Baros Comfort Turn Mattress

Similar documents
USER INSTRUCTION MANUAL SAPPHIRE SERIES 1100 & 1100EC

User Instruction Manual

User Instruction Manual

USER INSTRUCTION MANUAL SAPPHIRE SERIES 800

User Instruction Manual

User Instruction Manual

User Instruction Manual

CANAIR Products Available from Sunrise Medical

AMBIENCE Low Air Loss Mattress Replacement System

SERVICE PROCEDURES. Mattress 2 Pipe Overlay or Replacement

Delta Plus. PA8900 Bariatric Mattress Replacement System. User Manual

Med-Aire 8 Alternating Pressure Mattress Replacement System With Low Air Loss OPERATOR S MANUAL

English 1 AIR ALTERNATING PRESSURE MATTRESS REPLACEMENT SYSTEM

Anti-Decubitus Air Alternating Pressure Mattress System Operation Manual

MULTI-FUNCTIONAL PORTABLE ROTATION SYSTEM P4000 P4001 C4000 Series Control Unit M4000 Series Mattress. Operator s Manual P/N Rev B 10/10

PRELUDE. User Manual. PA3500 Mattress Overlay System. Guarantees and Warranty. 1.1 General Information 1.2 Intended Use. 3.1 Unpacking 3.

AIR EXPRESS LAL. P1500 LOW AIR LOSS THERAPY SYSTEM REF C1500 Control Unit REF M1500 Mattress. Operator s Manual P/N /03

DELUXE ALTERNATING PRESSURE SYSTEM USER GUIDE

User Manual standard for Medical Electrical. Control Number 95CG. Classified by. Underwriter s Laboratory Inc. for UL

DIRECTHEALTHCAREGROUP.COM. Air Suresse. Service Manual

Med-Aire Assure 5 Air + 3 Foam Base Alternating Pressure and Low Air Loss Mattress System

Mason Air AS8800/ AS8800-RR/AS Instruction Manual. Low air loss/alternating pressure mattress

E N T E R P R I S E S, L L C. Innovative health solutions

DOC AP Lo50 Owner's Manual REV 001 Page1

PUMP. General User/ Safety Guide HARVEST 1 PUMP. E

User Manual. Invacare APM Model CG9900 Mattress

Dyna-Form Air. Alternating Pressure Relief Overlay System

OPAL ACTIVE OVERLAY SYSTEM

SERVICE PROCEDURES. Control Unit 220DIO 4 pipe

User manual CuroCell Neo CX13 CuroCell Neo CX19 Alternating pressure mattress. Item number user manual:

Service Manual DIRECTHEALTHCARESERVICES.CO.UK

OPERATING INSTRUCTIONS K-6 & K-Z ELITE & OEM SERIES

Enhance DX. Mattress Replacement System. User Manual

Iron - low. - medium - high Do not iron. Bleach - chlorine. Do not bleach. Tumble dry - low - medium - high Do not tumble dry

WINDSOR ACTIVE REPLACEMENT

APH166 Morpheus Air USER MANUAL. Issue 3-24/05/2017. Apollo Healthcare Technologies Ltd. Holme Street, Liversedge, West Yorkshire, WF15 6JF.

CONTENTS IMPORTANT SAFEGUARDS INTRODUCTION PRODUCT DESCRIPTION INSTALLATION OPERATIONS CLEANING...

Quick start guide for Altrix Precision Temperature Management System

OPERATION INSTRUCTION

CBC II Blood Collection & Reinfusion System. Installation and use in Operating Room

User s Manual. Alternating Air Mattress Model No.: MA-6100

User manual CuroCell Cirrus 2.0 Alternating pressure system. User manual item number:

User manual CuroCell S.A.M. Static Antidecubitus Mattress. User manual item number:

Convertible Powered/ Non-Powered Dynamic Mattress System. Operation Manual. Distributed by:

Operation/Maintenance BLOWER OVERHEAD Ionizing Air Blower

CPAP Washbasin Manual

FagronLab NP-1 UV. Negative pressure workbench. User Manual

Service Centers: Conair Consumer Products Inc. 156 Parkshore Drive. Brampton, Ontario L6T 5M1

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Wheelchair CLEANING PROTOCOLS

Installation & Operation Manual For ENERGENICS In-Line Space Saver Lint Filters

STATIC ELIMINATOR I443A INSTRUCTION MANUAL

Operating Manual. Theraflow. Alternating Mattress Replacement Systems. Model MRS-TFW-001 Standard

Class II Biosafety Cabinets

CMU701/ 705 OPERATIONS & INSTRUCTION MANUAL

ELECTRIC BLANKET INSTRUCTIONS

Infection Control Manual Residential Care Part 3 Infection Control Standard IC9: Environmental

HUMIDIFIERS OWNERS MANUAL A GUIDE TO OPERATING AND MAINTAINING YOUR HUMIDIFIER 49FH, 49FP, 49BF, 49WS, & 49BG

AtmosAir Mattress Replacement System User Guide Instructions for Use

Use r manual Edition MG Tube Master Anti-bedsore alternating pressure mattress of tubular structure VCM502D

GULFSTREAM PLASTICS LTD.

