening. Note: Additional mounting boards may be required if the unit does not touch the back wall of the enclosure. To prevent unit from tipping forward, it must be secured in place with a solid soffit or wood block. Electrical Requirements It is the customer s responsibility to: contact a qualified electrical installer. assure that the electrical installation is adequate and in conformance with the National Electrical Code, ANSI/NFPA 70- latest edition or Canadian Electrical Code C22.1-1998 and C22.2 No. 0-M91 (or latest edition), and all local codes and ordinances. A 115 volt, 60-Hz, 15 amp, fused, electrical supply is required. 32

General Information Water Supply Requirements (All Freezer) WARNING To avoid serious illness or death, do not use unit where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts. The contaminants or other substances removed or reduced by this water treatment system are not necessarily in you water. Use only 1/4 (6 mm) copper tubing for water line. Do Not install copper tubing in area where temperatures drop below 35 F (1.7 C). Before attaching copper tubing to the unit, flush at least 2 quarts (1.9 L) of water through the copper tubing and into a bucket to remove any particles in the water line. Viking Range, LLC is not responsible for property damage due to improper installation or water connection. Connect 1/4 (6 mm) flexible copper tubing to household plumbing in compliance with local codes and ordinances. Length of copper tubing must reach from water supply connection to the unit connection with an additional length to facilitate moving the unit out of enclosure for cleaning or service. Tubing should be soft instead of rigid and ends should be free of burrs. Copper tubing route must be above 35 F (1.7 C) to prevent water line from freezing. Do not use plastic water lines from the household plumbing to the water inlet valve connection on the unit. Do not use the self-piercing feature of a saddle valve. The hole made by the piercing lance is too small for the water flow rate required by the ice maker. If saddle valve is not used, place a separate shut-off valve in an easily accessible location between water supply and the unit. Do not locate shut-off valve behind the unit. The installation of Viking units with a reverse osmosis system is acceptable as long as the water pressure remains within the allowable PSI as stated below. It is important to note that with many reverse osmosis systems, the pressure starts off high, but then it decreases as the water level of the reverse osmosis storage area drops. This must be considered when checking the water pressure coming into the unit. Connect a vertical or horizontal 1/2 (1.2 cm) to 1-1/4 (3.2 cm) COLD water line near water area. Run water line through the floor, back, or side wall. Tubing should lay flat on floor underneath the unit. Clamp tubing to wall or floor. Water pressure must be greater than 20 psi and less than 120 psi on non-dispensers and greater than 35 psi and less than 120 psi on dispensers. 33

General Information Most of the unit s weight is at the top. Extra care is needed when moving the unit to prevent tipping. Do Not remove protective film until unit is in operating position. All four leveling legs must contact the floor to support and stabilize the full weight. Do not drop unit. Remove exterior shipping materials prior to moving unit into home. Use two or more people to move and install unit. Failure to follow this instruction can result in back or other injury. To avoid personal injury, wear gloves when performing any installation procedure and wear eye protection when cutting metal straps. Tip Over Hazard Appliance is top heavy and tips easily when not completely installed. Keep doors closed until appliance is completely installed and secured per installation instructions. Use two or more people to move and install appliance. Failure to do so can result in death or serious injury. Unpacking unit 1. Remove top and bottom strap. 2. Remove top cap. 3. Cut carton rear approximately 1/4 (0.6 cm) to 1 (2.5 cm) from right corner with a utility knife extended 1/4 (0.6 cm). 4. Remove carton and exterior packaging. Save cardboard shipping material to protect floor surface when installing unit. Remove anti-tip board, kickplate and door trim pieces (DF models) from rear of unit. Moving Unit Remove shipping brackets from skid by removing 4 bolts (2 on each side) with a 1/2 deep-well socket wench and a pair of pliers. Note: Tilting unit is not required to remove shipping brackets. Slip appliance dolly between unit and skid. Only use dolly from the rear of the unit to remove unit from skid. After the unit is removed from the skid, a dolly can be used from either side or the back BUT NOT THE FRONT. Note: Use excess packaging to protect decorative trim; also, verify that leveling legs are up (0 adjustment). 34

Flush Mount Side Trim Installation Note: If the unit is to be installed flush with the cabinets, the flush mount side trim must be installed first. If not, skip to installation. Step 1 - Locate the necessary parts: Two (2) flush mount trim pieces and a hardware kit with twenty-two (22) screws. Step 2 - Remove the side trim on the refrigerator and discard the trim and screws. Step 3 - Align the top of the flush mount side trim with the top of the unit's machine compartment. Using the screws included in the hardware kit, attach the side trim to the unit, only using the holes visible through the side trim. Note: Do not use the screw holes in the machine compartment. Installation 1 2 Place unit in front of cutout. Pull the center grille louver up at an angle and pull out. 3 4 Using an 8 magnetic nut driver, remove the two 1/4 screws. Remove grille assembly. 35

Hinge Adjustment 5 Front of unit 6 2 2 1 1 3 Remove 4 side screws and remove unit top. Loosen the 4 hinge screws. Adjust door. Retighten 4 hinge screws. 7 1 2 Replace unit top. Replace 4 side screws. 8a 8b Wall 2 x 4 Wall 2 x 4 Refrigerator Attach a single 2 x 4 to wall stud (refer to dimensions page for exact location). Refrigerator If needed, depending on cabinet and depth, attach second 2 x 4 to first 2 x 4. 36

9 10a 3 Plug in power cord to verify operation. Note: Make sure power switch and showroom switch are in the On Position. Place unit within 3 of being flush with cabinets. Note: To avoid cabinet damage, place cardboard between cabinets and unit. When moving unit, do not crimp, kink or crush water supply line. 10b 11 Carefully move unit until semi flush with cabinet (depending on unit). Pull supply tubing forward under unit. Note: DO NOT use plastic water lines. 12 13 Flush water line by running two quarts of water into a bucket. Turn water off. Connect supply tube to water valve using a 1/2 wrench. Note: DO NOT overtighten. 37

14 15 Turn on water supply and check for leaks. Lift unit off rollers to desired height and level unit using a 5/16 head wrench. Note: DO NOT use an electric device. Overtightening can cause damage. 16 17 Screw Wall 2 x 4 Refrigerator Attach positive secure self-tapping bolts to 2 x 4 using a 22 extension. Kickplate Installation 18 Verify that drain pan is installed and aligned. 19 1 2 2 3 Align holes on both ends of louvered panels and insert screws. Using a Phillips screwdriver, attach the kickplate to the unit and adjust to desired height. 38

Door Stop Adjustment 20 21 1 3 90 110 120 1 2 2 Open refrigerator door so door stop and shoulder screw are accessible. Note: Shoulder screw should be in 110 door opening position. Remove shoulder screw and place in 90 or 120 position. Final Installation 22 23 Replace top air grille. Using an 8 magnetic nut driver, replace the two 1/4 screws. 24 25 Replace the center grille louver. Open door. Display should flash. 39

26 Press ACTIVATE CONTROLS button pad and close door. Note: There is a 6 minute delay before the unit starts. 40

Performance Checklist Verify cabinet size. Verify electrical supply and water supply (if applicable). Install anti-tip device(s) and verify unit is secure. Position unit in cutout, level at desired height, and secure unit. Plug-in unit and verify operation. Connect water supply (if applicable). Verify icemaker fill tube is properly inserted. Verify icemaker bailarm is down. Align/square door(s). Verify drain pan is properly installed and there are no leaks in water connection. Install kickplate. Remove internal packaging and labels and wipe unit down. Installer s information: Installer s name: Installer s company: Date: 41

Verify Operations Control Panels All Refrigerator ACTIVATE CONTROLS REF TEMP HIGHER LOWER FREEZER MAX FRZ MAX REF FAST COOL SAB SHOW C F REFRIGERATOR DOOR OPEN POWER HIGH TEMP FAST COOL MAX REF ALARM OFF DISPLAY OFF All Freezer ACTIVATE CONTROLS FRZ TEMP HIGHER LOWER FREEZER MAX FRZ MAX REF FAST COOL SAB SHOW C F REFRIGERATOR DOOR OPEN POWER HIGH TEMP FAST COOL MAX FRZ ALARM OFF DISPLAY OFF 1. Press Activate Controls pad. 2. Verify unit is not in Sabbath Mode. If in Sabbath Mode: A. The Sabbath Mode will disable the interior lights, display (except SAB indicator, temperature and compartment indicator) and alarm. To exit the Sabbath Mode: B.. Press and hold Activate Controls and then Display Off for 3 seconds. (The control will beep three times to alert the user the Sabbath Mode has been exited.) 3. Verify unit is not in Showroom Mode. If in Showroom Mode: A. The Showroom Mode will disable the refrigeration system but all other functions are normal. These include lights and control. (If the refrigerator is in Showroom Mode, SHOW will be lit.) To exit Showroom Mode: B. Press and hold Activate Controls ; while holding, press and hold Higher and Alarm Off together. (The control will beep three times to alert the user that Showroom Mode has been exited.) 4. Press Activate Controls then press and hold Lower ; while holding, press and hold Display Off and hold until beeps (force start compressor). 5. All models need to be set at 38 F and 0 F for the refrigerator and freezer respectfully - factory setting. 42

Service & Registration If service is required, call your authorized service agency. Have the following information readily available. Model number Serial number Date purchased Name of dealer from whom purchased Clearly describe the problem that you are having. If you are unable to obtain the name of an authorized service agency, or if you continue to have service problems, contact Viking Range, LLC at 1-888-(845-4641), or write to: VIKING RANGE, LLC PREFERRED SERVICE 111 Front Street Greenwood, Mississippi 38930 USA Only authorized replacement parts may be used in performing service on the appliance. Do not repair or replace any part of the appliance unless specifically recommended in the manual. All other servicing should be referred to a qualified technician. Record the following information indicated below. You will need it if service is ever required. The serial number and model number for your appliance are located on the identification plate mounted behind the top light. Model number Serial number Date of purchase Date installed Dealer's name Address 43