MODEL HUM HUMIDIFIERS

Administration of AMBISOME Using the GemStar Pump

Compression therapy device & accessories Model 701A User manual

USER MANUAL KGNVCTBVAA

CircuFlow Quick Setup Guide

Burnett Vacuum Support Instructions

7. Troubleshooting. Description and Corrective Action. Low Pressure

Instruction Manual and Warranty Information

User manual CuroCell S.A.M. Switch Static Antidecubitus Mattress. User manual item number:

Instructions for Installation and Use

Operating Instructions. Transair Alternating Pressure Care Overlay System

PURELL Point of Care Compliance Dispenser

FALL REDUCTION. General User/ Safety Guide ALARM SYSTEM. E

Operation Manual for Eco-Logic Pond & Lake Restoration System

AIR. Low-Air Loss Combined with. Advanced Wound Therapy & Fall Prevention in a Non-Powered Mattress. Non-Powered Therapy

Cleaning and Sanitation Procedures Module Deli

Superior Spa with Aqua-Aire

Model K205 M Plus Part No

CLEAN MIST SMART HUMIDIFIER Instruction Manual and Warranty Information IM0031B READ AND SAVE THESE INSTRUCTIONS

Your Blast Vac Pro. Your Blast Vac Pro

Cardio Chair Position

HV380ANZ. Series INSTRUCTIONS AUST: NZ:

Service Manual for X9.5 and Older Models

GE JB400 Steam Clean Range. Range Models: JB400DP1WW JB400DP1BB JB400SPSS

2015 Myco Industries, Inc Fax:

INSTRUCTION MANUAL PUMP R103H UK / R Made in China.

CLEAN MIST DUAL TANK SMART HUMIDIFIER. Instruction Manual and Warranty Information READ AND SAVE THESE INSTRUCTIONS IM0036A

Operating & Installation Instructions Fully Automatic Washing Machine (Domestic use)

ATRIX REVO RED bagless HEPA CANISTER VACUUM CLEANER

Nichole Ernst CEO Powerhouse International

Stryker Glide Lateral Air Transfer System. Operations/Maintenance Manual. Model 3062

K 2.97 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

OWNER S MANUAL LG CORDLESS VACUUM CLEANER

HEDMAN DI-50. Endorser Instructions. Hedman DI-50 Operators Guide

OPERATING AND MAINTENANCE MANUAL

Instructions For Use. Hybernite ROC 2300 Rainout Control System

CHOCOLATE TEMPERING SYSTEM

(Place Logo from Lab here)

VENTURI Compact 300 NPWT Systems Choice of Therapy Modes Advanced Predictive Low Vacuum Alarm

Transcription:

Baros Comfort Turn Mattress User Instructions Maximum User Weight 25st/160kg or 70st/450kg Tel: 01279 425648 Fax: 01279 425653 Email: sales@1stcallmobility.co.uk www.1stcallmobility.co.uk

Keypad Quick Reference Pulsate Press to begin Pulsation therapy. Alarm Silence Mutes the audible alarm. (Visual light will not turn off until failure is resolved.) Firm Increases airflow for a firmer setting. Soft Decreases airflow for a softer setting. Autofirm Quickly inflates mattress to maximum firmness. Cycle Time Increases or decrease the time of cycle between 3 to 90 minutes. Fowler Used when head section of bed is elevated. Increases airflow to the mattress. Mode Press the Mode button to select Right Turn, Left Turn or Full Turn. Lockout Locks all functions automatically after 3 mins. To disable, press and hold lockout button for 3 sec. Refer to this page as needed for quick reference to the control panel functions. Provides individual button illustration and function description. 1

Operating Instructions 1) Remove standard mattress from the bed. 2) Replace standard mattress with the SAPPHIRE SERIES COMFORT TURN mattress. (Be sure air tubing is at the foot end of the bed.) 3) Strap air support mattress to bed frame on all four sides. 4) Place control unit on the footboard of the bed using the two retractable hooks located on the back of the unit. (If no footboard is available, put blower on the floor away from traffic.) To avoid blocking the air intake, DO NOT place control unit on its back. 5) Attach the air tubing to the blower unit, being sure it snaps in tight. (Be sure air tubing is not kinked and is unobstructed.) 5) Attach the air tubing to the blower unit, being sure it snaps in tight. (Be sure air tubing is not kinked and is unobstructed.) 6) NOTE: (110V unit ONLY) Plug unit into grounded 110V A/C outlet. 7) NOTE: (220V unit ONLY) Plug unit into grounded 220V A/C outlet. 8) Press the Auto Firm button for quick inflation. 9) Place the patient on the bed after inflation to insure the air cells do not become twisted or kinked. 10) Once the air mattress is completely inflated, press the Auto Firm button again to exit that mode. 11) Static Mode a. Press the Mode button until Static is illuminated. b. Set desired firmness with the Soft/Firm buttons. 12) Fowler Mode a. When elevating the head section of the mattress, press the Fowler button to increase airflow for seat inflation. 13) Auto Fowler attachment (Optional) a. When elevating the head section of the mattress, Fowler mode will automatically turn on. Auto Fowler attachment This is where the Auto Fowler attachment connects to the control unit. 2

14) Pulsate Mode a. Press the Pulsate button. b. Set the desired cycle time with Cycle Time buttons (3-20 minutes) c. Set desired firmness with the Soft/Firm buttons. 15) Turning Mode a. Press the Mode button until Right Turn, Left Turn or Full Turn is illuminated, which ever mode you desire. At this setting the degree of rotation will be approximately 40 degrees. b. In Full Turn mode the control unit has a preset of 3-minute intervals. The intervals may be adjusted by depressing the cycle time button to desired time (3 to 20 minutes. 30, 45, 60, 75 or 90 minutes also.) c. To set comfort level press corresponding firm or soft button. There are 10 levels of firmness indicated by lighted bars located on the control panel. WHEN THE PATIENT IS PUT IN TURNING MODE, WATCH IV LINES AND TUBING TO INSURE THAT THERE IS ENOUGH LENGTH TO ACCOMMODATE A FULL ROTATION. IT IS ADVISED TO MONITOR THE PATIENT FOR 2 TO 3 COMPLETE ROTATIONS. Notice: When the cycle time is showing Hd the control unit will hold the patient in the turn position until a caregiver physically changes the cycle time. 16) Lock-out Feature a. After 3 minutes, if there are no changes to the blower settings, the lockout feature will activate. b. Press and hold the Lock-out button for 3 seconds to disengage the lock-out feature. 17) For quick deflation or for CPR use: a. Turn power off b. Twist CPR plug on the mattress to open. c. Remove the hoses from the control unit. 3

Mattress Cleaning Instructions WARNING and CAUTION: A. It is recommended that gloves and protective clothing be worn at all times during cleaning and disinfecting B. Hypercarbonate and phenol based solutions should not be used. During Operation: For normal soil, wipe down cover and interior sacs with a standard cleaning disinfectant and wipe off excess moisture with a towel. Laundering Mattress: 1. Disconnect the power from the Control Unit and deflate the interior sacs. 2. Disassemble cover, interior sacs, connecting hoses, and base. Place them in different laundering baskets. 3. The interior sacs must be hand cleaned only. DO NOT place in sterilization room or chamber. Use a spray disinfectant to wipe down interior sacs. Air-dry sacs. DO NOT expose to heat. 4. Spray disinfectants and wipe down foam cover. 5. Place cover and base ONLY in washing machine. 6. Use standard hospital disinfectant/detergent. 7. Set washing cycles as recommended below: Regular Cycle a) Pre-soak with disinfectant/detergent with diluted bleach in cold water (10 minutes.) b) Main wash for 15 minutes (Time depending on soil level). c) Rinse Cycle: 5 minutes minimum. d) Spin/Drain Cycle: 5 minutes minimum. e) Air-dry or place in dryer at very low or no heat. 8. After the cover, interior sacs, and base are dry, store them in a sterilized bag and seal for next use. NOTICE: DO NOT use water temperatures greater than 150 F (65 C). Blower Unit Cleaning Instructions WARNING and CAUTION: A. Hand clean only. DO NOT place in sterilization room or chamber. B. It is recommended that gloves and protective clothing be worn at all times during cleaning and disinfecting C. Hypercarbonate and phenol based solutions should not be used. D. Make sure unit is turned off and unplugged before cleaning. For normal soil, wipe down with a standard cleaning spray and wipe off excess moisture with a towel. Spray with a disinfectant and let it stand for a few minutes before wiping down. Check corners and creases for soil build-up. Look to see if any external parts are damaged or need replacing such as: hooks, foot pads and filter. Replacement parts can be issued. Contact your representative for servicing. NOTE: To keep your equipment working efficiently and effectively for an extended time period, it is essential to make sure the equipment is cleaned regularly and well maintained. Maintenance: Air Filter The foam air filter on the back of the Control Unit must be cleaned weekly with soap and warm water. Replacement of the foam filter is recommended every 6 months. Power Cord The power cord should be checked for damage each time the Control Unit is used. The cord should always be kept away from free moving parts. If the power cord is damaged it will need to be replaced. The filter is easily removed and reinserted through the gap in the back case. 4

Technical Specification 25st/160kg Version Inflated Dimensions Cycle Time Electrical Rating Product Weight: Pump weight and lead Maximum User Weight Approx.36 (90cm)W x 80 (204cm)L x 8 (20cm)H Variable (3-20, 30, 45, 60, 75, 90 minutes) 240V 5kg 6.5kg 25st/160kg Technical Specification 70st/450kg Version Inflated Dimensions: Cycle Time Electrical Rating Product weight Pump weight and lead Maximum User Weight Approx. 48 (120cm)W x 80 (204cm)L x 8 (20cm)H Variable (3,20, 30, 45, 60, 75, 90 minutes) 240V 12.5kg 6.5kg 70st/450kg 5